Kuiswa kwemagetsi kune simba guru pakuti chinodzivirira mheni chinodzivirira sei transformer. Isa chinodzivirira mheni pedyo nemabhandi e transformer ane voltage yepamusoro. Shandisa ma lead mapfupi, akatwasuka uye epasi, uye batanidza unit kune system yekudzika pasi isingapindi simba zvakanyanya. Chinodzivirira mheni hachimisi mheni pachayo. Pane kudaro, chinotsausa mheni uye chinochinja ma overvoltages kuita pasi kuitira kuti transformer ipinde mu voltage yakaderera. Ma lead marefu anowedzera voltage inductive uye anogona kushaisa dziviriro iyoyo simba. Muchinyorwa chino, ndinotsanangura mashandiro anoita mudziyo, pekuuisa, masarudzo awo, uye zvekutarisa usati watenga.
Mashandiro anoita Mheni padyo neTransformer
Mabhuroko eZinc Oxide Anoshanduka Kubva paInsulator kuenda kuConductor
Zvishandiso zvemazuva ano zvesimbi-oxide zvinodzivirira mheni zvinoshandisa mabhuroko ezinc oxide ane hunhu hwemagetsi-anopenya. Pamagetsi esystem akajairwa, mabhuroko anoramba achidzivirira zvakanyanya uye anobvumira chete kudonha kwemvura kudiki kuti kupfuure. Kana mheni kana switching impulse zvasvika, kudzivirira kwavo kunoderera nekukurumidza. Kuti chinodzivirira mheni chigone kutsausa simba remhepo kuenda panyika. Kana transitory yapera, mabhuroko anodzokera kumamiriro awo ekudzivirira kwepamusoro. Mukugadzira uku, hapana maburi akatevedzana, saka hapana maburi anotevedzana anogadzirwa akafanana neakagadzirwa ne gapped arresters. IEC 60099-4 inovhara metal-oxide surge arresters dzisina maburi eAC systems uye IEEE C62.11 inotsanangura zviyero zvemidziyo yakakodzera musika weUS.
Kurongeka kweVoltage yakasara uye Kudzivirira
Voltage inoonekwa pamusoro pe lightning arrester painenge ichifambisa surge current inonzi residual voltage yayo. Sisitimu ye transformer insulation inofanira kumira voltage iyi ne coordinate margin yakakodzera. Mainjiniya vanoenzanisa residual voltage ye arrester ne transformer's basic insulation level (BIL), iyo inonziwo lightning impulse yayo inomira level. IEC 60071-2 inopa gwara pamusoro pe insulation coordinate uye kushandiswa kwemidziyo yekudzivirira. Voltage yakaderera ye residual inowanzopa protection margin yakawanda, asi arrester inofanirawo kuva ne energy-handling capability yakakwana uye thermal stability. Arrester ine residual level shoma yekudzivirira asi isina simba rakawanda inogona kukundikana kana iine surge duty yakadzokororwa kana yakanyanya. Nekuda kwechikonzero ichi, protection level uye energy capacity zvinofanira kuongororwa pamwe chete pa datasheet.
Sei Kureba Kwemutobvu Nekudzika Kwepasi Zvichichinja Mugumisiro
Voltage inosvika kutransformer inokanganiswa nevoltage yasara yelightning arrester pamwe neinductance yeleads dzakabatana. Kondakita yega yega inobatsira inductance. Munguva yekukurumidza kupinza, voltage iyi inductive inogona kunge yakakura. Saka lead refu kana lead yepasi inowedzera voltage stress inonzwiwa netransformer bushing uye insulation. Voltage inobuda inogona kukura nekuda kwekubatana kwegrounding yakasimba. IEEE C62.22 inopa mazano ekushandisa kune metal-oxide surge arresters, ichisimbisa kuiswa kwakakodzera pedyo nemidziyo inofanira kuchengetedzwa. Arrester, kana yakaiswa zvakanaka neconnections pfupi dzakananga, ichapa dziviriro yakakura kupfuura michina ine leads refu zvisina kufanira.
