Kodi mukufuna kukonza bwino mphamvu yanu ndikuchepetsa ndalama zamagetsi? Delta capacitor bank yathu imapereka njira yabwino kwambiri yolipirira mphamvu zogwira ntchito m'magetsi apakati ndi otsika. Delta capacitor bank ndi gulu lapadera la magawo atatu pomwe ma capacitor units amalumikizidwa mu mawonekedwe a triangular, kupereka magwiridwe antchito abwino poyerekeza ndi kulumikizana kwa nyenyezi. Ndi magetsi olumikizana ndi mzere omwe amagwiritsidwa ntchito pa capacitor iliyonse, kapangidwe kameneka kamapanga mphamvu zogwira ntchito katatu kuposa makina ofanana olumikizidwa ndi nyenyezi. Izi zimapangitsa delta capacitor bank yathu kukhala chisankho chabwino kwambiri cha mafakitale, nyumba zamalonda, ndi ma network ogawa omwe akufuna kukonza bwino mphamvu zamagetsi.
Yomangidwa ndi Xi'an Xidian Medium and Low Voltage Electric Co., Ltd., ma capacitor banks athu akuyimira ukadaulo wapamwamba kwambiri pakuwongolera mphamvu zamagetsi. Mudzapindula ndi zaka zambiri zaukadaulo wathu pazida zogawa mphamvu zamagetsi zapakati ndi zochepa.
luso zofunika
| chizindikiro | mfundo |
|---|---|
| Adavotera Voltage | 0.4kV - 40.5kV |
| Zotsatira pano | 630A-4000A |
| opaleshoni Voteji | Kugwira ntchito kosalekeza pa 1.1 × Un (maola 8 patsiku) |
| Kuthamanga kwa Voltage | Imapirira mpaka 2.15 × Un |
| Chotsalira cha Kutaya | ≤ 0.2 W/kVAR pa 20°C |
| kutentha osiyanasiyana | -40 ° C mpaka + 55 ° C |
| Dielectric Material | Filimu ya polypropylene yotsika mtengo |
| Kutenga pakati | Madzi opangidwa osawonongeka ndi PCB |
| Mulingo Wokwera | Kufikira 4000m pamwamba pa nyanja |
| Kugwirizana kwa Miyezo | IEC 60831-1/2, IEC 60871, IEEE Std 18 |
| Kutulutsa Nthawi | <75V mkati mwa mphindi 3 |
Main Features ndi Ubwino
Kuchuluka kwa Mphamvu Kwambiri
Makina athu amapereka mphamvu yotulutsa mphamvu yowonjezereka katatu poyerekeza ndi njira zina zolumikizidwa ndi nyenyezi pogwiritsa ntchito mphamvu zofanana. Izi zikutanthauza kuti mumalandira ndalama zambiri pamalo ochepa.
Kulekerera Zolakwa Kolimba
Kapangidwe ka kulumikizana kwa triangular kumathandizira kuti ntchito ipitirire ngakhale gawo limodzi litalephera. Dongosolo lanu limasunga mphamvu yobwezera pang'ono, zomwe zimapangitsa kuti ntchito ikhale yodalirika yomwe mungadalire.
Advanced Thermal Management
Kapangidwe ka filimu ya polypropylene yotsika mtengo kumachepetsa kutentha kwamkati. Mphamvu ya dissipation ya ≤0.2 W/kVAR imatsimikizira kukhazikika kwa nthawi yayitali komanso moyo wautali wa ntchito.
Kugwirizana kwa Harmonic
Tikaphatikizana ndi ma reactor odulidwa, mabanki athu amagwira bwino ntchito yosamalira malo okhala ndi ma harmonic ambiri omwe amagwiritsidwa ntchito m'mafakitale amakono okhala ndi ma frequency drive osinthasintha.
Njira Yosavuta
Kuchuluka kwa mphamvu kumatanthauza kuchepetsa ndalama zomwe zimagwiritsidwa ntchito popanga zinthu komanso kuchepa kwa malo oikira zinthu, zomwe zimapangitsa kuti ndalama zanu zizikhala zabwino kwambiri.
Mapulogalamu Othandiza
Malo anu angapindule ndi ukadaulo wathu m'mafakitale osiyanasiyana:
Kupanga Mafakitale : Mafakitale achitsulo, ntchito zamigodi, ndi makina olemera amagwiritsa ntchito makina athu kukonza mphamvu yoipa yomwe imabwera chifukwa cha katundu woyambitsa zinthu.
Nyumba Zamalonda : Malo ogulitsira, maofesi, ndi zipatala zimagwiritsa ntchito njira zathu zochepetsera ndalama zogulira magetsi ndikuwonjezera kukhazikika kwa magetsi.
Mapulojekiti a Zomangamanga : Njanji, machitidwe a metro, ndi ma eyapoti amadalira zida zathu kuti zipereke mphamvu zabwino komanso kuchepetsa kutayika kwa ma transmission.
Mafuta ndi Mafuta : Malo oyeretsera ndi mafakitale a mankhwala amagwiritsa ntchito makina athu kuti azilamulira mphamvu zogwirira ntchito m'malo oopsa.
Kugawa Mphamvu : Ogwiritsa ntchito magetsi ndi ma gridi amagwiritsa ntchito ukadaulo wathu kuti athandize magetsi komanso kukonza magwiridwe antchito a makina.
