Sei Transformer yeMagetsi Inonyudzwa muOiri Inoshandiswa paMambure Ane Mutoro Wakawanda?

2026-08-07 16:49:16

Transformer inonyudzwa muOiri inova sarudzo inofarirwa kana zvivakwa zvemaindasitiri, magridi emagetsi, kana nzvimbo dzesimba rinodzokororwa dzichida kupa magetsi zvakavimbika dzichibata magetsi akawanda. Matransformer aya anoshandisa zvinhu zviviri zvikuru zvemafuta emineral—kudzivirira kupisa kwakanyanya uye kupisa kwakanyanya—kubata mashandiro emagetsi ane simba guru uku achichengetedza kugadzikana uye kushanda zvakanaka. Masisitimu akavakirwa pamafuta anonwisa uye anotamisa kupisa zviri nani pane anotonhodzwa nemhepo, saka haaputsike kana akawandisa kwenguva yakareba. Nekuda kwekubatsira uku kwekugadzira, matransformer emagetsi anonyudzwa muoiri ndiwo anonyanya kushandiswa mumafekitori, ma substations, uye mapurazi ezuva.

blog-1-1blog-1-1​​​​​​​

Kunzwisisa Matransformer Emagetsi Anonyudzwa Mumafuta

Maumbirwo Epfungwa Nemitemo Yekushanda

Ine magnetic core yakagadzirwa nesimbi yesilicon inotarisa zviyo uye simbi yemhangura kana yealuminium yakaipoteredza. magnetic core inonyudzwa mumafuta. Mutangi rakafukidzwa, zvikamu izvi zvinoshambidzwa nemafuta emineral akacheneswa kana fluid ye synthetic ester. Oiri iyi ine mabasa maviri akakosha ekuita: inochengetedza magetsi kuti asafambe pakati pemawindings nekushanda se dielectric, uye inotonhodza zvikamu nekutora kupisa kunoitwa kana voltage ikachinja. Pane voltage musecondary winding kana magetsi achifamba nepakati pemawining makuru. Izvi zvinokonzerwa nemagnetic flux. Oiri inofamba-famba nenzira yechisikigo kuburikidza ne convection kana nerubatsiro rwe external radiators. Izvi zvinobvisa kupisa kubva kumawindings kuenda kumadziro etangi, uko kunobuda mumhepo.

Magadzirirwo emazuva ano anoshandisa zvikamu zvetekinoroji yepamusoro senge maswichi epombi anochinja otomatiki voltage inobuda kana kudiwa kuchichinja. Silica gel breathers inochengetedza mvura asi ichiri kurega mafuta achikura uye achidzikira sezvo tembiricha ichichinja. Ma-high-voltage link anotungamirirwa zvakachengeteka nemadziro etangi nemabhandi, ayo ari mabuffers akasarudzika. Dhizaini iyi yakabatana inoita sisitimu yakakwana inogona kubata manyuko emagetsi kubva pa10kV kusvika ku110kV. Izvi zvinoita kuti ma transformer aya abatsire pakutumira nekuparadzira.

Kugoverwa Kunopesana Nesimba reTransformer

Zvichienderana nemashandisirwo adzo, tinokamura maTransformer anonyudzwa muOiri kuita mapoka maviri makuru. Matransformer anogovera anowanzova nesimba riri pakati pe30kVA ne2500kVA. Anodzikisa voltage yepakati (6kV kusvika 35kV) kusvika padanho rinogona kushandiswa muzvipatara, zvivakwa zvemaindasitiri, nenzvimbo dzekugara. Hudiki hwavo uye mitengo yakaderera zvinoita kuti zvive zvakanaka pakupa simba munzvimbo dzakatarwa.

Kune rumwe rutivi, ma transformer emagetsi anobata zvinhu kubva pa5MVA kusvika ku50MVA muzviteshi zvinobatanidza ma network ekutumira magetsi kune ma grid mumaguta kana mafekitori. Aya mayuniti makuru ane masisitimu ekutonhodza ari nani, anowanzo sanganisira mafeni anomanikidzwa kana mapombi emafuta ekubvisa kupisa kwakawanda kunogadzirwa pavanenge vachishanda nesimba. S9 neS13 series mienzaniso yakanaka yerudzi urwu rwechip nekuti magadzirirwo avo epakati akagadziridzwa anoderedza kurasikirwa kwemutoro nekusvika 30% zvichienzaniswa nemamodheru ekare eS7. Kuziva mutsauko uyu kunobatsira matimu anotenga kuenzanisa nemazvo ma specs emidziyo nemazinga emagetsi uye mapatani emutoro enetwork yavo.

