Tauhohenga Raina
14% reactance reactance: Ka pehi i nga orite ki runga ake i te raupapa tuatoru.
27% reactance reactance: Ka pehi i nga orite ki runga ake i te raupapa tuarua.
1.E wātea ana i roto i te toru-waahanga me te kotahi-waahanga maroke-momo whirihoranga rino-matua.
2.Core: Kawemai mai i te matao-hurihia silicon maitai laminations kua wehea e epoxy-kiriata mokowhiti karaihe ki te whakapumau hau āputa.
3.Windings: Ka werohia ki te karaehe H/C enamel-coated waea parahi papatahi mo te parenga teitei me te mahi wahangu.
4.Assembly: Nga toromoka kore-aukume; kua tunua i mua, kua whakamakukuhia, me te waiariki ki te hono i te matua me nga awhiowhio, kia iti ai te ngaronga me te kaha o te pehitanga orooro.
5.Ko nga kapeka-atete me nga waahi; rahi kiato, mama, me te hoahoa rūnanga-hototahi mo te whakaurunga utu-hua.
- Tukunga Tere
- Tātari kounga
- 24/7 Ratonga Kaihoko
Kupu Whakataki hua
Tauhohenga Raina - Ngā Otinga Kounga Mana Tino Pai mō ngā Taupānga Ahumahi
Kupu Whakataki hua
Ina pāngia ō pūnaha hiko e te whakapōturitanga o te haurore me ngā take kounga hiko, me whai otinga pono koe e tuku ana i te mahi pumau. Ko tā mātou Tauhohenga Raina he wāhanga whakauru hiko motuhake kua hangaia hei pupuri i te inductance pumau puta noa i te whānuitanga o ngā kawenga iahiko. He rerekē ki ngā tauhohenga paerewa e pāngia ana e te hekenga o te inductance i ngā iahiko teitei, ka whakarite tā mātou Tauhohenga Raina kounga teitei i te aukati pumau hei tātari pai i ngā raina hiko me te tiaki i ō taputapu utu nui mai i ngā haurore kino.
Kei te wātea ā mātou tauhohenga i roto i ngā tere tauhohenga maha hei whakatutuki i ō hiahia tono motuhake. Ko te tere tauhohenga 7% ka pehi i ngā hauropi kei runga ake i te raupapa 5, ko te tere tauhohenga 14% e aro ana ki ngā hauropi kei runga ake i te raupapa 3. Mō te mana whakahaere hauropi tino whānui, ko tā mātou tere tauhohenga 27% ka pehi i ngā hauropi kei runga ake i te raupapa 2.
Whakatakotoranga Hangarau
| tawhā | Whakapūtātanga |
|---|---|
| whirihoranga | Rino-matua momo-maroke-toru-wāhanga me te wāhanga-kotahi |
| Ngā Reiti Tauhohenga | 7%, 14%, 27% |
| Whakatauranga Impedance | 3%, 5% rānei e pā ana ki te kawenga |
| Whanui | ≥90% o te uara ingoa i te 150% o te auhiko whakatauranga |
| Akomanga Tini | Akomanga H (180°C) Akomanga N rānei (200°C) |
| Rauemi Rawa | Ngā whakapiri maitai silicon hurihuri-makariri kawemai |
| Rauemi Awhiowhio | Waea parahi papatahi kua pania ki te enamel akomanga H/C |
| Taumata Noise | <65 dBA |
| paerewa Tautukunga | IEC 60076-6, UL 508, IEEE 519 |
| Awhe Ngaohiko Whakatau | 0.4kV-40.5kV |
| Whakatauria awhe o naianei | 630A-4000A |
Nga waahanga matua me nga painga
He mea motuhake tā mātou Pūrere Whakautu Raina i te mākete nā tōna hoahoa me te hiranga o te hanga. He mea hanga te uho ki ngā whakakikorua maitai silicon hurihuri-matao i kawemaihia, kua wehea mā roto i ngā āputa karāhe whakakikorua-epoxy hei whakau i ngā āputa hau. Mā tēnei hangarau tika ka ārai i te mākūkū aukume i te wā o ngā takahanga o te iahiko nui.
He mea takai pūmau ngā takai ki te waea parahi papatahi kua pania ki te enamel Akomanga H/C, e whakarato ana i te ātete pāmahana teitei me te mahi puku. Ka whakamahia e tā mātou tukanga huihuinga ngā whakapiri kore-aukume, ā, kei roto ko te tunu-mua, te whakakī korehau, me te whakamaroke wera hei hono pai i te matua me ngā takai.
Ko ngā painga matua ko te whakaiti i te haruru aukume mā te hoahoa matua iti-aukume, te whai huatanga o te wera me te āhua o te takai kua arotauhia, me ngā pito ātete-waikura me te hoahoa kiato, māmā hoki. Ka noho iti tonu ō utu tāutanga me te whakatutuki i te mahi tino pai.
Whakamahinga Mahi
Ka kitea e koe he mea nui ā mātou tauhohenga mō te tiaki i ngā whakaurunga puku auau rerekē, inā koa i roto i ngā mahi aunoa ahumahi taumaha pēnei i ngā mira maitai, te tukatuka pepa rānei. Ka mahi te Tauhohenga Raina hei ārai i waenga i te tuku whatunga koretake me ngā hikohiko puku tairongo, ka mimiti i ngā whakawhiti taputapu.
