Puas Yog Lub Transformer Hauv Tsev Yuav Txo Tau Qhov Kev Pheej Hmoo Ntawm Kev Tso Tawm Ib Nrab?

2026-11-12 17:22:01

Yog, tab sis tsuas yog nyob rau hauv cov kev txwv. Lub tshuab hloov pauv tam sim no sab hauv tsev tsis tuaj yeem tshem tawm qhov tso tawm ib nrab (PD) ntawm nws tus kheej. Txawm li cas los xij, ib chav tsev ua zoo nrog cov rwb thaiv tsev epoxy tsis muaj qhov khoob, cov qauv hluav taws xob du, thiab cov vaj huam sib luag kom raug tuaj yeem txo qhov kev pheej hmoo ntawm PD ntau heev. PD yog qhov kev puas tsuaj hauv zos uas tsis txuas qhov sib txawv ntawm ob tus neeg coj, thiab dhau sijhawm nws tuaj yeem hnav cov rwb thaiv tsev hauv cov khoom siv hluav taws xob nruab nrab. Hauv phau ntawv qhia no, kuv piav qhia txog yuav ua li cas lub cuab yeej ua haujlwm, yuav ua li cas tsim thiab sim tswj PD, thiab yuav ua li cas cov khoom siv hloov pauv OEM tuaj yeem xaiv tus qauv 24kV. Cov qauv xws li IEC 60270 thiab IEC 61869-2 teeb tsa cov cai rau kev ntsuas thiab kev ua tau zoo.

 sab hauv tsev tam sim no transformer
 
​​​​​​​​​​​​​​ sab hauv tsev tam sim no transformer

Lub Transformer Sab Hauv Tsev Yog Dab Tsi Thiab Nws Ua Haujlwm Li Cas?

Yuav Ua Li Cas Lub Transformer Hauv Tsev Scales Current

Kev siv hluav taws xob hluav taws xob yog li cas lub tshuab hloov hluav taws xob sab hauv tsev ua haujlwm. Thaum cov hluav taws xob tseem ceeb ntws los ntawm cov hlau, cov hluav taws xob sib nqus sib sau ua ke hauv lub plawv. Cov hluav taws xob sib npaug ntws los ntawm cov cua ntsawj thib ob vim yog cov hluav taws xob ntawd. Cov hluav taws xob no muab zog rau cov ntsuas, cov hloov pauv kev nyab xeeb, lossis cov khoom siv saib xyuas. Lub tshuab 1000/1 A hloov 1000 A ntawm cov hluav taws xob tseem ceeb mus rau 1 A ntawm lub cuab yeej. Qhov no yog vim tias cov ntsuas theem nrab yog 5 A lossis 1 A. Qhov no ua rau cov xov hlau theem nrab nyob deb ntawm cov xov hlau uas nqa hluav taws xob nruab nrab. Koj yuav tsum tsis txhob tso qhov hluav taws xob theem nrab qhib, vim tias qhov hluav taws xob tuaj yeem tsim thoob plaws nws cov davhlau ya nyob twg thiab ua rau muaj kev phom sij heev. Qhov tseeb ntawm lub 'meter' lossis relay nyeem ntawv yog raws li qhov yuam kev piv thiab qhov yuam kev theem ntawm qhov kev ntsuas no.