Mmene Ntchito
Kulumikizana kwa delta kumagwiritsa ntchito magetsi onse a mzere kupita ku mzere pa capacitor iliyonse, zomwe zimapangitsa kuti mphamvu yogwira ntchito ichuluke motsatira fomula ya Q = V² × ωC. Pamene dongosolo lanu likukumana ndi mphamvu yocheperako kuchokera ku zinthu zoyambitsa, capacitor bank imadzipangira yokha mphamvu yogwira ntchito yotsogola kuti ikwaniritse bwino kwambiri.
Dongosolo lanzeru lowongolera limayang'anira mphamvu yanu nthawi zonse ndipo limasinthasintha masitepe a capacitor ngati pakufunika kutero. Yankho lamphamvuli limakuthandizani kuti muzitha kugwira ntchito bwino nthawi zonse mukakumana ndi zovuta zosiyanasiyana komanso kupewa kubweza ndalama zambiri.
Kupanga Kwambiri
Xi'an Xidian Medium and Low Voltage Electric Co., Ltd. imagwira ntchito motsatira miyezo yokhwima yaubwino:
- ISO9001 Chitsimikizo cha Management Management System
- ISO14001 Njira Yoyang'anira Zachilengedwe
- OHSAS18001 Kuwongolera Zaumoyo ndi Chitetezo Pantchito
Malo athu opangira zinthu zamakono amagwiritsa ntchito zida zoyesera zapamwamba kuti atsimikizire kuti chipangizo chilichonse chikukwaniritsa miyezo yapadziko lonse lapansi. Chigawo chilichonse chimayendetsedwa bwino kwambiri kuchokera ku zipangizo zopangira mpaka kukayang'aniridwa komaliza.
Chifukwa Sankhani Us
Mbiri Yotsimikiziridwa
Ndi mitundu yoposa 100 ya zinthu m'mitundu 34, tadzikhazikitsa tokha ngati opereka chithandizo chophatikiza makina otsogola mumakampani ogawa magetsi.
Mayankho Okwanira
Kupatula kupanga, timapereka mayankho athunthu a dongosolo omwe akugwirizana ndi zosowa zanu, kuphatikizapo chithandizo chokhazikitsa ndi ntchito zosamalira.
luso luso
Monga otenga nawo mbali mu mapulojekiti 863 a dziko lonse, timagwiritsa ntchito nthawi zonse kafukufuku ndi chitukuko kuti tipereke mayankho aukadaulo wamakono.
Global Standards Compliance
Zogulitsa zonse zimakwaniritsa miyezo ya dziko lonse komanso yapadziko lonse lapansi, ndipo zinthu zotsogola zimadziwika kuti ndi zinthu zodziwika bwino ku China.
Customized Engineering
Gulu lathu lodziwa bwino ntchito limagwira ntchito limodzi nanu kuti lipange njira zothetsera mavuto anu apadera.
FAQ
Q: N’chifukwa chiyani ndiyenera kusankha delta m’malo mwa nyenyezi pa dongosolo langa lamagetsi otsika?
A: Pa capacitance yomweyi, kulumikizana kwa delta kumapereka 300% ya mphamvu yogwira ntchito poyerekeza ndi kulumikizana kwa nyenyezi, zomwe zimapangitsa kuti ikhale yotsika mtengo komanso yaying'ono pakugwiritsa ntchito magetsi ochepa.
Q: Kodi dongosololi limasamalira bwanji kusokonekera kwa harmonic?
A: Tikupangira mitundu yochepetsedwa yokhala ndi ma reactor otsatizana (7% kapena 14%) kuti tipewe kumveka bwino kwa harmonic ndikuteteza ku mafunde a harmonic.
Q: Chimachitika ndi chiyani ngati gawo limodzi lalephera?
Yankho: Kulumikizana kwa katatu kumalola kuti ntchito ipitirire komanso kulipidwa pang'ono. Machitidwe amakono oteteza amazindikira kulephera ndikudziwitsa ogwira ntchito yokonza.
Q: Kodi moyo uyenera kukhala wotani?
A: Munthawi yogwira ntchito bwino (kutentha <35°C, magetsi <1.1Un), makina athu apamwamba nthawi zambiri amakhala zaka 10-15 akamakonzedwa bwino.
Q: Kodi makina anu angagwire ntchito m'malo okwera kwambiri?
A: Inde, zinthu zathu zapamwamba kwambiri zimapangidwa mwapadera kuti zikwaniritse zofunikira mpaka 4000m pamwamba pa nyanja.
Lumikizanani nafe
Kodi mwakonzeka kukonza bwino mphamvu yanu? Gulu lathu laukadaulo lili pano kuti likuthandizeni kusankha njira yoyenera yogwiritsira ntchito pulogalamu yanu.
Imelo : serina@xaxd-electric.com
Lumikizanani nafe lero kuti mukambirane nafe ndikupeza momwe ukadaulo wathu wapamwamba wowongolera mphamvu ungachepetsere ndalama zomwe mumawononga ndikuwonjezera kudalirika kwa makina. Lolani ukatswiri wathu pakugawa mphamvu zamagetsi apakati ndi otsika kuti akuthandizeni kukwaniritsa magwiridwe antchito abwino kwambiri amagetsi.
tumizani kudziwitsa