Ma transformer amagetsi amkati ndi gawo lofunikira kwambiri pamakina ogawa magetsi chifukwa amasintha ma current amphamvu kwambiri kukhala ma current otsika omwe angagwiritsidwe ntchito ndi mita ndi ma switch achitetezo. Akatswiri amatha kuyang'ana momwe magetsi akuyendera popanda kukhudza mawaya amphamvu kwambiri mwachindunji chifukwa zida zoyezerazi zimagwiritsa ntchito induction yamagetsi. Malo ambiri, kuyambira mafakitale mpaka zipatala, amadalira ma transformer awa kuti asunge ntchito zawo zikuwonekera ndikusunga antchito otetezeka. Kudziwa momwe amagwirira ntchito, zomwe amafunika kuyikidwa, komanso momwe angasankhire kumathandiza magulu ogula kupanga zisankho zanzeru zomwe zimakhudza kukhazikika kwa makina ndi kasamalidwe ka mphamvu.
Kumvetsetsa Zosinthira Zamakono Zamkati
Mfundo Zofunikira Zogwirira Ntchito ndi Zigawo
Transformer yamagetsi yamkati ili ndi magawo atatu akuluakulu: kondakitala yoyamba yokhala ndi mphamvu yonse yamagetsi, flux ya magnetic core channeling, ndi ma secondary windings omwe amapereka mphamvu yocheperako ku zida. Mphamvu yoyamba imapanga mphamvu yamagetsi yomwe imayambitsa mphamvu yachiwiri yofanana kutengera chiŵerengero cha ma turns. Mapangidwe a zilonda ndi ma core amapereka kulondola kwa ndalama poyesa. Mapangidwe a mtundu wa bar amasavuta kukhazikitsa kudzera m'mabowo odutsa. Mabaibulo ogawanika ndi ma core amamangirira mawaya omwe alipo popanda kulekanitsidwa, abwino kwambiri pokonzanso.
Kugawa Molondola ndi Miyezo Yogwirira Ntchito
IEC 61869 imatanthauzira magulu olondola omwe amatchula malire a zolakwika pamlingo wosiyanasiyana. Ma transformer a kalasi 0.2 amathandizira kulipira mphamvu molondola. Ma unit a chitetezo omwe ali ndi ma rating a 5P kapena 10P amatsimikizira kuzindikira zolakwika molondola. Kugwirizana kwa ma frequency ogwiritsira ntchito—60Hz kwa machitidwe aku US, 50Hz kwa mapulojekiti apadziko lonse lapansi—kuyenera kuganiziridwa. Ma unit a transformer amkati okhala ndi ma current current awiri amagwira ma frequency onse awiri. Kulemera kwa katundu kuyenera kufanana ndi zida zolumikizidwa kuti zitsimikizire kulondola. Kusankha bwino magulu kumaletsa zolakwika zolipira kapena kusagwira ntchito bwino kwa chitetezo.
Kusiyanasiyana kwa Mapangidwe Ogwiritsa Ntchito
Ma transformer amagetsi amkati a gawo limodzi amatumikira kondakitala aliyense m'makina ogawa mawaya atatu. Mabaibulo a magawo atatu amawunika katundu wolinganizidwa m'mapangidwe ogwirizana. Malo okhala ndi magalimoto olemera amapindula ndi kuwunika kwa magawo atatu komwe kumazindikira kusalingana komwe kukuwonetsa mavuto amakina kapena magetsi. Malo osungira deta omwe amagwiritsa ntchito mapangidwe amagetsi owonjezera amafunika kuwunika kwa gawo limodzi. Epoxy resin casting imaphimba mokwanira zigawo zamkati m'mayunitsi a 35kV, kupereka chitetezo cha chinyezi ndikuchotsa mawaya amoyo omwe amawonekera, kuchepetsa chiopsezo cha arc flash panthawi yokonza.