Cov Cheebtsam Tseem Ceeb Hauv Tsev

Lub tshuab hloov pauv tam sim no sab hauv tsev uas siv cov hlau nplaum cam khwb cia muaj tus neeg hlau tseem ceeb, ib lossis ntau lub hlau nplaum sib nqus, cov xov hluav taws xob theem ob, cov rwb thaiv tsev epoxy, thiab kev sib txuas nrog qhov chaw los tso lub tshuab hloov pauv. Qhov sib piv me me thiab qhov yuam kev theem yog qhov uas cov hlau ntsuas sim tshem tawm, thaum cov hlau tiv thaiv yuav tsum ua kom raug txawm tias muaj teeb meem tam sim no. Cov khoom siv tseem ceeb. Thaum nws los txog rau kev tiv thaiv, cov hlau silicon tuaj yeem ua tau qhov ceev ntawm cov dej ntws siab dua, thaum cov hlau nanocrystalline lossis microcrystalline muab cov permeability siab rau kev ua haujlwm tam sim no qis. Lub chav tsev 24kV uas Xi'an Xikai ua yog ua los ntawm cov hlau silicon zoo thiab cov xov tooj liab. Xa koj daim duab kos thiab qhov kev thov rau cov khoom siv tseem ceeb sib txawv. Peb cov kws tshaj lij yuav saib nws thiab teb rov qab rau koj.

Qhov twg Chav Nyob Hauv Nruab Nrab-Voltage Switchgear

Lub tshuab hluav taws xob sab hauv tsev nyob hauv lub thawv hlau ntawm 1 kV txog 52 kV switchgear uas tau them los ntawm IEC 62271-200. Nws nyob hauv lub feeder, busbar, lossis breaker compartment. Vim tias nws nyob ze rau busbars, cable terminations, thiab voltage transformers, txoj kev uas nws zoo li cas, txoj kev uas nws cov bolts tau teeb tsa, thiab qhov deb ntawm nws cov rwb thaiv tsev txhua yam cuam tshuam rau PD ua haujlwm li cas. Yog tias lub tshuab hluav taws xob sab hauv tsev tsuas yog haum los ntawm ob peb millimeters, tej zaum yuav tsis muaj qhov chaw cua ntau npaum li qhov tsim vaj huam sib luag xav tias yuav muaj. Ua ke, ua ntej thawj qhov qauv, saib daim duab kos transformer sab hauv tsev thiab daim duab kos txee. Tsis txhob saib lawv ib qho tom qab ib qho. Rau cov neeg tsim khoom OEM, qhov kev kuaj xyuas ntawd tuaj yeem txuag lawv ntau lub sijhawm thiab nyiaj txiag.

Yuav Ua Li Cas Thiaj Tsim Tau Transformer Hauv Tsev Kom Txo Tau Qhov Kev Pheej Hmoo Ntawm Kev Tso Tawm Ib Nrab?

Kev Tswj Xyuas Qhov Zoo thiab Kev Tsis Muaj Dab Tsi

Qhov tsis muaj dab tsi yog ib qho ua rau PD hauv cov resin cam khwb cia. Lub zog dielectric ntawm lub hnab cua qis dua li ntawm cov epoxy khov kho nyob ib puag ncig nws. Qhov no txhais tau tias lub zog hluav taws xob tuaj yeem sib sau ua ke ntawd thiab ua rau muaj cov pa tawm me me pib. Kev nqus cov roj hmab degassing, sib tov nws kom raug, tswj cov txheej txheem hardening, thiab xyuas kom meej tias thaj chaw tsim khoom huv thiab qhuav txhua yam pab txo qhov kev pheej hmoo ntawm cov voids. Cov windings nyob qhuav thiab huv si vim tias lub cev epoxy tau kaw tag nrho. Rau nws lub 24kV sab hauv tsev transformer tam sim no, Xi'an Xikai hais tias qhov kev tso tawm ib nrab yog tsawg dua 10 pC ntawm 24 kV. Koj tuaj yeem piv tus lej no rau qhov koj xav tau. Nug txhua tus neeg muag khoom seb lawv xam tus lej ntawd li cas.

