50KVAR Mea Ho'ōla Ponoi no ka PFC(Power Factor correction)-square BKMJ
Panakō Uku Mana Reactive
2. Ka ʻokoʻa o ka Capacitance -5% ~ + 10%.
3. ʻO kēia manawa kiʻekiʻe loa 2.5 × In.
Hoʻolako ʻia me nā mea pale hoʻokuʻu 4. Hoʻohui ʻia me nā polokalamu pale over-voltage kūʻokoʻa.
5. Hana ho'ōla pono'ī maika'i loa a me ke ola lawelawe lō'ihi.
6. Hoʻolālā ʻano maloʻo, kumu pohō haʻahaʻa me ke kūkulu ʻana me ka ʻole o ka leakage.
7. Hoʻolako ʻia me nā mea pale hoʻokuʻu.
- Hāʻawi wikiwiki
- mea e like ai ka oiaio
- 24/7 lawelawe lawelawe
Product Introduction
Panakō Uku Mana Reactive - Nā Hoʻonā Mana Mana ʻOihana
Product Introduction
Ke hakakā nei ʻoe me nā hoʻopaʻi mana mana haʻahaʻa a me nā ʻōnaehana uila kūpono ʻole? ʻO kā mākou Reactive Power Compensation Bank kāu hopena no ka hoʻomaikaʻi ʻana i ka maikaʻi o ka mana a me ka hōʻemi ʻana i nā kumukūʻai hana. Hoʻohui kēia ʻaha uila holomua i nā capacitors hana kiʻekiʻe, nā reactors damping, a me ka ʻenehana hoʻololi akamai e hāʻawi i ka hoʻoponopono mana mana kiʻekiʻe.
Hoʻokomo kā mākou mau panakō uku i ka mana reactive capacitive e pale aku i nā ukana inductive mai nā motika a me nā mea hoʻololi. E ʻike koke ʻoe i nā pono e pili ana i ka hoʻemi ʻana i nā hoʻopaʻi pono, ka hoʻomaikaʻi ʻana i ke kūpaʻa voltage, a me ka hoʻonui ʻana i ka pono o ka ʻōnaehana. Loaʻa i kēlā me kēia Panakō Uku Mana Reactive nā mea hoʻokele aunoa e hoʻoponopono dynamically i ka capacitance e pili ana i nā kūlana ukana manawa maoli.
I kūkulu ʻia no nā ʻano ʻoihana koi, hāʻawi kā mākou mau ʻāpana i ka hana hilinaʻi me ka hoʻokō ʻana i nā kūlana honua. Loaʻa iā ʻoe ka ʻenehana i hōʻoia ʻia e hoʻoponopono pono i kāu mau pilikia maikaʻi mana.
Nā Kūlana Kiʻi
| aiao | hoakaka |
|---|---|
| Loipālākiō anakahi uila | 0.4kV - 35kV |
| 'O ka pinepine | 50 / 60Hz |
| Loaʻaʻia kēia | 630A - 4000A |
| Hoʻolālā Manaʻo | -5% a i +10% |
| Loaʻa Loa | 2.5 × I loko |
| Dielectric Loss Factor | ≤ 0.2W/kVAR |
| pae'ōnaehana Mahana | -25 ° C a + 55 ° C |
| Kumu Hoʻokaʻawale | 7% / 14% (koho) |
| Papa Pale | IP54 / IP65 |
| Papa Pākuʻi | Papa B/F |
| Nā Kūlana Hoʻoponopono | IEC 60831, IEC 61921, IEC 61439 |
Nā mea nui a me nā pono
ʻenehana ho'ōla pono'ī holomua
Loaʻa i kāu ʻōnaehana ka pōmaikaʻi mai nā capacitors kiʻiʻoniʻoni polypropylene i hoʻoheheʻe ʻia me nā waiwai ho'ōla ponoʻī kiʻekiʻe. Hoʻolōʻihi kēia i ke ola lawelawe me ka mālama ʻana i ka hana mau.
Nā Koho Hoʻololi Akamai
E koho ma waena o ka hoʻololi ʻana o ka contactor no nā ukana paʻa a i ʻole ka hoʻololi ʻana o ka thyristor no nā loli ukana wikiwiki. Loaʻa iā ʻoe ka mana pololei me nā transients liʻiliʻi.
