400V Metallurgical Tus Kheej Kho Capacitor
2. Kev Sib Txawv ntawm Capacitance -5% ~ + 10%.
3.Max Tam Sim No 2.5 × Hauv.
Nruab nrog cov resistors tso tawm 4. Kev sib xyaw nrog cov khoom siv tiv thaiv hluav taws xob ywj pheej.
5. Kev ua tau zoo dua qub thiab lub neej ua haujlwm ntev.
6. Qhov tsis tshua muaj kev poob qis, tsim hom qhuav nrog kev tsim kho tsis muaj qhov xau.
7. Nruab nrog cov resistors tawm.
- Kev xa khoom sai
- zoo Assurance
- 24/7 Cov Pabcuam Cov Neeg Siv Khoom
khoom Introduction
400V Metallurgical Tus Kheej Kho Capacitor
khoom Introduction
Lub Capacitor 400V Metallurgical Self-Healing Capacitor sawv cev rau kev tshawb pom tshiab hauv kev siv tshuab kho qhov fais fab. Cov khoom siv hluav taws xob siab heev no siv cov txheej txheem nqus tsev tshwj xeeb los tsim cov kev daws teeb meem fais fab txhim khu kev qha thiab muaj kev nyab xeeb rau kev siv hauv kev lag luam. Koj yuav pom tias lub capacitor no muaj kev ua tau zoo dua piv rau cov chav roj uas muaj roj ib txwm muaj. Peb lub capacitor muaj cov peev xwm kho tus kheej siab heev uas tshem tawm cov teeb meem tam sim ntawd thiab rov ua haujlwm tau hauv microseconds. Kev tsim tshiab no tshem tawm cov kev ua tsis tiav loj heev thaum muab kev them rov qab fais fab ruaj khov hauv cov chaw muaj hluav taws xob nyuaj.
Ua rau cov chaw ua haujlwm nyuaj, lub capacitor no zoo heev rau cov ntawv thov uas xav tau kev kho qhov fais fab tas li. Koj tau txais cov yam ntxwv kev nyab xeeb zoo dua, lub neej ua haujlwm ntev dua, thiab kev ua haujlwm tsis tas yuav saib xyuas. Kev tsim kho hom qhuav tshem tawm cov kev pheej hmoo xau thaum muab kev ua haujlwm thermal zoo heev.
Kev Specifications
| parameter | specification |
|---|---|
| nyob Voltage | 400V AC |
| Zaus | 50 / 60Hz |
| Capacitance kam rau ua | -5% txog +10% |
| Siab Tshaj Plaws Tam Sim No | 2.5 × Qhov Tam Sim No Ntsuas |
| dissipation Factor | ≤0.2W/kvar ntawm 50Hz |
| Kev khiav hauj lwm Kub | -25 ° C rau + 70 ° C |
| Kev Pab Lub Neej | > 100,000 teev |
| Cov khoom siv Dielectric | Zaj duab xis Polypropylene metallized |
| Kev Nyab Xeeb Kev Nyab Xeeb | Kev Tshem Tawm Overpressure |
| Kev Ua Raws Cai | IEC 60831-1/2, EN 60252-1 |
Lub ntsiab nta thiab qhov zoo
Kev Siv Tshuab Kho Tus Kheej Siab Tshaj Plaws
Peb cov txheej txheem tso cov hlau ua los ntawm lub tshuab nqus tsev tsim cov txheej Zinc-Aluminium alloy uas tuab heev. Thaum muaj hluav taws xob ntau dhau, lub zog arc yuav ua rau lub electrode nyob ib puag ncig cov qhov tsis zoo tam sim ntawd. Qhov no yuav tshem tawm cov qhov tsis zoo thiab rov ua haujlwm li qub.
Txhim khu kev ruaj ntseg tsim
Lub cuab yeej txiav tawm qhov siab dhau uas sib xyaw ua ke muab kev tiv thaiv tshuab. Yog tias qhov siab sab hauv nce siab vim yog qhov xwm txheej tas sij hawm, qhov kev nyab xeeb no yuav txiav lub voj voog. Koj zam kev tawg thiab hluav taws kub.
Superior Kev Tsim Kho
Tus qauv tsim qhuav tshem tawm cov teeb meem ib puag ncig uas cuam tshuam nrog cov chav tsev uas muaj roj. Kev tsim kho uas muaj cov roj resin ua rau muaj kev tiv thaiv dej noo zoo heev. Lub geometry cylindrical muab kev faib tawm cua sov zoo dua rau kev teeb tsa ntau qhov chaw.
