Kōwhiria he Pūnaha Whakawhiti Pūmanawa o Waho: He Aratohu Whānui
2026-06-15 15:40:51
I te wā e whiriwhiri ana koe i tētahi whakawhiti hiko Pūmanawa o Waho , me kimi e koe he taurite i waenga i te tika hangarau me te pakari i roto i ngā taiao uaua. Ko ēnei taputapu ine ngaohiko ngā wāhanga tino nui o te hanganga hiko i roto i ngā teihana hiko, ngā wheketere, me ngā whatunga ratonga. Ka whakahekehia e rātou te ngaohiko teitei ki ngā taumata ka taea e ngā mita me ngā pana haumaru te whakahaere. Me aro atu ngā whakawhiti hiko Pūmanawa o Waho ki te ua, ngā huringa pāmahana, te mārama UV, me te paru, ko te tikanga me tino pai te kounga o ngā rauemi me te kaha o te hoahoa. E kōrero ana tēnei aratohu mō ngā mea nui e pā ana ki te wā mahi, te tika, me ngā utu katoa o te mana pupuri. Ka āwhina i ngā tīma hoko ki te whakataurite i ngā whakaritenga taputapu ki ngā meka whakahaere kia kore ai e puta he hapa utu nui, kia kore ai rānei e pakaru wawe ngā taputapu i te mara.
Te Mārama ki ngā Whakawhiti Pūmanawa o Waho: Ngā Kaupapa Taketake me ngā Mahi
He aha te mahi a ngā Transformers Pūmanawa o Waho?
Ina tāutahia ngā whakawhiti hiko hiko ki waho, ka whakahekehia ngā tohu hiko hiko hiko-teitei ki ngā putanga tuarua noa, arā, ko te 100V, ko te 120V rānei. Nā tēnei ka haumaru te hono atu ki ngā mita, ki ngā whakawhiti hiko, me ngā pūnaha aroturuki. I roto i ngā pire hiko, he mea nui te ine tika i ngā hiko, ā, i roto i ngā whare ahumahi, he mea nui anō hoki te whakaritenga o ngā whakawhiti hiko tiaki. Ko te whakawhiti hiko hiko tāuru 35kV Pūmanawa o Waho, pērā i ngā momo whakarewa kapia epoxy e tutuki ana i ngā paerewa IEC 61869-1 me te 61869-2, ka whakahekehia te hiko ki ngā uara putanga 10kV e pai ana mō ngā taputapu paerewa. Ka puta tēnei huringa mā te whakaawe hikohiko i roto i te matua aukume, me te iti rawa o te hapa i roto i te koki me te ōwehenga o te wāhanga.
Ngā Āhuatanga Hanganga i Hangaia mō ngā Huānga
Nā te mea he tino uaua te mahi o waho, me whai tikanga hanga motuhake. Ko te matua hikohiko me ngā takai he mea whakakikorua katoa ki te whakarewa kapia epoxy. Ko te tikanga o tēnei, kāore he āputa i roto i te rauemi e uru ai te makuku, e puta ai ngā mura o roto. He tino rerekē tēnei hoahoa hiri katoa i ngā kōwhiringa kua whakakiia ki te hinu, nō reira kāore koe e hiahia ki te mahi i tetahi mahi tiaki pēnei i te tirotiro i te taumata wai, te whakatika rānei i ngā turuturu. Ko ngā whare ātete-huarere me te whakatauranga IP65, teitei ake rānei, ka tiaki i ngā wāhanga o roto mai i te puehu me ngā pupuhi wai. Ko ngā waho polymer kua whakapūmauhia e te UV ka ārai i a rātou kia pakaru ina roa te pānga ki te rā tika. Ko ngā taputapu me ngā hononga i hangaia ki te maitai kore waikura ka roa ake te ora i ngā wāhi takutai moana e tere ake ai te pakaru o ngā rauemi i te rehu tote.
