huahanaPic

400V Metallurgical Self-Healing Capacitor

1. Alapine (frequency) 60Hz.
2. Ka ʻokoʻa o ka Capacitance -5% ~ + 10%.
3. ʻO kēia manawa kiʻekiʻe loa 2.5 × In.
Hoʻolako ʻia me nā mea pale hoʻokuʻu 4. Hoʻohui ʻia me nā polokalamu pale over-voltage kūʻokoʻa.
5. Hana ho'ōla pono'ī maika'i loa a me ke ola lawelawe lō'ihi.
6. Hoʻolālā ʻano maloʻo, kumu pohō haʻahaʻa me ke kūkulu ʻana me ka ʻole o ka leakage.
7. Hoʻolako ʻia me nā mea pale hoʻokuʻu.
  • Hāʻawi wikiwiki
  • mea e like ai ka oiaio
  • 24/7 lawelawe lawelawe

Product Introduction

400V Metallurgical Self-Healing Capacitor

Product Introduction

Hōʻike ka 400V Metallurgical Self-Healing Capacitor i kahi holomua i ka ʻenehana hoʻoponopono kumu mana. Hoʻohana kēia ʻāpana uila holomua i nā kaʻina hana hoʻokaʻawale vacuum kūikawā e hana i nā hopena mana hilinaʻi a palekana no nā noi ʻoihana. E ʻike ʻoe e hāʻawi kēia capacitor i ka hana maikaʻi loa i hoʻohālikelike ʻia me nā ʻāpana piha ʻaila kuʻuna. Loaʻa i kā mākou capacitor nā hiki ke hoʻōla ponoʻī holomua e hoʻokaʻawale koke i nā hewa a hoʻihoʻi i ka hana i loko o nā microseconds. Hoʻopau kēia hoʻolālā hou i nā hemahema catastrophic me ka hāʻawi ʻana i ka uku mana reactive paʻa i nā wahi uila paʻakikī.

I kūkulu ʻia no nā ʻano ʻoihana koi, ʻoi aku ka maikaʻi o kēia capacitor i nā noi e pono ai ka hoʻoponopono ʻana i ka mana mana mau. Loaʻa iā ʻoe nā hiʻohiʻona palekana i hoʻonui ʻia, ke ola lawelawe i hoʻolōʻihi ʻia, a me ka hana mālama ʻole. Hoʻopau ke kūkulu ʻano maloʻo i nā pilikia leakage me ka hāʻawi ʻana i ka hana wela maikaʻi loa.

Nā Kūlana Kiʻi

aiao hoakaka
Loipālākiō anakahi uila 400V AC
'O ka pinepine 50 / 60Hz
Hoʻolālā Manaʻo -5% a i +10%
Loaʻa Loa 2.5 × Manawa i helu ʻia
Dissipation ololi ≤0.2W/kvar ma 50Hz
pae'ōnaehana Mahana -25 ° C a + 70 ° C
Pūnaewele lawelawe > 100,000 mau hola
Mea Dielectric ʻO ke kiʻiʻoniʻoni Polypropylene i hoʻoheheʻe ʻia
Ke ʻano palekana Mea Hoʻokaʻawale Overpressure
Nā Kūlana Hoʻoponopono IEC 60831-1/2, EN 60252-1

Nā mea nui a me nā pono

ʻenehana ho'ōla pono'ī holomua

Hoʻokumu kā mākou hana hoʻoheheʻe hakahaka metallurgical i kahi papa Zinc-Aluminum alloy nano-mānoanoa. Ke piʻi ka voltage, hoʻomake koke ka ikehu arc i ka electrode a puni nā wahi hewa. Hoʻokaʻawale kēia i nā hemahema a hoʻihoʻi i ka hana maʻamau.

Hoʻolālā Palekana Hoʻonui

Hāʻawi ka mea hoʻokaʻawale overpressure i hoʻohui ʻia i ka palekana mechanical. Inā piʻi ke kaomi kūloko ma muli o nā kūlana pau ʻole o ke ola, hoʻokaʻawale kino kēia hiʻohiʻona palekana i ke kaapuni. Pale ʻoe i nā pahū weliweli a me nā pōʻino ahi.

Ke kūkulu ʻia ʻana

Hoʻopau ka hoʻolālā ʻano maloʻo i nā pōʻino kaiapuni e pili ana i nā ʻāpana i hoʻopiha ʻia me ka ʻaila. Hāʻawi ke kūkulu ʻana i hoʻokomo ʻia i ka resin i ke kūpaʻa maikaʻi loa i ka makū. Hāʻawi ke ʻano cylindrical i ka hoʻolaha wela maikaʻi loa no nā hoʻonohonoho kiʻekiʻe.