Ka Palekana Harmonic
Pale aku nā reactors detuned i hoʻohui ʻia i ka distortion harmonic. Pale kēia i nā pilikia resonance e hiki ke hōʻino i kāu lako a hoʻopilikia paha i nā hana.
Nā hiʻohiʻona palekana piha
Hōʻoia nā mea pale hoʻokuʻu i kūkulu ʻia i loko i nā kaʻina hana mālama palekana. Mālama nā mea pale over-voltage i kāu hoʻopukapuka kālā mai nā piʻi uila.
Hoʻolālā Modular
ʻO kā mākou hoʻonohonoho maʻalahi e ʻae i ka hoʻonui maʻalahi ʻana i ka wā e ulu ai kāu mau koi mana. Hiki iā ʻoe ke hoʻohui i ka mana me ka ʻole o ka hoʻololi ʻana i nā lako e kū nei.
Nā Manawa Kūpono
hanalima Manufacturing
Loaʻa ka pōmaikaʻi i nā wili kila a me nā ʻoihana kaumaha mai kā mākou mau hoʻonā Reactive Power Compensation Bank . Hoʻokele pono nā ʻano like ʻole i hoʻololi ʻia e thyristor i nā loli wikiwiki o ka ukana mai nā umu arc a me nā motika nui.
ʻIkepili-oaio? a
Pono nā ʻōnaehana harmonic kiʻekiʻe i nā panakō uku hoʻokaʻawale kūikawā. Hōʻalo ʻoe i nā pilikia resonance me ka mālama ʻana i ka mana kūpono i nā hale IT.
Hoʻohui hou i nā ʻōnaehana
Hoʻohana nā kikowaena makani a me ka lā i kā mākou mau panakō e hoʻokō i nā koi code grid. Hiki ke mālama ʻia ka paʻa ʻana o ke au uila ma luna o nā laina hoʻoili lōʻihi.
Na Hale Kalepa
Hoʻokumu nā ʻōnaehana HVAC a me nā ukana kukui i nā pilikia kumu mana. Mālama kā mākou uku hana ponoʻī i ka pono me ka hoʻemi ʻana i nā uku koi.
Pehea It na hana
Hana ka Reactive Power Compensation Bank ma ka nānā mau ʻana i ka mana kumu o kāu ʻōnaehana. Ke hana nā ukana inductive i ka mana kumu lohi, hoʻoikaika ka mea hoʻokele aunoa i nā ʻanuʻu capacitor.
ʻO kēia hoʻokomo ʻana o ka mana reactive alakaʻi e hoʻokokoke aku i kāu kumu mana i ka lokahi. Loaʻa iā ʻoe ke kaulike kūpono ma waena o ka hoʻohana ʻana i ka mana maoli a me ka mana reactive.
Pale aku nā mea hoʻokele akamai i ka uku nui ʻana ma o ke hoʻololi ʻana i nā capacitors i loko a i waho e pili ana i nā koi maoli. Hōʻoia kēia pane ikaika i ka maikaʻi o ka mana mau me ka nānā ʻole i nā ʻokoʻa o ka ukana.
Mālama ka hoʻolālā reactor detuned i ka hoʻonui harmonic me ka mālama ʻana i ka pono o ka uku. Hana palekana kāu ʻōnaehana ʻoiai i nā wahi uila i hoʻopilikia ʻia.
Ka Hana Hana Hou
Lawe mai ʻo Xi'an Xikai Medium And Low Voltage Electric Co., Ltd. i nā makahiki he ʻumi o ka ʻike loea i kēlā me kēia panakō uku. ʻO kā mākou mau kaʻina hana hana i hōʻoia ʻia e ISO 9001 e hōʻoiaʻiʻo i ka maikaʻi a me ka hilinaʻi mau.
Hoʻohana mākou i nā kaʻina hana hoʻāʻo holomua e komo pū ana me nā hoʻāʻo insulation voltage kiʻekiʻe a me ka hōʻoia ʻana i ka piʻi ʻana o ka mahana. Hoʻomaʻamaʻa ʻia kēlā me kēia ʻāpana i ka hoʻāʻo ʻae ʻia e ka hale hana ma mua o ka lawe ʻana.
