Makullan katsewa na waje sune mafi mahimmancin fasalin tsaro a cikin tashar samar da wutar lantarki saboda suna hana wutar lantarki a lokacin gyara da gaggawa. Ta hanyar yin hutu a cikin da'irori, waɗannan na'urori suna kare mutane da kayan aiki, musamman a wuraren buɗewa inda juriya da dorewar yanayi suke da mahimmanci. Lokacin da wuraren kera kayayyaki, kayan aiki, da masu tsara tsarin suka zaɓi makullin katsewa da ya dace, suna saka hannun jari a lokacin aiki na kasuwanci, bin ƙa'idodin aminci, da kuma tanadin kuɗi na dogon lokaci.

makullan cire haɗin waje makullan cire haɗin waje​​​​​​​

Fahimtar Maɓallan Haɗa Haɗin Waje a Kariyar Tashar Wurare

Bayyana Babban Aikin Maɓallan Keɓewa

Makullin cire haɗin waje na'urar sauyawa ce wadda ba ta da iska kuma ana amfani da ita don raba sassan layukan lantarki a cikin tsarin watsawa da tashoshin ƙasa. Maimakon dakatar da kwararar wuta kamar yadda masu katse wutar lantarki ke yi, waɗannan makullan suna aiki lokacin da babu ko kaɗan a kansu don samar da sarari mai haske wanda ke ba da damar samun damar gyara lafiya. Makullin Cire haɗin GW5 Babban Wutar Lantarki misali ne mai kyau na wannan saboda yana iya ɗaukar ƙarfin lantarki mai ƙima na 72.5kV zuwa 126kV da kwararar wuta har zuwa 2000A yayin da yake kiyaye juriyar hulɗa a ƙasa da 75μΩ.

Siffofin Zane Masu Juriya Da Yanayi

Matsalolin muhalli da tashoshin samar da wutar lantarki ke fuskanta a kowane lokaci sun haɗa da feshin gishiri mai guba daga bakin teku, guguwar ƙura a hamada, da kuma yanayin zafi ƙasa da sifili. Ana yin makullan da ke ɗaukar lokaci mai tsawo da sassan ƙarfe masu zafi waɗanda ke ƙirƙirar garkuwar zinc wanda ke hana tsatsa tsawon shekaru da yawa. Tsarin watsawa da aka yi da bakin ƙarfe, kamar fil da bushings, ba su da wuraren da aka saba samun matsala waɗanda ruwa ke shiga. Sabbin samfura suna amfani da bayanan ƙarfe na aluminum waɗanda ke taimakawa wajen fitar da zafi, don haka babu wuraren da ke da zafi lokacin da injin ɗin ke aiki akai-akai a yanayin zafi daga -40°C zuwa +85°C.

Bayanin Aikin Da Aka Yi da Hannunka Ko Injin Mota

Don keɓewar da'ira, makullan cire haɗin hannu suna amfani da hanyoyin da hannu ke amfani da su. Suna aiki da kyau a ƙananan tashoshin wutar lantarki inda buƙatun sauyawa ba sa faruwa akai-akai. Sigogi masu injin suna aiki tare da tsarin SCADA, don haka ana iya sarrafa su daga nesa, suna kare mutane daga wuraren da wutar lantarki ke da ƙarfi. Wanne za a yi amfani da shi ya dogara da sau nawa ake buƙatar amfani da shi, ƙa'idodin aminci, da kuma yadda yake buƙatar aiki tare da tsarin sarrafawa da ke akwai. Idan aka kwatanta da ƙirar juyawa ta gargajiya, ƙira ta zamani kamar tsarin pantograph na kwance yana rage gogayya yayin sauyawa. Wannan yana nufin cewa tazara tsakanin gyara sun fi tsayi da kashi 40% kuma lalacewar injina ta fi ƙasa da kashi 40%.

