khoomPic

Lub txhab nyiaj capacitor hauv 33/11kv substation

1. Kev them nyiaj tsis siv neeg thauj khoom reactive fais fab, txhim kho qhov load fais fab factor;
2. Txo qhov poob ntawm lub network, ua haujlwm tau zoo thiab txuag hluav taws xob;
3. Tswj cov harmonics ntawm lub system lossis tswj cov harmonics raws li tus neeg siv xav tau;
4. Txo cov reactive tam sim no, txuag transformer peev xwm nqi, txhim kho cov zis transformer.
5. Kev tswj hwm qhov tseem ceeb ntawm qhov hluav taws xob, qhov kev tswj hwm qhov hluav taws xob ntawm lub capacitor tuaj yeem siv los txhim kho qhov hluav taws xob dhau tus nqi.
Xa Nug
download
  • Kev xa khoom sai
  • zoo Assurance
  • 24/7 Cov Pabcuam Cov Neeg Siv Khoom

khoom Introduction

Lub Tsev Txhab Nyiaj Capacitor hauv 33/11kV Substation - Kev daws teeb meem kho qhov fais fab kev tshaj lij

khoom Introduction

Thaum koj lub tshuab hluav taws xob ntsib teeb meem kev nplua rau lub zog fais fab thiab teeb meem kev ruaj khov ntawm lub zog, koj xav tau lub txhab nyiaj capacitor txhim khu kev qha hauv 33/11kv substation . Peb cov khoom siv kho lub zog fais fab siab heev muab kev them rov qab tam sim ntawd rau cov tes hauj lwm faib hluav taws xob nruab nrab. Qhov kev sib dhos tseem ceeb ntawm cov capacitor units txuas nrog cov qauv sib txuas lossis sib luag. Nws ua haujlwm tsis muaj teeb meem hauv 11kV thiab 33kV systems los tswj lub zog reactive kom zoo. Koj tau txais kev tsim hluav taws xob reactive ua ntej uas tawm tsam lub zog lagging los ntawm cov khoom thauj inductive xws li transformers thiab motors.

Peb txoj kev daws teeb meem daws koj cov teeb meem hluav taws xob uas nyuaj tshaj plaws. Cov kev nplua rau lub zog qis yuav ploj mus thaum koj ua tiav qhov kev kho kom ze-unity. Cov hluav taws xob poob ntawm cov chaw kawg ntawm feeder tuaj yeem tswj tau los ntawm kev txhawb nqa lub zog hluav taws xob ntawm lub tsheb npav. Cov kev txwv ntawm lub peev xwm ntawm lub kaw lus yooj yim dua thaum cov hluav taws xob tam sim no txo ​​qis tso tawm lub peev xwm KVA muaj nqis. Koj txuag tau ntau ntawm kev txhim kho cov khoom siv thaum txo cov kev poob ntawm kev siv tshuab thoob plaws hauv koj lub network.

Kev Specifications

parameter 11kV Lub Cev 33kV Lub Cev
Qhov hluav taws xob ntsuas hluav taws xob 11kV 33kV
nyob Voltage 12kV 36kV
Basic Insulation Level (BIL) 75kVp 170kVp
Reactive Fais Fab Ntau Yam 1-50 MVAR 5-100 MVAR
Zaus 50 / 60Hz 50 / 60Hz
Kev Txuas Hom Delta/Lub Hnub Qub Delta/Double Star
Kev khiav hauj lwm Kub -40 ° C rau + 55 ° C -40 ° C rau + 55 ° C
Lub sijhawm tso tawm ≤10 feeb rau 50V ≤10 feeb rau 50V
Capacitance kam rau ua -5% txog +10% -5% txog +10%
Dielectric Loss <0.2 W/kVAR <0.2 W/kVAR

Lub ntsiab nta thiab qhov zoo

Kev Siv Tshuab Dielectric Siab Tshaj Plaws : Koj cov khoom siv tau txais txiaj ntsig los ntawm cov yeeb yaj kiab polypropylene zoo. Peb siv cov roj synthetic uas lwj tau kom tsis txhob muaj kev puas tsuaj rau ib feem ntawm cov hluav taws xob. Qhov no ua kom ntseeg tau tias muaj kev ntseeg siab mus sij hawm ntev hauv cov chaw nyob hauv tsev uas xav tau hluav taws xob ntau.

