Epoxy Resin Indoor Voltage Transformer: Mabhenefiti uye Dhizaini

2026-08-04 11:19:20

Muchina wemagetsi wemukati uchishandisa epoxy resin encapsulation unomiririra kufambira mberi kukuru mukuyerwa kwemagetsi netekinoroji yekudzivirira. Izvi zvishandiso zvemagetsi zvakavharwa zvizere zvinoshandura mazinga emagetsi akakwira kuita zviyero zvinoyerwa, zvakachengeteka zvekuyerwa uye maseketi ekudzivirira. Kusiyana nemayuniti akajairwa anonyudzwa mumafuta, mamodheru e epoxy resin anobvisa njodzi dzekubuda kwemvura uku achipa simba repamusoro re dielectric, zvichiita kuti zvive zvakakosha kune zviteshi zvemazuva ano, zvivakwa zvemaindasitiri, uye nzvimbo dzekutengeserana uko kuchengetedzeka, kunyatsorongeka, uye kushanda zvakanaka kwenzvimbo zvakakosha.

blog-1-1blog-1-1​​​​​​​

Kunzwisisa Epoxy Resin Indoor Voltage Transformers

Matransformer emagetsi emukati akavharirwa mu epoxy resin maturusi emagetsi akaomarara anoshandura mavoltage akakwira kuita mavoltage echipiri anogona kushandiswa nemidziyo yekuyera uye yekuchengetedza. Epoxy resin compound ine hunhu huri nani hwekudzikisa kupfuura zvinhu zvakawanda, zvichiita kuti pave nekudzivirira kwakasimba kubva pakuputsika kwemagetsi uku ichiramba yakafanana pakupisa kwakasiyana-siyana.

Core Operating Principles

Kana kutenderedza kukuru kwakabatana nehurongwa hwemagetsi ane simba guru, kunoita kuti pave nemagetsi akaenzana mu kutenderedza kwechipiri. Aya ndiwo mashandiro anoita ma transformer aya. Sechikamu che epoxy resin encapsulation process, core ne winding unit zvinogadzirwa ne vacuum. Izvi zvinobvisa chero nzvimbo dzemhepo dziri mukati dzinogona kukonzera kuburitswa kwechikamu kana kukuvara kwe corona. Nzira iyi yekugadzira zvinhu inoita kuti mashandiro e insulation arambe akafanana muhupenyu hwe transformer.

Mhando dzekuvaka uye mashandisirwo

Masimbi esimbi esilicon anoshandiswa pakugadzira gorosi anoshandiswa mukugadzirwa kwemazuva ano kuderedza kurasikirwa kwehysteresis uye kuwedzera kushanda zvakanaka kwemagnetic flux. Pamashandisirwo anoda kunyatsorongeka mumamiriro akasiyana-siyana ekutakura, ma core variants e laminated anopa kushanda kwakanakisisa. Vagadziri vakaita saXi'an Xikai vanotengesa ma transformer emagetsi emukati e35kV ane ma coil maviri echipiri anochengetedza ma metering circuits (0.2/0.5 accuracy class) uye ma protection circuits (3P/5P class) akasiyana nemagetsi. Izvi zvinomisa kupindira uye zvinoita kuti zviyero zvive zvechokwadi.

Madiro Ehunyanzvi Akakosha

Kana nyanzvi dzekutenga dzichitarisa mhinduro dze transformer dzinogona kuitika, dzinofanira kutarisisa zvinhu zvishoma zvakakosha. Maitiro ekuisa masystem akajairwa anogona kushanda ne input voltage ratings ye35kV uye output voltage ratings ye10kV. Frequency compatibility ye50/60Hz inoita kuti ishandiswe pasi rese, uye rated primary currents ye600A ne800A inosangana nezvinodiwa zvemhando dzakasiyana dzemitoro. Kusangana nezvinodiwa zveIEC 61869-1, IEC 61869-2, uye GB 20840.2-2014 kunoita kuti pave nekuchengetedzeka uye kushanda pamwe chete mumisika yepasi rose.

Mabhenefiti Makuru eEpoxy Resin Indoor Voltage Transformers

Kuwana tekinoroji chaiyo yekushandura magetsi emumba kune chekuita zvakananga nekuti mashandiro acho akavimbika sei, kuti akachengeteka sei, uye kuti anodhura zvakadii kwenguva refu. Mamodheru eEpoxy resin ane mabhenefiti anoyerwa anobatsira vatariri vezvivakwa, makambani emagetsi, uye makambani einjiniya nematambudziko akakosha.