Muhimmin Matsayin Maɓallan Haɗa Haɗin Waje a Tsaron da Amincewa da Wuri Mai Sauƙi

Kare Ma'aikatan Kulawa Ta Hanyar Keɓewa A Gani

Tsaro a kula da wutar lantarki ya dogara ne akan hanyoyin kulle-kulle waɗanda ake buƙatar a duba su ta jiki don tabbatar da cewa wutar ta kashe. Cire makullan haɗin suna ba da wannan garantin ta hanyar raba ruwan wukake ta yadda za a iya gani. Wannan yana haifar da gibin iska wanda ke tabbatar da cewa da'irar ta kashe kafin mutane su kusanci kayan aikin. Nau'in GW5 yana da maɓuɓɓugan haɗin bakin ƙarfe da aka matse a waje waɗanda ke sa ƙarfin haɗin ya dawwama kuma ya hana tsatsa har tsawon rayuwar na'urar. Wannan yana tabbatar da cewa yana aiki kamar yadda aka zata lokacin da aminci ya dogara akan ingantaccen haɗin.

Juriyar Muhalli a Yanayin Aiki Mai Wuya

A cikin saitunan tashoshin ƙarƙashin ƙasa, bambanci tsakanin kayan aikin da aka kimanta don amfani a cikin gida da waje yana da matuƙar muhimmanci. Makullan cikin gida ba su da kariya daga tsatsa da rufin da suke buƙatar kasancewa a waje a lokacin yanayi. Makullan haɗin waje suna da tsarin watsawa waɗanda aka rufe da kayan rufin da ke jure wa hasken UV, don haka za su iya daɗewa na tsawon shekaru ba tare da lalacewa ba. Kammalawar galvanized mai zafi ba sa tsatsa, ko da a wuraren bakin teku inda hazo mai gishiri ke hanzarta aikin tsatsa. Wannan juriya kai tsaye yana haifar da ƙarancin farashin kulawa da tsawon rai fiye da shekaru 30 a cikin yanayi mai kyau.

Bin Ka'idojin Masana'antu da Takaddun Shaida

Shawarwari game da sayayya dole ne su yi daidai da ƙa'idodin doka waɗanda ke canzawa daga wuri zuwa wuri da kuma aikace-aikacen zuwa aikace-aikace. Ana sarrafa maɓallan wutar lantarki masu ƙarfi da na'urorin sarrafawa ta hanyar ƙa'idar IEC 62271-102, wanda ke ƙayyade iyakoki don hauhawar zafin jiki, juriya na injiniya, da ƙarfin dielectric. IEEE C37.32 yana ba da ƙarin ƙa'idodi waɗanda ke mai da hankali kan yanayin grid a Arewacin Amurka. Kayayyakin da suka cika ƙa'idodi biyu, tare da amincewar CE, UL 508, da GOST-R, suna tabbatar da cewa suna aiki tare da wasu samfura a cikin ayyukan ƙasashen waje kuma masu kula da kaya sun karɓe su yayin dubawa. Waɗannan takaddun shaida suna zuwa bayan gwaji da yawa, kamar gwajin dielectric a 230kV na tsawon minti ɗaya da awanni 48 na tsufa wanda ke sa samfurin yayi aiki kamar yadda yake na tsawon shekaru 20.

Yadda Ake Zaɓar Maɓallin Cire Haɗin Waje Mai Dacewa Don Siyan Substation?

Daidaita Ƙarfin Wutar Lantarki da Ƙimar Yanzu da Bukatun Tsarin

Kowace tashar samar da wutar lantarki tana aiki a cikin iyakokin wutar lantarki da aka saita wanda ke gaya wa kayan aikin abin da yake buƙata don yin aikinsa. Dole ne ƙimar ƙarfin lantarki ya fi ƙarfin tsarin girma da aminci. Misali, maɓallin cire haɗin waje wanda aka kimanta a 126kV zai iya aiki tare da layukan watsawa na 110kV kuma ya samar da isasshen daidaiton rufi. Lokacin gano ƙimar halin yanzu, kuna buƙatar duba duka kwararar kaya na yau da kullun da ikon sarrafa gajerun da'irori. Jerin GW5 na iya ɗaukar kwararar wutar lantarki har sau 100 na ƙarfin da aka kimanta. Wannan yana da matukar muhimmanci ga tsarin da ke fuskantar kwararar wutar lantarki daga kunna mota ko na'urar canza wutar lantarki.