Kwaungaisa Lightning Arrester paTransformer
Gomo Pedyo Nemabushing Ane Voltage Yakawanda
Nzvimbo yaunoda padivi pemutsetse iri pedyo nemabhazi emagetsi ane simba repamusoro etransformer. Chinovhara mheni chematransformer ane matanda chinowanzoiswa paruoko rumwe chete kana bracket pedyo nebhazi. Munzvimbo inogadziriswa mheni inowanzoiswa pedyo netransformer uye inosungirirwa zvakananga kugrounding system. Kusapinza kwelead kunoreva kuwedzera kwemagetsi mashoma sezvo nzira yemagetsi iri pfupi kubva paphase conductor kuenda kulightning arrester kuenda kutransformer bushing kuenda pasi. Paunenge uchiongorora marongerwo, usangoyera daro riri pakati pearrester nebushing chete, asiwo nzira yese yeconductor kubva paphase connection kuburikidza nearrester kuenda pasi.
Kuchinja kweCable, Rutivi rweVoltage Yakaderera, uye Kusapindirana
Kana matransformer akabatana nerubatsiro rwetambo, izvi zvinofanira kufungwa nezvazvo. Kana tambo yepamusoro yakabatana netambo yepasi pevhu, ma impulses anoratidzwa anogona kuitika nekuda kwemafungu ekufamba uye shanduko dze impedance, izvo zvinogona kudiwa chibatiso chemheni pamucheto wetambo. Mune mamwe mamiriro ezvinhu, mamwe ma arresters anogonawo kukodzera padivi remagetsi mashoma kana kuti neutral, zvichienderana nedhizaini yetransformer uye grounding configuration. Hapana gwara rakazara rekuisa ma transformer emhando yakaoma, ma transformer emukati, ma autotransformers, uye ma mixed overhead-cable networks. Kushandiswa kwega kwega kunofanirwa kuongororwa zvichienderana nezvinodiwa zveutility uye kudzidza kwe insulation coordination vasati vapedzisa kuverenga zvinhu.
Mitemo yeMagadzirirwo eVaridzi, Kubvisa Mari, uye Kuisa Ruzhowa
Kune mitemo yakati wandei yekuronga inofanira kutevedzerwa kana waisa zvinhu zvakagadzirwa zvakanaka. Dzivisa marobho uye kukotama kwakasimba mukubatanidza ma phase. Chengeta ma phase ne grounding leads ari mapfupi uye akatwasuka sezvinobvira. Batanidza lightning arrester ne transformer tank kana grounding point yakakodzera, uye batanidza grounding point iyoyo kune station grounding system. Chengetedza nzvimbo dzinodiwa kubva mu ground structures ne advance phases. Nekuti impulse current inogona kukonzera voltage muma conductor ari pedyo, chengetedza arrester grounding conductor kure ne sensitive control uye measurement wiring kana zvichibvira. Ita shuwa kuti ma joints ese akachena uye akasimba uye kuti conductor yega yega yakakura zvakanaka kuti ishandiswe. Kuora kana connection isina kusimba kunogona kuwedzera resistance uye kuderedza kushanda kwenzira yekudzivirira.
Kusarudza Rudzi Rwakakodzera rweMheni uye Kuyera
Okisijeni yesimbi, Silicon Carbide, uye Kirasi yeDuty
Masisitimu matsva ndeemhando yesimbi-oxide lightning arrester iyo inopa mhinduro nekukurumidza, kudonha kwemvura kwakaderera pamagetsi ekushanda akajairwa uye haadi kugadzika kwakafanana kwekutevera-current sezvakaita mhando dzekare dzakaganhurirwa. Mamwe magadzirirwo ekare achiri kushandisa silicon-carbide arresters ane maburi. Aya mayuniti anofanira kuongororwa vasati vasarudza kuchengetedza kana kutsiva. Distribution-class arresters anogona kushandiswa pamatransformer ari pamapango kana mapedhi nepo station-class arresters anowanzo shandiswa pakuisa substation hombe. Zvinhu zvekugara zvine basawo. Polymer housings dzakareruka uye dzinoramba kukuvara, nepo porcelain housings dzichiri kushandiswa mune mamwe maapplication ekushandisa. Arrester yakasarudzwa inofanira kukodzera system voltage, exposure, kukosha kwemidziyo uye duty class inodiwa.