Kuchengetedzwa Kwakawedzerwa uye Kuchengetedzwa Kwenzvimbo

Kudzivirira epoxy resin kwakachengeteka zvikuru kubva pamoto pane sarudzo dzakazadzwa nemafuta nekuti hazvibatike. Zvivako zvine michina inononoka kana zviri munzvimbo diki zvinowana zvakawanda kubva kuchinhu ichi chekuchengetedza chakavakirwa mukati. Kushaikwa kwekudzivirira mvura kunobvisa njodzi yekusvibisa nharaunda, zvichiita kuti zvive nyore kutevedzera mitemo yakaoma yezvakatipoteredza iri kugadzirwa. Epoxy resin transformers inogona kubata mapfupi emagetsi anosvika 40kA kwesekondi imwe chete. Izvi zvinovapa dziviriro yakasimba panguva yekutadza pasina kukanganisa simba rechivako.

Superior Electrical Performance

Kana simba re dielectric rakakwirira, magadzirirwo anogona kuitwa madiki pasina kukanganisa margins e insulation. Kana chikamu chekubuda kwe insulation chiri pasi pe 10pC, insulation haiputsike zvishoma nezvishoma, saka inogara kwenguva inopfuura makore makumi matatu pasi pemamiriro ekushanda akajairwa. Kugadzikana kwe epoxy resin mukupisa kunoreva kuti inoramba ichishanda zvakafanana patembiricha inotangira pa -40°C kusvika +70°C. Izvi zvinoreva kuti inogona kushandiswa munzvimbo dzine mamiriro ekunze akaoma, senge matunhu kana marenje. Nekuti mayuniti aya anogona kushanda patembiricha dzakasiyana-siyana, anogona kushandiswa nemidziyo yaXi'an Xikai yepamusoro-soro inogona kushanda kusvika pamamita zviuru zvina.

Operational Cost Advantages

Nekushandisa tekinoroji ye epoxy resin, zvinodiwa pakugadzirisa zvinodzikira zvikuru. Kusiyana nema transformer anozadzwa nemafuta anoda kuongororwa dielectric yawo uye kuchinjwa mvura nguva nenguva, ma epoxy units haadi kutarisirwa chero kupi zvako muhupenyu hwawo hwekushanda. Kudzikira kwekugadzirisa nguva dzose kunoreva kushoma kwekushanda uye kuderedzwa kwemari yevashandi. Kuvandudzika mukuchengetedza simba, kwakaitwa kuti zvikwanisike nezvinhu zvepakati zvinorasikirwa zvishoma uye magadzirirwo akanaka ekumonera, kunotungamira kudzikira kwemitengo yekushanda mushure memakumi emakore ekushandiswa. Kusanyanya kudiwa kwekuchengetedza uye kushanda zvakanaka kunoita kuti mari yese yekuva muridzi ive inokwezva zvikuru, izvo zvinoita kuti mari yepamusoro yekudyara yekutanga ive yakakosha.

Space Efficiency uye Installation Flexibility

Saizi diki, dzinenge 400mm x 300mm x 200mm dzemhando dze35kV, dzinoita kuti zvive nyore kuisa munzvimbo dzisina nzvimbo yakakwana yeswitchgear. Magadzirirwo anoiswa pamadziro anobvisa kudiwa kwemakamuri akasiyana ejenareta, izvo zvinoderedza mutengo wekuvaka nzvimbo. Dhizaini yakareruka inoita kuti zvive nyore kufamba panguva yekuisa uye inoderedza mutoro unofanirwa kuiswa pachivako. Magadzirirwo emasoketi etambo ekubatanidza kukuru anoita kuti kuiswa kuve nyore uye kumisa mapfupi asingatarisirwi anogona kukanganisa kusimba kwesystem.

Zvese izvi zvinobatsira zvinosangana zvakananga nezvinodiwa nemakambani edu atinoda. Kana mafekitori achikwanisa kuyera magetsi nemazvo, anogona kuchengetedza michina yavo ichishanda kwenguva yakareba. Kutevedza magetsi nemazvo kunochengetedza michina yemakombiyuta yakakosha munzvimbo dzedata. Zvipatara zvinova nechokwadi chekuti masisitimu ekurapa akakosha anogara aine simba rakanaka. Nekubatanidza data remagetsi renguva chaiyo nezvishandiso zvekutevera zvedhijitari, makambani emagetsi anoita kuti grid igadzikane.