Kukhazikitsa ndi Kusamalira Ma Transformer a M'nyumba
Zofunikira pa Kukonzekera ndi Chitetezo Pasadakhale
Magulu a mainjiniya ayenera kutsimikizira zofunikira za magetsi, ma frequency, ndi magetsi asanagule transformer yamagetsi yamkati . Mitundu ya 35kV imagwira ntchito pamakina a 50/60Hz okhala ndi ma current oyambira 20A mpaka 2500A. Zotulutsa zina ndi 1A kapena 5A—5A zomwe zimakondedwa pakugwiritsa ntchito mawaya atali omwe amachepetsa kutsika kwa magetsi. GB 20840.2-2014 ndi IEC 61869 zimatsimikizira kuvomerezedwa kwa ma code apadziko lonse lapansi. Mapangidwe ang'onoang'ono okonzedwa kuti akhale ndi malo ochepa osinthira magetsi amachepetsa mapazi a panel pomwe akusunga malo otalikirana, ndikuchepetsa nthawi yoyika ndi 30%.
Njira Zoyikira Pang'onopang'ono
Akatswiri ayenera kuonetsetsa kuti ma conductor oyambira amadutsa m'mabowo apakati popanda mawaya opindika kwambiri. Malumikizidwe achiwiri amafunika kulumikizidwa kolimba kwa ma terminal kuti atsimikizire zizindikiro za polarity kuti pakhale ubale wolondola wa gawo. Kusinthasintha kwa polarity kumayambitsa zolakwika za mita kapena kusagwira ntchito bwino kwa relay. Mphamvu yoyenera imaletsa maulumikizidwe otayirira omwe amachititsa kutentha. Njira zotsekera/kutseka zimaletsa mphamvu mwangozi. Kuyika pansi kwa terminal imodzi yachiwiri kumaletsa kusonkhanitsa kwa magetsi oopsa ngati insulation yoyamba yalephera. Musagwiritse ntchito transformer yamkati yokhala ndi dera lotseguka lachiwiri - ma spikes amagetsi amatha kuvulaza ogwira ntchito.
Ma Protocol Okonza Nthawi Zonse ndi Kuthetsa Mavuto
Kuyang'ana kowoneka bwino kumazindikira kuwonongeka kwakuthupi, kuwotcha, kapena kulowa kwa chinyezi komwe kumasonyeza kulephera kwa chisindikizo. Kujambula kutentha kumazindikira kukwera kwa kutentha komwe kumasonyeza kulumikizana kosasunthika kapena mavuto amkati musanagwere zoopsa. Kafukufuku wa chiŵerengero amayerekeza mafunde oyambira ndi achiwiri pansi pa mikhalidwe yolamulidwa. Mayeso okana kutchinjiriza pogwiritsa ntchito megohm mita amatsimikizira kuti chinyezi sichinasinthe mawonekedwe. Kuyesa pang'ono kwa kutulutsa madzi pansi pa 10pC kumapeza kuwonongeka kwa kutchinjiriza komwe kumayamba. Zolephera zomwe zimachitika nthawi zambiri zimaphatikizapo kusuntha kwa chiŵerengero kuchokera ku cores zakale ndi kuwonongeka kwa kutchinjiriza kuchokera ku kayendedwe ka kutentha. Kusamalira kolosera kumathandiza kusintha komwe kunachitika.
Zosinthira Zamakono Zamkati ndi Zakunja: Kuyerekeza Kwatsatanetsatane
Kuteteza Zachilengedwe ndi Kusiyana kwa Kapangidwe kake
Mavuto achilengedwe omwe ma transformer amkati amakumana nawo pa nthawi yogwira ntchito amadalira komwe ali. Akayikidwa m'nyumba, zinthu zimayendetsedwa, kutentha kwake kumasintha pang'ono, chinyezi sichingakhudze kwambiri, komanso chitetezo ku kuwala kwa UV. Zinthu zotetezekazi zimapangitsa kuti zikhale zotheka kumanga zinthu zopepuka komanso zokhala ndi ma casing osavuta, zomwe zimachepetsa mtengo wa zinthu. Zipangizo zakunja zimafuna nyumba zomwe sizimakhudzidwa ndi madzi ndi kuwala kwa UV, komanso kutsekedwa bwino ku mvula ndi chipale chofewa. Chitetezo cha malo otchingira—nthawi zambiri IP54 kapena kupitirira apo kuti agwiritsidwe ntchito panja—chimawonjezera kulemera ndi mtengo koma n'chofunikira m'malo omwe ali otseguka ku nyengo.
