huaPic

Pūnga Tātari Wāhanga-Kotahi

1. Kua rite ki ngā ātete tukunga.
2.Nga hanganga hou me te hangarau hou, te pono nui.
3.Ko te haruru iti, te kaha o te kaha ki te taumaha, kua eke nga taonga hiko ki te taumata teitei o te ao.
4. Mā te hangarau matatau o te ao mō ngā fiusi ā-roto, ka whakarite kia pono te mahi a te hua. Kua whakapaitia te tikanga hononga o te ātete tukunga, ā, kua whakatauhia te raruraru ngaohiko nui o te wāhanga raupapa.
5.Karekau he turuturu, he momo hou o te ngahere nga taika whakahiato argon arc aunoa.
  • Tukunga Tere
  • Tātari kounga
  • 24/7 Ratonga Kaihoko

Kupu Whakataki hua

Pūnga Tātari Wāhanga-Kotahi - Ngā Otinga Kounga Hiko Ngaio

Kupu Whakataki hua

Mēnā e hiahia ana koe ki te whakatikatika hiko pono mō ō pūnaha hiko, ka tukuna e tā mātou Pūnga Tātari Wāhanga-Kotahi te mahi tino pai me te roa. Kua hangaia tēnei wāhanga rokiroki pūngao motuhake mō te mahi tonu i roto i ngā ara iahiko hiko wāhanga-kotahi, e whakangawari ana i ngā piki me ngā heke o te ngaohiko me te pehi i te pokanoa hikohiko. Kei roto i tā mātou Pūnga Tātari Wāhanga-Kotahi te hangarau kiriata polypropylene whakarewa matatau, e whakarato ana i ngā āheinga tātari pai rawa atu mō ngā tono hikohiko mana hou.

Ka whakatauhia e ā mātou pūnga hiko ngā wero nui mō te kounga hiko i roto i ngā taiao ahumahi me ngā taiao arumoni. Ka whakakorea e rātou te whakapōturitanga o te haruru, ka whakaiti i te ngaru o te pahi DC, ā, ka tiaki i ngā taputapu tairongo mai i ngā pikinga haruru e ahu mai ana i te whatunga hiko.

Whakatakotoranga Hangarau

tawhā uara Paerewa
Waahi Ngaohiko 250V - 1000V AC IEC 61071
te puritanga 1μF - 100μF ±5% te manawanui
Temperature Whakahaere -40 ° C ki + 105 ° C Te awhe roa
Rauemi Dielectric Polypropylene Whakarewa Te whakaora whaiaro
ESR <0.1Ω Hoahoa iti te mate
ESL < 10nH Tātari auau teitei
Mātao Ātete > 10GΩ Te wehenga tino pai
Whakatauranga Haumaru UL 810, IEC 61071 Te hanganga ture o te ao
Poraka IP65 e wātea ana Te tiaki i te taiao
ekeeke Ngā kōwhiringa PCB/Chassis Tāutanga ngawari

Nga waahanga matua me nga painga

Hangarau Whakaora-ā-Whaiaro Matatau

He mea hanga ā mātou pūnga hiko ki te kiriata polypropylene whakarewa. Ina puta he pikinga ngaohiko, ka mimiti aunoa te whakarewatanga huri noa i ngā wāhi hapa, kia mau tonu ai te mahi.

Te Mahinga Ngawha Kairangi

I hangaia mō ngā pāmahana tino kino mai i te -40°C ki te +105°C. Mā tēnei whānuitanga mahi ka taea te whakarite kia pono te mahi i roto i ngā taiao uaua.

Hoahoa ESR iti

Mā te iti rawa o te ātete raupapa ōrite ka whakaitihia te wera-ā-unoa i raro i ngā iahiko ngaru nui. Ka roa ake te ora o te mahi a tēnei hoahoa, ā, ka pai ake te pai o te tātari.

Te Kīanga Pūngao Kiato

Mā te hoahoa penapena wāhi ka taea te whakauru ki roto i ngā tahora kāpata whakahaere kiato, me te kore e whakararu i te mahi.

Nga Ahuatanga Haumaru Whakarei

Ka ārai ngā momotu pēhanga nui me te hangarau kiriata wehewehe i ngā pakarutanga kino, ā, ka tiakina tō pūnaha hiko katoa.

Whakamahinga Mahi

Ngā Pūnaha UPS Wāhanga-Kotahi

He tino pai ā mātou pūnga hiko i te wāhanga hononga DC o ngā pūnaha UPS whakawhiti-rua ipurangi. Ka whakangawarihia e rātou te ngaohiko whakatikatika hei tiaki i ngā raraunga nui i te wā e motu ana te hiko me ngā huringa o te whatunga hiko.

Ngā Hurihuri PV Rā

He tino pai mō ngā whakaurunga pūngao rā kāinga mai i te 3kW ki te 10kW. Ka whakaū ēnei waeine i te ngaohiko pahi DC mai i ngā panera pūngao rā, kia tino whai hua ai te aroturuki i ngā pūngao hiko.

Ngā Kaitautoko Waka Hiko

He tino pai mō ngā teihana utu AC Taumata 1 me te Taumata 2. Ka taea e tā mātou Pūnga Tātari Wāhanga-Kotahi te whakahaere i te wiri me te whakarato i te kiato pūngao kiato mō ngā tono motuka.

Nga Puku Motika Ahumahi

He mea nui mō ngā puku auau taurangi me ngā pūnaha servo ina pā tika te kounga o te mana ki te mahi me te roa o te ora o ngā taputapu.

