Reactor na kwamitin diyya na LV

1. An yi na'urar ne da simintin tururi na epoxy resin, bayan an yi mata aiki mai zafi sosai.
2. Aikin rufin na'urar yana da kyau, ƙarfin injina mai ƙarfi, ikon bayan ƙarfafa fiber ɗin gilashi yana shafar babban girgizar yanzu da fashewar zafi da sanyi.
3. Aikin hana danshi yana da kyau.
aika Sunan
Download
  • Bayarwa da sauri
  • Quality Assurance
  • 24/7 Sabis na Abokin Ciniki

Product Gabatarwa

Reactor na kwamitin diyya na LV

Product Gabatarwa

Idan kuna buƙatar ingantaccen gyaran wutar lantarki tare da kariyar harmonic, Reactor ɗinmu na LV Reactive Compensation Panel yana ba da cikakkiyar mafita. Wannan ɓangaren maganadisu mai ƙarfi yana shigarwa a jere tare da bankunan capacitor don hana yanayin resonance mai haɗari. Yana kare tsarin wutar lantarki daga haɓaka harmonic yayin da yake kiyaye ingantaccen gyaran wutar lantarki. Reactor ɗinmu yana canza allunan capacitor na yau da kullun zuwa tsarin matattara masu inganci. Na'urar tana da simintin tururin epoxy resin tare da maganin zafi mai zafi don ingantaccen dorewa.

Gina na'urar tana ba da kyakkyawan aikin kariya da ƙarfin injina mai yawa. Ƙarfafa zaren gilashi yana ba da damar juriya ga manyan tasirin wutar lantarki da zagayowar zafi. Tsarinmu mai jure da danshi yana tabbatar da ingantaccen aiki a cikin yanayi mai ƙalubale. Kuna samun kariya ta masana'antu wacce ke tsawaita tsawon rayuwar kayan aiki sosai.

Technical dalla

siga Ƙayyadaddun bayanai
Voltage rating 400V - 690V
Frequency 50 / 60 Hz
Abin da ke Hana Faɗaɗa Faɗaɗa 5.67%, 7%, 14%
Sanarwa na yanzu 630A - 4000A
Ƙungiya Kashi Aji F (155°C) / Aji H (180°C)
Rashin layi L > 0.95 × Ln a 1.8 × In
Matsalar abu Karfe mai siffar siliki
Haƙuri na Inductance ± 3%
Matsayin ƙarshe <55dB
Rating Kariya IP20 / IP54
Standards Dokokin IEC 60076-6, IEEE 519
Tashin zafin jiki <135K (Aji na H)
Matsayin Matsayi Har zuwa 4000m

Babban fasali da Fa'idodi

Tsarinmu yana ba da fifiko ga aiki da aminci. Tsarin shigar da matsi na injin yana tabbatar da juriya ga danshi da kwanciyar hankali na inji. Kuna amfana daga raguwar karkacewar jituwa da ingantaccen ingancin wutar lantarki.

Tsarin tsakiya mai rarrabuwa yana rage asarar wutar lantarki ta eddy. Gibin iska da yawa yana rage tasirin kwararar iska. Wannan hanyar injiniya tana samar da daidaiton inductance a ƙarƙashin yanayi daban-daban na kaya.

Tsarin gyaran varnish mai inganci yana ba da kyawawan kaddarorin rufi. Tsarin yana jure yanayin zafi da matsin lamba na inji. Kuna samun aminci na dogon lokaci a cikin mawuyacin yanayi na masana'antu.

Kayan aiki masu inganci suna jure wa abubuwan da suka shafi muhalli. Tsarin da ya dace yana magance nauyin da ya wuce kima. Jarin ku yana ba da aiki mai kyau kowace shekara.

Practical aikace-aikacen kwamfuta

Manyan wuraren kera kayayyaki sun dogara ne da na'urorin samar da wutar lantarki namu don kariya. Ayyukan walda da tanderun baka suna haifar da mummunar karkacewar jituwa. Reactor ɗinmu na LV Reactive Compensation Panel yana hana lalacewar bankin capacitor a cikin waɗannan muhalli.

Cibiyoyin bayanai suna buƙatar ingantaccen ingancin wutar lantarki don ayyuka masu mahimmanci. Tsarin UPS da kayan aikin wutar lantarki na uwar garken suna samar da ma'auni masu mahimmanci. Reactors ɗinmu na 14% masu cirewa suna kare su daga wuce gona da iri.

Gine-ginen kasuwanci na zamani sun haɗa da hanyoyin haɗin kai daban-daban. Hasken LED da inverters na hasken rana suna ƙirƙirar hulɗa mai rikitarwa. Reactors ɗinmu suna tabbatar da ingantaccen haɗin grid da kariyar transformer.

Tsarin sarrafa kansa na masana'antu yana amfana daga tacewa mai jituwa. Na'urorin mita masu canzawa suna haifar da yanayi mai ƙalubale na aiki. Masu samar da wutar lantarki namu suna kiyaye ingancin gyaran wutar lantarki duk da bambancin kaya.

Ta yaya Yana Works

Reactor ɗin yana gabatar da amsawar inductive mai sarrafawa cikin tsarin ku. Wannan yana canza mitar resonant daga mitoci masu haɗari na harmonic. Sakamakon yana hana amsawar layi ɗaya tsakanin capacitors da transformers na wadata.

Harmonics suna fuskantar babban juriya a wurin reactor. Wannan yana toshe mitoci masu cutarwa daga shiga bankunan capacitor. Capacitors ɗinku suna aiki lafiya a cikin iyakokin zafi.