Kev Tswj Xyuas Kev Hloov Pauv Ntse : Cov relays kho qhov fais fab tsis siv neeg saib xyuas koj lub cev tas li. Lawv hloov cov kauj ruam capacitor raws li cov xwm txheej thauj khoom tiag tiag. Koj tswj tau qhov fais fab zoo tshaj plaws yam tsis muaj kev cuam tshuam los ntawm tes.

Kev kam rau siab harmonic : Peb cov qauv tsim tswj tau qhov voltage thiab tam sim no overloads zoo. Koj tau txais 1.1x rated voltage thiab 1.3x rated current muaj peev xwm. Qhov no tiv thaiv kev sib raug zoo hauv network thiab kev hloov pauv transients.

Kev Sib Koom Tes Kev Nyab Xeeb : Cov resistors tso tawm uas ua rau hauv yuav tiv thaiv koj cov neeg ua haujlwm. Cov hluav taws xob seem poob qis mus rau qib nyab xeeb hauv lub sijhawm uas xav tau. Koj ua raws li txhua txoj cai kev nyab xeeb yam tsis tas siv neeg.

Kev siv tswv yim

Chaw Muab Fais Fab Thawj Zaug : Cov neeg ua haujlwm siv hluav taws xob teeb tsa peb cov kab ke ntawm cov busbars tseem ceeb. Koj tswj tau qhov hluav taws xob ntawm lub grid thaum lub sijhawm xav tau hluav taws xob ntau tshaj plaws. Lub capacitor bank hauv 33/11kv substation tiv thaiv qhov hluav taws xob poob qis los ntawm kev txhaj tshuaj fais fab zoo.

Cov Chaw Lag Luam Hnyav : Cov chaw ua hlau, cov chaw ua cement, thiab cov chaw tsim khoom tau txais txiaj ntsig zoo heev. Koj kho qhov fais fab txawm tias muaj cov khoom hnyav xws li cov cub tawg arc thiab cov cav loj. Cov reactors detuned series tiv thaiv cov teeb meem harmonic resonance.

Kev Sib Koom Tes Zog Tshiab : Cov chaw ua liaj ua teb cua thiab cov chaw teeb tsa hnub ci xav tau kev tswj hwm lub zog reactive kom meej. Peb cov khoom siv pab koj ua raws li cov cai ntawm lub grid yam tsis muaj teeb meem. Koj tswj tau qhov sib koom ua ke ntawm lub zog ntawm cov chaw sib txuas txawm tias muaj kev hloov pauv ntawm tiam neeg los xij.

Yuav ua li cas Nws Tej hauj lwm

Koj lub cev ua haujlwm los ntawm cov ntsiab cai tswj hwm lub zog reactive zoo heev. Cov chav capacitor tsim cov zog reactive ua ntej los cuam tshuam lub zog lagging los ntawm cov khoom thauj inductive. Cov maub los ntse saib xyuas lub zog fais fab tas li los ntawm cov transformers tam sim no thiab voltage.

Thaum koj lub nra hnyav nce ntxiv, cov kauj ruam capacitor ntxiv yuav ua haujlwm tau yam tsis tas siv zog. Thaum lub sijhawm thauj khoom me me, cov kauj ruam txiav tawm kom tiv thaiv kev them nyiaj ntau dhau. Cov txheej txheem tiv thaiv saib xyuas cov teeb meem sab hauv thiab cov xwm txheej tsis sib npaug. Koj tau txais kev ua haujlwm txhim khu kev qha nrog kev kuaj pom qhov txhaum tag nrho.

Kev Tsim Khoom Zoo

Xi'an Xikai Medium thiab Low Voltage Electric Co., Ltd. coj ntau xyoo ntawm kev txawj ntse rau txhua chav tsev. Peb txoj kev tsim khoom ua raws li IEC 60871 thiab IEEE cov qauv nruj. Txhua qhov khoom raug kuaj xyuas ua ntej sib dhos.

Peb muaj daim ntawv pov thawj ISO9001 kev tswj xyuas zoo nrog rau daim ntawv pov thawj ib puag ncig thiab kev nyab xeeb. Peb lub peev xwm tsim khoom npog 0.4kV txog 40.5kV voltage ntau yam nrog cov tam sim no txog li 4000A. Koj tau txais cov khoom kuaj rau kev ua haujlwm txog li 4000m qhov siab.

Kev tswj xyuas zoo suav nrog kev ntsuas tan delta thiab kev sim siab voltage. Kev txheeb xyuas kev ruaj khov ntawm kev sib khi ua kom ntseeg tau ntev. Kev kuaj xyuas capacitance ua rau lub kaw lus sib npaug thoob plaws kev ua haujlwm.