Mabhenefiti ekushandisa maTransformer anonyudzwa mumafuta muHigh Load Networks

Superior Thermal Management

Manetwork anopisa zvakanyanya ane vashandisi vakawanda anogona kukanganisa dziviriro uye kupfupisa hupenyu hwemidziyo. Oiri iri nani ka20 pakupinza kupisa kupfuura mhepo, saka kupisa kunogona kufamba nekukurumidza kubva kumawindings kuenda kunzvimbo dzinotonhorera. Iyi ficha inobatsira zvikuru kana paine kuwanda kwemagetsi—mayuniti edu emhando yepamusoro anogona kubata 150% yesimba rawo kwemaawa maviri, izvo zvisingagone kuitwa nematransformer akaoma. Iyi tembiricha inochengetedza michina inononoka kuti isadzima kana paine emergency munguva dzezhizha kana kuwedzera kwekuda kwezvinhu panzvimbo dzedata.

Hupenyu hwacho hunoenderana zvakananga nekuti kutonhora kunoshanda sei. MaTransformer anonyudzwa mumafuta anoita kuti insulation igare kwenguva inopfuura makore makumi matatu mumamiriro ekushanda akajairika nekuchengetedza tembiricha inotenderera iri pasi pemazinga akakosha. Makambani emagetsi anoshandisa zviteshi zvemagetsi munzvimbo dzegwenga kana munzvimbo dzinopisa anokoshesa chaizvo kusimba uku nekuti tembiricha dziri kunze dzinowanzo pfuura zvakarongerwa zvemayuniti anotonhodzwa nemhepo.

Kubudirira Kwakawedzerwa uye Kushivirira Zvakawandisa

Kana matransformer achishanda nguva dzese nekuchinja kwemitoro, kushanda zvakanaka kwakakosha. Mamodheru emazuva ano ane simbi isina chimiro anoshanda ne99%, zvinoreva kuti anorasikirwa nesimba shoma sezvinobvira kana asiri kushandiswa. Pamutoro we30%, izvo zvinoitika kakawanda husiku, magadzirirwo edu asingadhuri zvakanyanya anotambisa pasi pe3% yesimba rinoiswa. Izvi zvinoderedza mari yekushanda kune vatariri vezvivakwa vanogara vachitarisa mabhiri emagetsi pamwedzi.

Simba rekudzivirira kupisa kwemafuta rinoitawo kuti mawindings arongwe pamwe chete, izvo zvinoderedza saizi ukuwo maburi emagetsi achiramba akafanana. Izvi zvinoita kuti zvikwanisike kuisa muzviteshi zvemumaguta uko mutengo wevhu unoita kuti zvisave nyore kuva netsoka dzemidziyo mikuru. Transformer ye10MVA yakanyikwa mumafuta inotora nzvimbo shoma ne60% pane imwe yakaoma ine saizi imwe chete. Iyi ibhenefiti huru pakuvandudza zvivakwa zvekare muguta.

Mutengo-Kushanda Pamusoro pe Lifecycle

Mabhenefiti emari e transformers dzakanyikwa mumafuta anogona kuonekwa nekutarisa mutengo wese wekuva muridzi. Mitengo yekutanga yekutenga yakaderera ne15–25% pane dzimwe nzira dzakafanana dzemhando yakaoma kana dzakaputirwa negasi, izvo zvinobatsira mapurojekiti ipapo ipapo asina mari yakawanda. Mari yekugadzirisa yakaderera nekuti kuyedzwa kwemafuta nguva dzose uye kuchenesa zvakakwana pakushandiswa kwakawanda. Izvi zvakasiyana nemayuniti emhando yakaoma, ayo anoda kuti zvikamu zvawo zvese zvitsiviwe makore gumi kusvika gumi nemashanu ega ega.