Tsarin jerin yana haifar da tasirin tacewa mara tsari. Takamaiman matakan daidaitawa suna rage girman fuska yayin da mitar asali ke wucewa kyauta. Kuna cimma duka gyaran ƙarfin lantarki da rage ƙarfin jituwa.

Ɗaukar ƙarfin lantarki yana buƙatar na'urori masu ƙarfin lantarki masu inganci. Ƙungiyar injiniyanmu tana ƙididdige ƙimar ƙarfin lantarki da ta dace don aikace-aikacenku. Cikakken tsarin yana ba da ingantaccen aiki da kariya.

Ƙarfafa Ƙarfafawa

Xi'an Xikai yana kula da ingantaccen tsarin sarrafawa a duk lokacin samarwa. Tsarin masana'antarmu ya cika ka'idojin ISO9001. Kowane Reactor na LV Reactive Compensation Panel yana yin gwaji mai zurfi kafin a kawo shi.

Gwajin hauhawar zafin jiki yana tabbatar da aikin zafi a ƙarƙashin kaya. Tabbatar da daidaiton inductance yana tabbatar da daidaiton mitar daidaitawa. Gwajin ƙarfin lantarki na impulse yana tabbatar da ingancin rufin.

Cibiyarmu tana kula da ayyukan da suka kai ga buƙatun tsayin mita 4000. Kayayyaki da hanyoyin zamani suna samar da inganci mai daidaito. Kuna karɓar samfuran da suka cika ƙa'idodin ƙasa da ƙasa da buƙatun masana'antu.

Ci gaba da ingantawa yana jagorantar tsarin masana'antarmu. Muna saka hannun jari a cikin kayan aiki na zamani da ƙwararrun masu fasaha. Odar ku tana amfana daga ƙwarewar kayan aikin lantarki na shekaru da yawa.

Me ya sa Zabi Mu

Xi'an Xikai yana ba da cikakkun hanyoyin samar da wutar lantarki. Jerin samfuranmu ya ƙunshi aikace-aikacen 0.4kV zuwa 40.5kV. Kuna aiki tare da mai samar da tsarin haɗin gwiwa da aka kafa.

Ƙungiyar injiniyanmu tana ba da shawarwari na musamman ga aikace-aikace. Muna taimaka muku zaɓar madaidaicin ma'aunin cirewa don yanayin jituwa. Magani na musamman yana magance buƙatun shigarwa na musamman.

Takaddun shaida masu inganci sun haɗa da ISO9001, ISO14001, da OHSAS18001. Kayayyakinmu suna samun ci gaba a cikin gida da kuma ƙasashen waje. Kuna samun kayan aiki waɗanda suka cika ƙa'idodi masu tsauri.

Tallafin fasaha yana ci gaba bayan isarwa. Ƙungiyarmu tana taimakawa wajen aiwatar da ayyuka da kuma magance matsaloli. Haɗin gwiwa na dogon lokaci yana tabbatar da cewa tsarin wutar lantarki ɗinku yana aiki yadda ya kamata.

FAQ

T: Wane factor na detuning ya kamata in zaɓa don aikace-aikacena?

A: Zaɓi kashi 7% don nauyin masana'antu na yau da kullun tare da VFDs suna samar da harmonics na 5 da 7. Zaɓi kashi 14% idan akwai mahimman abubuwan harmonics na 3 daga lodin mataki ɗaya kamar kwamfutoci da hasken LED.

T: Me yasa nake buƙatar manyan capacitors na wutar lantarki tare da reactors?

A: Reactor ɗin jerin yana haifar da ƙaruwar ƙarfin lantarki a kan tashoshin capacitor. Ga tsarin 400V tare da reactors 7%, yi amfani da mafi ƙarancin capacitors 440V. Tare da reactors 14%, ƙayyade capacitors 480V ko 525V.

T: Ta yaya zan hana zafi fiye da kima na reactor?

A: Tabbatar da isasshen iska a cikin ƙirar panel ɗinku. Tabbatar da matakan daidaitawa ba su wuce ƙayyadaddun kayan aikin reactor ba. Tabbatar cewa tsarin sanyaya kabad yana aiki yadda ya kamata.

T: Zan iya ƙara reactors zuwa ga allunan capacitor da ke akwai?

A: Wannan yana buƙatar gyare-gyare a kan allo, gami da ƙarfin wutar lantarki mai ƙarfi da ƙarfafa tsarin. Tuntuɓi ƙungiyar injiniyanmu don kimanta yuwuwar sake gyarawa.

T: Me ke haifar da hayaniyar reactor mai yawa?

A: Ƙaramin ƙarar maganadisu abu ne na yau da kullun. Ƙarar ƙarar tana nuna laminations na tsakiya ko aiki a waje da sigogin ƙira. Wannan yana nuna ƙarancin masana'anta ko damuwa mai ƙarfi.

Tuntube Mu

Shin kuna shirye don inganta ingancin wutar lantarki ta hanyar amfani da hanyoyin magance diyya na ƙwararru? Ƙungiyarmu ta fasaha a shirye take don taimakawa tare da takamaiman buƙatunku.

Tuntuɓi sashen tallace-tallace namu don cikakkun bayanai da ambato. Muna ba da cikakken tallafi tun daga tattaunawa ta farko har zuwa aikin da aka yi.

Imel: serina@xaxd-electric.com

Bari mu taimaka muku zaɓar mafi kyawun Reactor don LV Reactive Compensation Panel don aikace-aikacenku. Ku dandani aminci da aiki wanda ke zuwa daga aiki tare da ingantattun hanyoyin samar da wutar lantarki na Xi'an Xikai.

Aika