pūnga tātari matua
2. Auautanga: 50/60Hz.
3. Whakahaere: i roto, i waho rānei.
4. Pāmahana ā-taiao: -40°C ~ +45°C_x000b_(Ka taea e te papa tio te tutuki ki te -45C).
5. Te kawenga hau: kaua e neke atu i te 35m/s.
6. Teitei: kaua e neke atu i te 2000m.
7. Te matotoru o te hukapapa: kaua e neke atu i te 10mm.
8. Kaha rū whenua: 8.
9. Taumata parahanga: III, IV rānei.
- Tukunga Tere
- Tātari kounga
- 24/7 Ratonga Kaihoko
Kupu Whakataki hua
Pūnga Tātari Matua - Otinga Hikohiko Mana Ngaio
Kupu Whakataki hua
Ina hiahiatia he pumau me te pono mō tō pūnaha tuku hiko, ka tukuna e tā mātou pūnga tātari matua ngaio he mahi tino pai. Kei te ngākau o ngā pūnaha whakawhiti hiko tēnei wāhanga rokiroki pūngao nui, e huri ana i te ngaohiko DC pupuhi hei hiko maeneene, pumau mō ō taputapu hiko tairongo. Ahakoa kei te hoahoa koe i ngā pūnaha aunoatanga ahumahi, i ngā taputapu ororongo mahi-teitei rānei, ka whakarite tā mātou pūnga tātari matua i te tuku ngaohiko ōrite me ngā āheinga tātari pai rawa atu.
Kei roto i ā mātou pūnga iahiko he hangarau hiko matatau me ngā āhuatanga ESR iti. He pai rawa te whakahaere i te au ripple me te pumau wera mō ngā tono uaua.
| tawhā | Whakapūtātanga |
|---|---|
| Ngaohiko Whakatauria | 10kV |
| auautanga | 50 / 60Hz |
| Te taiao mahi | Kai roto / waho |
| Awhe Temperature | -40°C ki te +45°C (-45°C mō ngā āhuatanga hukapapa) |
| Uta Hau | Teitei rawa 35m/s |
| Altitude | Ki te 2000m |
| Hukapapa Matotoru | Max 10mm |
| Kaha o te Ru | taumata 8 |
| Taumata Parahanga | III ranei IV |
| Awhe te puritanga | 100µF ki te 10,000µF |
| ESR | <0.1Ω i te 100kHz |
| Ripple Naianei | Tae atu ki te 20A RMS |
Nga waahanga matua me nga painga
Te Kaha Rokiroki Pūngao Tino Pai
Ka roa te pupuri a ā mātou pūnga hiko i te wā e motu ana te hiko. Mā ngā uara pūnga hiko teitei ka mau tonu te mahi a ō pūnaha ahakoa ngā piki me ngā heke o te ngaohiko.
Hoahoa ESR iti
Mā te whakaiti i te ātete raupapa ōrite ka whakaiti i te ngaronga hiko me te wera o roto. Ka hua ake tēnei i te pai ake o te mahi me te roa ake o te ora mahi mō ō pūnaha hiko.
Te Whakahaere i te Au Ripple Whakapai Ake
I hangaia kia tū atu i ngā iahiko AC teitei, me te kore e wera rawa. Nā tēnei āhuatanga i pai ai mō te whakawhiti hiko me ngā mahi taraiwa motuka.
Te Manahautanga
He pai mō ngā pāmahana tino kino mai i te -40°C ki te +45°C. Kei te wātea ngā hanganga motuhake mō ngā āhuatanga taiao kino tae atu ki te -45°C.
Paerewa Paerewa Whakaaetanga
Te tutuki katoa i ngā tohutohu IEC 60384-4 me RoHS. Mā ngā pūhaumāota whakamāmā pēhanga whakauru ka tiakina i roto i te aratau rahunga haumaru.
Whakamahinga Mahi
Pūnaha Hiko Ahumahi
He tino pai mō ngā taiao aunoa 24/7 e tino hira ana te kounga o te mana. Ka ārai ā mātou pūnga iahiko i ngā pūnaha pahi DC mai i ngā raruraru raina hiko me ngā rerekētanga kawenga.
Ngā Pūnaha Puku Mōta
He rite ki ngā pūnga hononga-DC i roto i ngā puku auau rerekē (VFD). Ka whakahaere i ngā auau whakawhiti teitei me ngā ngaru hiko me te pupuri tonu i te mahi pahi DC maeneene.
Hurihuri Pungao Whakahou
Ngā wāhanga nui o ngā pūnaha whakawhiti hiko o te rā me te hau. E whakarato ana i te ngaohiko DC pumau mō ngā kōwae IGBT me ngā ara iahiko whakawhiti hiko.
Taputapu Ororongo
He rite ki ngā pūnga pupuri i roto i ngā whakakaha oro pono-teitei. Ka tuku i te iahiko tere i ngā tihi oro hihiri me te pupuri i te iti o te hē.
UPS Punaha
He mea tino nui mō ngā pūtake hiko kore e taea te motumotu, ina hiahiatia te rokiroki hiko me te wā urupare tere mō ngā mahi hiko tārua.
Kia pehea te Works te reira
Ka mahi te pūnga tātari matua i runga i ngā mātāpono pūnga taketake hei whakangawari i te ngaohiko DC e pupuhi ana. Ina whakanohoia i muri i ngā ara iahiko whakatikatika, ka utua i te wā e piki ana te ngaohiko, ā, ka tukuna i te wā e heke ana te ngaohiko.
Mā tēnei huringa utu me te tukunga e whakakī ngā āputa i waenga i ngā pātere kua whakatikatikaina. Ko te hua he putanga DC pumau me te iti o te ngaru.