Nheyo dzeKugadzira uye Zvikamu Zvikuru

Mukati me epoxy resin indoor voltage transformers zvikamu zvakaoma zveinjiniya zvinobva mumakore ekudzidza sainzi yezvinhu, dzidziso ye electromagnetic, uye nzira dzekugadzira. Kuziva misimboti iyi yekugadzira kunobatsira vatengi kuenzanisa sarudzo dzakasiyana uye kusarudza zvigadziriso zvakanakisa.

Tekinoroji yeCore uye Winding Encapsulation

Masimbi esimbi esilicon anonangidzirwa pazviyo ari pakati pe transformer anoderedza kurasikirwa kwe eddy current uye anovandudza kufamba kwe magnetic flux. Ma windings ekutanga neechipiri anogadzirwa nema conductors e copper akachena kwazvo, uye kururama kwekushanduka kunoenderana ne turn ratios chaiyo. Munzira ye vacuum-casting, liquid epoxy resin inowedzerwa patembiricha yakadzorwa uye kumanikidzwa, zvichiita kuti ive nechokwadi chekuti inotenderera zvikamu zvepakati zvese uye maronda. Izvi zvinobvisa maburi emhepo angadai akaita kuti nzvimbo dzisina kusimba dzive nyore kuti chikamu chemagetsi chitange kubuda.

Thermal Management Strategies

Guruu reEpoxy rinoita kuti kupisa kuve nyore kana tichienzanisa nemhepo, zvinoreva kuti rinoita kuti kupisa kuve nyore kubva mukati kuenda kunze. Kana richishandiswa munzvimbo dzakaoma dzemaindasitiri, dhizaini yacho inochengetedza guruva nehunyoro kunze, izvo zvinogona kuderedza mashandiro. Kusimba kwe epoxy matrix kunosimbiswa nemiedzo yekupisa inoratidza kuti inogona kutsungirira kutenderera kunodzokororwa kwekuwedzera nekudzika kunokonzerwa nekuchinja kwemutoro nekupisa kwekunze.

Kutevedzera Mipimo uye Zvinhu Zvekuchengetedza

Kutevera IEC 61869-1 neIEC 61869-2 kunoita kuti zvive nechokwadi chekuti masisitimu ekudzivirira ekunze uye maturusi ekuyera anogona kushanda pamwe chete. Kana paine zvikanganiso musystem, ma "main fuses" akavakirwa mukati ane chiyero cheXRNP1-10/0.5A anodzivirira ma "transformer windings" kubva pakukuvadza ma "overcurrents". Aya maficha ekuchengetedza akavakirwa mukati anobvisa kudiwa kwe "fusing hardware" yakawedzerwa, izvo zvinoita kuti kuiswa kuve nyore uye kunotora nzvimbo shoma pane panel. Power frequency inodzivirira kuyedzwa kwevoltage pa70kV kweminiti imwe chete inoongorora kunaka kwe "insulation" isati yabuda muplanti.

Nhungamiro dzeKuisa neKubatanidza

Kuongorora zvakatipoteredza idanho rekutanga pakuiswa kwakakodzera kuti uve nechokwadi chekuti mamiriro ari munzvimbo iyi ari mukati memiganhu yekushanda. Epoxy transformers inogona kubata tembiricha yakakwira kupfuura dzimwe sarudzo dzakawanda, asi inofanirwa kuchengetwa munzvimbo dzine mhepo yakanaka kudzivirira tembiricha kuti isakwire nekukurumidza. Kuti kuiswa kwemechanical kushande, chinongedzo chinofanira kunge chakasimba zvakakwana kuti chisakwire kudengenyeka kwenyika uye masimba emagetsi panguva yemitsetse mipfupi. Mabhuroko akasiyana eterminal anofanira kushandiswa kuchengetedza metering uye macircuit ekuchengetedza kuti asabatana netsaona pawaya yechipiri. Kushandisa cable socket primary connections dzinoshanda neZT-15/200 elbow plugs kana T-type connectors yemagetsi akakwira kunoita kuti kuiswa kuve nyore uye kunoita kuti zvive nyore kuchinja mune ramangwana.