Abubuwan da ke Shafar Muhalli a Zaɓen Samfura

Danshi shiga, tarin ƙura, da canje-canjen yanayi duk na iya shafar yadda makullin cire haɗin ke aiki. Ƙimar da aka bayar a NEMA ta ƙunshi matakan kariya. Misali, NEMA 3R yana da kyau don amfani a waje gabaɗaya, yayin da NEMA 4X ya fi kyau ga yanayin sarrafa sinadarai saboda yana tsayayya da tsatsa mafi kyau. Tsawo yana canza yadda dielectrics ke aiki. Kayan aiki na yau da kullun suna aiki a matakin teku har zuwa mita 1000, amma kayan aiki na irin tudu suna ci gaba da aiki har zuwa mita 4000, inda iska mai siriri ke sa rufin ya yi ƙasa da ƙarfi. Fahimtar yanayin wurin yana hana abubuwa lalacewa da wuri kuma yana buƙatar gyara mai tsada.

Kimanta Takardun Shaidar Masana'anta da Tallafin Samfura

Akwai abubuwa da yawa game da zaɓar mai samar da na'urar canza hanyar sadarwa fiye da duba takardun bayanai kawai. Ingancin tsaro a masana'antu yana da mahimmanci. Samfurin da aka ba da takardar shaidar ISO 9001 yana tabbatar da cewa inganci koyaushe iri ɗaya ne ta hanyar rubuta hanyoyin da kuma duba kowane mataki na tsarin masana'antu. Sharuɗɗan garantin sun nuna cewa mai ƙera yana da kwarin gwiwa a cikin samfuransa. Jerin GW5 yana da tsawon shekaru 30 na aiki kuma ana iya bin diddigin duk sassansa daga kayan aiki zuwa ga ƙarshe. Jimlar farashin mallakar yana shafar samuwar tallafin fasaha. Misali, lokacin da matsaloli suka faru a fagen, amsawar gaggawa ta awanni 24 daga ƙungiyoyin injiniya masu harsuna da yawa suna rage lokacin aiki. Kamfanonin da suka kasance a cikin kasuwancin sama da shekaru 40 kuma suka ƙaddamar da raka'a sama da 200,000 sun nuna cewa suna da aminci a cikin yanayi daban-daban.

Shigarwa da Kulawa Mafi Kyawun Ayyuka don Maɓallan Cire Haɗi na Waje a cikin Tashoshin Ƙasa

Shirye-shiryen Yanar Gizo da Bukatun Gidauniyar

Domin a yi aiki yadda ya kamata, harsashin dole ne ya kasance daidai gwargwado kuma mai ƙarfi ta yadda insulators da hanyoyin aiki ba za su fuskanci matsin lamba na injiniya ba. Tsarin tushe dole ne su yi layi a cikin 1mm na juna don kada ruwan wuka ya makale yayin da yake motsi. Kafin a matse kusoshin a bangarorin da ke motsawa da waɗanda aka gyara na tushe, ana buƙatar a daidaita su a kwance da kayan aikin da suka dace. Zane-zane na zamani suna ba da zaɓin shigarwa a ɓangarorin biyu, wanda ke ba ku ƙarin zaɓuɓɓuka a cikin tashoshin ƙarƙashin ƙasa waɗanda ke da ɗan sarari inda ingancin sarari yake da mahimmanci.