Kusankha zipangizo kumadalira zomwe malo ozungulira amafunikira. Mafomula okhazikika a epoxy amagwiritsidwa ntchito mu ma transformer amkati kuti akhale olimba komanso abwino kuyendetsa magetsi. Zowonjezera zomwe zimagwiritsidwa ntchito popanga zinthu zakunja zimateteza kuwonongeka kwa UV ndi kutentha kwambiri pa kutentha kwakukulu. Matanki akunja okhala ndi mabowo otulutsira madzi ndi njira zopumira zomwe zimaletsa kuuma kwa madzi. Poyerekeza ndi ena amkati, kusinthaku kwa kapangidwe kake kumapangitsa kuti kupanga kukhale kovuta ndipo kumakweza mtengo pa unit.
Makhalidwe Abwino ndi Zofunikira Zosamalira
Ma transformer amkati ndi akunja amapereka magulu osiyanasiyana olondola. Kulondola kwa kalasi 0.2 kumagwirizana ndi kuwerengera ndalama zamkati. Kulondola kwa kalasi 0.5 kumachitika kawirikawiri pa mayunitsi akunja chifukwa cha zovuta zachilengedwe. Ma transformer amkati amasunga kutentha kolimba komwe kumagwira ntchito m'malo ocheperako kutentha. Mayunitsi amkati nthawi zambiri amafunika kuwunika pachaka; mayunitsi akunja amafunika kufufuzidwa kawiri pachaka kuti awone ngati nyengo yawonongeka. Zipangizo zamkati zimasonkhanitsa fumbi lomwe limafuna kupukutidwa nthawi ndi nthawi; mayunitsi akunja amasonkhanitsa zinthu zodetsa zomwe zimafuna kutsukidwa ndi solvent kuti apewe kutsata kwa insulator.
Kusanthula Mtengo ndi Zosankha Zosankha
Ma transformer amkati amawononga ndalama zochepa ndi 20-30% poyerekeza ndi ma transformer akunja poyamba chifukwa cha zomangamanga zosavuta komanso zipangizo wamba. Ma transformer amkati amafuna ntchito yochepa yoyika chifukwa ndi ochepa komanso osavuta kugwiritsa ntchito. Mtengo wonse wa umwini uyenera kuganizira momwe ntchitoyo ikuyendera—kuyika transformer yamkati panja kumayambitsa kulephera msanga komwe kumawononga ndalama zambiri kuposa ndalama zoyambira. Mkhalidwe wa malo umatsimikizira kusankha: zipinda zosinthira zophimbidwa zimafuna zida zovomerezeka mkati; malo osinthira magetsi amafunikira ma substation osagwedezeka ndi nyengo. Malo osakanikirana amafunikira kufananiza mtengo woyenera wa jenereta pamalo aliwonse oyika.
Chidziwitso cha Msika ndi Buku Lotsogolera Zogula za Transformers Zamkati
Opanga Otsogola ndi Kusiyanitsa Zinthu
Pamsika wapadziko lonse lapansi, pali makampani odziwika bwino omwe amagwira ntchito zosiyanasiyana ndipo ali ndi mphamvu m'madera ena. Siemens ili ndi zinthu zosiyanasiyana, zomwe zimayang'ana kwambiri miyezo ya kapangidwe ka ku Europe komanso kuthekera kophatikiza ukadaulo wa digito. ABB ili ndi njira zogawa ndi kufalitsa, koma makina awo osinthira magetsi ndi omwe amawala kwambiri. Schneider Electric imagwira ntchito makamaka ndi ma transformer apano omwe amagwira ntchito ndi zida zowongolera mphamvu zomangira. Ndi katundu wokwaniritsa miyezo ya IEEE, General Electric ili ndi malo olimba m'misika yamagetsi ku North America.
Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. yakhala ikupanga ma transformer amagetsi amkati kwa zaka makumi atatu. Mzere wathu wazinthu umaphatikizapo mitundu yosiyanasiyana ya ma voltage, mapangidwe apakati, ndi milingo yolondola kuti ikwaniritse zosowa za mafakitale osiyanasiyana. Ma transformer amtundu wa basi mu mzere wa LMZB amagwiritsa ntchito ukadaulo wothira insulation kuti apereke magwiridwe antchito odalirika m'malo osungira magetsi, mafakitale, ndi nyumba zamabizinesi. Mapulogalamu ofufuza adziko lonse athandiza kumanga luso laukadaulo lomwe limapangitsa kuti zikhale zotheka kusintha ma ratios, zotulutsa zina, ndi mawonekedwe ozungulira kuti agwirizane ndi zosowa za polojekiti inayake.
Zofunikira Zowunikira Mafotokozedwe Aukadaulo
Ma rating a primary transformer yamkati ayenera kukhala ndi katundu woyembekezeredwa komanso kukula kwamtsogolo—transformer ya 1000A imasamalira katundu wa 600–800A wokhala ndi malire okulirapo. Kusankha kwachiwiri (1A vs 5A) kumadalira kutalika kwa chingwe; kuthamanga kwa nthawi yayitali kumathandizira ma rating a 1A kuchepetsa kutayika kwa magetsi. Ma balance a kalasi olondola amawononga ndalama poyerekeza ndi kulondola kwa muyeso: Gulu 0.2 kapena 0.5 limafunika poyesa ndalama ngakhale mtengo wake uli wokwera; Magulu a 5P kapena 10P amatumikira bwino ntchito zoteteza. Mayunitsi ophatikizana amaphatikiza ma metering ndi ma cores oteteza mu msonkhano umodzi, kusunga malo a panel.
Njira Zogulira ndi Kuwongolera Chain Chain
Njira zosiyanasiyana zopezera zinthu zimagwiritsidwa ntchito kutengera kukula ndi kutalika kwa ntchitoyo. Kulankhulana mwachindunji ndi wopanga, komwe kumalola kusintha zinthu komanso kusunga ndalama zambiri, ndikwabwino pakupanga zinthu zazikulu. Mapulojekiti ang'onoang'ono amatha kugwiritsa ntchito maukonde ogawa kuti apeze zinthu wamba mwachangu. Kuti muyeretse malo ogulitsira awa, muyenera kudziwa nthawi yodikira. Muzinthu zomwe zili m'sitolo, zimatumizidwa mkati mwa milungu ingapo, koma makonzedwe apadera amatenga milungu 8-12 kuti apangidwe.
Mukagula chinthu padziko lonse lapansi, muyenera kuganizira za kayendetsedwe ka zinthu, komwe kungasinthe mtengo wonse. Pa malonda akuluakulu, kutumiza makontena ndiyo njira yotsika mtengo kwambiri yowafikitsira komwe akupita, pomwe katundu wa pandege amalipiritsa ndalama zambiri pazofunikira mwachangu. Mayiko osiyanasiyana ali ndi misonkho yosiyanasiyana yolowera kunja ndi njira zochotsera katundu, zomwe zimapangitsa kuti zinthu zikhale zovuta kwambiri ndipo zimafuna otumiza katundu odziwa bwino ntchito. Pokambirana za nthawi yolipira, maoda a nthawi yayitali ayenera kutetezedwa ku zoopsa za kusinthasintha kwa ndalama kudzera mumitengo yokhazikika kapena mapangano ogulitsa.
Malamulo otsimikizira ubwino amateteza ogula kuti asagwere zida zosweka. Kukhala ndi zolemba zoyesera mafakitale zomwe zimakhala ndi miyeso yolondola ya chiŵerengero, kukana kutenthetsa, komanso kutulutsa pang'ono kumatipatsa poyambira kumvetsetsa momwe chinthucho chimagwirira ntchito. Ntchito zowunikira za chipani chachitatu zimawona mtundu wa njira yopangira isanatumizidwe. Izi ndizothandiza makamaka kwa ogula omwe sadziwa zambiri za woperekayo. Malamulo a chitsimikizo ayenera kuphimba mavuto onse awiri okhudza momwe chinthucho chinapangidwira komanso malonjezo a magwiridwe antchito abwino, ndi njira zomveka bwino zokonzera zinthu zomwe sizikukwaniritsa miyezo.
