huaPic

Whaiaro-whakaora Punga-potakataka

1. Ngaohiko Whakatauranga (Ue): 250v ~ 525v, tae atu ki te 2000v.
2. Auautanga: 50/60Hz.
3. Hoahoa kiato, he pūtu whakapūmau whenua.
4. Rauemi mō te kohua: kapia PU (kapia ngohengohe).
5. He ngāwari te tāutanga me te waea.
6. Rahi iti, taumaha māmā.
7. Whakaora-ā-koe, Kore Tiaki.
  • Tukunga Tere
  • Tātari kounga
  • 24/7 Ratonga Kaihoko

Kupu Whakataki hua

Whaiaro-whakaora Punga-potakataka

Kupu Whakataki hua

Kei te rapu koe i tētahi whakatikatika mana pono i roto i tō pūnaha hiko? Ka tukuna e tā mātou Pūnga Whakaora-ā-Whaiaro-porotaka te mahi tino pai mō ngā tono ngaohiko reo-waenga me te iti. Ka whakamahia e tēnei pūnga matatau te hangarau kiriata polypropylene whakarewa me ngā āhuatanga whakaora-ā-whaiaro atamai e wehe aunoa ana i ngā hapa. Ka whiwhi koe i te mahi kore tiaki me ngā āhuatanga haumaru pai rawa atu kua whakauruhia ki roto. Ka tukuna e te hoahoa porotaka ngā rahi kiato me te hanganga mama, e māmā ai te tāutanga me te whai hua. Ahakoa kei te whakapai ake koe i ngā pūnaha o nāianei, kei te hoahoa rānei i ngā tāutanga hou, ka whakaratohia e tēnei Pūnga Whakaora-ā-Whaiaro-porotaka te pono e hiahiatia ana e tō whatunga tohatoha mana.

Me ngā ngaohiko whakatauranga mai i te 250V ki te 525V (ka taea te whakarite ki te 2000V), ka urutau tā mātou pūnga hiko ki ngā taiao ahumahi me ngā taiao arumoni. Ka whakamahia e te rauemi kohua he kapia PU hei tiaki i te taiao. Ka maioha koe ki te hoahoa pūtu whenua me ngā hononga waea ngāwari e tere ake ai te wā tāutanga.

Whakatakotoranga Hangarau

tawhā Whakapūtātanga
Ngaohiko Whakatau (Ue) 250V ~ 525V (tae atu ki te 2000V e wātea ana)
auautanga 50 / 60 Hz
Rauemi Dielectric Kiriata Polypropylene Whakarewa
Taumata Wetewete 3kV
Nga Mea Poari <0.0010 (20℃, 50Hz)
Temperature Whakahaere -20 ° C ki 50 ° C
Altitude Tae atu ki te 2000m (4000m mō ngā tauira teitei)
Te whakatairanga Resin PU (Resin Ngāwari)
Wā Te Tango Ka heke te ngaohiko ki raro i te 75V i roto i ngā meneti e 3
Housing Material Rino Pirau 1mm
Standards GB/T 12747.1&2-2004, IEC60831-1&2

Nga waahanga matua me nga painga

Hangarau Whakaora Whaiaro

Ina puta he pakaru iti, ka whakatika aunoa te kiriata whakarewa i a ia anō. Ka roa ake te ora o te mahi ki te whakataurite ki ngā pūnga hiko tuku iho.

Hoahoa Porotaka Kiato

He iti te tapuwae e penapena ana i te wāhi nui o te panera. He māmā te hanganga e whakaiti ana i te kawenga hanganga.

Te Parenga Haumaru Takitoru

He parenga ā-roto kei roto i te tinana mai i te pāmahana nui rawa, te iahiko nui rawa, me ngā āhuatanga pēhanga nui rawa. Ka wehea aunoatia ngā wāhanga pakaru e ngā fiusi ā-roto.

Te Wera Tohanga

Ka pai te whakawhiti wera o te anga rino. Mā ngā āputa wehewehe ā-roto i waenga i ngā huānga ka pai ake te mahi whakamatao, ā, ka ārai i te horapa o te hapa.

Whakahaere-Free Mahi

Ki te kore he irahiko wai, kāore he mōrearea turuturu. Kia tāutahia, ka warewarehia te tiaki o ia rā.