Kev Pabcuam Lub Neej Ntxiv
Cov khoom sib txuas zoo hauv cov hlau ua pa tawm huv si yam tsis tawm cov pa roj carbon uas ua rau muaj hluav taws xob. Qhov no ua rau lub neej ua haujlwm ntev dua 100,000 teev nyob rau hauv cov xwm txheej zoo. Koj txaus siab rau cov nqi kho dua tshiab tsawg dua thiab kev ntseeg siab ntawm lub kaw lus zoo dua.
Kev siv tswv yim
Cov Txheej Txheem Kho Qhov Fais Fab
Cov chaw ua haujlwm hauv kev lag luam siv peb cov capacitors los txhim kho qhov ntsuas fais fab thiab tshem tawm cov kev nplua rau kev siv hluav taws xob. Cov chaw tsim khoom, cov chaw khaws ntaub ntawv, thiab cov tsev lag luam ua tiav kev txuag hluav taws xob ntau.
Cov Ntawv Thov Pib Tsav Tsheb
Cov cav AC tau txais txiaj ntsig los ntawm kev pib ua haujlwm zoo dua thiab txo cov dej ntws nkag. Peb cov capacitors muab kev txhawb nqa ruaj khov rau cov khoom thauj sib txawv thiab kev ua haujlwm pib-nres ntau zaus.
Kev daws teeb meem kev lag luam hlau
Cov chaw ua hlau, cov chaw ua txhuas, thiab cov chaw ua hlau vam khom peb cov capacitors rau kev them rov qab fais fab tas li. Tus qauv tsim muaj zog tswj tau cov chaw ua haujlwm hnyav nrog kev hloov pauv kub heev.
Ib puag ncig nplua nuj harmonic
Thaum ua ke nrog cov reactors detuning, cov capacitors no tswj tau qhov kev cuam tshuam harmonic hauv cov chaw lag luam niaj hnub nrog cov tsav tsheb zaus sib txawv thiab cov khoom siv hluav taws xob.
Yuav ua li cas Nws Tej hauj lwm
Lub 400V Metallurgical Self-Healing Capacitor ua haujlwm los ntawm kev siv tshuab metallized film siab heev. Cov polypropylene dielectric film muaj cov electrodes zinc-aluminum uas tso rau hauv lub tshuab nqus tsev uas tsim cov khoom capacitive.
Thaum lub sijhawm ua haujlwm ib txwm, lub capacitor khaws cia thiab tso tawm lub zog reactive los txhim kho lub zog fais fab. Thaum dielectric tawg, lub tshuab kho tus kheej ua haujlwm tam sim ntawd. Lub zog ua txhaum ua rau cov hlau txheej nyob ib puag ncig qhov tawg, tsim ib cheeb tsam rwb thaiv tsev.
Lub capacitor tseem ua haujlwm nrog lub peev xwm txo qis me ntsis tab sis tseem ua haujlwm tau zoo. Cov txheej txheem no tuaj yeem rov ua dua ntau txhiab zaus thoob plaws lub neej ua haujlwm. Lub kaw lus kev nyab xeeb overpressure saib xyuas cov xwm txheej sab hauv thiab txiav lub tshuab yog tias lub zog roj siab tshaj qhov txwv kev nyab xeeb.
Kev Tsim Khoom Zoo
Ntawm Xi'an Xidian Medium thiab Low Voltage Electric Co., Ltd., peb tswj hwm cov qauv zoo thoob plaws hauv kev tsim khoom. Peb cov txheej txheem tsim khoom suav nrog cov txheej txheem kuaj xyuas kom meej rau kev tiv thaiv hluav taws xob, kev txheeb xyuas tus kheej kho, thiab kev lees paub lub tshuab kev nyab xeeb.
Peb ua qhov kev ntsuam xyuas hluav taws xob ntawm qhov kawg ntawm 2.15 npaug ntawm qhov ntsuas hluav taws xob. Kev ntsuam xyuas rwb thaiv tsev siv ntau dua 3000V AC ntawm cov qhov kawg thiab lub thawv. Kev ntsuam xyuas kev tawg ua ntej txheeb xyuas qhov kev ua tau zoo ntawm tus kheej nrog tsawg dua 1% kev poob capacitance.