Kev Tswj Xyuas Thaj Chaw, Qib Kev Rwb Thaiv Tsev, thiab Kev Tshem Tawm

Lub zog hluav taws xob tsom mus rau ntawm cov chaw ntxhib, cov npoo ntse ntawm tus neeg coj hluav taws xob, thiab cov phab ntsa nyias ntawm cov rwb thaiv tsev. Txhawm rau kom txo qis kev ntxhov siab, cov neeg tsim qauv ua kom cov npoo sib npaug, ua kom du ntawm qhov chaw casting, ntxiv cov ntaub thaiv qhov twg nws xav tau, thiab xyuas kom meej tias cov rwb thaiv tsev yog qhov tuab rau qhov voltage rated. Lub transformer tam sim no sab hauv tsev kuj yuav tsum phim qhov kev sib koom ua ke ntawm lub vaj huam sib luag rwb thaiv tsev, uas suav nrog qhov sib txawv ntawm huab cua, qhov voltage rated, theem tiv taus, thiab qhov deb ntawm creepage. Kev nyeem ntawv qis ntawm lub rooj zaum sim rau lub transformer tam sim no sab hauv tsev yuav tsis txhais li cas yog tias lub vaj huam sib luag nyob ze rau lub busbar. Pab neeg tuaj yeem nrhiav cov chaw muaj kev ntxhov siab nrog kev pab los ntawm daim duab kos uas qhia txog lub cev transformer tam sim no sab hauv tsev, tus neeg coj hluav taws xob tseem ceeb, cov cores, cov txheej rwb thaiv tsev, thiab cov ntsiab lus mounting.

Dab tsi ua rau muaj kev tawm ib feem ntawm lub cev nyob ib puag ncig CT

Feem ntau, PD nyob ib puag ncig lub tshuab hloov pauv tam sim no sab hauv tsev mus rau ib qho ntawm peb pawg. Nov yog li cas kuv teeb tsa cov teeb meem teb:

  • Qhov tsis zoo ntawm kev tsim khoom: Cov qhov tsis muaj zog hauv cov rwb thaiv tsev yog tshwm sim los ntawm tej yam xws li cov pa npuas, cov kab nrib pleb, cov khoom tawg, cov roj hmab tsis sib txuas zoo, thiab tsis qhuav txaus. Tib txoj hauv kev los nrhiav cov qhov tsis zoo no thaum ntxov, ua ntej lub tshuab mus txog koj lub vaj huam sib luag thiab siv tau, yog los ntawm kev tswj cov txheej txheem ntawm cov neeg xa khoom thiab kev sim PD ntawm lub Hoobkas.
  • Yuam Kev Teeb Tsa: Kev rwb thaiv tsev puas tsuaj, kev sib txuas xoob, tsis muaj qhov chaw txaus ntawm cov khoom, kev sib txuas hauv av tsis raug, plua plav, thiab dej noo txhua yam ua rau muaj kev pheej hmoo ntawm PD tom qab sib dhos. Thaum cov xov hlau hnyav rub rau ntawm cov terminals, lawv tuaj yeem tawg cov resin ze. Vim li no, kev xa xov hlau thiab cov nqi torque yuav tsum tau saib xyuas kom zoo thaum lub sijhawm tsim vaj huam sib luag, kev tshuaj xyuas zaum kawg, thiab kev ua haujlwm ntawm qhov chaw.
  • Lub cev thiab ib puag ncig: Qee yam uas tuaj yeem pib lossis ua kom cov hluav taws xob tawm sai dua yog cov pob qij txha busbar tsis zoo, cov xov hlau tsis zoo, kev hloov pauv, kev hloov pauv kub, kev co, av noo, thiab kev ua qias tuaj ntawm cov tshuaj lom neeg. Muaj tej lub sijhawm uas lub tshuab hluav taws xob sab hauv tsev qhia cov tsos mob tab sis qhov ua rau yog lwm qhov. Qhov no yog vim li cas kev daws teeb meem yuav tsum suav nrog tag nrho cov khoom sib dhos, suav nrog kev sib txuas hauv av, thiab tsis yog lub tshuab hluav taws xob xwb.

Qhov kev faib no qhia koj seb puas yuav tsum hu rau tus tsim vaj huam sib luag, tus neeg teeb tsa, lossis tus neeg muag khoom ua ntej.