Kuenzanisa Epoxy Resin Indoor Voltage Transformers nedzimwe mhando

Kuti usarudze tekinoroji yemagetsi inoshandura magetsi yemukati meimba, unofanirwa kuziva zvakanakira nezvayakaipira zvedhizaini yega yega. Matekinoroji ese ane zvayakanakira nezvayakaipira zvinoita kuti ive nani kana kuti iipise pazvinhu zvakasiyana.

MaModheru Akazadzwa Nemafuta Kana Epoxy Resin

Matransformer anonyudzwa mumafuta ave achishandiswa kwenguva yakareba uye akaratidzwa kuti akavimbika mukuisa kunze. Asi kuashandisa mukati kunoita kuti kuchengetedzeka pamoto kuve kwakakosha uye kunoda zvivakwa kuti kumise kudonha kwemvura. Kugadziriswa nguva dzose uye kuongororwa kwemafuta kunowedzera basa rinoda kuitwa. Epoxy resin sarudzo dzinobvisa matambudziko aya uku dzichichengetedza kushanda kwemagetsi kwakafanana. Mutengo wekuwedzera we epoxy tekinoroji unowanzo batsira munzvimbo dzine mitemo yekuchengetedza moto inoda masisitimu ekudzvinyirira anodhura emidziyo yakazara nemafuta.

Matransformer emhepo anodzivirira mhepo akaoma

Matransformer emhando yakaoma ane insulation yemhepo kana cast resin isarudzo dzakachipa dzinogona kushandiswa pamabasa asinganyanyi kuoma. Nekuti anotora nzvimbo yakawanda uye haanyanyi kurwisa kusvibiswa kwezvakatipoteredza, haagone kushandiswa munzvimbo dzakaoma dzemaindasitiri kana munzvimbo dzine nzvimbo shoma. Matransformer emagetsi emukati meEpoxy resin ane resistance iri nani yekubuditsa mvura zvishoma uye anogara kwenguva refu achidzivirira kupisa. Izvi zvinonyanya kuitika munzvimbo dzine hunyoro hwakawanda, uko hunyoro hunopinda muzvikamu zvemhando yakaoma hunoita kuti kukwegura kukurumidze.

Performance Metrics Kuenzanisa

Kune matanho akawanda ekushanda anofanira kunyatsotariswa pakuenzanisa zvinopihwa nevatengesi kubva kumakambani akaita seSiemens, ABB, Schneider, naXi'an Xikai. Kirasi yekururama ine simba rakananga pakururama kwemamita emari. Mayuniti ane kirasi yekururama ye0.2 akakodzera kushandiswa kwekuchengetedza. Kukwanisa kwakanyanya kwekutakura zvinhu kunoenderana nemiganhu yekupisa. Mitengo inomira yeshort-circuit inoita shuwa kuti sisitimu icharamba ichishanda mushure mekukanganisa. Huwandu hwekuburitsa zvishoma pasi pe10pC zvinoreva kuti chigadzirwa chakagadzirwa zvakanaka uye chichagara kwenguva yakareba. Vagadziri vanoisa chivimbo chakawanda muzvigadzirwa zvavo nekupa vimbiso dzinogara pakati pemwedzi gumi nemiviri nemakumi maviri nemana.

Mashandisirwo-Chaicho Kusarudzwa Criteria

Kune maindasitiri ane madhiraivha anochinja-chinja anokonzera kukanganiswa kweharmonic, vanoda ma transformer ane mutoro wakawanda kuti varambe vakarurama kana mamiriro acho asiri sinusoidal. Nzvimbo dzedata dzinoedza kusiya zvishoma sezvinobvira uye dzinoshanda nema digital metering systems. Nzvimbo dzemagetsi dzinotarisa pane dual-ratio configurations dzinoita kuti grid igadziriswe patsva pasina kutsiva chero mudziyo. Makambani eEPC paanotenga zvikamu zvemapurojekiti evatengi, anoyera mutengo wekutanga nemutengo wehupenyu hwese hwechigadzirwa, vachisarudza vatengesi vane rutsigiro rwakanaka rwenyanzvi uye nguva pfupi yekutungamira (isingasviki mavhiki gumi nemaviri).