Ngā Taupānga puta noa i ngā Hanganga Hiko
Ka whakamahia ngā whakawhiti hiko i roto i ngā wheketere hei tirotiro i te kounga o te hiko e haere ana ki ngā mīhini CNC me ngā raina huihuinga aunoa. Mēnā ka heke te hiko, ka pāngia rānei e te whakararuraru o te rangi, ka pā tika ki te nui o te mahi e mahia ana. Ka whakamahia ēnei taputapu e ngā pokapū raraunga hei whakarite kia tika tonu ngā inenga mō te whakawhiti hiko me te taurite o ngā kaihanga hiko tārua. Ka whakauruhia ngā whakawhiti hiko pūmanawa o waho e ngā kaimahi tuku me te tohatoha i ngā teihana hiko hei whakarato tohutoro hiko mō ngā whakawhiti tawhiti e tiaki ana i ngā raina tuku e rere ana mō ngā rau maero. Me ine tika te hiko hei tukutahi i ngā putanga whakawhiti me te auau whatunga me te koki ā-wāhanga i roto i ngā wāhi pūngao whakahou pēnei i ngā pāmu rā me ngā papa hau. Mā tēnei ka ārai i ngā momotu utu nui i te wā e puta ana ngā kapua, ngā hau pūngao rānei.
Ngā Whakawhiti Pūmanawa o Waho, o Roto rānei: Ngā Rerekētanga me ngā Whakaaro Kōwhiringa
Ngā Rerekētanga Hanganga me te Taiao
Ko ngā rerekētanga katoa o te hoahoa i waenga i ngā whakawhiti hiko o waho me roto, nā te taiao te take. Ka mahi ngā waeine o roto i roto i ngā rūma whakawhiti hiko e whakahaeretia ana te āhuarangi, e pupuri ana i te pāmahana kia pumau, te haumākū kia iti, ā, e whakamahi ana i ngā pūnaha HVAC hei ārai i te puehu me ngā paitini kia kore ai e uru ki roto i ngā rūma. Mā tēnei taiao whakahaeretia ka māmā ake ngā pūnaha whakamahana, ā, ka iti ake te kaha o ngā pakitara, ka whakaiti i te utu o ngā rauemi me te rahi o te whare. I roto i ngā whakawhiti hiko Pūmanawa o Waho , ka taea e ngā pāmahana te rerekē mai i te -40°C ki te +55°C. Ko te tikanga me kaha ngā rauemi whakamarumaru ki te pupuri i tō rātou kaha hiko puta noa i tēnei awhe me te kore e pakaru, e wehe rānei. Ina ua, ina hukarere, ina hukapapa rānei, me whakaneke te whare kia rere te wai mai i ngā pūwāhi hononga. Ka ārai ngā wehewehe porcelain, rapa silicone rānei i te nekeneke o te mata ina mākū.
Ngā Whakaritenga Mahi me te Tiaki
Ahakoa e mahi ana te whakawhiti hiko pea i roto, i waho rānei, me tutuki i a ia ngā whakaritenga o te karaehe tika ōrite: 0.2, 0.5 rānei ngā whakatauranga karaehe mō ngā mahi ine moni whiwhi, me ngā whakatauranga karaehe 3P mō ngā mahi haumaru whānui. Engari he rerekē ngā pānga o ngā pēhanga taiao ki te ōritetanga tika mō te wā roa. He nui ake ngā huringa pāmahana o ngā waeine o waho, ka whānui, ka whakaiti hoki i ngā waea whakapuru matua me ngā waea takai. Ko ngā pūnaha kume koiri me te here matua whakahaeretia i roto i ngā hoahoa kounga teitei ka ea ai tēnei mā te pupuri i te pumau ā-mīhini mō ngā tekau tau. Ko ngā whakawhiti hiko pea o waho me te whakamarumaru kapia epoxy me tiaki pinepine atu i ngā hoahoa kua whakakiia ki te hinu nā te mea ka pupuri te hanganga hiri i te makuku, ka whakaiti i te ātete o te whakamarumaru. Tērā pea me horoi pinepine te puehu huri noa i ngā kōhao hau i runga i ngā waeine o roto, engari me karo koe i te tuku i te huarere kia kino ngā mata o waho me ngā hiri.