Yuav Tsum Sim Thiab Nruab Ib Lub Transformer Hauv Tsev Li Cas?

Kev Ntsuas Ib Txwm thiab Hom rau PD thiab Qhov Tseeb

Zoo tshaj plaws los sim ua tej txheej. Kev sim ib txwm muaj xws li kev kuaj xyuas qhov loj thiab cov duab, kev kuaj xyuas qhov tsis kam ntawm winding, qhov sib piv, polarity, qhov tsis kam ntawm rwb thaiv tsev, lub zog-zaus withstand, thiab ntsuas PD thaum qhov kev qhia tshwj xeeb xav tau. Thaum nws los txog rau cov qauv tsim tshiab, qhov loj me tshwj xeeb, thiab OEM vaj huam sib luag sib cuam tshuam, kev sim hom yog qhov tseem ceeb tshaj plaws. IEC 60270 hais tias kev ntsuas ntawm PD yog qhov them uas pom hauv picocoulombs. Thaum koj nyeem cov txiaj ntsig, ceev faj. Lub zog pib, lub zog ploj mus, lub suab nrov tom qab, thiab qhov sib txawv dhau sijhawm yog qhov tseem ceeb, thiab tsis muaj ib tus lej dhau lossis tsis ua tiav uas ua haujlwm rau txhua tus qauv tsim. Thov kom tau daim ntawv qhia uas mus nrog tus qauv thiab qhov ntsuas koj xav yuav.

Cov Kauj Ruam Txhim Kho Uas Tiv Thaiv Cov Khoom Rwb Thaiv Tsev

Ib txoj kev npaj zoo yuav raug khaws cia kom muaj kev nyab xeeb los ntawm kev teeb tsa zoo. Xyuas lub npe, cov cim polarity (P1/P2 ntawm lub thawj thiab S1/S2 ntawm lub thib ob), kev teeb tsa sib dhos, qhov sib nrug, cov ntawv lo rau lub davhlau ya nyob twg, qhov chaw av, thiab lub zog nruj ua ntej tig nws. Xyuas kom tseeb tias cov nplaim resin huv thiab qhuav, thiab xyuas kom tseeb tias cov xov hlau thib ob tsis rub rau ntawm cov davhlau ya nyob twg. Ua ntej tig, luv cov tub ntxhais thib ob uas tsis tau siv. Yog tias koj siv zog ntau dhau rau ntawm lub davhlau ya nyob twg, cov yas nyob ze tuaj yeem tawg, thiab qhov tawg ntawd tuaj yeem dhau los ua qhov chaw PD. Cov neeg ua haujlwm commissioning tuaj yeem zam kev ua yuam kev nrog kev pab los ntawm kev npaj xov hlau uas sau txhua lub tub ntxhais thiab lub voj voog hloov.

Kev Txij Nkawm thiab Kev Saib Xyuas Hauv Kev Pabcuam

Kev saib xyuas uas ua tas li yog qhov yooj yim. Tshawb xyuas txhua lub tshuab hluav taws xob sab hauv tsev rau cov kab nrib pleb, xim tsis zoo, lossis cov cim taug qab. Ntxuav cov hmoov av tawm ntawm cov nplaim rwb thaiv tsev, xyuas kom tseeb tias cov terminals nruj, thiab saib xyuas qhov kub ntawm cov ntsiab lus sib txuas. Sim qhov tsis kam ntawm cov rwb thaiv tsev thaum lub sijhawm hluav taws xob tsis ua haujlwm. Thaum nws los txog rau cov khoom noj tseem ceeb, kev taug qab PD online tuaj yeem qhia qhov sib txawv nce ntxiv ua ntej muaj qhov txhaum tshwm sim. Kev kuaj xyuas yuav tsum tau ua ntau zaus hauv cov chav uas muaj av noo lossis qias neeg dua li hauv cov chaw tswj hwm huab cua. Peb lub 24kV chav tsev lub cev epoxy kaw tag nrho tiv thaiv cov hmoov av thiab dej, tab sis kuv tseem xav tias nws tseem ceeb heev rau kev sau txhua qhov kev tshuaj xyuas kom cov nyeem tom qab muaj qhov pib.