Musiyano wemari inoshandiswa muhupenyu hwese wakakura kana uchifunga nezvekuchengetedza simba kubva pakushanda zvakanyanya uye nguva shoma yekushanda kubva pakushanda zvakanaka kwekupisa. Zvichienderana nemitengo yemagetsi yemaindasitiri uye mapatani ekutakura, unit ye25MVA inoshanda mufekitori yekugadzira inogona kuchengetedza $50,000 pagore mumari yemagetsi chete. Izvi zvinotsanangura kuti nei 70% yenzvimbo dzemagetsi pasi rese dzichiri kushandisa tekinoroji inonyudzwa mumafuta kunyangwe paine dzimwe nzira dziri nani.

Kufunga Nezvehunyanzvi uye Kuchengetedza Kuti Ishande Zvakanaka

Maitiro Ekuongorora Uye Kuedza Hunhu hweOiri

Kutsvagurudza mafuta kwakarongeka kunodiwa kuti matransformer arambe aine hutano. Nekuyera huwandu hwehydrogen, acetylene, uye carbon monoxide, ongororo yegasi yakanyungudutswa (DGA) zvichienderana neIEEE C57.104 standards inogona kuwana zvikanganiso zvisati zvaitika. Kuwanda kwehydrogen zvinoreva kuti system iri kutsva, uye mazinga eacetylene akakwira zvinoreva kuti system iri kudonha. Mamiriro ese aya ese anofanira kuongororwa nekukasika. Tinokurudzira kuti DGA iongororwe mwedzi mitatu yega yega yezvinhu zvakakosha zvakaita semasystem ekuchengetedza zvipatara kana nzvimbo dzinogadzira semiconductors uko nguva yekushanda inodhura inodarika $100,000 paawa.

Kuti chimiro chechinhu chinodzivirira kupisa chirambe chiripo, mwero wehunyoro unofanirwa kugara uri pasi pezvikamu gumi kusvika gumi nezviviri pamiriyoni. Karl Fischer titration inopa kuverenga kwakarurama kwehuwandu hwehunyoro mumafuta, izvo zvinobatsira pakusarudza kana oiri inofanira kuchenesa kana kutsiva. Kuongororwa kwemagetsi anopatsanurwa kunoita kuti simba re dielectric rirambe riri pamusoro pemazinga e30kV. Zvivako zviri pedyo nemahombekombe ane mvura kana zvinosangana nekuchinja kwekupisa kazhinji zvinoda kuongororwa kakawanda. Mitemo yedu yekuchengetedza inoda kuti kuongororwa kuitwe mwedzi wega wega panzvimbo penguva dzose katatu pagore kana mamiriro akaoma.

Maitiro Ekuongorora Kudzivirira Mhosva

Kunze kwekutsvagisa mafuta, kune dzimwe nzira dzekuwana matambudziko pakutanga. Kuedza transformer's turns ratio (TTR) mukati me ±0.5% kunoita kuti ma windings arambe aripo mushure mekufamba kana kudengenyeka kwenyika. Sweep frequency response analysis (SFRA) inowana shanduko muhunhu hwemakanika husingaonekwe nemaziso. Kuyerwa kwesimba remagetsi pa bushings dziri pasi pe 0.5% kunoratidza kuti insulation ine hutano, nepo kukosha kuri pamusoro pe 0.5% kuchiratidza kuti insulation iri kuputsika uye bushings dzinofanira kutsiviwa.

Kufungidzira kwekupisa pasi pemutoro kunoratidza nzvimbo dzinodziya kupfuura tembiricha yedhizaini. Izvi zvinowanzokonzerwa nekubatana kusina kusimba zvakakwana kana nzira dzekutonhodza dzakavharika. Kugadzirisa matambudziko aya kunomisa matambudziko makuru kuti asaitike. Ruzivo rwedu rwebasa remumunda runoratidza kuti kugadzirisa nekukurumidza kunoderedza kudzimwa kwemagetsi kusingatarisirwi ne65% zvichienzaniswa nenzira dzekugadzirisa dzinoshanda. Kana makambani eEPC achivaka nzvimbo itsva dzemagetsi, anofanira kusanganisira masisitimu ekutevera ari kure anochengetedza tembiricha yemafuta, huwandu hwegasi rakanyungudutswa, uye mamiriro emabushings. Masisitimu aya anofanira kutumira nyevero dzisati dzapfuura zvakachengeteka.

