Ka āraihia e ngā ārai uira ngā pikinga ngaohiko mai i te uira me ngā ngaru whakawhiti. He ārai hiko tēnei i te taunoa, engari ina neke ake te ngaohiko i ngā taumata haumaru, ka heke tonu tōna ātete hei huri i te kaha kino ki te whenua. Mā tēnei tikanga nui ka tiakina ngā taputapu utu nui me te pono o te whatunga hiko.

te hopu uira

He aha te Uira hopu?

Te mahi me te tūranga

He mea nui ngā ārai uira ki ngā hanganga hiko o ēnei rā. Ko ēnei taputapu matatau te rārangi tuatahi o te parepare i ngā tūponotanga pakaru nui o te pūnaha hiko. He pana atamai ngā ārai uira e whakahohe ana ina raru ngā taumata ngaohiko kino i ngā taputapu hiko.

Whakatakotoranga Hangarau

Mā ngā rauemi motuhake, ko te nuinga he konutea waikura, ka hoatu he āhuatanga hiko ahurei ki te taputapu. He tino teitei te ātete o ēnei rauemi i raro i te ngaohiko whakahaere paerewa, e kore ai e kitea e te pūnaha hiko. He ataahua te urupare ngaohiko kore-raina o ngā pūmau hiko hou. Mā ngā mahi uira me te whakawhiti ka puta he pikinga ngaohiko ka whakaiti i te ātete o te pūmau hiko i roto i ngā maikorohekona. Mā tēnei urupare tonu ka hangaia he ara whenua iti te ātete, ka tahuri ke i te kaha morearea mai i ngā taputapu tairongo.

Ngā Painga o te Whare Ahumahi

Nā te mea e hiahiatia ana he hiko pono, ka whai hua ngā whare ahumahi i tēnei parenga. Kāore e taea e ngā whare hanga e whiwhi miriona tāra ana te utu i ngā pakaru o ngā taputapu e pā ana ki te raruraru hiko. Me tiaki tonu ngā pokapū raraunga e pupuri ana i ngā pūnaha mōhiohio nui mai i ngā āhuatanga rerekē o te hiko ka taea te whakakore i ngā raraunga.

Ngā Whakatairanga Hangarau me te Pūtaiao Rauemi

Ka whanake haere te hangarau o ēnei taputapu me te whanaketanga o te pūtaiao rauemi me te hanga. Ka ātete ngā whare polymer i roto i ngā ārai hou ki te pirau o te taiao, ā, he pai ake te kaha miihini i te porcelain.

Te Raruraru Ka Whakatauhia

Te Mōrearea o te Ngaohiko Nui

He maha ngā wā ka puta ngā āhuatanga hiko nui rawa atu, ā, ka taea e te uira te whakangaro i ngā miriona tāra o ngā taputapu i roto i ngā hēkona. Ka tukuna e te uira ngā ngaru kaha nui mā roto i ngā raina hiko i ngā tere teitei, e rapu ana i te ātete iti rawa ki te whenua. Ki te kore he parenga, ka whakangaromia e tēnei kaha ngā whakawhiti hiko, ngā whati ara iahiko, me ngā hiko tairongo.

Ngā Pānga ki ngā Whare Hanga

Ko ngā whare hanga e tino pāngia ana e ngā pikinga ngaohiko. Nā ngā kaiwhakahaere arorau ka taea te whakarite, ngā puku auau rerekē, me ngā pūnaha aroturuki rorohiko ka whakaraeraehia ngā raina whakaputa ki ngā ngaohiko tauwhiro. Mā te whiunga kotahi o te uira ka mutu te whakaputa, ka pau te moni, te wā, me ngā whanaungatanga ki ngā kiritaki.

Ngā Pānga Tino Hira ki ngā Pūnaha Hōhipera

Ko tētahi atu whakamahinga nui e pā ana te kounga hiko ki te haumaru o te tangata ko ngā hōhipera. Me whai hiko pumau ngā mīhini MRI, ngā mīhini manawa, me ngā pūnaha aroturuki tūroro. Ka taea e ngā raruraru hiko te whakararu i ngā taputapu tikanga, ka tūpono ai te oranga o te tūroro.