Yog vim li cas thiaj xaiv peb

Cov Ntaub Ntawv Ua Tau Zoo : Peb cov khoom siv rau cov chaw muab kev pabcuam thiab kev lag luam thoob plaws ntau yam kev siv. Koj tau txais txiaj ntsig los ntawm cov qauv tsim uas tau ua pov thawj hauv daim teb thiab cov kev pab cuam txhim kho tas mus li.

Kev daws teeb meem tag nrho : Peb muab cov kev daws teeb meem sib xyaw ua ke dhau ntawm cov khoom ib leeg. Koj tau txais kev txhawb nqa tag nrho los ntawm kev tsim qauv mus txog kev ua haujlwm thiab kev saib xyuas.

Kev Paub Txog Kev Siv Tshuab : Peb pab neeg ua haujlwm engineering nkag siab txog cov kev xav tau ntawm lub zog fais fab uas nyuaj heev. Koj tau txais cov kev daws teeb meem uas haum rau koj tus kheej uas daws tau cov teeb meem tshwj xeeb hauv kev ua haujlwm.

Kev Txhawb Nqa Txhim Khu Kev : Kev them nqi lav tag nrho thiab kev pabcuam kev txawj ntse teb sai sai ua kom muaj sijhawm tsawg kawg nkaus. Peb lub network kev pabcuam muab kev pabcuam sai sai thaum xav tau.

FAQ

Q: Kuv yuav xaiv li cas ntawm kev teeb tsa ruaj khov thiab kev teeb tsa tsis siv neeg?

A: Cov txhab nyiaj ruaj khov haum rau cov khoom siv tas li xws li kev them nyiaj rau transformer. Cov txheej txheem tsis siv neeg tswj cov khoom sib txawv tau zoo. Koj tiv thaiv kev them nyiaj ntau dhau thaum lub sijhawm tsis yog lub sijhawm siab tshaj plaws nrog kev ua haujlwm hloov pauv.

Q: Yuav tsum muaj kev tiv thaiv dab tsi rau kev ua haujlwm kom muaj kev nyab xeeb?

A: Kev tiv thaiv hluav taws xob tsis sib npaug ntawm qhov nruab nrab yuav ntes tau qhov tsis ua haujlwm ntawm cov khoom sab hauv thaum ntxov. Kev tiv thaiv tam sim no tsis sib npaug yuav tiv thaiv kev tawg ntawm lub tank loj heev. Koj xav tau ob qho tib si rau kev tiv thaiv kev nyab xeeb tag nrho.

Q: Cov no puas ua haujlwm tau hauv cov chaw muaj kev sib haum xeeb?

A: Cov chav ntsuas txheem xav tau cov reactors detuned hauv cov chaw harmonic. Cov no hloov qhov zaus resonance tawm ntawm cov harmonics tseem ceeb. Koj tiv thaiv capacitor overheating thiab ua tsis tiav ua ntej.

Q: Kuv yuav tsum ua raws li cov sijhawm txij nkawm twg?

A: Kev ntsuas capacitance txhua xyoo pom kev ua haujlwm fuse thaum ntxov. Kev kuaj xyuas torque ntawm kev sib txuas ntawm Busbar tiv thaiv kev kub dhau. Kev ntxuav cov insulator tsis tu ncua ua rau kev ua haujlwm zoo. Lub txhab nyiaj capacitor hauv 33/11kv substation xav tau kev saib xyuas tsawg kawg nkaus tab sis tas li.

Q: Vim li cas cov circuit breakers thiaj li tawg thaum lub sijhawm energizing?

A: Cov hluav taws xob inrush siab ua rau muaj kev cuam tshuam nrog cov breakers txheem. Siv cov breakers Class C2 uas tsim los rau kev hloov capacitor. Cov reactors txwv tam sim no kuj txo cov inrush zoo.

Hu Rau Peb

Npaj txhij los txhim kho koj lub zog fais fab kom zoo dua thiab txo cov nqi khiav lag luam? Peb pab neeg txawj ntse npaj txhij los tsim cov kev daws teeb meem zoo tshaj plaws rau koj cov kev xav tau tshwj xeeb.

Email : serina@xaxd-electric.com

Tiv tauj peb hnub no los tham txog koj cov kev xav tau kho qhov fais fab. Peb muab cov lus qhia ntxaws ntxaws, tus nqi sib tw, thiab kev txhawb nqa thoob plaws hauv koj lub voj voog ntawm koj qhov project.

Xa