Kia pehea te Works te reira

Ka mahi tō Pūnga Tātari Wāhanga-Kotahi mā te waihanga i tētahi ara iti-ārai mō te haruru auau-tiketike, me te penapena pūngao hiko hei whakakī i ngā āputa i roto i ngā ngaru AC kua whakatikatikaina.

Ka penapena pai te kiriata polypropylene whakarewa i te utu hiko. I te wā e mahi ana, ka utu te pūnga ina piki te ngaohiko whakauru, ā, ka tukuna ina heke te ngaohiko, ka whakangawari i te tuku hiko katoa.

Ka kitea e te haruru whakawhiti auau teitei he ara māmā mā roto i te hoahoa ESL iti o te pūnga. Mā tēnei ka ārai i te pokanoa ki te tae atu ki ngā wāhanga tairongo o raro.

Ka whakahohehia te tikanga whakaora-ā-roto i te wā e neke haere ana ngā hiko, ka wehe aunoa i ngā hapa, ka pupuri hoki i te pumau o te ara iahiko.

Kairangi Hanga

He maha ngā tau o te tohungatanga ki ngā taputapu hiko e kawea mai ana e Xi'an Xikai Medium and Low Voltage Electric Co., Ltd. ki ia pūnga hiko e hangaia ana e mātou. Mā tā mātou pūnaha whakahaere kounga kua whakamanahia e ISO9001 ka pumau te pono o te hua.

Ka whakamahia e mātou ngā raina whakaputa aunoa matatau me ngā taputapu takai tika me te tirotiro i te ahotea taiao. Ka whakamatautauria ia waeine kia pakari tae atu ki te ātete ngaohiko, te ine kaha, me te huringa wera.

Ka whakapai tonu tā mātou tīma rangahau me te whakawhanake i ngā hoahoa i runga i ngā raraunga mahi o te mara me ngā whakaritenga ahumahi hou. Ka mau tonu ā mātou hononga rautaki me ngā kaiwhakarato rauemi matua hei whakarite i te kounga o ngā waahanga.

Ka horapa te mana whakahaere kounga puta noa i tā mātou mekameka tuku. Ka tirotirohia, ka whakamatautauria hoki ngā rauemi e tae mai ana i mua i te whakamahinga whakaputa. Ka whakamatautauria ngā hua whakamutunga ki te 100% hiko me te tauira matapōkere hei whakamana i te roa o te ora.

He aha Kōwhiri Us

He wheako Ahumahi kua whakamatauria

He nui tō mātou wheako ki ngā taputapu tohatoha hiko ngaohiko waenga me te iti, nō reira e mārama ana mātou ki ngā wero o te ao tūturu e pā ana ki ō tono.

Tautoko Hangarau

Ka āwhina tā mātou tīma hangarau i a koe ki te whiriwhiri i ngā whakaritenga pūnga tino pai mō ō hiahia.

Te Raina Whakawhiwhi Whakapono

Kei a mātou ngā taumata rawaka o ngā taonga, me te kaha whakaputa ngāwari kia tutuki ai ō wātaka tuku i ngā wā katoa.

Te utu utu

Ka whakakorehia ngā utu tāpiri a ngā kaiwhakarato mā te utu tika a ngā kaihanga, ā, ka mau tonu ki ngā paerewa kounga teitei.

Pūtāhui Matawhānui

Kei roto i ia pūnga ia he kapinga pūtāhui whānui me te tautoko hangarau urupare puta noa i te huringa ora o te hua.

FAQ

P: He aha te rerekētanga o tēnei mai i ngā pūnga tīmatanga motuka?

A: He mea hanga ā mātou pūnga tātari mō te mahi tonu me te hoahoa ESR iti. Ko ngā pūnga tīmatanga motuka he mea whakamahi mō te wā poto, ā, ka rahua mēnā ka whakamahia mō ngā mahi tātari.

P: He aha ngā pānga ki te roa o te ora o te pūnga?

A: Ko te pāmahana whakahaere te mea matua. Ko ia pikinga pāmahana 10°C ka haurua te roa o te ora mahi e tumanakohia ana. He mea nui te whakahaere tika i te pāmahana.

P: Āhea me whakakapi ēnei pūnga hiko?

A: Whakakapia ina heke te kaha hiko ki te 5-10% i raro i te uara ingoa, ina piki rānei te tauwehenga memeha ki te 2-3 ngā wā o ngā whakatakotoranga tīmatanga.

P: He aha te hiranga o te iti o te ESL?

A: Mā te iti o te kaha o te raupapa ōrite ka taea te whakarite kia whai hua te tātari haruru auau-tiketike, he mea nui tēnei mō ngā pūhiko whakawhiti me ngā kaitahuri hou.

Q: Ka taea e ēnei te tu atu i ngā ngaru hiko?

Āe, ka wehea aunoatia e te hangarau kiriata whakarewa whakaora-ā-ake ngā hapa i puta mai i te ngaru hiko, ka ārai i ngā ara iahiko poto, ka whakaroa hoki i te roa o te mahi.

Whakapā mai

Kei te rite koe ki te whakapai ake i te kounga o tō mana mā te whakamahi i ngā otinga pūnga hiko ngaio? Kei te tatari tonu tā mātou tīma hangarau hei āwhina i a koe ki te whiriwhiri i te Pūnga Tātari Wāhanga-Kotahi tino pai mō tō tono.

Whakapā mai ki a mātou i tēnei rā mō ngā taipitopito taipitopito, ngā whirihoranga ritenga, ngā kōrero hangarau rānei:

Īmēra: serina@xaxd-electric.com

Tukua mātou kia āwhina i a koe ki te whakatutuki i te mahi whakatikatika mana tino pai me ā mātou otinga pūnga pono, kounga teitei.

Tukua