Cov Neeg Yuav Khoom Yuav Tsum Xaiv Lub Transformer Sab Hauv Tsev Rau Switchgear Li Cas?

Piv rau Hom Sab Hauv Tsev, Sab Nraud, thiab Split-Core

Feem ntau, ob hom no tsis muaj kev nyab xeeb dua li PD; lawv txhua tus ua haujlwm los daws qhov teeb meem sib txawv. Lub tshuab hluav taws xob me me, cam khwb cia sab hauv tsev yog ua rau cov vaj huam sib luag uas khaws cia sab hauv, qhov twg qhov txaus ntshai tseem ceeb yog condensation, plua plav, thiab qhov chaw tsawg. Vim yog huab cua, UV lub teeb, kev ua qias tuaj, thiab qhov xau ntawm qhov chaw uas cov chav sab nraum zoov yuav tsum tau daws, lawv xav tau cov kab ntev dua. Split-core CTs tuaj yeem qhib kom haum rau ib puag ncig tus neeg coj hluav taws xob uas twb muaj lawm, uas yog qhov pab tau rau kev kho dua tshiab. Txawm li cas los xij, qhov sib koom ua ke qhib, daim ntawv interface, thiab qhov tseeb yuav tsum tau saib xyuas kom zoo. Tsuav koj xyuas nws qhov kev ua haujlwm dielectric, lub tshuab sab hauv tsev molded feem ntau ua haujlwm zoo tshaj plaws rau cov vaj huam sib luag medium-voltage tshiab.

Chav Kawm Tseeb, Lub nra hnyav, thiab Qhov Loj

Ua koj txoj haujlwm ua ntej. Chav kawm 0.2, 0.2S, lossis 0.5 yog siv los ntawm cov metering cores, thiab 5P thiab 10P nrog qhov tseeb txwv ntawm 5P10 yog siv los ntawm cov cores tiv thaiv. Cov lej no tham txog qhov tseeb ntawm kev ntsuas, tsis yog PD ua haujlwm zoo li cas. Tom ntej no, ntxiv cov 'meter' lossis relay load, qhov tsis kam ntawm cov hlau lead, thiab qhov poob ntawm kev sib cuag. Cov theem thauj khoom txheem los ntawm 2.5 VA txog 30 VA tau muab rau hauv IEC 61869-2. A 1 A theem nrab txiav cov hlau lead poob los ntawm 25 zaug ntau dua li 5 A theem nrab hauv tib lub cable. Thaum kawg, muab cov qauv, qhov rai, thiab cov qhov mounting rau ntawm koj lub txee kom paub tseeb tias lawv haum.

Cov Khoom Siv Tseem Ceeb thiab Cov Lus Qhia Txog Kev Ua Haujlwm Ntau Yam

Thaum nws los txog rau ntau qhov kev tsim qauv winding, qhov tsawg kawg nkaus kom muaj nuj nqis, lub sijhawm ua khoom, thiab kev xaiv ntawm lub hauv paus txhua yam dhau los ua qhov nyuaj dua. Cov hauv paus ua los ntawm cov hlau silicon ua haujlwm zoo rau cov windings kev nyab xeeb uas yuav tsum tau nyob twj ywm ntawm cov hluav taws xob siab. Cov hauv paus uas yog microcrystalline lossis nanocrystalline ua haujlwm zoo rau cov windings ntsuas uas xav tau qhov yuam kev me me ntawm cov hluav taws xob qis. Thaum muaj kev xav tau sib xyaw, feem ntau muaj ob lossis peb lub hauv paus hauv ib lub cev, uas kuj hloov qhov loj me. Muab koj daim duab kos rau hauv txee thiab tus lej ntawm cov hauv paus, chav kawm, cov khoom thauj, thiab cov piv rau txhua qhov winding. Tom qab ntawd peb yuav tham nrog koj txog seb nws puas ua tau, thaum twg cov qauv yuav npaj txhij, thiab koj xav tau ntau npaum li cas los txiav txim. Nws txuag tau qhov kev sim thib ob los daws cov teeb meem no ua ntej thawj cov qauv.