Yakayerwa Voltage, MCOV/Uc, uye BIL
Usangotanga nemagetsi emagetsi esystem chete. Kutanga tarisa voltage yepamusoro yekushanda kwesystem, frequency, neutral grounding technique uye overvoltage yenguva pfupi inofungidzirwa. Wobva wasarudza voltage yakakodzera uye voltage yepamusoro yekushanda inoramba ichienderera mberi (MCOV, kana Uc muIEC nomenclature). Ma parameter acho anofanira kunge akaita zvekuti arrester inogona kusiiwa yakabatana zvachose nesystem pasina kushushikana kwakanyanya kwekupisa. Tevere, enzanisa level yelightning impulse standby kana BIL yetransformer ne arrester's discharge current uye residual voltage. Mazano ekusarudza arrester uye mashandisirwo aanopiwa muIEC 60099-5. Iyi rating inogona kuchinjwa kana grounding configuration ikachinjwa. Semuenzaniso, kana system yakasimbiswa zvakasimba uye yozochinjwa kuita system isina kuvharwa.
Kureba, Kureba, uye Kuvhara Hunyoro
Zvinhu zvakasiyana-siyana zvakatipoteredza zvine basa guru pakusarudzwa kwezvinodzivirira mvura zvakanyanya. IEC 60099-4 inoronga maparamita ebasa mumamiriro ezvinhu akajairwa ekuisa. Kuisa nzvimbo dzakakwirira kunoda kutariswa zvakanyanya pakuisa zvinhu zviri kunze uye nzvimbo dzakabviswa mvura. Kusvibiswa kunogona kuderedza kushanda kwekuisa zvinhu zviri kunze. Nzvimbo dzemahombekombe, maindasitiri neguruva dzinogona kuda daro refu rekufamba. IEC 60815-1 inopa gwara rekusarudza zvinodzivirira mvura kuti isasvibiswe. Hunyoro, kutakurwa kwemvura mugungwa uye kuratidzwa kwekunze kwenguva refu zvinowedzerawo kumanikidzwa pazvisimbiso zvemba. Midziyo yayo yemhando yeplate inogona kushandiswa pakukwirira kwemamita 4,000, Xi'an Xikai akadaro. Tarisa kukwirira chaiko, mwero wekusvibiswa, tembiricha uye nzvimbo yekuisirwa usati wasarudza chinodzivirira mheni panzvimbo yakati.
Zvikanganiso zveKuisa, Kuedza, uye Kugadzirisa
Zvikanganiso Zvinoderedza Dziviriro
Matambudziko mazhinji ekudzivirira anobva pakuiswa pachako kwete kubva kune arrester. Matambudziko akajairika anosanganisira mitsetse yakareba kana yepasi, kubatana kwepasi kwakasimba, maconductor asina saizi yakakodzera, kubatana kusina kunaka uye nzvimbo dzisina kuchena. Kukanganisa kwekusarudza kunogonawo kukonzerwa nekuti MCOV yakaderera zvakanyanya, voltage yakayerwa haienderane nehurongwa hwepasi kana daro rekuchera risina kukodzera huwandu hwekusvibiswa. Kupinda kwehunyoro, kureba, kusvibiswa kweUV uye rutsigiro rusina kunaka rwemakanika zvinofanirawo kugadziriswa. Matambudziko mazhinji aya anogona kuwanikwa mukudzidza kwakanyatsorongeka usati waisa uye akaoma zvikuru kugadzirisa mushure mekuiisa.
Chinosunga Mheni Hachisi Chimuti Chemheni
Sisitimu yekudzivirira mheni nechinhu chinodzivisa kukwira kwemhepo (surge arter) zvinoita mabasa akasiyana. Kana mheni ikarova chivako kana chivakwa, chiteshi chemhepo, chinowanzonzi mwenje wemheni, chinodzivisa kudonha kwemhepo uye chinotakura magetsi kuenda pasi kuburikidza neconductor chaiyo. Chinodzivirira mheni chinodzivirira michina yemagetsi kubva pakupfuura kwemhepo kunofamba nesystem yemagetsi. Masisitimu ese ari maviri anogona kushandiswa pamwe chete uye anofanira kubatanidzwa kune system yakagadzirwa zvakanaka yekudzika. Chiteshi chemagetsi chinogona kunge chiine sisitimu yekudzivirira mheni yekunze inoshanda ukuwo chichiri kuda kuti chinodzivirira mheni patransformer kuti chidzivise voltage inofambiswa paterminal yemidziyo.