Ngā Whakaaro mō ngā Utu me te Tātaritanga o te Mana Whakahaere Katoa
Nā te pai ake o te whakamarumaru, ngā ārai ātete huarere, me ngā rauemi kāore e waikura, he 25–40% te utu tuatahi mō ngā whakawhiti hiko Outdoor Potential i ngā utu rite o roto. Ina tirohia e ngā kaiwhakahaere hoko te utu katoa o te mana whakahaere, me whakauru ngā utu tāutanga. Ko ngā waeine o waho ka whakairihia ki runga i ngā hanganga motuhake, i ngā papa pou rānei, ka tāpirihia ngā utu turanga me ngā utu hanganga kāore i roto i ngā tāutanga taputapu whakawhiti o roto. Engari ka whakakorea e ngā whakawhiti hiko Outdoor Potential te hiahia ki te hanga rūma whakawhiti motuhake, ka penapena moni i ngā utu hanga me ngā rawa i roto i ngā whare he iti te wāhi. Me whai whakaaro ki te urunga atu ki te whakatika i roto i te tātari utu huringa ora. Hei tauira, ko te tirotiro i ngā waeine o waho me whakamahi pea i ngā taraka peere, i ngā arawhata rānei, engari ka taea te eke ki ngā taputapu o roto mā te hikoi ki runga. Ko ngā taumata pono rerekē ka pā ki te utu whakakapinga. Hei tauira, ki te pakaru tetahi waeine o waho, me whakarite pea he maha ngā whāngai mō te motumotu. I tetahi atu taha, ko te ine ine o roto ka hoatu he herekore mahi ki a koe i te wā e whakatikatika ana.
Me pēhea te whiriwhiri i te Pūwhakawhiti Pūmanawa o Waho tika mō tō kaupapa?
Te Whakataurite i ngā Whakatakotoranga Hangarau ki ngā Whakaritenga Pūnaha
Ko te ngaohiko paerewa o te pūnaha me te tawhē haumaru ka whakamahia hei whiriwhiri i te akomanga ngaohiko. Hei tauira, ka mahi ngā whakawhiti hiko 35kV kua whakatauria me ngā whatunga tohatoha 34.5kV nā te mea ka whakaratohia he taunga whakamātao mō ngā ngaohiko poto e puta ana i te wā o ngā mahi whakawhiti, i ngā raruraru whenua rānei. Mā ngā reiti auau i te hototahi takirua 50/60Hz ka taea te whakamahi i ngā kaupapa huri noa i te ao me te kore e hiahia ki te whakarerekē i ngā whakaritenga. Ko te kaha o te iahiko matua kua whakatauria, ka taea te 600A, te 800A rānei, e whakaatu ana ki a koe te pai o te mahi wera i te kawenga katoa. Mā tēnei ka kore e neke te tika ina hangaia ngā mara hikohiko e ngā kaihanga hiko tata, e ngā tauhohenga rānei. Ko te kaha kawenga putanga, e hoatu ana i roto i ngā volt-amperes (VA), me teitei ake i te aukati katoa o ngā mita hono katoa, ngā pana, me ngā taputapu tohu mā te 20%. Ko te whiriwhiri i te akomanga tika e whakawhirinaki ana ki te mahi kei te ringa. Hei tauira, me 0.2 te tika o te akomanga o te ine moni whiwhi, ko te whakawhiti tiaki ka taea te mahi me ngā wae akomanga 0.5.
Te Aromatawai i nga Tohu Kaituku me nga Tiwhikete
Whakahaerehia ngā arotakenga tohu mā te arotake i ngā pūnaha kounga me ngā āheinga hanga. Mā te tiwhikete ISO 9001 ka whakarite kia whakapumautia te whakahaere kounga. Mā ngā tiwhikete hua IEC 61869 ka whakaatuhia te tutuki i ngā whakaritenga haumaru o te ao. Mā ngā whakaaetanga ā-rohe (ANSI C57.13, GB 20840.2-2014) ka whakaatuhia te ngāwari o ngā ture. Ko ngā pūtāhui PT o waho e 5-10 tau te roa. Ka tere ake te tautoko tono a ngā kaiwhakarato me ngā pokapū ratonga ā-rohe i ngā kaihanga mamao.