ʻO ke ola lawelawe lōʻihi

Hoʻopau maʻemaʻe nā pilina metallurgical kiʻekiʻe me ka waiho ʻole ʻana i nā ala kalapona conductive. Hoʻolōʻihi kēia i ke ola hana ma mua o 100,000 mau hola ma lalo o nā kūlana kūpono. Makemake ʻoe i nā kumukūʻai mālama i hoʻemi ʻia a me ka hilinaʻi o ka ʻōnaehana i hoʻomaikaʻi ʻia.

Nā Manawa Kūpono

Nā ʻōnaehana hoʻoponopono kumu mana

Hoʻohana nā hale hana ʻoihana i kā mākou mau capacitors e hoʻomaikaʻi i ka mana mana a hoʻopau i nā hoʻopaʻi pono. Loaʻa i nā hale hana hana, nā kikowaena ʻikepili, a me nā hale kalepa ka mālama ikehu nui.

Nā noi hoʻomaka motika

Loaʻa ka pōmaikaʻi o nā motika AC mai nā ʻano hoʻomaka i hoʻomaikaʻi ʻia a me ka hoʻemi ʻia o nā kahe komo. Hāʻawi kā mākou mau capacitors i ke kākoʻo paʻa no nā ukana loli a me nā hana hoʻomaka-hoʻōki pinepine.

Nā Hoʻonā ʻOihana Metallurgical

Hilinaʻi nā wili kila, nā mea hoʻoheheʻe alumini, a me nā hale hana hao i kā mākou mau capacitors no ka uku mana reactive kūlike. Hoʻokele ka hoʻolālā paʻa i nā wahi ʻoihana koʻikoʻi me nā loli wela koʻikoʻi.

Nā Kaiapuni Waiwai Harmonic

Ke hoʻohui ʻia me nā reactors detuning, hoʻokele pono kēia mau capacitors i ka distortion harmonic i nā hale hana ʻoihana hou me nā drive alapine loli a me nā ukana uila.

Pehea It na hana

Hana ka 400V Metallurgical Self-Healing Capacitor ma o ka ʻenehana kiʻiʻoniʻoni metallized holomua. Loaʻa i ka kiʻiʻoniʻoni dielectric polypropylene nā electrodes zinc-aluminum i waiho ʻia i ka vacuum e hana ana i ka element capacitive.

I ka wā hana maʻamau, mālama ka capacitor a hoʻokuʻu i ka ikehu reactive e hoʻomaikaʻi i ka mana mana. Ke hana ʻia ka haki ʻana o ka dielectric, hoʻāla koke ka ʻōnaehana ho'ōla ponoʻī. Hoʻomake ka ikehu hewa i ka uhi metala a puni ka wahi haki, e hana ana i kahi ʻāpana insulating.

Ke hoʻomau nei ka hana o ka capacitor me ka capacitance i hoʻemi iki ʻia akā mālama ʻia ka hana. Hiki i kēia kaʻina hana ke hana hou i nā tausani manawa i loko o ke ola lawelawe. Nānā ka ʻōnaehana palekana overpressure i nā kūlana kūloko a hoʻokaʻawale i ka ʻāpana inā ʻoi aku ke kaomi kinoea ma mua o nā palena palekana.

Ka Hana Hana Hou

Ma Xi'an Xidian Medium and Low Voltage Electric Co., Ltd., mālama mākou i nā kūlana maikaʻi koʻikoʻi ma o ka hana ʻana. Hoʻokomo pū kā mākou kaʻina hana i nā protocol hoʻāʻo piha no ka hōʻoia uila, ka hōʻoia ho'ōla ponoʻī, a me ka hōʻoia ʻana o ka mīkini palekana.

Hana mākou i nā hoʻāʻo uila maʻamau mai ka terminal a i ka terminal ma 2.15 mau manawa o ka uila i helu ʻia. Hoʻopili ka hoʻāʻo insulation ma luna o 3000V AC ma waena o nā terminal a me ka hihia. Hōʻoia nā hoʻāʻo haki i manaʻo ʻia i ka hana ho'ōla ponoʻī me ka emi ma mua o 1% ka pohō capacitance.