Hoʻolālā kā mākou hui ʻenekinia i nā hoʻonā i hana kūikawā ʻia no kāu mau noi kikoʻī. Loaʻa iā ʻoe nā lako i hoʻonohonoho pono ʻia no kāu mau kūlana hana a me nā koi hana.
ʻO nā mea hana maikaʻi a me nā ʻano hana hōʻuluʻulu pololei e hana i nā huahana e ʻoi aku ma mua o nā kūlana ʻoihana. Hāʻawi kāu hoʻopukapuka kālā i ka waiwai lōʻihi ma o ka hana hilinaʻi.
No ke aha e koho ai iā mākou
Palapala Track hōʻoia
Hana pono kā mākou mau panakō uku ma nā ʻoihana like ʻole. Loaʻa iā ʻoe ka pōmaikaʻi mai nā hoʻolālā i hoʻāʻo ʻia ma ke kahua a me ka hoʻomaikaʻi mau ʻana ma muli o ka ʻike maoli.
kōmike Support
Hāʻawi nā ʻenekinia akamai i ke kōkua piha mai ka helu ʻana i ka nui a hiki i ke kākoʻo komisina. Loaʻa iā ʻoe ke alakaʻi e pono ai no ka hana maikaʻi loa o ka ʻōnaehana.
Nā Mana Hoʻopilikino
Hoʻokō nā huahana maʻamau i ka hapa nui o nā koi, akā ʻoi aku mākou ma mua o nā hoʻonā maʻamau. Loaʻa i kāu mau pilikia kūikawā ka nānā kūikawā a me nā ʻano hana hou.
Palapala Hoʻopiha piha
Mālama ka uhi palapala hoʻokō ākea i kāu hoʻopukapuka kālā. ʻOi aku kā mākou kūpaʻa i ka maikaʻi ma mua o ka lawe mua ʻana a me ke kau ʻana.
Nīnau Hoʻoholo Pine
Q: He aha ka ʻokoʻa ma waena o ka contactor a me ka thyristor switching?
A: Kūpono ka hoʻololi ʻana o ka contactor i nā ukana paʻa e like me nā ʻōnaehana HVAC. Pane ka hoʻololi ʻana o Thyristor i loko o 20ms no nā ukana e loli wikiwiki ana e like me nā lako hana kuʻihao.
Q: Pehea ʻoe e pale aku ai i ka harmonic resonance?
A: Hoʻonui nā reactors i hoʻokaʻawale ʻia i ka impedance ma nā alapine harmonic. ʻO ka 7% detuning factor e ālai i nā harmonics kauoha 5 a ʻoi aku ka maikaʻi.
Nīnau: He aha kāu papa hana mālama?
A: Uhi nā nānā ʻana ʻelua makahiki i nā pilina busbar, ka hoʻomaʻemaʻe kānana, a me ka hōʻoia ʻana o ka capacitance. Hōʻoia kēia papa hana i ka hana kūpono a me ke ola lōʻihi.
Q: Hiki i ka panakō ke hana ma nā wahi harmonic kiʻekiʻe?
A: ʻAe, e kuhikuhi i nā waihona uku hoʻokaʻawale ʻia a i ʻole ke kānana. Hoʻokomo pū kēia me nā reactors moʻo e pale ana i ka pōʻino mai ka harmonic distortion.
Kāhea iā mā˚ou
Ua mākaukau ʻoe e hoʻomaikaʻi i kāu kumu mana a hoʻēmi i nā kumukūʻai uila? Ua mākaukau kā mākou hui loea e kālailai i kāu mau koi a hāʻawi i ka ʻōlelo aʻoaʻo no ka hopena uku kūpono loa.
E kāhea mai iā mākou i kēia lā no nā kikoʻī kikoʻī, nā kumukūʻai, a me ke kākoʻo ʻenekinia noi. E ʻae i ko mākou ʻike loea e kōkua iā ʻoe e hoʻokō i ka mana kiʻekiʻe a me ka pono hana.
Leka uila: serina@xaxd-electric.com
E hoʻololi i ka hana o kāu ʻōnaehana uila me kā mākou ʻenehana Reactive Power Compensation Bank i hōʻoia ʻia . Ua kū kāu mau pilikia maikaʻi mana i kā lākou kūlike.
hoouna aku ana

_1794452994801.jpg)
_1794454101944.jpg)