I ngā huringa ohorere o te kawenga, ka mahi te pūnga hiko hei puna hiko. Ka tukuna tonutia e ia te iahiko hei pupuri i ngā taumata ngaohiko pumau tae noa ki te wā e taea ai e te pūtake hiko te whakarerekē.
Mā te hoahoa iti o te ESR ka whakaitihia ngā hekenga ngaohiko i ngā wā e hiahiatia ana te iahiko nui. Mā tēnei ka pumau te mahi ahakoa i raro i ngā āhuatanga mahi uaua.
Kairangi Hanga
I Xian Xikai Medium And Low Voltage Electric Co., Ltd., ka mau tonu mātou i ngā paerewa kounga pakari puta noa i ā mātou mahi hanga. Mā ā mātou whare hanga kua whakamanahia e ISO9001 ka whakarite kia pumau te kounga o ngā hua.
Ka whakamahia e mātou ngā whakatakotoranga irahiko matatau me ngā tikanga takai tika. Ka whakamatautauria ia pūngao tae atu ki te ine ESR, te whakamātautau ia au ripo, me te huringa wera.
Kei roto i tā mātou tukanga whakahaere kounga te tirotiro rauemi e haere mai ana, te aroturuki i roto i te tukanga, me te manatoko hua whakamutunga. Mā tēnei huarahi whānui ka oatihia te pono o te mahi i roto i ō tono.
He mea nui te tutuki i ngā whakaritenga taiao ki roto i tā mātou rapunga whakaaro hanga. Ka tutuki i ngā hua katoa ngā aratohu RoHS me ngā whakaritenga pūnaha whakahaere taiao.
He aha Kōwhiri Us
He wheako Ahumahi kua whakamatauria
He maha ngā tau o te wheako ki ngā hikohiko mana, ā, e mārama ana mātou ki ō hiahia tono. Ka tautokohia e tā mātou tīma hangarau te whiriwhiri i ngā wāhanga tino pai.
Awhe Hua Matawhānui
Mai i ngā pūnga iahiko ahumahi paerewa ki ngā momo pāmahana-tiketike motuhake, ka tukuna e mātou he otinga mō ngā tono kanorau. Kei te wātea ngā whakaritenga ritenga mō ngā whakaritenga ahurei.
Tātari kounga
Mā te tiwhikete toru me te ISO9001, ISO14001, me te OHSAS18001 ka pumau te kounga me te kawenga taiao. Ka tutuki ā mātou hua i ngā paerewa ā-motu me ngā paerewa ahumahi.
Tautoko Hangarau
Ka whakaratohia e ā mātou miihini mohio he aratohu tono me te kōrero hangarau. Ka āwhina mātou ki te arotau i tō kōwhiringa pūnga tātari matua mō te mahi tino pai me te pono.
Te utu utu
Utu tika mai i te kaihanga, kāore he utu takawaenga. Kei te wātea ngā hekenga rahinga mō ngā ota nui me ngā hononga mahi tahi mō te wā roa.
FAQ
P: Me pēhea taku whakatau i te uara capacitance tika mō taku tono?
A: Ko te kōwhiringa o te kaha ka whakawhirinaki ki te iahiko o tō kawenga, te ngaohiko riipene e whakaaetia ana, me ngā whakaritenga wā pupuri. Ka taea e tā mātou tīma hangarau te āwhina ki ngā tataunga i runga i ō tawhā motuhake.
P: He aha te mea ka tupu mēnā ka nui ake taku iahiko pōrearea kua whakatauria?
A: Mā te nui rawa o te au ripo ka nui te wera o roto, ka pakaru wawe hoki. Me manatoko tonu kei roto tō au ripo RMS i ngā rohe kua tohua.
Q: Ka taea e ēnei pūnga hiko te whakahaere i ngā tāutanga o waho?
Āe, kua hangaia ā mātou pūnga hiko mō ngā mahi o roto, o waho hoki. Ka taea e te hanganga pakari te whakahaere i ngā wero taiao tae atu ki ngā pāmahana tino kino me ngā taumata parahanga III-IV.
P: Kia pēhea te auau o te whakakapinga i ēnei pūnga hiko?
A: Ko ngā wā whakakapinga ka whakawhirinaki ki ngā āhuatanga whakahaere. Ko te roa o te mahi a ngā umanga noa he 5-10 tau ina whakahaerehia i roto i ngā whakaritenga.
Q: He aha ngā mahi ārai haumaru e tika ana i te wā e tāuta ana?
A: Me tuku te pūnga hiko i mua i te whakamahinga. Whakamahia ngā taputapu tiaki tinana e tika ana, ā, whai i ngā tikanga haumaru hiko. Kei roto i ā mātou hua he pūhaumāota haumaru hei whakaiti i te pēhanga.
Whakapā mai
Kei te rite koe ki te whakarei ake i te pono o tō pūnaha hiko me ā mātou otinga pūnga tātari matua ngaio ? Kei te tatari ā mātou tohunga hangarau ki te matapaki i ō hiahia.
Whakapā mai ki tā mātou tīma hangarau i tēnei rā mō ngā taipitopito taipitopito, ngā otinga ritenga, me ngā utu whakataetae. E whakapau kaha ana mātou ki te whakarato i te otinga pūnga tino tika mō tō tono.
Īmēra: serina@xaxd-electric.com
Tukua mātou kia āwhina i a koe ki te whakatutuki i te kounga hiko tino pai me te pono o te pūnaha mā te whakamahi i tā mātou hangarau pūnga iahiko matatau.
Tukua Inquiry
Kia ōrite ana koe
0