Tsarin Shigar Mataki-by-Mataki

Bayan an shirya harsashin, ana haɗa harsashin, ana mai da hankali sosai kan yadda aka sanya insulators. Ana sanya insulators na tallafi a tsaye, tare da layukan tsakiya suna gudana daidai da matakin tushe. Wannan yana tabbatar da cewa an shimfiɗa matsin lamba daidai. Insulators masu aiki dole ne su iya juyawa cikin sauƙi a kusa da layin axial ɗinsu, ba tare da motsi gefe-da-gefe ba wanda zai nuna cewa ba a daidaita su daidai ba. Lokacin shigar da ruwan wuka mai sarrafawa, yana buƙatar a tallafa masa na ɗan lokaci yayin da ake sanya shi, kuma ramukan flange suna buƙatar yin layi tare da axle na radial a wasu kusurwoyi. Faranti na tagulla da aka lanƙwasa suna sauƙaƙa gyarawa a nan gaba saboda ana iya maye gurbinsu cikin sauƙi ba tare da raba komai ba. Kafin kunna wutar lantarki, gwaje-gwajen ƙaddamarwa suna tabbatar da cewa aikin injiniya, juriyar hulɗa, da juriyar dielectric duk daidai ne.

Jadawalin Kulawa Don Inganta Rayuwar Kayan Aiki

Lokacin da za a yi duba na yau da kullun ya dogara ne da yawan amfani da makullan katsewa na waje da kuma yadda yanayin ke fallasa. Ka'idojin amfani sun ce ya kamata a duba amfani da matsakaici-matsakaici duk bayan shekaru biyar, kuma ya kamata a duba abubuwan da ke faruwa a kusa da na'urar nan take. A matsayin wani ɓangare na kulawa, ana buƙatar tsaftace saman insulator don kawar da gurɓataccen lantarki. Hakanan ana buƙatar duba matsewar haɗi a tashoshin, kuma ana buƙatar shafa mai mai a saman hulɗa. Ba a buƙatar a shafa fil ɗin bakin ƙarfe da tsarin bushing akai-akai saboda ba sa buƙatar a kula da su, kuma ana iya duba maɓuɓɓugan hulɗa ba tare da cire tsarin ba. Bin diddigin insulator daga tarin gurɓataccen iska da lalacewar hulɗa daga karyewar wutar lantarki mara kyau hanyoyi biyu ne na gazawa da za a iya guje wa ta hanyar amfani da kayan aiki daidai da tsaftace su akai-akai.

Abubuwan da ke Faruwa a Nan Gaba da Sabbin Dabaru a Fasahar Canja Haɗi ta Waje don Ƙananan Tashoshi

Kulawa Mai Wayo da Haɗakar Kulawa Mai Hasashe

Kayan aikin wutar lantarki da fasahar kwamfuta suna haɗuwa, wanda ke canza yadda ake sarrafa tashoshin samar da wutar lantarki. Maɓallan cire haɗin waje masu amfani da IoT suna da na'urori masu auna zafin lambobin sadarwa, adadin zagayowar aiki, da kuma lokacin da na'urar ke ɗauka don motsawa. Ana amfani da wannan bayanin ta hanyar algorithms na hasashen yanayi don nemo yanayin lalacewa da tsagewa kafin su faru. Wannan yana ba da damar gyarawa bisa ga yanayi, wanda ke rage lokacin aiki da kuma duba waɗanda ba a buƙata. Bin diddigin nesa yana ba da damar sarrafa tashoshin samar da wutar lantarki da aka watsar a yanki, wanda ke sa ayyuka su fi inganci ga kamfanonin samar da wutar lantarki waɗanda ke kula da dubban wurare masu sauyawa.

Kayayyaki Masu Dorewa da La'akari da Muhalli

Sabbin abubuwa a cikin kayan lantarki suna faruwa ne ta hanyar ƙa'idodin gwamnati da alƙawarin kamfanoni na kasancewa masu aminci ga muhalli. Saboda ƙarancin sinadarin chromium mai siffar hexavalent, masana'antun suna canzawa zuwa shafa mai dacewa da muhalli maimakon tsoffin shafa mai canza chromate waɗanda aka yi amfani da su don kare shi daga tsatsa. Idan aka kwatanta da ƙarfe masu kama da juna, sassan ƙarfe na aluminum suna da sauƙi kuma suna ɗauke da ƙarancin carbon, amma har yanzu suna yin aikinsu a matsayin abubuwan gini. Tsarin zamani yana ba ku damar maye gurbin sassa maimakon jefar da dukkan na'urar, wanda ke tsawaita rayuwarta mai amfani kuma yana rage tasirin muhalli a duk tsawon rayuwarta.