Peb qhov kev sim ua kom muaj zog siv tau 1.25 npaug ntawm qhov kub siab tshaj plaws rau 2,000 teev. Qhov no ua piv txwv txog kev puas tsuaj ntawm lub neej thiab xyuas kom meej tias zinc-aluminum alloy ruaj khov.
Yog vim li cas thiaj xaiv peb
Kev paub txog kev lag luam pov thawj
Peb muaj ntau tshaj 100 yam khoom sib txawv thoob plaws 34 series, thiab peb nkag siab txog ntau yam kev xav tau ntawm kev lag luam. Peb cov kev daws teeb meem pab cov neeg siv khoom txij li 0.4kV txog 40.5kV nrog cov hluav taws xob txog li 4000A.
Cov Ntawv Pov Thawj Zoo
Peb tswj hwm ISO9001 kev tswj hwm zoo, ISO14001 kev tswj hwm ib puag ncig, thiab OHSAS18001 kev nyab xeeb. Peb cov khoom lag luam ua tau raws li cov qauv hauv tebchaws thiab thoob ntiaj teb tas li.
Comprehensive Product Range
Tsis tas li ntawm cov capacitors, peb muab cov kev daws teeb meem faib hluav taws xob tag nrho suav nrog switchgear, transformers, thiab circuit breakers. Koj tau txais txiaj ntsig los ntawm kev tsim qauv sib xyaw ua ke thiab kev lav phib xaub ib qho chaw.
Kev tsim kho tshiab
Ua ib tug neeg koom nrog hauv 863 lub teb chaws txoj haujlwm, peb nqis peev ntau rau kev tshawb fawb thiab kev txhim kho. Peb pab neeg engineering txuas ntxiv qhia txog cov thev naus laus zis tshiab thiab cov ntaub ntawv los txhim kho kev ua haujlwm ntawm cov khoom.
FAQ
Q: Tus txheej txheem kho tus kheej siv sijhawm ntev npaum li cas?
A: Lub tshuab kho nws tus kheej ua haujlwm hauv microseconds ntawm qhov xwm txheej tawg. Cov txheej hlau ua pa tam sim ntawd, cais qhov txhaum thiab rov ua haujlwm li qub.
Q: Kuv puas siv tau lub capacitor no hauv cov chaw muaj kev sib haum xeeb siab?
A: Rau cov ntawv thov nplua nuj harmonic, txuas lub capacitor nrog cov reactors tiv thaiv resonance. Xav txog qhov ntsuas hluav taws xob siab dua (440V lossis 525V) los tswj qhov hluav taws xob nce ntxiv los ntawm cov ntsiab lus harmonic.
Q: Kuv yuav paub li cas thaum lub capacitor xav tau hloov?
A: Saib xyuas cov qib capacitance tsis tu ncua. Kev txo qis ntawm 5-10% ntawm tus nqi qub feem ntau qhia tias yuav luag tas lub neej. Lub overpressure disconnector yuav ua haujlwm rau kev tiv thaiv kev nyab xeeb.
Q: Yuav tsum muaj kev saib xyuas dab tsi?
A: Cov no yog cov khoom siv uas tsis tas yuav saib xyuas. Ua kev tshuaj xyuas thiab ntsuas qhov muaj peev xwm. Xyuas kom qhov kub thiab txias nyob hauv qhov txwv uas tau teev tseg rau lub neej ua haujlwm zoo tshaj plaws.
Hu Rau Peb
Npaj txhij los txhim kho koj lub zog kho qhov system? Peb pab neeg txawj ntse npaj txhij los pab koj xaiv lub 400V Metallurgical Self-Healing Capacitor uas haum rau koj daim ntawv thov tshwj xeeb.
Tiv tauj peb pab neeg muag khoom kom paub meej txog cov lus qhia, tus nqi, thiab cov ntaub ntawv xa khoom. Peb muab kev txhawb nqa kev txawj ntse txij li kev sab laj thawj zaug mus txog kev teeb tsa thiab kev ua haujlwm.
Email: serina@xaxd-electric.com
Cia peb pab koj ua tiav qhov zoo dua ntawm lub zog hluav taws xob, txo cov nqi zog, thiab txhim kho kev ntseeg siab ntawm lub kaw lus nrog peb cov kev daws teeb meem capacitor siab heev.
Xa Nug