Kuongorora uye Kutarisa Mamiriro Ezvinhu
Kuongorora nguva dzose kunogona kuratidza kuora kwemagetsi kusati kwaitika. Tarisa dzimba kuti dziwane ngura here, mitswe, nzira, kusvibiswa uye zvimwe zvakaora mumuviri. Wobva watarisa nameplate, kuenderera mberi kwegrounding uye terminal connections. Kutarisa kumwe kunogona kusanganisira kuyerwa kwe leakage current, kuyerwa kwe resistive current, kuongororwa kwe insulation uye thermal imaging zvichienderana nekurudziro yemugadziri uye kukosha kwekuisa. Kutarisa mamiriro ezvinhu. Zuva rakatarwa rekutsiva harisi iro sarudzo yakanakisa. Data kubva mumafambiro angave ane ruzivo rwakawanda. Tsvaga zviratidzo zve leakage current yakawedzera, nzvimbo dzinotyisa dzisina kujairika, zviratidzo zve flashover kana humbowo hwekushanda kwekudzvinyirirwa. Chinongedzo chemhando yekutaurirana JCQ-3 (YC)10/800D chakagadzirwa naXi'an Xikai chinokwanisa kutarisa huwandu hwekubuda kwemagetsi kubva pa0 kusvika 9999 uye kutumira data kuburikidza neRS485 neModbus-RTU kuti iongorore kure.
Gwaro reKutenga: Sarudzo dzeKubata Mheni dzeXi'an Xikai
Zvaunofanira Kuisa muRFQ yako
RFQ yakanyatsotsanangurwa inogona kubatsira kukurumidzisa maitiro emutengo uye kuderedza mikana yekuwana modhi isina kukodzera. Ipa voltage yesystem, transformer rating, transformer BIL, grounding configuration, nominal discharge current, MCOV kana Uc, uye simba rinodiwa. Kukwidziridzwa kwenzvimbo, huwandu hwekusvibiswa, rudzi rweimba, mounting configuration, zvinodiwa paterminal, nezvimwewo. Kune mapurojekiti munyika dzakasiyana, mamiriro emagetsi nemamiriro ezvakatipoteredza zvinogona kusiyana zvakanyanya. Saka, pepa reruzivo rwehunyanzvi rakasiyana paprojekiti yega yega inzira yekuchengetedza ruzivo rwacho rwakafanana. Usangoenzanisa mitengo yemayuniti chete. Tarisa zvakawanikwa pabvunzo, ruzivo rwehupenyu hwebasa, zvishandiso zvinodiwa, zvinodiwa pakufambisa, mitemo yewaranti, nezvimwe zvinoshandiswa paprojekiti. Bvunza mhedzisiro yebvunzo yemodhi chaiyo inoratidza kuenderana nezvinodiwa zveIEC 60099-4.
Zvinhu zvePolymer Lightning Arrester
Heano zvinhu zvikuru zvinonyorwa naXi'an Xikai nezvechinhu chinomisa mheni chine polymer:
- Dzimba dzepolymer dzakavharirwa: Xi'an Xikai anoti inoshandisa chimiro chekuvhara chine matanho matatu kuderedza njodzi yekupinda kwehunyoro, izvo zvinonyanya kukosha munzvimbo dzine hunyoro uye panguva yekufambisa ngarava kure. Dzimba dzepolymer dzinotsigirawo kupisa uye dzinobatsira kuderedza kushushikana kwekupisa. Nekuti kupinda kwehunyoro kunogona kukonzera kudzikira kwemubati, mashandiro ekuvhara anofanira kuongororwa panguva yekuongorora chigadzirwa.