Ka'idojin Tsaro Masu Sauyi da Daidaito a Duniya

Ka'idojin wutar lantarki na duniya suna canzawa koyaushe. Sabbin canje-canjen sun fi mai da hankali kan rage haɗarin walƙiya da cika buƙatun cancantar girgizar ƙasa. Matakin daidaita ƙa'idodin duniya tsakanin tsarin IEC da IEEE yana sauƙaƙa siyan abubuwa don ayyukan ƙasa da ƙasa ta hanyar barin saiti ɗaya na jagororin ya cika buƙatun yankuna daban-daban. Ingantawa ga makullan tsaro waɗanda ke dakatar da kunnawa ba zato ba tsammani yayin gyara ya dogara ne akan abin da aka koya daga binciken abubuwan da suka faru. Waɗannan suna kare ma'aikata ta hanyar matakan da aka tsara maimakon bin ƙa'idodi kawai.

makullan cire haɗin waje

Kammalawa

Zaɓar maɓallin cire haɗin waje saka hannun jari ne a cikin aminci, aminci, da inganci na cibiyar. Maganganu waɗanda suka daɗe tsawon shekaru ba tare da wata matsala ba sun bambanta da waɗanda ke buƙatar maye gurbinsu da wuri. Abubuwa mafi mahimmanci da za a nema su ne ƙimar ƙarfin lantarki da na yanzu waɗanda suka dace da buƙatun tsarin, juriya ga muhalli ta hanyar kayan aiki da rufin da aka gwada, da kuma bin ƙa'idodin ƙasashen duniya masu tsauri. Zane-zane na zamani, kamar GW5 High Voltage Disconnect Switch, suna da sassan da ba sa buƙatar kulawa, shaidar keɓewa ta gani, da zaɓuɓɓukan bin diddigin wayo waɗanda ke kare jarin ababen more rayuwa na gaba. Lokacin da manajojin sayayya, masu gudanar da kayan aiki, da masu haɗa tsarin suka san waɗannan sharuɗɗan zaɓi, za su iya zaɓar kayan aiki waɗanda ke kare mutane da kadarori yayin da suke rage farashin mallakar a tsawon rayuwar sabis.

FAQ

1. Za a iya amfani da makullan cire haɗin waje a tashoshin gidaje?

Makullan katsewa na waje a cikin tashoshin rarrabawa na gida galibi suna aiki a ƙananan ƙarfin lantarki (12-35kV), duk da cewa ana iya yin su a fasaha a mafi girman ƙarfin lantarki. Don amfanin gidaje, ƙananan girma da aiki ta atomatik wanda ke aiki tare da tsarin gudanar da rarrabawa sune mafi mahimmanci. A gefe guda kuma, tashoshin samar da wutar lantarki na masana'antu da na'urori masu amfani suna buƙatar ƙimar ƙarfin lantarki mafi girma da ikon kulle kayan aiki da hannu don amincin kulawa. Zaɓin ya dogara ne akan ƙarfin wutar lantarki na tsarin, adadin sararin da ake da shi, da takamaiman buƙatun kowane aikace-aikace.

2. Ta yaya Maɓallan Cire Hannu ke Bambanta da Masu Katsewar Da'ira a Aiki?

Cire makullan da ke cire haɗin suna yanke da'irori idan babu ko ƙaramar kaya a kansu, wanda hakan ke haifar da karyewar haske don aminci yayin gyara. Masu karya da'ira suna dakatar da kwararar matsala idan wani abu ya faru ba daidai ba kuma suna kashe tartsatsin wuta ta amfani da kayan aiki na musamman. Masu karya da masu yanke haɗin suna aiki tare don kiyaye abubuwa lafiya. Masu karya suna kare daga wuce gona da iri da kuma gajerun da'irori, kuma suna cire makullan da ke kiyaye abubuwa lafiya bayan masu karya sun share kurakurai. Amfani da maɓallin cire haɗin don ƙoƙarin dakatar da kwararar kaya na iya haifar da mummunan arc da lalacewa ga kayan aiki, wanda ke nuna muhimmancin bin matakan da suka dace a cikin tsari mai kyau.