Ngā Wero o te Kamupene Ratonga

He uaua ki ngā kamupene ratonga te pumau o te whatunga whakawhiti puta noa i ngā whatunga tuku nui. Kei te whakararu tonu ngā mahi whakawhiti, ngā hapa, me te huarere i te pono o te pūnaha. Ia motuhanga ka nui te moni whiwhi a ngā ratonga, ā, ka pakaru hoki tō rātou pono.

Te Pānga Pūtea Nui Ake

Ehara i te mea ko ngā utu whakakapinga taputapu anake te pānga pūtea. Nā te korenga o te pakihi, te ngaronga o te hua, me ngā whakatikatika ohorere ka nui ake te utu mō te tiakitanga ngaru koretake. Whai muri i tētahi huihuinga nui o te ngaohiko, ka utua e ngā pūnaha tiakitanga ngaru kua tāuta tikahia ā rātou ake utu i roto i te wā kore mahi me ngā utu whakakapinga taputapu, e ai ki ngā rangahau.

Ngā ngoikoretanga o te pūnaha hiko o ēnei rā e whanake ana

Ka nui ake te aro o ngā pūnaha hiko hou ki ngā rerekētanga ngaohiko i te whanaketanga o te mamati. Ka hangaia e ngā hangarau whatunga atamai, te whakaurunga pūngao whakahou, me te aunoatanga ahumahi he ngoikoretanga hou e hiahia ana ki te tiaki matatau.

Nga waahanga matua me te mahi ruku hohonu

Ngā Āhuatanga Matatau o ngā Pūrere Whakamarumaru Uira Hou

He maha ngā āhuatanga matatau o ngā pūārai uira o ēnei rā e wehewehe ana i a rātou i ngā ārai ngaru. Ka whakamahia e ēnei pūnaha ngā kōpae konutea waikura i roto i te raupapa hei whakatutuki i ngā āhuatanga ngaohiko-auau tika mā te whakamahi i te hangarau varistor waikura whakarewa.

Ātete Kore-Raina

Ko te mahi nui rawa atu a ngā pū ārai uira o ēnei rā ko te ātete kore-raina. Ko te ia turuturu he iti iho i te kotahi milliampere i raro i te ngaohiko noa. Mā tēnei rere iti o te ia ka noho rite te pū ārai mō te tiaki me te kore e whakararuraru i ngā mahi a te pūnaha.

Urupare Tere mō te Ngaohiko Nui

Ka whakaitihia te ātete varistor e te kaha rawa o te ngaohiko, ka taea ai te rere o te iahiko nui ki te whenua. Ka tiakina e tēnei urupare nanohekona te nuinga o ngā raruraru hiko i mua i te taenga atu ki ngā taputapu hono. Ka whakahaerehia te aukati kia tae rā anō te ngaohiko ki te āhua noa, kātahi ka hoki aunoa ki te ātete teitei.

Ngā tikanga haumaru mō ngā āhuatanga tino kino

I ngā āhuatanga hapa nui rawa, ka tāpirihia he haumaru e ngā tikanga whakaiti pēhanga. Mā te whakaputanga hau whakahaere ka ārai i te pakaru o te pahūtanga ka pā kino ki ngā kaimahi, ki ngā taputapu rānei mēnā ka nui ake te pēhanga o roto i ngā rohe hoahoa. Mā tēnei hoahoa haumaru-kore ka taea te matapae me te whakahaere i te pakaru o te pūmau.

Te Kaha ki te Whakamarara i te Pūngao

Ko te nui o te kaha ngaru ka taea e te pūngao aukati te mimiti me te kore e pakaru, e whakawhirinaki ana ki te memeha o te kaha. Hei tu atu i ngā huihuinga ngaru maha, kua pai ake te whakamatao me te hanganga o roto o ngā pūngao aukati kaha-nui.

Mahi i roto i nga Taiao rereke

Ka pāngia te mahi a ngā tauwehenga pāmahana e te mahi a ngā pūmau i roto i ngā taiao rerekē. Ka whakaratohia e ngā pūmau kounga te tiaki pumau mai i te makariri o te Arctic ki te wera o te koraha, ahakoa te wāhi tāutanga.

Ātete ki te Parahanga o te Tāutanga o Waho

Me ātete ngā whakaurunga o waho e pāngia ana e te rehu tote, ngā tukunga ahumahi, te puehu koraha rānei ki te parahanga. Ka ātete ngā whare polymer auaha ki te whai me te mura i roto i ngā āhuatanga parahanga ka whakararu i ngā ārai tuku iho.