Ubwino ndi Zochitika Zamtsogolo za Osinthira Amakono a M'nyumba
Ubwino Waukulu Wotsogolera Kutengera
Phindu lalikulu lomwe ma transformer amkati amabweretsa ku ma circuit amagetsi ndilakuti amawapangitsa kukhala otetezeka. Mwa kusunga ma circuit oyezera kutali ndi mawaya amphamvu, zipangizozi zimateteza antchito kuti asakhudze magetsi nthawi zonse. Akatswiri amatha kufika ku ma circuit ena omwe akuyenda pamlingo wotetezeka wa magetsi, zomwe zimachepetsa kwambiri zoopsa za arc flash ndi electrocution. Mapangidwe amakono amagwiritsa ntchito epoxy resin kuti apange zigawozi kukhala zotetezeka pozitseka kwathunthu kuti zisagwirizane ndi zigawo zina mwangozi.
Mitengo yokwera ya malo osungiramo zinthu zosinthira magetsi (switchgear) ingathetsedwe ndi kasamalidwe ka malo. M'malo mogwiritsa ntchito ndalama zambiri pakusintha nyumba zodula, mapangidwe ang'onoang'ono amalola zida zambiri kuti zigwirizane ndi mapanelo omwe ali kale ndi kukula koyenera. Kuphatikiza ndi ma switch oteteza a digito ndi zoyesa zamtundu wa mphamvu kumaphatikiza ntchito zotsatirira zomwe kale zimafunikira zida zingapo zosiyana kukhala chimodzi. Izi zimapangitsa kuti mawaya akhale osavuta, zimapangitsa kuti kuthetsa mavuto kukhale kosavuta, komanso kumapangitsa kuti makinawo akhale odalirika kwambiri pochepetsa kuchuluka kwa malo olumikizirana.
Emerging Technologies ndi Innovation Directions
Kuphatikizika kwa digito ndiye njira yofunika kwambiri yomwe ikusintha momwe kapangidwe ka transformer kamakono kakusinthira. Ndi ma transformer anzeru omwe ali ndi makompyuta omangidwa mkati, simuyenera kudutsa njira iliyonse kuti muchoke pa analog kupita ku digito. Ma protocol a IEC 61850 amalola zida izi kulankhulana. Ma protocol awa ndi muyezo watsopano wa substation automation ndipo amalola kulumikizana kwa plug-and-play pakati pa opanga. Zotuluka za digito zimapangitsa kuti muyeso ukhale wolondola kwambiri ndipo zimapangitsa kuti zikhale zosavuta kulumikizana ndi ma network owongolera mafakitale ndi machitidwe oyang'anira nyumba.
Kulumikizana kwa IoT kumalola kutsatira kupitirira malire a malo okhazikika. Ma transformer omwe amalumikizidwa ku mtambo amatumiza deta ya magwiridwe antchito ku nsanja zapakati, zomwe zimakuthandizani kuwona zomwe zikuchitika m'mawebusayiti anu onse nthawi iliyonse. Kugwiritsa ntchito kusanthula kolosera pa deta iyi kuti mupeze zomwe zikuchitika pakuwonongeka komwe kukuwonetsa pamene china chake chikuwonongeka kumalola kukonza mwachangu. Mayeso akutali amachepetsa kufunikira koyendera malo, zomwe zimachepetsa ndalama zokonzera ndikufulumizitsa nthawi yomwe imatenga kuti akonze mavuto akamabuka. Kupeza kwatsopano mu sayansi yazinthu kukuwonetsa magwiridwe antchito abwino komanso moyo wautali. Zipangizo za Nanocrystalline core zimachepetsa kutayika pomwe kukula kwa kapangidwe kake kumakhala kochepa. Izi zimapangitsa mapangidwe osagwiritsa ntchito mphamvu kukhala ogwira mtima kwambiri. Mavuto azachilengedwe omwe amatha kumapeto amatha kuthetsedwa ndi ma epoxy formulations omwe amatha kubwezeretsedwanso, ndipo zinthu zokhazikika zimagwira ntchito posankha kugula. Zipangizo zolumikizira zopanda lead zikugwirizana ndi malamulo a RoHS omwe amakhudza misika yaku Europe ndipo zikugwiritsidwa ntchito kwambiri padziko lonse lapansi.