Cov Neeg Yuav Khoom Yuav Tsum Tshawb Xyuas Dab Tsi Ua Ntej Yuav Lub Transformer Sab Hauv Tsev?

Cov Ntaub Ntawv Thov Ua Ntej Koj Yuav Khoom

Ua ntej koj tso ib qho kev txiav txim rau lub tshuab hloov pauv tam sim no sab hauv tsev , xyuas kom tseeb tias koj tau txais pob khoom siv nrog cov khoom hauv qab no: daim ntawv qhia txog cov ntaub ntawv, daim duab kos duab, daim duab qhia txog kev sib txuas lus, cov ntaub ntawv ntawm qhov tseeb thiab qhov hnyav, cov lus qhia txog kev rwb thaiv tsev, daim ntawv qhia txog kev sim ib txwm muaj, cov ntaub ntawv sim hom, cov ntaub ntawv PD, cov ntaub ntawv ntawm cov khoom siv, daim ntawv pov thawj, thiab cov lus qhia txog kev teeb tsa. Ua ntej ua ntau yam ntawm lawv, thov kom pom zoo rau cov duab kos thiab cov qauv kom haum. Feem ntau, tus neeg muag khoom uas tuaj yeem piav qhia nws txoj kev sim PD, qhov hluav taws xob sim, thiab lub voj voog ntsuas muaj cov txheej txheem tswj hwm tom qab tus lej. Cov ntaub ntawv kuj tseem muaj txiaj ntsig tom qab; yog tias ib chav tsev puas tsuaj thaum siv, cov ntaub ntawv batch tuaj yeem pab txiav txim siab seb muaj dab tsi tsis raug.

Cov Yuam Kev Feem Ntau Uas Ua Rau PD Thiab Kev Pheej Hmoo Hauv Lub Neej

Muaj plaub qhov yuam kev uas tshwm sim tas li. Ua ntej, tib neeg xaiv lub tshuab hloov hluav taws xob sab hauv tsev raws li nws qhov sib piv xwb, tsis suav nrog nws qib rwb thaiv tsev, qhov hnyav, lossis qhov loj. Qhov thib ob, lawv nyeem 5P10 lossis 10P10 ua qhov ntsuas PD, tab sis cov lej no tsuas yog qhia tias kev tiv thaiv ua haujlwm zoo npaum li cas. Qhov thib peb, lawv yuav siv ib chav tsev uas haum rau cov bolts tab sis tsis muaj qhov chaw txaus ntawm cov theem lossis ntawm cov theem thiab av. Qhov thib plaub, lawv tau xaiv lub tshuab hloov hluav taws xob sab hauv tsev pheej yig tshaj plaws uas tsis muaj cov ntaub ntawv xeem raug thov. Kuj tseem yuav tsum muaj lus hauv kev tsim qauv txog av noo, plua plav, kev co, kev thauj khoom ntau dhau, thiab kev loj hlob ntawm kev thauj khoom yav tom ntej.

