khoomPic

Cov Capacitor Shunt Tsawg Voltage-square

1. Qhov Voltage (Ue): 100v ~ 1000v.
2. Kev teeb tsa sab hauv tsev.
3. Cov ntaub ntawv siv Galvanized steel sheet.
4. Tso zis ntau yam 10 ~ 100kvar.
5. Zaus 50/60Hz.
6.Connection configuration D, Y, YN, III.
7. Terminal Block: M6, M8, M10 (Raws li lub zog capacitor).
8. Poob tanδ <0.001 (20 ° C 50Hz).
9. Kub -25 ° C ~ 50 ° C.
10. Qhov Siab Tshaj Plaws 2000m.
11. Lub capacitor (mus rau phab ntsa) suab ≥50mm.
12. Kev Sib Txawv ntawm Capacitance -5% ~ + 10%.
Xa Nug
download
  • Kev xa khoom sai
  • zoo Assurance
  • 24/7 Cov Pabcuam Cov Neeg Siv Khoom

khoom Introduction

Cov Capacitor Shunt Low Voltage-Square - Kev daws teeb meem zoo ntawm lub zog fais fab

khoom Introduction

Peb Lub Capacitor Shunt Low Voltage-square sawv cev rau qhov siab tshaj plaws ntawm cov thev naus laus zis niaj hnub no rau cov kab ke hluav taws xob ua haujlwm hauv qab 1000V. Lub cuab yeej kho qhov fais fab square-form tshiab no daws cov teeb meem tseem ceeb hauv kev lag luam suav nrog kev nplua rau cov khoom siv hluav taws xob tsis zoo, qhov tsis ruaj khov ntawm voltage, thiab cov nqi zog ntau dhau. Tsis zoo li cov qauv cylindrical ib txwm muaj, peb Lub Capacitor Shunt Low Voltage-square ua kom qhov chaw ua haujlwm tau zoo tshaj plaws hauv kev teeb tsa me me thaum xa cov kev ua tau zoo thiab kev ntseeg siab. Tsim los ntawm cov thev naus laus zis polypropylene zaj duab xis thiab cov peev xwm kho tus kheej, cov kev daws teeb meem no muab rau koj qhov chaw nrog kev tswj hwm lub zog zoo tshaj plaws. (101 lo lus)

Ua rau kev siv hauv kev lag luam thiab kev lag luam uas nyuaj heev, lub capacitor no muaj cov yam ntxwv ruaj khov thiab kev nyab xeeb zoo heev. Koj lub tshuab hluav taws xob yuav tau txais txiaj ntsig los ntawm kev txhim kho lub zog fais fab, txo cov kev nplua rau lub zog reactive, thiab txhim kho kev ua haujlwm zoo.

Kev Specifications

parameter specification
Rated voltage (Ue) 100V-1000V
installation hom Nyob sab hauv tsev
Case Cov Khoom Galvanized Steel Sheet
Fais fab tso zis ntau yam 10 - 100 kVar
Zaus 50 / 60 Hz
Kev sib txuas Configuration D, Y, YN, III
Davhlau ya nyob twg thaiv M6, M8, M10 (Nyob ntawm lub zog)
Dissipation Factor (Tan δ) <0.001 (20 ° C, 50Hz)
Kev khiav hauj lwm Kub -25 ° C rau + 50 ° C
Qhov Siab Tshaj Plaws 2000m
Yam tsawg kawg nkaus ntawm phab ntsa ≥50mm
Capacitance kam rau ua -5% txog +10%

Lub ntsiab nta thiab qhov zoo

Tsim Kom Zoo Rau Qhov Chaw : Lub duab plaub fab tshem tawm qhov chaw pov tseg uas feem ntau siv rau hauv cov cylindrical. Koj cov vaj huam sib luag tswj hwm ua tiav qhov ceev kVar siab dua nrog kev ua kom cua sov zoo dua.

Kev Kho Tus Kheej : Cov zaj duab xis polypropylene metallized siab heev yuav cais cov teeb meem me me. Qhov no ua kom ntseeg tau tias kev ua haujlwm tas mus li thiab ntev lub neej kev pabcuam.