Kusintha kwa Miyezo ya Makampani ndi Kutsatira Malamulo
Magulu a miyezo nthawi zonse amasintha malamulo kuti agwirizane ndi ukadaulo watsopano ndi maphunziro achitetezo. Mndandanda wa IEC 61869 umaphatikiza miyezo yosiyanasiyana yomwe inalipo kale ya ma transformer amakono ndi amagetsi. Izi zimapangitsa kuti zikhale zosavuta kuwona ngati akutsatiridwa. Kugwirizana pakati pa miyezo ya IEC ndi IEEE kumachepetsa kusiyana kwa zofunikira zachigawo, zomwe zimapangitsa kuti kugula zinthu kuchokera kumayiko ena kukhale kosavuta. Pakusintha komwe kukubwera, malamulo achitetezo cha pa intaneti omwe amakonza zofooka mu ma transformer a digito adzawonjezedwa chifukwa kulumikizana kumapangitsa madera owukira kukhala akulu.
Malamulo okhudza chilengedwe amakhudza momwe zinthu zimapangidwira komanso zomwe zimagwiritsidwa ntchito. Malamulo okhudza kugwiritsa ntchito mphamvu amalimbikitsa mapangidwe okhala ndi kutayika kochepa, zomwe zimachepetsa mphamvu zomwe zimatayika. Malire a zinthu zoopsa amachotsa zinthu zoopsa kuchokera ku njira zopangira ndi katundu wopangidwa. Malamulo otayira zinthu kumapeto kwa moyo amakakamiza njira zopangira zochotsera zomwe zimapangitsa kuti zikhale zosavuta kusonkhanitsa ziwalo. Opanga omwe amayankha mwachangu ku izi adzakhala bwino pamene malamulo akukhwima.
Kutsiliza
Ma transformer amagetsi amkati ndi omwe amayesa magetsi omwe amagawidwa bwino komanso mosamala m'mabizinesi ndi mafakitale. Podziwa momwe amagwirira ntchito, momwe angawayikire, komanso momwe angasankhire, magulu ogula amatha kusankha zida zomwe zimakwaniritsa zosowa za makinawo pomwe akusunga ndalama zochepa momwe angathere. Pali kusiyana pakati pa mapangidwe amkati ndi akunja, magulu olondola, ndi mitundu ya nyumba zomwe ziyenera kuyesedwa mosamala malinga ndi momwe ntchitoyo imagwiritsidwira ntchito. Ukadaulo watsopano wa digito ndi kuyesetsa kukhala wosamala kwambiri ndi chilengedwe zikusintha momwe zinthu zimagwirira ntchito, zomwe zimapangitsa kuti zikhale zothandiza komanso zabwino pa moyo wawo wonse. Mgwirizano wanzeru ndi ogulitsa omwe amapereka chithandizo cha akatswiri, kuthekera kosintha, komanso kutumiza kodalirika kumathandiza kuonetsetsa kuti mapulojekiti akuyenda bwino komanso kuti zolinga zamabizinesi a nthawi yayitali zakwaniritsidwa.
FAQ
1. Ndi mlingo uti wamakono womwe ndiyenera kutchula pa ntchito yanga?
Sankhani nambala yomwe ili mkati mwa malire a 25% a mphamvu yanu yapamwamba kwambiri yolosera. Nyumba yomwe imagwiritsa ntchito 800A peak ingapindule ndi transformer yomwe imatha kugwira 1000A. Pamene katunduyo ndi wochepa, kukula kwakukulu kumapangitsa kuti makinawo asakwanire molondola, ndipo pamene katunduyo ndi wokwera, kukula kochepa kungayambitse kuti ikhale yodzaza. Kusankha kumeneku kuyenera kutengera zomwe zanenedweratu za kukula kwa katundu, popeza kusintha ma transformer sikosangalatsa ndipo kumawononga ndalama zambiri.
2. Kodi kusankha kalasi molondola kumakhudza bwanji ndalama zogwirira ntchito?
Makalasi apamwamba kwambiri amawononga ndalama zambiri poyamba, koma amapereka miyeso yolondola kwambiri. Pakuwerengera ndalama, ma transformer a Class 0.2 ndi ofunikira chifukwa amapereka ma bilu olondola komanso madandaulo ochepa amagetsi. Pazifukwa zodzitetezera, mayunitsi a Class 5P kapena 10P ndi abwino pofufuza zolakwika. Kusankha kumeneku kumayesa mtengo wogulira zida poyerekeza ndi ubwino wa miyeso yabwino pakapita nthawi.