Hoahoa Ngaronga Iti

Ka whakaitihia te moumou pūngao e ngā rauemi kounga teitei me te hanga tika. Mā ngā hononga parahi o roto ka iti te ātete ki te pa.

Parenga taiao

Mā te tukatuka korehau me te whakakāpia kapia ka wehea katoatia ngā hau kino me te makuku. Kāore he parahanga taiao e puta mai i te hoahoa hoa-taiao.

Whakamahinga Mahi

Ka taea e tō pūnaha hiko te whai hua mai i ā mātou pūnga iahiko porotakaroa i roto i ngā āhuatanga maha:

  • Nga Tipu Hanga Ahumahi – Whakapai ake i te tauwehenga mana i roto i ngā whare he taumaha ngā kawenga mōtini
  • Nga Whare Tauhokohoko – Whakaitihia ngā utu hiko, ā, whakapai ake i te kounga o te hiko
  • Whatunga Tohatoha Hiko – Whakaitihia te ngaronga o te mana tauhohe i roto i ngā teihana hiko
  • Nga Taonga Petrochemical – Te mahi pono i roto i ngā taiao ahumahi uaua
  • Pūnaha Rerewei – Te whakatikatika i te tauwehenga mana mō te pūhiko hiko kukume
  • Nga Mahi Maina – He mahi pakari i roto i ngā āhuatanga uaua
  • Nga Whare Tiaki Wai – Te utunga mana tauhohe whai hua
  • Pokapū raraunga – Te kounga hiko pumau mō ngā taputapu nui

Kia pehea te Works te reira

Ka rongoa e te pūnga hiko porotaka te pūngao hiko i roto i te mara hiko-kore. Ina honoa ki te whirihoranga shunt puta noa i tō pūnaha hiko, ka whakaputahia he mana tauhohe ā-rohe. Ka whakatikatikahia e tēnei ngā kawenga whakauru pēnei i ngā motuka me ngā whakawhiti hiko.

He paninga whakarewa tino angiangi te kiriata polypropylene kua whakakikoruatia. Mēnā ka puta he wāhi ngoikore, ka mimiti te paparanga whakarewa huri noa i te hapa i te wera ā-rohe. Mā tēnei mahi whakakore-ā-ake ka wehea te wāhi kua pakaru i roto i ngā maikorohekona. Ka haere tonu te kiriata e toe ana ki te mahi noa.

Ka whakaiti aunoatia e ngā ātete tukunga ā-roto te ngaohiko kua rongoatia i muri i te momotu hiko. I roto i ngā meneti e toru, ka heke te ngaohiko ki ngā taumata haumaru i raro i te 75V. Ka tiakina ngā kaimahi tiaki me ngā taputapu.

Mā te tukanga whakakākahu korehau ka whakauruhia ngā huānga ki roto i te kapia kawe wera. Ka hangaia he hiri ā-haumaru hei ārai i te poke o te taiao, ā, ka whakawhiti pai hoki i te wera o roto ki te whare maitai.

Kairangi Hanga

I Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd., ka hangaia e mātou ia pūnga iahiko me te tino tika me te āta tupato. E whai ana tā mātou whare whakaputa i ngā tikanga whakahaere kounga tino pakari.

Ka tangohia e mātou he kiriata polypropylene whakarewa kounga teitei mai i ngā kaiwhakarato whaimana. Ka tukatukahia ia wāhanga pūnga hiko mā te korehau hei whakakore i ngā putunga hau me te makuku. Ka whakamahia e te whakakī kapia thermosetting ngā rauemi kua tīpakohia mō te kawe wera tino pai.

Kei roto i tā mātou pūnaha hanga he tiwhikete whakahaere kounga ISO9001. Kei a mātou anō hoki ngā tiwhikete whakahaere taiao ISO14001 me te hauora mahi OHSAS18001. E whakaatu ana tēnei i tā mātou whakapau kaha ki te kounga, ki te kawenga taiao, me te haumaru o ngā kaimahi.

Ka oti katoa ngā whakapūnga kua oti te whakamātau i mua i te tukunga. Ka manatokohia e mātou te ātete whakamahana, te tika o te whakapūnga, te tauwehenga ngaronga, me ngā mahi tiaki haumaru. Ko ngā hua anake e tutuki ana i ā mātou paerewa tino pakari ka tae atu ki tō whare.