Te Tāutanga, te Tiaki, me ngā Tikanga Pai rawa atu mō ngā Whakawhiti Pūmanawa o Waho
Nga Aratohu Whakauru-a-Taahiraa
Ko te tirotiro i te kaha me te papatahi o te turanga te taahiraa tuatahi ki te whakarite i te papaanga. Nā te mea ka pā te taumahatanga miihini ki ngā ārai uku me ngā pūwāhi hononga mēnā kāore i te ōrite ngā mata whakairinga. Ka whakatakotoria ngā whakawhiti Pūmanawa o Waho ki runga i ngā hanganga rino motuhake, ngā papa raima, ngā rawhi pou rānei i hangaia hei whakahaere i ngā kawenga hau me ngā kaha rū whenua e hiahiatia ana e ngā ture hanga whare ā-rohe. Kia haumaru ai ngā taputapu, kia tika ai hoki ngā inenga, me hono ngā kaiārahi whenua ki te whatunga whenua o te teihana hiko me te ātete i raro i te 1 ohm. Me whakamātau tēnei mā roto i ngā whakamātautau hinganga-o-te-pūmanawa i mua i te tahuritanga o te taputapu. Hei ārai i ngā hononga kei wetekina, kei puta ai te hekenga wera me te ngaohiko, me whakakīkī ngā hononga tuatahi ki ngā tīwiri pito mā te whakamahi i te taipana e whakahaerehia ana e te kaihanga. Ka wehea ā-tinana ngā raina hiko au-teitei mai i te waea tuarua e haere ana ki roto i ngā paipa, i ngā paepae taura rānei. Mā tēnei ka iti rawa te pokanoa hikohiko ka pā ki te tika o te inenga.
Ngā Kaupapa Tiaki Auau me ngā Whakatau Rapanga
Te horoi ā-tau: tirohia te kounga o te whare, tirohia ngā pakaru porcelain, ngā hiri huarere. Ka kitea e te whakaahua wera ngā hononga wera (10°C i runga ake i te taiao e tohu ana i te ngoikore o ngā taputapu). Ngā whakamātautau ātete ārai me ngā mita megohm 5kV—me tirotirohia ngā pānui i raro i te 1000 megohm. Tirohia te ngaohiko putanga tuarua ki ngā tohutoro kua whakatikatikaina. Ko ngā fiusi tuarua kua pupuhi te nuinga o te wā e tohu ana i ngā ara iahiko poto o raro, ehara i te hapa o te whakawhiti hiko.
Te Whakamamae i nga Wero Taiao
Ngā wāhi takutai: horoia ngā mata o waho ki te wai māori ia toru marama hei tango i ngā paparanga tote e kawe ana i te hau. Ngā pāmahana tino kino: tāpirihia ngā mea whakamahana hei ārai i te haukū; whakamahia he ārai rā, he paninga whakaata rānei i ngā koraha. Tāutahia he taiapa tiaki huri noa i ngā PT e mau ana i te turanga hei ārai i ngā kararehe me ngā kaipahua. I ngā wāhi e pāngia ana e te hukapapa, whakahaerehia he tirotiro ārai hotoke auau. Mā ngā hiri whakauru taura wera ka ārai i te urunga o te wai.
Ngā Tirohanga Hoko: Te Utu, te Tukunga, me te Pono o te Kaiwhakarato
Te Mārama ki ngā Taurangi Utu me te Whakamahere Tahua
Ka pāngia te utu o te whakawhiti hiko o waho e te akomanga ngaohiko, ngā whakaritenga tika, me ngā rauemi hanga . Kua whakaritea te utu turanga mō ngā waeine paerewa 35kV me te akomanga tika 0.5 me te whakamarumaru kapia epoxy. Mā te whakapai ake ki te akomanga tika 0.2 mō te ine moni whiwhi ka tāpirihia he utu tāpiri nā te mea he iti ake ngā rohe whakaputa me te whiriwhiri i tētahi rauemi matua rerekē. Ko ngā tono mō te whakaritenga, pērā i ngā ngaohiko tuarua kāore i te paerewa, ngā whakatakotoranga whakairi ahurei, ngā whakatauranga ru teitei ake rānei, ka piki ake ngā utu hangarau me te tipu o ngā wā tatari. Ka pāngia ngā utu waeine e te rahinga i te huarahi nui; ka taea e ngā tīma hoko e tono ana i te 50, neke atu rānei ngā waeine mō ngā kaupapa raina tuku te whiwhi penapena tae atu ki te 25–25 ōrau ki te whakarite ki te hoko i tētahi waeine kotahi. Ka pāngia ngā hoko o te ao e ngā tikanga utu me ngā huringa o ngā moni. Mō ngā kaupapa e roa ana i ngā tau pūtea maha, he mea mohio te whakatakoto tahua wawe me te whakamahi i ngā rautaki hokohoko.