Maitiro Akanakisisa Ekutenga Nekuchengetedza

Kana ukatenga ma epoxy resin indoor voltage transformers nenzira yakakodzera, haungotauri mitengo chete; unotarisawo vatengesi, woona kuti zvinodiwa zvasangana nazvo, uye woronga hupenyu hwema transformers. Maitiro aya anobatsira vanhu kudzivirira kuita zvikanganiso zvinodhura mari yakawanda uye kushandisa mukana wekuwana kukosha kwenguva refu.

Supplier Evaluation Framework

Maportfolio ezvitupa anoratidza kugona kugadzira chimwe chinhu. Kuva nechitupa chekutonga mhando yeISO 9001 kunoita kuti nzira dzekushanda dzive dzakafanana nguva dzose. Rezenisi yezvakatipoteredza yeISO 14001 inoratidza kuti wakazvipira kushandisa nzira dzakachengeteka. Hutano nekuchengetedzeka kwevashandi kunodzivirirwa nekubvumidzwa kweISO 45001. Zvitupa zvechigadzirwa zvakaita sekumaka kweCE, kunyorwa kweUL, uye kutevedzera RoHS zvinoita kuti zvive nyore kune vatongi vari mumisika yakatarwa kubvumidza chigadzirwa. Kuunganidzwa kwepfuma yepfungwa dzevatengesi, kunyanya ma patent emafomula akasiyana e epoxy kana nzira dzekumonera, zvinoratidza kuti vakafambira mberi sei uye vane hunyanzvi hwehunyanzvi.

Kusimbiswa kweChinhu cheUnyanzvi

Kuongorora zvakadzama zvirevo kunoita kuti vanhu vasavhiringidzike, izvo zvinogona kunonotsa basa racho. Kururama kwehuwandu hwemagetsi panguva yemutoro wese, kubva pa25% kusvika 100% yemutoro wepamusoro, kunovimbisa kuyerwa kwakarurama kunyangwe mamiriro ehurongwa akachinja. Tembiricha yepamusoro inogona kukwira inoongororwa neboka rayo rekupisa. Zvinhu zvakayerwa Kirasi E (120°C) neKirasi F (155°C) zvinogona kushandiswa munzvimbo dzakasiyana-siyana dzekuisa. Kuongororwa kwekukodzera kwepasi kunoita kuti zvivakwa zvive zvakachengeteka munzvimbo dzinonyanya kudengenyeka kwenyika. Izvi zvakakosha zvikuru kune nzvimbo dziri kumadokero kweUnited States.

Kugadziriswa kwezvinhu uye Kutarisira Nguva Yekutungamira

Kazhinji, zvinhu zvekatalogu zvinotumirwa mukati memavhiki masere kusvika gumi nemaviri. Magadzirirwo akagadzirwa, kune rumwe rutivi, anoda mavhiki gumi nemana kusvika gumi nematanhatu ekugadzira, kutenga, uye kugadzira. Nguva dzekutsiva zvinhu nekukurumidza dzinodzikiswa kana vatengesi vakachengeta nzvimbo dzekugovera zvinhu munzvimbo dzakavhurika. Nyaya dzekufambisa dzinosanganisira miganhu yehukuru hwezvinhu zvinokwidzwa uye huremu hwepamusoro hwezvishandiso zvekukwidza. Kutumira hakukuvadzi nzvimbo dzisina kusimba dze epoxy insulation kana paine mitemo yakajeka yekuti dzinoiswa sei.

Kuitwa kweChirongwa Chekugadzirisa

Mumamiriro ezvinhu akajairika, ma epoxy resin transformers haadi kugadziriswa, asi anofanirwa kuongororwa nguva nenguva kuti ave nechokwadi chekuti achiri kushanda zvakanaka. Gore rega rega, ongororo dze thermographic dzinotsvaga mapatani ekupisa asinganzwisisike anogona kureva kuti kubatana kwakasununguka kana kuti pane matambudziko mukati. Matsemuka kana kuchinja kweruvara pamusoro pe epoxy kunogona kuonekwa uchishandisa maikorosikopu, izvo zvinogona kureva kuti yapisa zvakanyanya kana kuti iri kukuvara nenharaunda. Kuongorora kwechipiri kwewaya kunoita kuti magumo acho ave nechokwadi chekuti hapana ngura. Kuedza mamiriro ekudzivirira kupisa makore mashanu ega ega nemidziyo yemagetsi inotsungirira frequency kwakakosha, asi zvakakosha nekuti zvinoda kumisa kushanda kwenguva pfupi uye kushandisa michina yekuyedza ine voltage yakakwira.