Xi'an Xikai 24kV Sab Hauv Tsev Tam Sim No Transformer ntawm Ib Saib

Xi'an Xikai lub tshuab hloov hluav taws xob sab hauv tsev 24kV yog ib lub tshuab hluav taws xob uas kaw tag nrho ua los ntawm epoxy resin. Nws muaj qhov tseeb heev, muaj peev xwm loj, thiab ua haujlwm tau zoo. Nws ua haujlwm ntawm 50/60 Hz, muaj qhov tam sim no tseem ceeb ntawm 20 A txog 3150 A, thiab muaj qhov tam sim no thib ob ntawm 5 A lossis 1 A. Cov qib ntawm qhov tseeb yog 0.2 thiab 0.5. Daim phiaj xwm yog ua raws li IEC 61869-1 thiab 61869-2 thiab GB 20840.2-2014. Txij li -40 ° C txog +70 ° C, cov ntaub ntawv khoom kuj hais tias nws tuaj yeem tswj tau qhov luv luv ntawm 25 kA rau 3 vib nas this. Tshawb xyuas qib qauv tseeb piv rau daim duab ntawm lub vaj huam sib luag.

Vim li cas OEM Switchgear Builders Ua Haujlwm Nrog Xi'an Xikai

Xi'an Xikai ua xya hom khoom tseem ceeb, xws li switchgear, dry-type transformers, vacuum circuit breakers, thiab instrument transformers. Qhov no txhais tau tias CT drawings thiab panel drawings tuaj yeem saib ua ke. Lub Xeev Grid, petrochemicals, kev thauj mus los ntawm tsheb ciav hlau, thiab cov haujlwm renewable energy txhua yam siv peb cov kev daws teeb meem. Muaj ntau tshaj 15 daim ntawv pov thawj uas tiv thaiv 24kV system, uas tau ua tiav los ntawm Tuam Tshoj National 863 Program. Peb tuaj yeem hloov cov zis dual-ratio thiab me me rau cov rooj plaub uas tsis loj heev. Yog tias koj yuav ib xyoos ib zaug thiab tso cov xaj txhua hli, thov qhia rau peb paub koj xav li cas ob peb lub hlis tom ntej yuav zoo li cas kom peb tuaj yeem npaj peb cov khoom tsim nyob ib puag ncig koj lub txee teem sijhawm thiab muab sijhawm rau peb tus kheej los kuaj cov lus qhia tshiab.

Hoobkas

xaus

Lub tshuab hloov hluav taws xob sab hauv tsev txo qhov kev pheej hmoo ntawm kev tso tawm ib nrab, tab sis nws tsis tuaj yeem tshem nws tus kheej. Tus qauv tsim yog raws li kev tswj hwm qhov tsis muaj dab tsi hauv epoxy casting, lub geometry teb du, thiab kev sib koom ua ke zoo rwb thaiv tsev. Lub Hoobkas PD kev xeem raws li IEC 60270 ntxiv rau hom kev xeem rov qab qhov no. Kev teeb tsa zoo, cov chaw huv si, thiab kev tshuaj xyuas tsis tu ncua tiv thaiv qhov ntawd hauv kev pabcuam, thiab ntau qhov teeb meem PD yog tshwm sim los ntawm cov khoom vaj huam sib luag es tsis yog CT. Chav kawm raug, lub nra hnyav, cov khoom siv tseem ceeb, thiab qhov loj ntawm lub txee txhua yam ua lub luag haujlwm hauv kev xaiv. Cov lej 5P10 thiab 10P10 tsis hais dab tsi txog PD. Yog tias cov neeg yuav khoom saib cov ntaub ntawv xeem thiab cov ntawv nrog rau tus nqi, lawv txo qhov kev pheej hmoo ntawm kev sib koom ua ke thiab kev pabcuam.

FAQ 

1. Lub tshuab hloov hluav taws xob sab hauv tsev puas tuaj yeem tiv thaiv kev tso tawm ib nrab?

Tsis yog. Nws tuaj yeem txo qhov kev pheej hmoo ntawm PD los ntawm kev ua kom paub tseeb tias epoxy casting tsis muaj qhov khoob thiab qhov geometry ntawm thaj chaw du. PD kuj tseem cuam tshuam los ntawm cov pob qij txha busbar, cov terminations, grounding, thiab ib puag ncig, yog li saib tag nrho lub vaj huam sib luag.