I roto i ngā tono pūngao whakahou, ka whakangawarihia e ā mātou tauhohenga te rere o te iahiko DC i roto i ngā kaitahuri hiko o te rā me te pāmu hau i mua i te tahuritanga, i te tātari rānei i ngā ngaru AC i mua i te werohanga whatunga. Mō ngā tono motuka ara-roa i roto i ngā pūnaha HVAC me te maimoatanga wai, ka whakaitihia e ā mātou tauhohenga ngā āhuatanga dv/dt ina neke atu i te 100 putu te tawhiti o te taura i waenga i ngā puku me ngā motuka.
Kia pehea te Works te reira
Ka mau tonu te tūnga o te raina i roto i tō Pūwhakawhiti Raina i tua atu i te iahiko kua whakatauria, tae atu ki te 150-200% o te kaha kua tohua. Mā ngā āputa hau tika i roto i tō mātou matua maitai silicon kounga teitei e whakahaere te kiato rere me te ārai i te mākū. Mā tēnei ka whakarite kia rite te mahi induction ahakoa i raro i ngā āhuatanga kawenga rerekē.
Mā te tukanga whakakī i te pēhanga korehau ka hangaia he hanganga pumau, me te whakaiti i te haruru e rangona ana. Mā te āhua o te takai kua arotauhia ka whakaitihia te pānga kiri me ngā ngaronga o te ia hurihuri, ka noho iti te pāmahana mahi, ka roa ake te roa o te mahi.
Kairangi Hanga
I Xi'an Xidian Medium and Low Voltage Electric Co., Ltd., ka mau tonu tā mātou whakahaere kounga tino pakari puta noa i tā mātou tukanga hanga. Kua whiwhi tō mātou whare i ngā tiwhikete pūnaha whakahaere kounga ISO9001, pūnaha whakahaere taiao ISO14001, me te pūnaha whakahaere hauora me te haumaru mahi OHSAS18001.
Ka whakahaerehia e mātou he whakamātautau whānui mō ia waeine, tae atu ki ngā whakamātautau ōritetanga o te inductance i te 0%, 100%, me te 150% o te iahiko kua whakatauria. Mā ngā whakamātautau kaha dielectric teitei ka whakarite kia tutuki te haumaru o te whakamahana, ā, mā ngā whakamātautau pikinga pāmahana o te wera ka manatoko i te mahi wera i roto i ngā rohe akomanga whakamahana.
He aha Kōwhiri Us
Ka taea e koe te whakawhirinaki ki tā mātou hītori mahi kua whakamātauhia hei kaiwhakarato ratonga whakauru pūnaha taputapu tohatoha hiko ngaohiko reo-waenga me te iti. Kei roto i tā mātou kohinga hua e 9 ngā kāwai, 34 ngā raupapa, me te neke atu i te 100 ngā momo, e tutuki katoa ana i ngā paerewa ā-motu me te ao.
He nui ngā wheako o tā mātou tīma hangarau ki ngā otinga kounga hiko, ā, e whakarato ana mātou i ngā otinga pūnaha katoa kua whakaritea mō ō hiahia. Me ngā hua kua whakatauria kia taea te whakamahi tae atu ki te 4000 mita i runga ake i te taumata o te moana, ka taea e koe te whakawhirinaki ki ā mātou taputapu i roto i ngā taiao uaua o te ao.
FAQ
P: He aha te rerekētanga i waenga i ngā reiti tauhohenga?
A: Mā ngā reiti tauhohenga teitei ake ka whānui ake te pehi i te haurore. Kōwhiria te 7% mō te haurore tuarima me runga ake, 14% mō te haurore tuatoru me runga ake, 27% rānei mō te haurore tuarua me runga ake.
P: Me pēhea taku whakatau i te whakatauranga parenga tika?
A: Ko te tikanga, ka tūtohu mātou kia 3%, kia 5% rānei te ātete e pā ana ki tō kawenga. Ka taea e tā mātou tīma hangarau te āwhina i a koe ki te tatau i te whakatauranga tino pai i runga i tō tono motuhake.
Q: He aha te tiaki e hiahiatia ana?
A: He iti noa te tiaki e hiahiatia ana mō tā mātou hoahoa momo-maroke. Mā te tirotiro tirohanga me te tirotiro whakaahua wera auau ka tino pai te mahi me te kite wawe i ngā raruraru.
Whakapā mai
Kua rite koe ki te whakapai ake i te kounga o tō mana me ā mātou otinga Linear Reactor kounga teitei ? Kei te tatari ā mātou tohunga hangarau hei āwhina i a koe ki te whiriwhiri i te whirihoranga tika mō ō hiahia tono motuhake.
Mō ngā taipitopito taipitopito, ngā otinga ritenga, te tautoko hangarau rānei, whakapā mai ki a mātou i tēnei rā ki serina@xaxd-electric.com . E whakapau kaha ana mātou ki te whakarato i ngā otinga kounga hiko hei pupuri i te rere pai me te whai hua o āu mahi.
Tukua Inquiry