3. Kodi ma transformer angayikidwe popanda kuletsa magetsi?
Ndi mapangidwe ogawanika pakati, ntchito ikhoza kuchitika mozungulira mawaya amoyo pamene mukutsatira malamulo okhwima achitetezo. Koma kuletsa mphamvu ya circuit kumafunikirabe kuti maulalo a terminal aletse zoopsa za arc flash. Mukayika ma transformer okhazikika a wound-core ndi bar-type, circuit yonse iyenera kuzimitsidwa. Kuletsa mphamvu nthawi zambiri kumafunika ndi malamulo achitetezo ndi mfundo za inshuwaransi, mosasamala kanthu za mtundu wa jenereta.
Gwirizanani ndi Xi'an Xikai kuti mupeze mayankho odalirika a Current Transformer Solutions
Ndi zaka 30 zakuchitikira m'mundawu komanso ukadaulo wapadera, Xi'an Xikai ndi mtsogoleri wodziwika bwino popanga ma transformer amagetsi apakati. Mndandanda wathu wa ma transformer amkati a 35kV amapangidwa ndi epoxy resin ndipo amakwaniritsa miyezo yokhazikitsidwa ndi GB 20840.2-2014 ndi IEC 61869. Ndiwolondolanso mkati mwa kalasi ya 0.2. Kutha kupanga zinthu kumatanthauza kuti ma ratios, zotuluka zina, ndi makonzedwe a ziwiya zitha kusinthidwa kuti zigwirizane ndi zosowa za polojekiti iliyonse. Ma protocol otsimikizira khalidwe, monga kuyesa kwa 100%, amaonetsetsa kuti magwiridwe antchito azikhala chimodzimodzi ndikukwaniritsa zosowa za ntchito zovuta zamakampani. Monga kampani yomwe imapanga ma transformer amagetsi amkati amisika padziko lonse lapansi, timapereka chithandizo cha akatswiri panthawi yokonzekera, kukhazikitsa, ndi kugwiritsa ntchito magawo. Lumikizanani ndi gulu lathu la mainjiniya pa serina@xaxd-electric.com , amber@xaxd-electric.com , kapena luna@xaxd-electric.com kuti mukambirane za zosowa zanu za data ndikupeza mayankho omwe akugwirizana ndi malo anu.
Zothandizira
1. International Electrotechnical Commission. "Ma Transformers a Zipangizo - Gawo 2: Zofunikira Zowonjezera pa Ma Transformers Amakono." IEC 61869-2:2012 Standard Documentation, Geneva, Switzerland.
2. Zhang, Wei ndi Liu, Xiaoming. "Kusanthula kwa Magwiridwe Antchito a Epoxy-Resin Cast Current Transformers mu Ntchito za Medium-Voltage." IEEE Transactions on Power Delivery, Vol. 34, No. 3, pp. 1245-1253, 2019.
3. Bungwe la Opanga Magetsi la Dziko Lonse. "Miyezo ya Osinthira Zida: Makhalidwe Abwino ndi Njira Zoyesera." NEMA Publication C93.1-2018, Rosslyn, Virginia.
4. Anderson, Paul M. "Kuteteza Mphamvu." Mndandanda wa Nkhani za IEEE pa Uinjiniya wa Mphamvu, Wiley-Interscience, Kope Lachinayi, tsamba 287-342, 2022.
5. Chen, David ndi Kumar, Rajesh. "Kuphatikiza kwa Smart Grid kwa Digital Current Transformers: Mavuto ndi Mwayi." Journal of Electrical Engineering & Technology, Vol. 16, No. 4, pp. 1789-1801, 2021.
6. Blackburn, J. Lewis ndi Domin, Thomas J. "Kutumiza Zinthu Mwachinsinsi: Mfundo ndi Magwiritsidwe Ntchito." CRC Press, Taylor & Francis Group, Kope Lachinayi, Mutu 6: Osinthira Zida, pp. 173-218, 2020.