- Kubuda kwemvura kushoma uye hupenyu hurefu: Xi'an Xikai inotaura kuti zvigadzirwa zvayo zvine hupenyu hwebasa hwemakore anopfuura makumi maviri nemashanu uye kudonha kwemvura kushoma pasi pemamiriro ekushanda akajairwa. Kambani iyi inotaurawo kuti kuyedzwa kwayo kwemagetsi ane simba guru kunofukidza mazinga emhepo anosvika 650 kV uye kuti zvinhu zve zinc oxide zvine purity yakakwira zvinogona kuteverwa nematanho ekudzivirira.
- Masisitimu emhando yepamusoro uye sarudzo: Fekitori iyi ine chitupa cheISO 9001, ISO 14001, uye ISO 45001, uye Xi'an Xikai anoti ine mapatenti anopfuura makumi maviri ane chekuita netekinoroji yesimbi-oxide arrester yakagadzirwa nepolymer. Mabasa ekutarisa eIoT anogona kuwedzerwa kumamodheru akasarudzwa kuti atarise zviitiko zvekuburitswa kwechinhu uye mamiriro emidziyo.
Sarudzo Yakazara Yakaputirwa yeCompact Switchgear
Xi'an Xikai inopawo chinodzivirira mwenje chesimbi-oxide chakagadzirwa nesimbi chakaputirwa zvakakwana, chinochengetedza michina midiki. Muchimiro ichi, tambo ine simba guru inobuda kubva kumusoro uye inosanganiswa nepakati pechinodzivirira nharaunda kuti igadzire mubatanidzwa mudiki. Kuvakwa kwakavharwa kunobatsira kudzivirira zvikamu zvemukati kubva pakukanganiswa nezvakatipoteredza uye kunogona kuderedza nzvimbo inodiwa yekuisa pakati pezvikamu uye pakati pezvikamu nepasi. Nzvimbo yekubuditsa tambo inogonawo kubatsira pakureba kunodiwa, izvo zvinogona kubatsira munzvimbo dzakasvibiswa kana dzakakwirira. Kune maodha makuru, Xi'an Xikai anotaura nguva yekutungamira yemavhiki matanhatu kusvika masere uye anopa rutsigiro rwehunyanzvi maawa makumi maviri nemana pazuva, mazuva manomwe pasvondo, uye rubatsiro rwekuisa panzvimbo. Pakutumira kubvunza, ipa munhu wekuonana naye anoshanda uye nhamba yekubata kuitira kuti timu yehunyanzvi igone kusimbisa ruzivo rweprojekiti uye kuronga kuteverwa nenguva.

mhedziso
Huwandu hwemagetsi akawandisa anosvika pa transformer hunoenderana zvikuru nenzvimbo yekuisa uye marongerwo ekubatanidza. Chinodzivirira mheni chesimbi-oxide chinobvisa mheni uye chinoshandura ma impulses kuenda pasi, zvichideredza kushushikana kwemagetsi pa transformer inoputira. Kushanda kwayo kunoenderana nemagetsi akasara, kureba kwe lead, kunaka kwegrounding, uye kubatana kwe insulation yese. Kuisa arrester pedyo ne HV bushings uye kushandisa short, straight phase uye grounding connections kunobatsira kuderedza kuwedzera inductive voltage.
Sarudzo yacho inofanira kufunga nezveMCOV kana Uc, voltage yakayerwa, transformer BIL, kirasi yebasa rekubata, kureba, huwandu hwekusvibiswa, uye daro rekukwira. Kukundikana kwakawanda kunokonzerwa nematambudziko ekuisa akadai sematambo marefu, kubatana kwakasununguka, kusakwana kwepasi, kana nzvimbo dzisina kujeka. Chinodzivirira mheni hachigone kutsiva sisitimu yekudzivirira mheni yekunze kana sisitimu yakagadzirwa zvakanaka yekudzika. Kuongorora nguva dzose uye mamiriro ezvinhu zvinogona kubatsira kuona kukwegura zvisati zvakonzera kudzimwa. Pakutenga, RFQ yakazara uye magwaro ekuyedza emhando dzakasiyana anobvumira vatengi kuenzanisa mari yese yepurojekiti uye kukodzera kwehunyanzvi pane kuvimba nemutengo weyuniti chete.