Cov yam ntxwv kev nyab xeeb zoo tshaj plaws : Lub cuab yeej txiav tawm overpressure muab kev cais tawm ntawm lub voj voog tsis siv neeg. Koj lub tsev tseem muaj kev tiv thaiv los ntawm kev puas tsuaj uas yuav tshwm sim.

Kev Ua Raws Li Ib Puag Ncig : Kev tsim kho hom qhuav tshem tawm cov kev pheej hmoo ntawm cov roj xau. Qhov no ua rau peb lub Low Voltage Shunt Capacitor-square zoo tagnrho rau cov chaw rhiab heev.

Kev Kho Qhov Fais Fab Kom Tseeb : Kev kam rau siab ntawm lub peev xwm ua kom muaj kev them rov qab fais fab raws li qhov tseeb. Koj cov nqi zog txo qis thaum lub zog ua haujlwm zoo dua.

Kev siv tswv yim

Kev Tsim Khoom Hauv Kev Lag Luam : Zoo meej rau cov chaw tsim khoom uas muaj cov cav induction hnyav, cov khoom siv vuam, thiab cov tsav hloov pauv zaus. Tus qauv tsim me me haum rau hauv cov vaj huam sib luag APFC uas twb muaj lawm.

Cov Tsev Lag Luam : Zoo tagnrho rau cov khw muag khoom, tsev kho mob, thiab cov chaw ua haujlwm uas xav tau lub zog hluav taws xob ruaj khov. Cov kab ke HVAC tau txais txiaj ntsig los ntawm kev ruaj khov ntawm lub zog hluav taws xob thiab txo qis kev siv hluav taws xob.

Cov Chaw Khaws Cov Ntaub Ntawv : Tseem ceeb heev rau kev tswj hwm lub zog zoo hauv cov chaw server. Tus qauv tsim plaub fab ua kom zoo dua qhov chaw siv rack thaum ua kom ntseeg tau tias kev ua haujlwm zoo.

Cov Txheej Txheem Zog Rov Ua Dua Tshiab : Qhov tseem ceeb hauv kev teeb tsa lub hnub ci thiab cua rau kev ua raws li lub grid thiab kev tswj hwm lub zog reactive.

Yuav ua li cas Nws Tej hauj lwm

Koj lub Low Voltage Shunt Capacitor-square txuas nrog koj lub zog hluav taws xob. Nws muab lub zog reactive hauv zos, txo qhov sib txawv ntawm voltage thiab tam sim no. Qhov no txhim kho koj lub zog los ntawm cov nqi ib txwm muaj ntawm 0.7-0.8 mus rau qib zoo tshaj plaws saum 0.95.

Cov zaj duab xis polypropylene uas ua los ntawm cov hlau khaws lub zog hluav taws xob thaum lub sijhawm muaj hluav taws xob ntau thiab tso tawm thaum lub sijhawm xav tau. Qhov kev sib pauv tas mus li no ua rau lub zog hluav taws xob ruaj khov thiab txo qhov kev ntxhov siab ntawm cov transformers thiab switchgear.

Thaum koj lub tshuab nqus hluav taws xob (reactive power), lub capacitor teb tam sim ntawd. Qhov no tshem tawm qhov xav tau hluav taws xob los ntawm cov chaw muab hluav taws xob, txo koj cov nqi hluav taws xob thiab txhim kho kev ua haujlwm ntawm lub tshuab tag nrho.

Kev Tsim Khoom Zoo

Ntawm Xi'an Xidian Medium thiab Low Voltage Electric Co., Ltd., peb tswj hwm cov qauv zoo nruj thoob plaws hauv kev tsim khoom. Peb cov txheej txheem tsim khoom tau ntawv pov thawj ISO9001 ua kom cov khoom zoo thiab kev ntseeg siab tas mus li.