He aha Kōwhiri Us

Awhe Hua Matawhānui

Neke atu i te 100 ngā momo hua e tukuna ana e mātou puta noa i te 9 ngā kāwai me te 34 ngā raupapa. Mai i ngā taputapu whakawhiti ki ngā whakawhiti hiko, ka whakaratohia e mātou he otinga tohatoha hiko katoa.

Hangarau Hangarau

He maha ngā tau o te wheako o tā mātou tīma hangarau ki ngā taputapu hiko reo-waenga me te hiko iti. E 863 ngā kaupapa ā-motu i whai wāhi atu mātou, ā, he maha ngā mana pateni kei a mātou.

Raukaha Whakarite

Kāore ngā hua paerewa e tutuki i ngā whakaritenga motuhake i ngā wā katoa. Ka whakaratohia e mātou he otinga kua whakaritea kia rite ki ō hiahia ngaohiko, iahiko, me te taiao.

Tuhipoka Puka Tuku

I rongonui ā mātou hua i Haina. E mahi ana mātou ki ngā kiritaki puta noa i ngā ahumahi hiko, whakarewa, hinu matū, me te rerewē.

Tautoko mo te motu

Mā tā mātou whatunga hokohoko me te ratonga ka tere te tautoko hangarau ahakoa kei hea ō kaupapa.

Tātari kounga

E tautokona ana tā mātou kupu whakaari kounga e te tiwhikete toru (ISO9001, ISO14001, OHSAS18001). E tutuki ana ngā paerewa ā-motu me te ao katoa i ngā hua katoa.

FAQ

P: He aha te roanga o te ora o ēnei pūnga hiko?

A: Mēnā he tika ngā āhuatanga whakahaere, ka mahi te Pūnga Whakaora-ā-Whaiaro mō ngā hāora neke atu i te 100,000. Ka roa ake te roa o te mahi mā te tikanga whakaora-ā-whaiaro.

Q: Ka taea e koe te whakarite i ngā whakatauranga ngaohiko?

Āe, ka taea e mātou te whakarite i te hiko tae atu ki te 2000V kia rite ki ō hiahia. Whakapā mai ki tā mātou tīma hangarau hei matapaki i ō hiahia.

P: Me pēhea te whakatau i te uara capacitance tika?

A: Ka tūtohu mātou kia whakahaerehia he tātaritanga tauwehenga mana o tō pūnaha. Ka taea e ā mātou kaihangarau te āwhina i ngā tataunga me te whiriwhiri hua.

Q: Ka mahi ēnei pūnga hiko i ngā teitei?

A: Ka taea te whakamahi i ngā tauira paerewa tae atu ki te 2000m. Kei a mātou ngā putanga teitei kua whakaritea mō te teitei 4000m+.

Q: He aha te tiaki e hiahiatia ana?

A: He iti noa te tiaki e hiahiatia ana. Ka tūtohu mātou kia tirohia te hononga i ia wā, i ia wā, kia mau hoki te hononga i te wā e kore ai e whakamahia te pūnaha.

Q: Kei te waatea nga waahanga whakakapi?

Āe, kei a mātou te rarangi o ngā wāhanga whakakapinga noa, ā, ka taea e mātou te tuku tere ina hiahiatia.

Q: Kia pehea te roa o te wā tuku mō ngā hua paerewa?

A: Ko ngā hua whirihoranga paerewa ka tukuna i roto i ngā wiki e 2-3. Ko ngā ota ritenga e hiahiatia ana he 4-6 wiki i runga i ngā whakaritenga.

Whakapā mai

Kua rite koe ki te whakapai ake i te whai huatanga o tō pūnaha hiko? Kei konei tā mātou tīma hangarau hei āwhina i a koe ki te whiriwhiri i te otinga pūnga hiko tino tika.

Īmēra: serina@xaxd-electric.com

Whakapā mai i tēnei rā tonu me ō whakaritenga hangarau me ngā taipitopito tono. Ka tukuna atu e mātou he aratohu tohunga me ngā whakatau utu whakataetae i te wā tika. Tukua a Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd. hei hoa pono māu i roto i te whakapai ake i te kounga hiko.

Tukua