Hangarau i Muri i ngā Pūnaha Tiaki Uira

Te Whanaketanga o ngā Kaipupuri Uira

Ko ngā taputapu ārai uira o ēnei rā e ahu mai ana i ngā rangahau hangarau hiko me ngā rauemi mō ngā tekau tau. Nā te pai ake o ngā āhuatanga hiko-auau i ngā hoahoa silicon carbide, kua noho te hangarau varistor konutea waikura hei tikanga matua.

Nga Tikanga Hangahanga Ake

Ko te arotau i ngā āhuatanga hiko me whai rahi tika o te kōhao, ngā taumata tāpiringa, me ngā pāmahana whakamahana i roto i te hanga varistor. He piriona ngā ara tiaki whakarara o tētahi huānga hopu kotahi nā te mea he kaiwhakahaere ngaohiko moroiti ia kōhao konutea waikura.

Ngā Auahatanga Rauemi Whare

Nā te hangarau whare polymer i whakakore te pakarukaru me te taumaha o ngā ārai porcelain, ā, ka hurihia te hoahoa o ngā ārai. He ātete wai ngā whare rapa silicone, ka tukuna te wai hei ārai i te whai hiko.

Ka Whakanuia te Pakari e te Hanganga Hiri

Ka whakakorea e te hanganga hiri te urunga mai o te makuku i puta ai te pakaru o te aukati. Mā ngā matū hiri matatau ka taea te whakawhānui i te wera o ngā wāhanga o roto, ā, ka mau tonu te pumau puta noa i ngā huringa pāmahana.

Mana Kounga Kaha

Mā te mana whakahaere kounga hanga ka whakarite i te mahi o ia puranga. Hei whakatutuki i ngā paerewa o te ao, ka whakamatautauria ia pūmau, ka hurihia te huringa wera, ka whakatereterehia te pakeke.

Te Tiaki me te Aroturuki Auaha

Mā ngā taputapu tāutanga pēnei i ngā pana momotu ka taea te whakamātautau me te tiaki i te pūnaha me te kore e whakaweto. Ka whakaratohia e ngā tauira matatau ngā raraunga hopu me ngā ngaru hiko i te wā tūturu mā te aroturuki mamao.

Te Tiaki Matapae Pūoko Atamai

Mā ngā pūoko atamai ka taea te tiaki matapae e arotau ana i te wā whakakapinga me te tiaki tonu. Ka matapaehia e ēnei pūoko ngā āhuatanga mutunga-ora mā te aroturuki i te ia turuturu, te kaute ngaru, me te pāmahana o roto.

Ngā Painga Matua mō ngā Taupānga Ahumahi

Te Parenga mō te Wā Whakamutu me te Raru o ngā Taputapu

Ka tiakina e ngā taputapu ārai uira ngā pakaru kino o ngā taputapu e whakaroa ana i te kati o ngā raina whakaputa. Ka tiakina e ēnei taputapu ngā moni whiwhi mai i te hanga mā te whakaiti i te tūponotanga o ngā motuhanga ohorere.

Te roa o te oranga o nga taputapu me te iti o nga utu tiaki

Ka roa ake te ora o ngā motuka, ngā puku, me ngā pūnaha whakahaere ina puritia ngā taumahatanga ngaohiko i roto i ngā tawhā hoahoa. Ka roa ake ngā wā tiaki a ngā taputapu ārai uira, ā, ka whakaiti i ngā utu whakatikatika ohorere mā te whakaiti i te hekenga o te whakamarumaru mai i ngā pikinga ngaohiko. Ka mahi ngā taputapu ārai waikura whakarewa hou mō ngā tekau tau me te kore tiaki, he rerekē ki ngā taputapu ārai āputa e hiahia ana kia whakatikatikaina me kia whakakapia i ngā wā katoa. Mā tēnei āhuatanga ka iti te tiaki a ngā taputapu ārai puta noa i te roanga o te ora.

Ngā Painga Pūtea me te Inihuarangatia

He maha ngā wā ka whai hua te inihua i te tāutanga o te pūnaha tiaki ngaru. Nā te iti o te mōrearea o ngā kereme e pā ana ki te huarere, he maha ngā kaiinihua e whakaiti ana i ngā utu mō ngā whare he pūnaha tiaki uira whānui.