3. Waɗanne Takaitattun Lokacin Dubawa ne Ka'idojin Masana'antu ke Ba da Shawara a Kai?

Ka'idojin IEEE da IEC sun ba da shawarar tsawon shekaru biyar na kulawa na yau da kullun don makullan katsewa na waje a ƙarƙashin yanayin aiki na yau da kullun, tare da duba nan take bayan lahani na tsarin ko abubuwan da suka faru na ɗan gajeren lokaci. Muhalli masu yawan gurɓatawa na iya buƙatar tsaftacewa kowace shekara don hana gurɓatar insulator. Ma'aunin juriyar hulɗa kowane shekaru 5-10 yana tabbatar da amincin haɗi, yayin da duba gani yayin sintiri na tashoshin ƙarƙashin ƙasa na yau da kullun yana gano lalacewa ko tsatsa bayyanannu da ke buƙatar kulawa. Kulawa bisa ga yanayi ta hanyar na'urori masu wayo suna ba da damar kulawa ta gaba wanda ke inganta lokacin dubawa bisa ga yanayin kayan aiki na ainihi maimakon jadawalin da aka tsara.

Yi aiki tare da Xi'an Xikai don samun ingantattun hanyoyin kariyar tashoshin wutar lantarki

Kamfanin Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. yana yin kayayyaki masu inganci sama da shekaru 40 kuma yana iya taimaka muku kare tashar samar da wutar lantarki ta ku. Mai samar da na'urar mu ta GW5 High Voltage Outdoor catch machine yana ba da tabbacin ingantaccen aiki tare da ginin galvanized mai zafi, tsarin akwatin gear na bakin karfe da sassan aluminum marasa kulawa waɗanda za su iya ɗaukar 72.5kV zuwa 126kV. Ana samar da na'urar mu ta ISO 9001, ta cika ka'idojin IEC 62271-102 da IEEE C37.32, kuma ana amfani da ita a ƙasashe sama da 50 a duniya. Wannan yana nufin za mu iya ba wa muhimman kayayyakin more rayuwa ilimin injiniya da samfuran da take buƙata. Aika imel zuwa serina@xaxd-electric.com , amber@xaxd-electric.com , ko luna@xaxd-electric.com don yin magana game da zaɓuɓɓukan siyayya na musamman, farashi mai gasa don manyan ayyuka, da ƙayyadaddun fasaha waɗanda aka yi don dacewa da buƙatun tashar samar da wutar lantarki.

makullan cire haɗin waje

References

1. Cibiyar Injiniyoyin Lantarki da Lantarki, "Ma'aunin IEEE don Sauyawar Wutar Lantarki Mai Girma: IEEE Std C37.32-2002," Ƙungiyar Ma'aunin IEEE, 2002.

2. Hukumar Fasaha ta Duniya ta Lantarki, "Mai Canja Wutar Lantarki Mai Girma da Kayan Kulawa - Kashi na 102: Masu Canja Wutar Lantarki da Masu Canja Wutar Lantarki," IEC 62271-102, Buga na 2018.

3. Zhang, Weiming, "Tsara da Amfani da Maɓallan Katse Haɗin Wutar Lantarki Mai Girma a Injiniyan Substation," Electric Power Press, Beijing, 2019.

4. Ƙungiyar Masana'antun Lantarki ta Ƙasa, "Rufe Kayan Aikin Lantarki (Matsakaicin Volts 1000)," NEMA Standards Publication 250, 2020.

5. Anderson, Paul M., "Kare Tsarin Wutar Lantarki," Jerin 'Yan Jarida na IEEE kan Injiniyan Wutar Lantarki, Wiley-IEEE Press, 2022.

6. Grigsby, Leonard L., "Injiniya a kan tashoshin samar da wutar lantarki: Bugu na Uku," CRC Press, Taylor & Francis Group, 2021.

Aika