samfurPic

Ƙananan ƙarfin lantarki na shunt capacitor-square

1. Ƙarfin Wutar Lantarki Mai Ƙimar (Ue): 100v ~ 1000v.
2. Shigarwa a Cikin Gida.
3. Kayan akwati takardar ƙarfe mai galvanized.
4. Kewayon fitarwa 10~100kvar.
5. Mitar mita 50/60Hz.
6.Connection sanyi D, Y, YN, III.
7.Terminal Block :M6, M8, M10 (Gwargwadon ƙarfin capacitor).
8. Rage tanδ <0.001 (20°C 50Hz).
9. Zafin jiki -25°C~50°C.
10. Mafi Girman Tsawo 2000m.
11. Ƙarfin capacitor (zuwa bango) ≥50mm.
12. Karkacewar Capacitance -5%~+10%.
aika Sunan
Download
  • Bayarwa da sauri
  • Quality Assurance
  • 24/7 Sabis na Abokin Ciniki

Product Gabatarwa

Ƙarfin Ƙarfin Wutar Lantarki Mai Ƙarfi - Maganin Ingancin Ƙwararren Wutar Lantarki

Product Gabatarwa

Mu Mai Ƙarfin Wutar Lantarki Mai Ƙarfin Wutar Lantarki yana wakiltar kololuwar fasahar diyya ta zamani ga tsarin wutar lantarki da ke aiki ƙasa da 1000V. Wannan na'urar gyara wutar lantarki mai siffar murabba'i mai ƙirƙira tana magance ƙalubalen masana'antu masu mahimmanci, gami da hukuncin amfani da wutar lantarki ga rashin kyawun wutar lantarki, rashin daidaiton wutar lantarki, da kuma tsadar makamashi mai yawa. Ba kamar ƙirar silinda ta gargajiya ba, mu Mai Ƙarfin Wutar Lantarki Mai Ƙarfin Wutar Lantarki Mai Ƙarfin Wutar Lantarki yana haɓaka ingancin sarari a cikin ƙananan shigarwa yayin da yake samar da ingantaccen aiki da aminci. An ƙera shi da fasahar fim ɗin polypropylene mai ƙarfe da ƙarfin warkarwa kai, wannan mafita yana ba wa wurin ku ingantaccen sarrafa ingancin wutar lantarki. (kalmomi 101)

An gina wannan capacitor don aikace-aikacen masana'antu da kasuwanci masu wahala, yana ba da fasaloli masu ƙarfi da aminci. Tsarin wutar lantarki ɗinku zai amfana daga ingantaccen ƙarfin lantarki, rage hukunce-hukuncen wutar lantarki mai amsawa, da kuma ingantaccen aiki gaba ɗaya.

Technical dalla

siga Ƙayyadaddun bayanai
Ƙimar Wutar Lantarki (Ue) 100V - 1000V
Installation Type na cikin gida
Matsalar abu Galvanized Karfe Sheet
Rage Fitar Wuta 10 - 100 kVar
Frequency 50 / 60 Hz
Kanfigareshan Haɗi D, Y, YN, III
Filin Garko M6, M8, M10 (Dogaro da Wutar Lantarki)
Factor Dissipation (tan δ) <0.001 (20°C, 50Hz)
Operating Temperatuur -25 ° C zuwa + 50 ° C
Matsakaicin Matsakaici 2000m
Mafi ƙarancin izinin shiga bango ≥50mm
Ikon haƙuri Mai haƙuri -5% zuwa +10%

Babban fasali da Fa'idodi

Tsarin da aka Inganta a Sarari : Tsarin siffar murabba'i yana kawar da ɓarnar sarari da aka saba gani a cikin shirye-shiryen silinda. Faifan sarrafawa naka suna samun yawan kVar mai yawa tare da ingantaccen watsar da zafi.

Fasaha Mai Waraka Kai : Fim ɗin polypropylene mai ƙarfe mai ƙarfi yana cire ƙananan kurakurai ta atomatik. Wannan yana tabbatar da ci gaba da aiki kuma yana tsawaita rayuwar sabis sosai.

Siffofin Tsaro Mafi Kyau : Na'urar cire haɗin matsi mai yawa da aka haɗa tana ba da damar keɓancewa ta atomatik a da'irar. Wurin aikinka yana nan a kare daga yiwuwar lalacewa.

Bin Ka'idojin Muhalli : Tsarin busasshiyar hanya yana kawar da haɗarin ɓullar mai. Wannan ya sa ƙarfin wutar lantarki mai ƙarancin wutar lantarki ya zama mai dacewa da muhalli masu laushi.

Daidaitaccen Gyaran Ƙarfin Wuta : Juriyar ƙarfin lantarki mai ƙarfi yana tabbatar da daidaiton diyya ga wutar lantarki mai amsawa. Farashin kuzarinka yana raguwa yayin da ingancin tsarin yake inganta.

Practical aikace-aikacen kwamfuta

Masana'antar Masana'antu : Ya dace da masana'antu masu manyan injinan induction, kayan aikin walda, da kuma na'urorin mita masu canzawa. Tsarin da aka tsara ya dace da bangarorin APFC da ake da su ba tare da wata matsala ba.

Gine-ginen Kasuwanci : Ya dace da cibiyoyin siyayya, asibitoci, da kuma ofisoshin da ke buƙatar ingantaccen wutar lantarki. Tsarin HVAC yana amfana daga ingantaccen kwanciyar hankali na wutar lantarki da rage yawan amfani da makamashi.