Chengetedzo uye Mafungiro Ezvakatipoteredza

Nekuti mafuta emugodhi anogona kubatira moto, maTransformer anonyudzwa mumafuta anoda michina yekuchengetedza moto. Tinotora matanho akawanda ekudzivirira: mavharuvhu ekudzivirira kumanikidzwa anomisa matangi kuputika panguva yekuisa mukati; madziro anodzivirira moto anoparadzanisa mayuniti muzvigadziro zvine jenareta rinopfuura rimwe chete; uye masisitimu ekudzvinyirira otomatiki anoburitsa gasi risina simba kana furo kana akanzwa dambudziko. Mvura yemazuva ano ine ester ine ma flash points akakwira kupfuura mafuta emugodhi (>300°C vs. 145°C), izvo zvinoita kuti zvive zvakachengeteka kushandisa pedyo nezvivakwa zvinogarwa.

Panguva yekugadzirisa nekubvisa basa, mitemo ine chekuita nezvakatipoteredza inotonga mashandisirwo emafuta. Mapolychlorinated biphenyls (PCBs) anowanikwa mumafuta etransformer akamboshandiswa kubva kumayuniti ekare. MaPCB anoonekwa semarara ane chepfu uye anofanira kuraswa nenzira yakati. Zvishandiso zvedu zvinoshandisa mafomula asina maPCB uye anotevedzera mitemo yeEPA neEU REACH. Kudonha kwemvura kunomiswa nemasisitimu ekudzivirira kudonha kwemvura, ayo anodiwa pakuisa pedyo nemvura kana nzvimbo dzine njodzi kune nharaunda.

Ungasarudza Sei Transformer Yakanyudzwa Mumafuta Yakakodzera Network Yako?

Kuongorora Simba Rinodiwa uye Zvinodiwa zveMutoro

Kuongororwa kwemutoro ndiyo nhanho yekutanga pakusarudza kugona kwakakodzera. Tsvaga huwandu hwezvinodiwa, uchifunga nezvekukura kwemangwana, wobva wawedzera mipata yekuchengetedza. Semuenzaniso, tinokurudzira kuti matransformer ave nehukuru hwe125 kusvika 150% yemutoro wepamusoro unotarisirwa. Nzvimbo yedata inoda kuwedzera 8MW pakutanga uye 12MW mumakore mashanu anotevera inofanira kusarudza yuniti ye15MVA kuitira kuti ikwanise kukura pasina kutsiva michina nekukurumidza. Kungwarira kwakakosha kunofanirwa kutorwa nemapurojekiti esimba rinogona kudzoreredzwa. Semuenzaniso, mapurazi ezuva ane 125% mitoro inopindirana kana mainverters akawedzera simba panguva yemasikati, zvinoreva kuti vanoda matransformer anogona kubata mafambiro ekupisa nekukurumidza.

Kugona kudzora voltage kwakakoshawo. Mamodheru ane ±0.5% voltage stability anoita shuwa kuti michina inonzwisisika senge maCNC nema medical imaging systems anogara achiwana simba, kunyangwe grid ikachinja. Magadzirirwo edu etap changer ane magadzirirwo mapfumbamwe anofukidza huwandu hwekugadzirisa voltage hwe±10%. Izvi zvakafanana nekuchinja-chinja kwemagridi emagetsi munzvimbo zhinji. Kureba kunokanganisawo mashandiro. Pamamita zviuru zvina, michina yedu ine mazinga epamusoro ichiri kushanda nesimba rakazara, nepo mayuniti akajairwa achidzikira ne15-20%.