Te Hototahitanga Pūnaha me ngā Whakapainga Whai Hua Pūngao

He hototahi ngā pūārai uira ki ngā pūnaha hiko o nāianei, ā, he māmā ake te whakahou. Mā ngā whirihoranga whakairinga paerewa me ngā hononga hiko ka taea te whakauru ngāwari ki ngā tahora o nāianei me te kore he whakarerekētanga nui. Ka whakapai ake ngā pūārai uira i te whai huatanga o te pūngao mā te whakakore i ngā raruraru ngaohiko e meinga ai ngā taputapu kia mahi i waho o ngā tawhā tino pai. Ka mahi pai ngā puku auau rerekē, ngā pūtake hiko, me ētahi atu kawenga tairongo me te mana ma.

Te Herenga Pumanawa me nga Whakaaro

Te ahotea pūnaha me ngā wero taunga

Ka pāngia pea ngā pūārai uira e te nui rawa o te ngaohiko rangitahi nā ngā hapa pūnaha, ngā pānga haruru rānei. Tērā pea ka whakararuraruhia ngā pūārai uira e ngā āhuatanga i tua atu i tō rātou kaha mahi tonu, ka pakaru. Me whai hononga pai ki ētahi atu taputapu tiaki mō te raupapa mahi tika i ngā wā hapa. Tērā pea ka raru ngā mahi, ka kore rānei e tika te tiaki mēnā kāore i te pai te whakaritenga o ngā pūnaha, ka waiho ngā taputapu nui kia ngoikore i ngā wā hapa.

Te Taiao me te Whakanoho

Ka pāngia te kōwhiringa me te mahi a ngā ārai uira e ngā āhuatanga taiao. Me whai whakaaro ngā tāutanga teitei ki te iti o te mātotoru o te hau i runga i te whakamarumaru o waho. Tērā pea ka hiahiatia he whakatakotoranga teitei ake mō ngā ārai uira i ngā pāmahana tino wera. Ka pā nui te kounga o te tāutanga ki te whai huatanga o ngā ārai uira. Me tika te whenua, te ātea, me te whakamau mō te tiakitanga nui. Ka taea e te tāutanga ngoikore te whakaiti i te whai huatanga me te haumaru o ngā ārai uira.

Te Utu, te Tiaki, me te Whakakapinga

He nui te utu mō te tāuta i ngā ārai uira, inā koa i roto i ngā tāutanga nui me ngā waeine maha. Heoi, ko te tātari utu mō te huringa ora ka puta he hua pai mā te karo i te kino me te wā kore mahi. Me whakakapi wawe ngā ārai uira i runga i ngā āhuatanga o te kaihanga me te taiao o te rohe. Ahakoa ka roa ngā ārai uira mō ngā tekau tau, ko ngā āhuatanga kino, ko ngā mahi ngaru auau rānei me whakakapi wawe kia pai ai te tiaki.

Ngā Whakahōunga Pūnaha me te Whakahaere Mahi

Me arotake ngā ārai uira o nāianei i te wā e huri ana te ngaohiko o te pūnaha. Hei pupuri i ngā tawhiti tiaki me te whai huatanga, me whakakapi pea ngā ārai uira i muri i ngā huringa ngaohiko, whirihoranga pūnaha rānei.

Te Mahi a te Pūrere Ārai Uira ki ngā Mea Rerekē

Te Whanaketanga mai i ngā Kaihopu Tuku Iho ki ngā Kaihopu Hou

Nā ngā ārai pūngao āputa tuku iho i whakauru mai te tiaki ngaru. Ahakoa te iti o te utu tīmatanga, he koretake te mahi a ēnei taputapu, he nui te tiaki, ā, he iti noa te whakahaerenga o ngā ngaru. Nā tēnei i hua ake ai he otinga matatau ake. He pai ake te tiaki a ngā ārai waikura whakarewa o ēnei rā me te iti o te tiaki. Ko ēnei ārai ngaru te whiringa pai rawa atu i ēnei rā nā te mea ka taea e rātou te whakahaere i ngā taumata pūngao teitei me te mahi pono.