FAQ
1. Ndingaisa kupi chinhu chinodzivisa mheni patransformer?
Isa parutivi rwemutsetse pedyo neHV bushing yetransformer. Shandisa mapfupi, akatwasuka uye akabatana pasi, uye batanidza arrester zvakananga kune system yakagadzirwa zvakanaka yekudzika pasi.
2. Musiyano uripo pakati peMCOV nevoltage yakayerwa ndeupi?
MCOV, kana kuti Uc, ndiyo voltage yepamusoro-soro inoshanda inoenderera mberi iyo arrester yakagadzirirwa kugara yakasimba nguva dzose. Rated voltage imhando yakasiyana ye arrester rating inoshandiswa pamwe chete nezvinodiwa zve temporal-overvoltage uye duty-test. Makoshero ese ari maviri anofanira kusarudzwa zvichienderana nesystem voltage, grounding method, uye mamiriro ekushanda anotarisirwa.
3. Chinomisa mheni chinogona kutsiva tsvimbo yemheni here?
Kwete. Tsvimbo yemheni kana sisitimu yemhepo inovhara mheni zvakananga pazvivako, ukuwo chinodzivirira mheni chinoderedza mavhiri emagetsi anodarika mwero pamidziyo yemagetsi. Masisitimu maviri aya anogona kushanda pamwe chete sechikamu chesystem yakagadzirwa zvakanaka yekudzivirira mheni.
4. Ndinofanira kutsiva riini chinhu chinodzivisa mheni?
Kutsiva kunofanira kuenderana nemamiriro ayo uye mashandisirwo ayo kwete pazuva rimwe chete rakatarwa. Kuwedzera kwemvura inobuda, nzvimbo dzinotyisa dzisina kujairika, zviratidzo zvekubhururuka, kukuvara kwemba, kana humbowo hwekushanda kwekudzvinyirirwa kunogona kuratidza kuora uye kunofanira kukonzera kuongororwa kwakawedzerwa kana kuongororwa kwekutsiva.
Kumbira Kurudziro yeLightning Arrester Kubva kuna Xi'an Xikai
Mhoroi, Xi'an Xikai. Ndapota nditumirei voltage yenyu yesystem, transformer rating, BIL, nzira yekudzika, urefu hwenzvimbo, huwandu hunodiwa, uye nhamba yekubata. Ndichashandisa ruzivo urwu kubatsira kuona chinodzivirira mheni chinoenderana nezvinodiwa neprojekiti yenyu. Xi'an Xikai inogadzira zvinodzivirira mheni uye inopa datasheets yezvigadzirwa, rutsigiro rwehunyanzvi, uye rubatsiro rwekutumira kunze kwenyika. Ndapota taurai serina@xaxd-electric.com , amber@xaxd-electric.com , kana luna@xaxd-electric.com neruzivo rweprojekiti yenyu. Mumiriri wehunyanzvi anogona kuongorora zvinodiwa uye kukurudzira magadzirirwo akakodzera. Kuti udzidze zvakawanda nezvezvigadzirwa zveXi'an Xikai, shanyira xaxd-electric.com.

References
1. IEC 60099-4: Zvinodzivirira Kubuda Kwemvura - Zvinodzivirira Kubuda Kwemvura Nesimbi-Oxide Zvisina Mapoinzi eAC Systems, 2014
2. IEC 60099-5: Zvinodzivirira Kukwira Kweropa - Mazano Ekusarudza Nekushandisa, 2018
3. IEEE C62.11: Standard yeMetal-Oxide Surge Arresters yeAC Power Circuits (>1 kV), 2020
4. IEEE C62.22: Gwaro reKushandiswa kweMetal-Oxide Surge Arresters kune Alternating-Current Systems, 2009
5. IEC 60071-2: Kubatanidzwa kweInsulation - Gwaro reKushandisa, 2018
6. IEC 60815-1: Kusarudzwa uye Kuyera kweHigh-Voltage Insulators Yakagadzirirwa Kushandiswa Mumamiriro Akasvibiswa - Tsananguro, Ruzivo uye Nheyo Dzakajairika, 2008