Dambudziko Dzakajairika Dzekuisa

Kana kuiswa kwacho kukaitwa zvisizvo, zvinogona kukonzera kushushikana kwemuchina izvo zvinogona kukonzera kutsemuka kupararira mukati me epoxy matrix. Kuti zvinhu zvipararire zvakaenzana, zvishandiso zvekusimudza zvinofanirwa kubata nzvimbo dzekusimudza dzakatarwa. Kana ma transformer akachengetwa munzvimbo dzisina kugadzikana, anosangana nekuchinja kwekushisa uye hunyoro husati hwaiswa. Kukanganisa kwekubatanidza, kunyanya kana polarity ikadzoserwa kumashure pa dual-ratio configurations, kunotungamira pakuyera zvisiri izvo zvinoita kuti kudzivirira kusavimbika. Kusadzika kwakakwana kunogona kukonzera kuvhunduka uye overvoltages yenguva pfupi dzinokurumidzisa kukwegura.

Maitiro aya ekutenga zvinhu uye kuzvichengeta zvakanaka anobatsira mapoka einjiniya kusarudza mhinduro dzakakodzera, vatariri vezvivakwa vanochengetedza mabasa achishanda zvakanaka, uye makambani emagetsi anoshandisa zvirongwa zvavo zvekutarisira midziyo zvakanyanya. Nzira iyi inoderedza mari yese yekuva muridzi uye inowedzera mukana wekushanda.

blog-1-1

mhedziso

Ma epoxy resin indoor voltage transformers itekinoroji yakagadzirwa yakaratidzwa kuva yakavimbika, yakachengeteka, uye inoshanda zvakanaka munzvimbo dzakasiyana-siyana. Kudzivirira kwavo kusingatsvedzi, kushanda kwavo kusina kugadziriswa, uye saizi diki zvinosangana nezvinodiwa nemakambani einjiniya, makambani emagetsi, uye zvivakwa zvemaindasitiri. Mamodheru e35kV ane kugona kwekuyera kirasi ye0.2/0.5 accuracy uye IEC 61869 inoenderana nezvinodiwa zvinopa masisitimu emagetsi emazuva ano shanduko chaiyo yevoltage. Kunyatsoteerera kusarudza mupi akakodzera, kuve nechokwadi chekuti specs dzakarurama, uye kutevera nzira dzakanakisisa dzekuisa zvinovimbisa basa rinobudirira uye makore ebasa risina matambudziko.

FAQ

1. Ndeipi kirasi yekunyatsojeka inofanira kutsanangurwa pamashandisirwo ekuyera mari inowanikwa?

Pakushandisa kunoda kuyerwa kwemari inoshandiswa pakuyera mari, unoda ma transformer emhando ye0.2 accuracy class anogona kuchengetedza kururama kwawo mukati me ±0.2% kubva pa25% kusvika 100%. Izvi zvinovimbisa kuti kubhadharisa kwakarurama uye kuti mitemo yese inoteverwa pazvibvumirano zvebhizinesi pakati pemagetsi nevashandisi vakuru vemaindasitiri.

2. Matransformer epoxy resin anoshanda sei munzvimbo dzakakwirira?

Matransformer emagetsi emukati akagadzirwa ne epoxy resin anoshanda nguva dzose pakakwirira kusvika pamamita chiuru pasina kurasikirwa nesimba. Pakuisa panzvimbo dzakakwirira, kunyanya pamusoro pemamita chiuru chimwe, unoda magadzirirwo emhando yeplateau ane mipata mikuru yakakomberedza kunze kuti avhare huwandu hwemhepo yakaderera. Xi'an Xikai anogadzira michina yakakosha yeplateau inogona kushanda pakukwirira kusvika pamamita chiuru chimwe.