Ngā Here o ngā Pūrere Tiaki Tāpiri

He rerekē ngā huarahi e tiaki ai ngā parenga ngaru iti-ngaohiko i ngā hiko tairongo. Kāore e taea e ēnei taputapu te whakahaere i ngā taumata pūngao pūnaha hiko ngaohiko teitei, nō reira me whakamahi ngā ārai hei tiaki i ngā hanganga hiko matua. Ahakoa he teitei ngā ngaohiko tuku-roto o ngā ārai ngongo hau, he pai te whakahaere i ngā ngaru. Ko te tikanga, kāore pea e tiakina ngā taputapu hou, tairongo e hiahia ana ki te ngaohiko iti ake mō te haumaru. Ahakoa he whai hua ngā whakawhiti me ngā tātari wehewehe mō te whakatikatika hiko, kāore e taea e rātou te urupare tere ki ngā whakawhiti i puta mai i te uira. Ka tautokohia e rātou te tiaki ārai engari kāore e taea te whakakapi i te mahi tonu a te tiaki uira.

Te Tūranga o ngā Pūnaha UPS i roto i te Tiakitanga Hiko

He pai te tiaki a te UPS i ngā kawenga hono engari he utu nui mō ngā pūnaha hiko katoa. Ka whakaratohia e ngā ārai uira he tiakitanga puta noa i te pūnaha i te utu iti iho, e āhei ai ngā pūnaha UPS ki te arotahi ki te kounga hiko me te tārua.

Rautaki Parenga Paparanga mō te Whakapai Ake i te Pono

Mā te whakakotahitanga o ngā taputapu ārai uira me ngā hangarau tiaki āpiti, ka hangaia he pūnaha parepare paparanga e aro ana ki ngā take kounga hiko maha. Ka whakapai ake tēnei rautaki i te pono o te pūnaha me te ātete ki ngā raruraru hiko.

Ngā Taupānga Whāinga me ngā Tauira Whakamahinga Pai rawa atu

Nga Pae Ahumahi

Ko ngā ārai uira mahi pai e whakamahia ana i roto i ngā whare ahumahi nui. Me mahi tonu ngā kaihanga motuka, rongoā, me te kai kia tutuki ai ngā whāinga whakaputa. Ka whai hua ēnei whare mai i te tiakitanga ngaru whānui e ārai ana i ngā katinga utu nui e pā ana ki te uira, ā, ka pupuri tonu i te hua.

Nga Ratonga Hauora

Me whai hiko pono ngā hōhipera mō ngā taputapu hauora tino nui. Ka tiakina e ngā taputapu ārai uira ngā taputapu utu nui mō te tātaritanga, te pokanga, me te aroturuki tūroro mai i ngā raruraru hiko, ka whakapai ake i te tiaki tūroro me te pono o te ratonga hauora.

Te Pokapū Raraunga

Me pupuri tonu ngā pokapū raraunga kapua, pūtea, me ngā whakawhitiwhiti kōrero i te wā mahi kia tutuki ai ngā whakaaetanga taumata ratonga. Ka taea e ngā motuhanga e pā ana ki te uira te rere haere i roto i ngā whatunga honohono, ka pā ki ngā mano tini o ngā kaiwhakamahi, ā, ka puta he mate pūtea nui. Mā te ārai ngaru e ārai tēnei.

Nga Teihana Whakamahinga

Me kaha te tiaki i ngā teihana hiko kāinga me ngā teihana hiko arumoni i ngā wā pōuri kia mau tonu ai te pumau o te whatunga hiko. Ka āraihia e ngā ārai pūnaha tohatoha ngā motuhanga hiko a ngā kiritaki, ā, ka tiakina hoki ngā taputapu hiko.

Ngā whakaurunga pūngao hou

He maha ngā wā kei ngā wāhi e pāngia ana e te uira ngā pāmu hiko pūngao rā me ngā pāmu hau. Me whakamahi he ārai ārai hei pupuri i te hua o ēnei haumitanga ahakoa ngā āhuatanga taiao kino, hei tautoko hoki i te whakawhiti ki te pūngao pumau.

Te whakakaha hiko o te rerewē

Me tū atu ngā pūnaha hiko tereina ki te uira i roto i ngā whatunga whānui o ngā ara iahiko o runga. Mā ngā ārai uira ka mau tonu te ratonga pāhihi me te tiaki i te tuku hiko i ngā wā kino o te rangi, ka pai ake te haumaru me te pono o ngā waka a te iwi.