Ngā Wā Arataki me te Whakaritenga Tukunga
Ka tukuna ngā PT o waho paerewa i roto i ngā wiki 8-12 i muri i te whakaū ota. E 16-20 wiki te roa mō ngā waeine i hangaia kia rite ki te hiahia mō te whakaaetanga hoahoa, te whakamātautau tauira, me te whakarite whakaputa. Me whai kaikawe motuhake me ngā taura me te inihua mō ngā taputapu hiko taumaha e tukuna ana ki ngā utanga. Whakaritea ngā rā tuku ki ngā whāinga hanga kia kore ai e nui te utu rokiroki i te papaanga. Whakaurua ngā mahi tirotiro: te manatoko i te papa ingoa, te tirotiro i ngā pakaru o te tuku, te whakamātautau whakaae.
Te Tāutu i ngā Kaiwhakarato Pono me ngā Hanganga Tautoko
Tirohia ngā tohutoro mai i ngā kiritaki o mua me ngā tono rite. E whakaatu ana ngā kaihanga kua roa e noho ana ki te mākete, kua whakaputaina ngā rangahau take, me te hiahia ki te toro atu ki ngā wheketere. Te urunga tautoko hangarau: te hangarau tono mō te āwhina i ngā whakatakotoranga; te ratonga kiritaki 24/7 mō te whakatau raruraru mara. Ngā tikanga pūtāhui mārama e kapi ana i ngā hapa me ngā tikanga whakakapinga. Ko ngā tiwhikete ISO 14001, OHSAS 18001 rānei e whakaatu ana i te kawenga hanga.
Opaniraa
Me taurite ngā whakaritenga hangarau ki te roa o te ora o te taiao me ngā utu o te huringa ora i te wā e whiriwhiri ana i tētahi whakawhiti hiko Pūmanawa o Waho . Ko ngā taumata ngaohiko, te karaehe tika, te momo whakamarumaru, me te tutuki i ngā ture te pūtake hangarau. Ko te angitu o te mahi mō te wā roa e whakawhirinaki ana ki tōna tū pakari ki te huarere, ki tōna ngāwari ki te tiaki, me te pai o te tautoko a te kaiwhakarato i ana hanganga. Ko te whakamahi i tētahi whakawhiti ngaohiko o waho, o roto rānei, e whakawhirinaki ana ki te wāhi e hiahia ana koe ki te whakanoho, te nui o te utu, me te pehea e pai ai koe ki te whakahaere i te tiaki. Ko te whakawhiti ngaohiko o waho 35kV mai i Xi'an Xikai e whakaatu ana me pēhea te whakamahi i te hangarau kapia epoxy o nāianei hei ine tika i te ngaohiko i roto i ngā āhuatanga mara uaua, me te whakatutuki i ngā paerewa o te ao me te whakaputa hua kounga teitei. He pai ake mā ngā tīma hoko te titiro ki ngā utu katoa o te mana whakahaere kaua ki te utu hoko tuatahi anake. Ko te tikanga o tēnei me whai whakaaro ki ngā mea pēnei i ngā utu tāutanga, ngā hiahia tiaki, me te pono o te pūnaha i roto i ngā wā whakatā.
FAQ
1. He aha ngā painga o ngā whakawhiti hiko o waho ki te whakataurite ki ngā whakawhiti hiko o roto?
Ka whakakorea e ngā whakawhiti hiko o waho te hiahia mō ngā rūma whakawhiti hiko motuhake, e whakaiti ana i ngā utu hanga me ngā hiahia whenua i roto i ngā whare he iti te wāhi. Ka taea te waiho tuwhera ngā taupoki ātete huarere me te whakatauranga IP65, teitei ake rānei, ki te ua, ki te hukarere, me ngā pāmahana tino kino. He pai ake te whakamarumaru kapia epoxy ki te pupuri i te makuku i ngā hoahoa o roto tawhito kua whakakiia ki te hinu. Ka taea te whakairi ki runga i ngā hanganga o nāianei, pērā i ngā pou, i ngā papa raima rānei, me te kore e nui te mahi hanga. Heoi, me pai ake te whakamarumaru me te haumarutanga o ngā waeine o waho ki te waikura, ka nui ake te utu ki te hoko i te tuatahi ki te whakataurite ki ngā waeine o roto e mahi ana i te mahi hiko kotahi.