Kuenzanisa Sarudzo dzeTekinoroji

Pane dzimwe nguva apo maTransformer anonyudzwa mumafuta anofanira kukwikwidzana nematransformer emhando yakaoma uye anonyudzwa negasi. Magadzirirwo emhando yakaoma anoshanda zvakanaka mumba, senge muzvivakwa zvemarefu kana mafekitori emakemikari, uko mvura ine njodzi isingabvumirwe nekuda kwemitemo yemoto. Asi nekuti haagone kubata zvakanyanya uye anorasikirwa nesimba rakawanda, haana kunaka kune mitoro inorema yemaindasitiri. Matransformer anonyudzwa negasi anoshandisa SF6 ane saizi diki uye haagone kubata moto, asi anodhura katatu kusvika kana kana kutenga kupfuura maversion anonyudzwa mumafuta. Izvi zvinoreva kuti anongobatsira chete kune nzvimbo dzemumaguta dzine nzvimbo shoma uko mari yevhu iri chikamu chikuru chebhajeti reprojekiti.

Nzvimbo dzakatikomberedza dzinosarudza matekinoroji akanakisa. Nzvimbo dzemahombekombe dzinofanira kubata nehutsi hwemunyu, zvinoreva kuti dzinoda nzvimbo dzekuchengetera dzine IP55-rated dzine matangi asingazove nengura. Mamodheru edu egungwa anouya nezvinhu izvi zvatovepo. Pamabasa ekuchera migodhi, magadzirirwo anodzivirira kudengenyeka kwenyika uye anosangana nezvinodiwa zvekudengenyeka kwenyika muZone 4 anodiwa. Magadzirirwo aya anofanira kusanganisira matangi akasimba uye mabushing connections anochinjika. Nekuti nzvimbo dzekuchenesa mafuta dzine mhepo inoputika, dzinoda mayuniti ane certification yeATEX ane zvinhu zvakakosha zvekuchengetedza.

Kudyidzana Nevakavimbika Vagadziri

Kuvimbika kwematransformer kunoenderana nekuti akagadzirwa zvakanaka sei uye kuti anotsigirwa zvakanaka sei mushure mekutengeswa. Makambani anotungamira pasi rose anochengeta ISO 9001 certification yavo uye anotevedzera mitemo yakatarwa neIEC 60076. Tinoedza matangi akasungirirwa kuti aone kana achibuda simba maawa makumi maviri nemana pazuva kuti tive nechokwadi chekuti akasimba tisati tatumira. Kuongororwa kwezvinhu kunoratidza kuti macores akagadzirwa nesimbi inotarisa zviyo anosangana nezvinodiwa zve magnetic flux density, izvo zvine chekuita zvakananga nema scores ekushanda zvakanaka.

Mapoka ekutenga anofanira kuve nechokwadi chekuti makambani avari kutarisa anopa ruzivo rwakadzama, senge mishumo yebvunzo, mamodheru emhando, uye zvidzidzo zvekuchengetedza. Sekureva kweIEC 60076-3, nzira dzekuongorora kugamuchirwa kwefekitori (FAT) dzinofanira kusanganisira bvunzo dzekudzivirira simba remagetsi. Miedzo iyi inoita kuti ive nechokwadi chekuti insulation inogona kubata kurohwa nemheni uye switching spikes. Sechikamu chemaitiro edu eFAT, tinoedza kugona kwe short-circuit pasi pemamiriro ezvinhu ekutadza akaedzwa. Izvi zvinoita kuti tive nechokwadi chekuti simba remakanika uye thermal standing ratings zvinoenderana nezvakataurwa ne nameplate.

Kutenga uye Rutsigiro Mushure meKutenga kweVatengi veB2B

Nzira yeKutsvaga Zvinhu uye Kusarudzwa kweVatengesi

Paunenge uchitsvaga vatengesi vakavimbika vematransformer akanyudzwa mumafuta , unofanirwa kuongorora zvinopfuura mutengo chete. Nguva dzekutungamira dzinoenderana nekukwanisa kugadzira—nzvimbo yedu yekugadzira ye200,000-square-meter inopedzisa mayuniti e35kV akagadzirwa mumavhiki gumi nemaviri, nepo vagadziri vadiki vanowanzo da mavhiki makumi maviri kusvika makumi maviri nemana. Kuva pedyo nenzvimbo dzekushandira kunoderedza nguva dzekupindura nekukurumidza. Tinochengetedza mahofisi emumunda muNorth America yese ane zvikamu zvekuwedzera, zvichiita kuti tikwanise kufambisa mukati memaawa makumi mana nemasere.