Opaniraa

Kei te piki haere te ngoikore o ngā pūnaha hiko hou ki ngā raruraru hiko, nō reira he mea nui ngā taputapu ārai uira. Mā te pūtaiao rauemi matatau me ngā mātāpono hangarau kua whakamātauhia i roto i ēnei taputapu ka whakaratohia he parenga pono mō ngā tono maha. Mā te mōhio ki tā rātou mahi, ngā painga, me ngā ngoikoretanga ka āwhina i te whakatinana i ngā rautaki tiaki hiko whānui. Ka urutau ngā taputapu ārai uira ki ngā wero tiaki hou me te tiaki i ngā haumitanga hanganga nui i te mea ka uaua ake, ka tairongo ake ngā pūnaha hiko.

Pātai Auau

P1: Kia pēhea te roa o te wā e mahi ai ngā ārai uira?

A: Ka roa te mau o ngā ārai uira waikura whakarewa hou mō te 20-30 tau i raro i ngā āhuatanga noa. Ka pāngia te roa o te mahi e ngā āhuatanga taiao, te auau o ngā mahi ngaru, me te kounga o te tāutanga. Mā te aroturukitanga auau ka pai ake te wā whakakapinga.

P2: Ka taea e ngā ārai uira te tiaki i ngā momo ngaru hiko katoa?

A: He whai hua ngā ārai uira ki te aukati i ngā ngaru me ngā whakawhiti hiko e puta mai ana i te uira, engari kāore pea e whakapai ake i te kounga o te hiko. He pai ake te mahi tahi me ngā taputapu tiaki ngaru mō ngā taputapu tairongo me ngā taputapu whakatikatika hiko hei whakapai ake i te kounga o te hiko.

Q3: He aha te tiaki e hiahiatia ana mō ngā taputapu ārai uira?

A: Ki te whakaritea ki ngā hangarau tawhito, he iti noa te tiaki e hiahiatia ana e ngā ārai waikura whakarewa. Ka tirohia e ngā tirotiro ā-tau mō ngā kino, te poke, me ngā hononga koretake. Ka tirohia e ngā whakamātautau hiko i ia tau torutoru ngā ia rerenga me te tiaki. Ka arotake tonu ngā ārai hou e mau ana i ngā aroturuki i te āhua.

Whakarerekētia tō Parenga Hiko me ngā Otinga Ārai Uira Xi'an Xidian

Ka taea e koe te whakawhirinaki ki a Xi'an Xidian, he kaiwhakarato pono mō ngā taputapu ārai uira , ki te hanga i ngā taputapu ārai uira kounga teitei me ētahi atu hua tiaki ngaru matatau hei pupuri i te haumaru o ngā taputapu hiko nui. Ko ā mātou taputapu kua whakatauria mō ngā papatairite ka mahi pai i ngā teitei tae atu ki te 4,000 mita, ā, ka tutuki i ngā paerewa o te ao. Ka tukuna e mātou he pūnaha haumarutanga ritenga mō ngā wheketere, ngā hōhipera, me ngā pokapū raraunga puta noa i te motu. Neke atu i te 100 ngā momo hua me ngā hangarau polymer kua patenttia ka taea ai tēnei. Kei te rite koe ki te hanga i tō whare kia haumaru ake i ngā ngaru? Tukuna he īmēra ki a serina@xaxd-electric.com , amber@xaxd-electric.com , me luna@xaxd-electric.com mō ngā tohutohu a te tohunga.

Tohutoro

1. Paerewa IEEE C62.11-2012: Paerewa IEEE mō ngā Ārai Pupuhi Whakarewa-Waikura mō ngā Porowhita Hiko AC

2. International Electrotechnical Commission IEC 60099-4: Ngā Ārai Pupuhi - Wāhanga 4: Ngā Ārai Pupuhi Waikura-Metara kāore he āputa mō ngā pūnaha AC

3. Hinrichsen, Volker. Ngā Ārai Pupuhi Whakarewa-Waikura: Ngā Kaupapa Taketake me ngā Whakamahinga. Berlin: Springer-Verlag, 2019

4. McDermott, Thomas E. Te Tiakitanga Uira mō ngā Pūnaha Hiko. IEEE Power Engineering Society, 2018

5. Greenwood, Allan. Ngā Whakawhiti Hiko i roto i ngā Pūnaha Mana: Te Ariā, Ngā Āhuatanga me Ngā Whakamahinga. New York: Wiley-IEEE Press, 2017

6. Cooray, Vernon. He Kupu Whakataki ki te Uira: Ahupūngao, Hangarau me ngā Taupānga. Dordrecht: Springer Science+Business Media, 2020