3. Matransformer aya anogona kubatana nemasisitimu edhijitari ekugadzirisa otomatiki here?

Matransformer epoxy resin emazuva ano anogona kushanda nemidziyo yedhijitari nekuti mabudiro awo echipiri anoenderana uye anogona kubatana nemagetsi akangwara. Nekugadziriswa kwezviyero zviviri, grid inogona kugadziriswazve pasina kuchinja chero maturusi chaiwo. Munzvimbo dzinoenderana neIEC 61850, hunyanzvi hwekuburitsa hushoma hunomisa kupindirana kwemagetsi kunogona kukanganisa masaini ekutumira madhijitari.

Bata Xi'an Xikai kuti uwane zvaunoda pakushandura magetsi emumba

Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. yakagadzirira kukubatsira nezvinodiwa nesystem yako yemagetsi nekupa sarudzo dze epoxy resin indoor voltage transformer dzakatenderwa nehurumende . Mhando dze35kV dzakajairika dzatinogona kugadzira dzine 0.2/0.5 accuracy class performance, dzinoenderana neIEC 61869, uye dzakaratidzwa kuti dzinoshanda zvakavimbika munzvimbo dzemaindasitiri, dzeutility, uye dzebhizinesi. Tinonzwisisa zvinodiwa zvakanyanya zvekutenga vashandi nekuti tine matekinoroji akawanda ane patent, ISO 9001/14001/45001 certifications, uye ruzivo rwakawanda rwekushanda neState Grid systems.

Chikwata chedu chenyanzvi chinopa rutsigiro rwakakwana rweinjiniya yekushandisa, kusanganisira kubatsira nekugadzira magadzirirwo, zvidzidzo zvekubatanidza dziviriro, uye dhizaini yemagadzirirwo akagadzirwa. Nzira dzedu dzekugadzira dzinochinjika zvikuru, saka dzinogona kusangana nezvinodiwa nechero purojekiti, kungave uchida zvinhu zvekatariro yenguva dzose zvine nguva yekutungamira kwemavhiki gumi nemaviri kana michina yakasarudzika yekuisa munzvimbo dzakakwirira. Semupi anozivikanwa wevanopa ma transformer emagetsi emukati, tinotevedzera maitiro akasimba ekudzora mhando kuti tive nechokwadi chekuti yuniti yega yega inosangana nezvinodiwa zvepasi rose isati yatumirwa.

Taura nechikwata chedu chekutsigira chakazvipira pa serina@xaxd-electric.com , amber@xaxd-electric.com , kana luna@xaxd-electric.com kuti mutaure nezvematambudziko amuri kusangana nawo neapplication yenyu. Tinoda mukana wekukuratidzai kuti ma transformer emagetsi eXi'an Xikai akagadzirwa nemazvo anogona sei kuita kuti zvivakwa zvenyu zvemagetsi zvive zvakavimbika uku zvichideredza mitengo muhupenyu hwazvo.

blog-1-1

References

1. IEEE Standards Association. "Gwaro reIEEE rekushandiswa kweMatransformer eZvishandiso muSisitimu dzeMasimba." IEEE Std C57.13-2016, Institute of Electrical and Electronics Engineers, 2016.

2. Komisheni yeMagetsi yeNyika Dzepasi Pose. "Matransformer eZvishandiso—Chikamu 1: Zvinodiwa Zvakajairika." IEC 61869-1:2020, Komisheni yeMagetsi yeNyika Dzepasi Pose, Geneva, 2020.

3. Zhang, Wei naLiu, Hongming. "Zvinhu zveEpoxy Resin Composite zveAdvanced Epoxy Resin zveHigh Voltage Insulation Applications." Journal of Electrical Engineering and Technology, vol. 15, nhamba 3, 2020, mapeji 1247-1260.

4. Sangano reNyika reVagadziri veMagetsi. "Matransformer eZvishandiso: Zvinodiwa, Mashoko, uye Maitiro eKuyedza." NEMA Standards Publication TR 1-2016, Sangano reNyika reVagadziri veMagetsi, Rosslyn, 2016.

5. Chen, George naDavies, Anthony. "Kupesvedzera Kwezvikanganiso Pahunhu Hwekuputsika Kwenguva Pfupi uye Kushanda Kwenguva Refu kweDC kweLDPE neXLPE." IEEE Transactions paDielectrics neElectrical Insulation, vol. 27, nhamba 4, 2020, mapeji 1184-1192.

6. Electric Power Research Institute. "Gwaro Rekugadzirisa Transformer." EPRI Technical Report 1021870, Electric Power Research Institute, Palo Alto, 2018.

tuma