Txhua lub capacitor raug kuaj xyuas zoo heev suav nrog kev txheeb xyuas lub zog dielectric, kev ntsuas capacitance, thiab kev ntsuas thermal stability. Cov txheej txheem tsim khoom siab heev lav qhov ua tau zoo tshaj plaws hauv cov chaw ua haujlwm nyuaj.

Peb pab neeg ua haujlwm engineering uas muaj kev paub dhau los yeej ib txwm txhim kho cov txheej txheem tsim thiab tsim khoom. Qhov kev cog lus rau qhov zoo tshaj plaws no ua kom koj tau txais cov khoom uas tshaj cov qauv kev lag luam.

Yog vim li cas thiaj xaiv peb

Cov Ntaub Ntawv Ua Tau Zoo : Ntau tshaj kaum xyoo ntawm kev paub hauv kev tsim khoom siv hluav taws xob nruab nrab thiab qis. Peb cov khoom pabcuam cov neeg siv khoom thoob plaws ntau yam lag luam thoob ntiaj teb.

Cov Khoom Siv Muaj Peev Xwm : Txij li 0.4kV txog 40.5kV cov kab ke nrog cov ntsuas tam sim no txog li 4000A. Peb muab cov kev daws teeb meem faib hluav taws xob tiav rau koj cov kev xav tau tshwj xeeb.

Kev Paub Txog Kev Txawj Ntse : Peb pab neeg ua haujlwm engineering muab cov kev daws teeb meem thiab kev txhawb nqa kev txawj ntse. Koj tau txais kev qhia los ntawm cov kws tshaj lij thoob plaws hauv kev npaj thiab kev siv project.

Kev Ruaj Ntseg Zoo : Daim ntawv pov thawj peb zaug (ISO9001, ISO14001, OHSAS18001) qhia txog peb txoj kev cog lus rau qhov zoo, lub luag haujlwm ib puag ncig, thiab kev nyab xeeb.

FAQ

Q: Lub neej xav tau ntawm koj lub Low Voltage Shunt Capacitor-square yog dab tsi?

A: Yog tias koj teeb tsa thiab saib xyuas kom zoo, koj yuav siv tau 15-20 xyoo. Cov thev naus laus zis kho tau tus kheej no yuav ua rau lub neej ua haujlwm ntev dua piv rau cov capacitors ib txwm muaj.

Q: Cov capacitors no puas tuaj yeem tswj tau qhov kev cuam tshuam harmonic?

A: Yog, thaum ua ke nrog cov reactors detuned tsim nyog, peb cov capacitors lim cov harmonics zoo thaum muab kev kho qhov fais fab.

Q: Yuav tsum muaj kev saib xyuas dab tsi?

A: Yuav tsum tau saib xyuas tsawg kawg nkaus. Kev tshuaj xyuas txhua xyoo thiab kev sim lub peev xwm ua haujlwm tsis tu ncua ua kom muaj kev ua haujlwm zoo tshaj plaws.

Q: Kuv yuav ua li cas thiaj txiav txim tau qhov ntsuas kVar kom raug rau kuv daim ntawv thov?

A: Peb pab neeg ua haujlwm muab kev tshuaj xyuas qhov hnyav thiab kev xam qhov loj. Tiv tauj peb nrog koj cov lus qhia hluav taws xob kom tau txais cov lus qhia tshwj xeeb.

Hu Rau Peb

Npaj txhij los txhim kho koj lub zog fais fab zoo thiab txo cov nqi zog? Peb cov kws tshaj lij kev tshaj lij nyob ntawm no los pab koj xaiv qhov kev daws teeb meem Low Voltage Shunt Capacitor-square zoo tshaj plaws rau koj daim ntawv thov.

Yog xav tau cov lus qhia txog kev siv tshuab, cov lus hais, thiab kev sab laj nrog kws tshaj lij, hu rau peb hnub no ntawm serina@xaxd-electric.com.

Cia peb pab koj ua tiav qhov kev kho qhov fais fab zoo tshaj plaws thiab txhim kho kev ua haujlwm ntawm lub cev nrog peb cov thev naus laus zis capacitor uas tau ua pov thawj.

Xa