Cibiyoyin Bayanai : Yana da mahimmanci don kiyaye ingancin wutar lantarki a cikin yanayin sabar. Tsarin murabba'i yana inganta amfani da sararin rack yayin da yake tabbatar da ingantaccen aiki.

Tsarin Makamashi Mai Sabuntawa : Muhimmin sashi a cikin shigarwar hasken rana da iska don bin ka'idojin grid da kuma sarrafa wutar lantarki mai amsawa.

Ta yaya Yana Works

Capacitor mai ƙarancin ƙarfin lantarki yana haɗuwa daidai da nauyin wutar lantarki. Yana samar da wutar lantarki mai amsawa a cikin gida, yana rage bambancin lokaci tsakanin ƙarfin lantarki da wutar lantarki. Wannan yana inganta ƙarfin wutar lantarki daga ƙimar yau da kullun na 0.7-0.8 zuwa mafi kyawun matakan sama da 0.95.

Fim ɗin polypropylene mai ƙarfe yana adana makamashin lantarki a lokacin da ƙarfin lantarki ya kai kololuwa kuma yana sakin sa a lokacin zagayowar buƙata. Wannan musayar da ke ci gaba yana daidaita canjin ƙarfin lantarki kuma yana rage damuwa akan na'urorin canza wutar lantarki da na'urorin canza wutar lantarki.

Idan tsarinka ya jawo wutar lantarki mai amsawa, capacitor ɗin zai amsa nan take. Wannan yana kawar da buƙatar wutar lantarki mai amsawa da wutar lantarki ke bayarwa, yana rage kuɗin wutar lantarki da kuma inganta ingancin tsarin gaba ɗaya.

Ƙarfafa Ƙarfafawa

A Xi'an Xidian Medium and Low Voltage Electric Co., Ltd., muna kiyaye ƙa'idodi masu tsauri a duk lokacin samarwa. Tsarin masana'antarmu da aka ba da takardar shaidar ISO9001 yana tabbatar da daidaiton ingancin samfura da aminci.

Kowace na'urar capacitor tana fuskantar gwaje-gwaje masu tsauri, gami da tabbatar da ƙarfin dielectric, auna ƙarfin aiki, da kuma kimanta daidaiton yanayin zafi. Dabaru na zamani na samarwa suna tabbatar da ingantaccen aiki a cikin mawuyacin yanayi na masana'antu.

Ƙungiyarmu ta injiniya masu ƙwarewa tana ci gaba da inganta tsarin ƙira da masana'antu. Wannan alƙawarin yin aiki tuƙuru yana tabbatar muku da samun samfuran da suka wuce ƙa'idodin masana'antu.

Me ya sa Zabi Mu

Tabbataccen Tarihin Aiki : Tsawon shekaru da dama na gwaninta a masana'antar kayan aiki na matsakaici da ƙarancin wutar lantarki. Kayayyakinmu suna yi wa abokan ciniki hidima a fannoni daban-daban na duniya.

Cikakken Jerin Samfura : Daga tsarin 0.4kV zuwa 40.5kV tare da ƙimar yanzu har zuwa 4000A. Muna samar da cikakkun hanyoyin rarraba wutar lantarki don takamaiman buƙatunku.

Ƙwarewar Fasaha : Ƙungiyarmu ta injiniya tana ba da mafita na musamman da tallafin fasaha. Kuna samun jagorar ƙwararru a duk lokacin tsara da aiwatar da ayyuka.

Tabbatar da Inganci : Takaddun shaida sau uku (ISO9001, ISO14001, OHSAS18001) yana nuna jajircewarmu ga inganci, alhakin muhalli, da aminci.

FAQ

T: Menene tsawon rayuwar da ake tsammanin na Capacitor-square ɗinka mai ƙarancin wutar lantarki?

A: Idan aka shigar da kuma kula da shi yadda ya kamata, a yi tsammanin shekaru 15-20 na ingantaccen sabis. Fasahar warkar da kai tana tsawaita rayuwar aiki sosai idan aka kwatanta da na'urorin capacitor na gargajiya.

T: Shin waɗannan capacitors za su iya jure wa harmonic disorder?

A: Eh, idan aka haɗa su da na'urorin haɗa wutar lantarki masu dacewa, na'urorin haɗa wutar lantarki suna tace harmonics yadda ya kamata yayin da suke ba da gyaran wutar lantarki.

Tambaya: Menene kulawa ake buƙata?

A: Ana buƙatar ƙaramin kulawa. Duba gani na shekara-shekara da gwajin ƙarfin aiki lokaci-lokaci suna tabbatar da ingantaccen aiki.

T: Ta yaya zan tantance ƙimar kVar daidai don aikace-aikacena?

A: Ƙungiyarmu ta fasaha tana ba da nazarin kaya da ƙididdigar girman kaya. Tuntuɓe mu da takamaiman bayanan lantarki don shawarwari na musamman.

Tuntube Mu

Shin kuna shirye don inganta ingancin wutar lantarki da rage farashin makamashi? Ƙwararrun masana fasaha suna nan don taimaka muku zaɓar mafi kyawun mafita mai ƙarancin ƙarfin lantarki na Shunt Capacitor-square don aikace-aikacenku.

Don ƙarin bayani game da fasaha, ambato, da kuma shawarwari na ƙwararru, tuntuɓe mu a yau a serina@xaxd-electric.com.

Bari mu taimaka muku cimma ingantaccen gyaran wutar lantarki da ingantaccen ingantaccen tsarin ta hanyar amfani da fasahar capacitor da aka tabbatar.

Aika