Hoʻohālikelike kā mākou hoʻāʻo hoʻomanawanui i nā anakahi i 1.25 mau manawa o ke anakahi uila ma ka mahana kiʻekiʻe loa no 2,000 mau hola. Hoʻohālike kēia i ka hōʻino ʻana o ke kaʻina hana ola a hōʻoia i ke kūpaʻa o ka zinc-aluminum alloy.

No ke aha e koho ai iā mākou

ʻIke ʻoihana i hōʻoia ʻia

Me nā ʻano huahana he 100 a ʻoi ma nā moʻo he 34, maopopo iā mākou nā koi ʻoihana like ʻole. Lawelawe kā mākou mau hoʻonā i nā mea kūʻai aku mai 0.4kV a i 40.5kV mau noi me nā au a hiki i 4000A.

Nā palapala hoʻomaikaʻi e like ai

Mālama mākou i ka hoʻokele maikaʻi ISO9001, ka hoʻokele kaiapuni ISO14001, a me nā palapala hōʻoia palekana OHSAS18001. Hoʻokō mau kā mākou huahana i nā kūlana aupuni a me ka honua.

Laulā Huahana piha

Ma waho aʻe o nā capacitors, hāʻawi mākou i nā hoʻonā hoʻolaha mana piha e pili ana i nā switchgear, nā transformers, a me nā mea haki kaapuni. Loaʻa iā ʻoe ka pōmaikaʻi mai ka hoʻolālā ʻōnaehana i hoʻohui ʻia a me ke kuleana kumu hoʻokahi.

Mea Hana Hou

Ma ke ʻano he poʻe komo i nā papahana aupuni 863, hoʻopukapuka nui mākou i ka noiʻi a me ka hoʻomohala ʻana. Hoʻolauna mau kā mākou hui ʻenekinia i nā ʻenehana a me nā mea hou e hoʻomaikaʻi i ka hana huahana.

Nīnau Hoʻoholo Pine

Q: Pehea ka lōʻihi o ke kaʻina hana ho'ōla pono'ī?

A: Hoʻāla ʻia ke ʻano ho'ōla ponoʻī i loko o nā microseconds o kahi hanana haki. Hoʻoheheʻe koke ʻia ka uhi metala, e hoʻokaʻawale ana i ka hewa a hoʻihoʻi hou i ka hana maʻamau.

Q: Hiki iaʻu ke hoʻohana i kēia capacitor i nā wahi harmonic kiʻekiʻe?

A: No nā noi waiwai harmonic, e hoʻopili i ka capacitor me nā reactors anti-resonance. E noʻonoʻo i nā helu voltage kiʻekiʻe (440V a i ʻole 525V) e lawelawe i ka piʻi ʻana o ka voltage mai ka ʻike harmonic.

Q: Pehea e ʻike ai au i ka wā e pono ai ke pani ʻia ka capacitor?

A: E nānā mau i nā pae capacitance. ʻO ka emi ʻana o 5-10% mai ka waiwai mua e hōʻike pinepine ana i ka kokoke ʻana o ka hopena o ke ola. E hoʻāla ʻia ka mea hoʻokaʻawale overpressure no ka palekana.

Q: He aha ka mālama e pono ai?

A: He mau ʻāpana mālama ʻole kēia. E hana i nā nānā maka manawa a me nā ana capacitance. E hōʻoia i ka noho ʻana o nā mahana ambient i loko o nā palena i kuhikuhi ʻia no ke ola lawelawe kūpono loa.

Kāhea iā mā˚ou

Mākaukau e hoʻomaikaʻi i kāu ʻōnaehana hoʻoponopono kumu mana? Kū mākaukau kā mākou hui loea e kōkua iā ʻoe e koho i ka 400V Metallurgical Self-Healing Capacitor kūpono no kāu noi kikoʻī.

E kelepona i kā mākou hui kūʻai aku no nā kikoʻī kikoʻī, nā kumukūʻai, a me ka ʻike hoʻouna. Hāʻawi mākou i ke kākoʻo loea piha mai ke kūkākūkā mua ʻana a hiki i ke kau ʻana a me ke kauoha ʻana.

Leka uila: serina@xaxd-electric.com

E ʻae mai iā mākou e kōkua iā ʻoe e hoʻokō i ka maikaʻi o ka mana, ka hoʻemi ʻana i nā kumukūʻai ikehu, a me ka hilinaʻi o ka ʻōnaehana i hoʻomaikaʻi ʻia me kā mākou mau hoʻonā capacitor holomua.

hoouna aku