2. Kia pēhea te auau o ngā tirotiro tiaki kia pai ai te mahi a te whakawhiti hiko?
Me tirotiro ngā kanohi o ngā whakawhiti hiko o waho i te tau kotahi kia tino pakari ai te anga, kia piri ai ngā hononga, ā, kia pai ai te āhua o te whakamarumaru. I ia rua ki te toru tau, ka kitea e ngā matawai whakaahua wera ngā raruraru hononga i mua i te puta. I ia rima tau, ka whakarite ngā whakamātautau ātete whakamarumaru kei roto tonu te kaha o te hiko i ngā rohe e whakaaetia ana. I ngā wā tirotiro ine ā-tau, i ngā wā rānei e āwangawanga ana mō te tika, me tirotiro te ngaohiko putanga tuarua ki ngā paerewa kua whakaritea. Ka taea te karo i te aroturuki mata mā te horoi i te taha waho o ngā taiao kino i ia ono marama, pērā i ngā wāhi takutai moana e pāngia ana e te wai tote, i ngā wāhi ahumahi tino poke rānei.
3. Ka taea te whakarite i ngā whakawhiti hiko o waho mō ngā tono ahumahi uaua?
He maha ngā wā ka whakaritea ngā whakawhiti hiko o waho e ngā kaihanga kia tutuki ai ngā hiahia motuhake. Kei roto i ngā huringa ko ngā ngaohiko tuarua kāore i te paerewa hei mahi me ngā pūnaha ine tawhito, he tawhiti roa ake mō ngā wāhi he nui te parahanga, he whakapakari rū whenua mō ngā wāhi e pāngia ana e ngā rū whenua, me ngā whakatakotoranga whakairi rerekē ka taea te whakauru ki ngā teihana hiko he iti te wāhi. Mō ngā mahi taiwhanga tika, ka whakamahia ngā akomanga tika ritenga he kikī ake i ngā tohu 0.2 noa. Mā ngā takai tuarua maha ka taea te hono i ngā ara iahiko ine me te haumaru i te wā kotahi, me te pupuri i te hiko kia wehea. Kia tutuki ai ngā hoahoa ritenga i ngā whakaritenga mahi, ko te wā tatari mō te hoko he 8 ki te 12 wiki te roa atu i ngā taonga paerewa. Hei whakamana i te hangarau me ngā tukanga whakamātautau.
Te mahi tahi me Xi'an Xikai mō ngā otinga pono mō te whakawhiti pūmanawa o waho
Hei kaihanga whakawhiti hiko Outdoor Potential me te toru tekau tau o te wheako hangarau, kua rite a Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. ki te tautoko i ō hiahia hanganga ine ngaohiko. Ka whakamahia e tā mātou whakawhiti ngaohiko waho 35kV te hangarau whakamarumaru kapia epoxy me te mana kounga tino pakari hei hoatu ki ngā teihana hiko, ngā tipu ahumahi, me ngā whatunga ratonga te tika o te ine me te roa o te wā e hiahiatia ana e rātou. Ka taea e koe te īmēra ki tā mātou tīma tohunga ki serina@xaxd-electric.com , amber@xaxd-electric.com , luna@xaxd-electric.com rānei ki te kōrero mō ngā hiahia tono me te tiki i ngā taipitopito e tika ana mō tō kaupapa.
Tohutoro
1. Te Komihana Hikohiko o te Ao. Ngā Whakawhiti Taputapu - Wāhanga 2: Ngā Whakaritenga Tāpiri mō ngā Whakawhiti Ngaohiko. Paerewa IEC 61869-2:2012.
2. IEEE Power and Energy Society. Aratohu IEEE mō ngā tono tuku hiko tiaki ki ngā raina tuku. Paerewa IEEE C37.113-2015.
3. Te Rōpū Kaihanga Hiko ā-Motu. Ngā Whakaritenga mō ngā Whakawhiti Taputapu. Paerewa ANSI C57.13-2016.
4. Kulkarni, SV, me Khaparde, SA Hangarau Whakawhiti: Hoahoa, Hangarau, me te Tātaritanga. CRC Press, Putanga Tuarua, 2017.
5. Rōpū ABB. Ngā Whakawhiti Ngaohiko: Aratohu Tono mō te Tiaki me te Ine. Whakaputanga Hangarau, 2019.
6. Te Whare Rangahau Hiko. Te Whakamātautau Papa o ngā Whakawhiti Taputapu: Ngā Mahi Pai me ngā Tikanga Tātaritanga. Pūrongo EPRI 3002015591, 2020.