2. Puas yog 5P10 thiab 10P10 qhov kev ntsuas tawm ib nrab?

Tsis yog. Cov chav kawm no qhia tau tias lub tshuab hluav taws xob sab hauv tsev ua haujlwm zoo npaum li cas thiab siv rau kev tiv thaiv. Kev ua tau zoo ntawm PD yog sau rau hauv cov ntawv qhia kev xeem, thiab feem ntau yog muab hauv picocoulombs ntawm qee qhov hluav taws xob xeem.

3. Kuv yuav tsum nug tus neeg muag khoom li cas ua ntej kuv yuav khoom?

Koj yuav tsum nug txog daim ntawv qhia txog cov khoom siv, daim duab kos, daim duab qhia txog kev txuas hluav taws xob, cov ntaub ntawv ntawm qhov hnyav thiab qhov tseeb, cov ntawv qhia txog kev sim ua haujlwm niaj hnub thiab hom, cov ntaub ntawv PD, thiab cov lus qhia txog kev teeb tsa. Nug txog kev hloov kho kom haum, kev pom zoo sim, thiab kev xa khoom mus rau cov neeg xa khoom tawm thiab.

4. Kuv yuav ntsuam xyuas tus neeg tsim khoom uas ntseeg tau li cas?

Saib lawv cov txuj ci kev txawj ntse, kev paub dhau los nrog cov txheej txheem zoo xws li ISO 9001, cov cuab yeej kuaj, muaj peev xwm ua haujlwm nrog lub zog hluav taws xob nruab nrab, muaj peev xwm xa tawm, thiab muaj peev xwm pab kho kom haum. Cov lus thov tau txhawb nqa los ntawm cov qauv teeb tsa ua ntej tsim ntau lawm.

Thov kom muaj 24kV Sab Hauv Tsev Transformer Quote los ntawm Xi'an Xikai

Nrhiav ib lub tuam txhab uas tuaj yeem ua lub tshuab hloov pauv tam sim no sab hauv tsev rau koj cov kab switchgear? Xi'an Xikai ua cov epoxy resin cast 24kV units uas tuaj yeem ua kom haum rau koj cov kev xav tau thiab tau txais kev txhawb nqa los ntawm ISO 9001 kev tswj hwm zoo thiab ntau yam thev naus laus zis tshwj xeeb. Koj tuaj yeem xa email rau serina@xaxd-electric.com , amber@xaxd-electric.com , lossis luna@xaxd-electric.com koj qhov voltage, piv, chav kawm raug, load, thiab qauv txee. Ua teb, peb cov engineers muab cov lus qhia txog kev siv tshuab rau koj. Yog xav paub ntxiv, mus saib xaxd-electric.com.

daim ntawv pov

References

1. IEC 61869-2: Cov Khoom Siv Hloov Pauv - Ntu 2: Cov Kev Cai Ntxiv rau Cov Hloov Pauv Tam Sim No, 2012

2. IEC 61869-1: Cov Khoom Siv Hloov Pauv - Ntu 1: Cov Kev Cai Dav Dav, 2007

3. IEC 60270: Cov Txuj Ci Ntsuas Hluav Taws Xob Siab - Kev Ntsuas Ib Feem Ntawm Kev Tso Tawm, 2000

4. IEC 62271-200: Cov Khoom Siv Hluav Taws Xob Siab thiab Cov Khoom Siv Tswj - AC Cov Khoom Siv Hluav Taws Xob thiab Cov Khoom Siv Tswj rau Cov Hluav Taws Xob Ntsuas Siab Tshaj 1 kV thiab Txog Li 52 kV, 2021

5. GB 20840.2: Cov Khoom Siv Hloov Pauv - Ntu 2: Cov Kev Cai Ntxiv rau Cov Hloov Pauv Tam Sim No, 2014

6. IEEE Std C57.13: IEEE Cov Kev Cai Txheem rau Cov Khoom Siv Hloov Pauv, 2016

Xa