Kutengesa kwakagadzirwa nevatengi uye kukuru kunogona kukubatsira kuchengetedza mari. Kuchengetedza mari kubva pa12 kusvika ku18% pamitengo yakatarwa kunowanikwa kumapurojekiti anotenga mayuniti gumi kana anopfuura akafanana. Sarudzo dzekugadzirisa dzinokutendera kuti ugutse zvinodiwa newebsite yako. Semuenzaniso, unogona kusarudza dhizaini diki yenzvimbo yemuguta yakaoma kusvika, mabushing marefu ekuisa vault yepasi pevhu, kana setup yekumonera yakagadzirwa inoshanda nemagetsi asingawanzo shandiswa. Kubatanidzwa kwekutanga kwevatengesi mukuronga mapurojekiti nemapoka einjiniya kunoita kuti zvinodiwa zvigadziriswe vasati vavhara mabhidhi.

Mitemo yeWaranti uye Zvibvumirano zveBasa

Vimbiso dzakajairika dzinofukidza zvikamu zvese uye dzinoshanda kwemwedzi makumi maviri nemana kusvika makumi matatu nematanhatu, asi zvibvumirano zvebasa rakazara zviri nani. Waranti yedu yemakore gumi inovhara mafoni ekudzivirira kugadziriswa kamwe chete pagore, mukana wekuwana zvikamu pakutanga, uye nhare dzerutsigiro rwehunyanzvi dzinoshanda maawa makumi maviri nemana pazuva, mazuva manomwe pasvondo nenyanzvi dzinoziva magadzirirwo emidziyo yenyu. Zvibvumirano zvebasa (SLAs) zvinotsanangura zvipikirwa zvekupindura. Semuenzaniso, tinovimbisa kupindura nekukurumidza kwemaawa mana kune zvakakosha, nematekinoroji emumunda anotumirwa nekukurumidza patinongoziviswa.

Rubatsiro pakuiswa kwechinhu runoderedza njodzi yekutanga. Matimu edu anoita ongororo dzekugadzirira nzvimbo kuti ave nechokwadi chekuti nheyo dzinosangana nezvinodiwa zvekutakura uye nzvimbo dzinoenderana nemutemo wemagetsi. Sechikamu chemabasa ekutanga, oiri inogadziriswa kubvisa hunyoro nezvidimbu, kuzara kwevacuum kunoitwa kudzivirira magasi, uye kutarisa simba kunoitwa kuti zvese zvishande zvakanaka nguva isati yasvika. Mabasa aya anoderedza mwero wekukundikana we15% unoonekwa kana kuiswa kwaitwa mumunda pasina kutarisirwa.

Rutsigiro Rwakaenderera Mberi

Nzvimbo dzekutsigira dzinofanira kunge dziri nyore kuwana kuti zvinhu zvibudirire kwenguva refu. Tine maturusi anogona kushandiswa kuvandudza maTransformers ekare anonyudzwa muOiri nemasisitimu matsva ekutevera. Izvi zvinogona kuwedzera makore gumi kusvika gumi nemashanu pahupenyu hwawo hwekushanda ne30% yemari yekuatsiva. Kugadzirisa kunogona kusanganisira zvese kubva pakuchinja mabushing mashoma kusvika pakudzoserwa shure zvachose mushure mekukanganisa. Mayuniti anodzoserwa kune zvawo zvepakutanga uye anouya nevimbiso dzinoenderana nedzemichina mitsva.

Zvirongwa zvekugadzirisa zvakarongwa zvinogadzirisa nguva pakati pemasevhisi zvichienderana nekushandiswa kwemuchina. Kuongorora kunoitwa mwedzi mitatu yega yega pazviteshi zviri munzvimbo dzakaoma, asi kamwe chete pagore panzvimbo dzinodzorwa nemamiriro ekunze. Puratifomu yedu yekuongorora data nemafuta inotarisa kutarisa data uye mhinduro dzebvunzo kuti vaone kuti ndeapi magadzirirwo anofanirwa kuitwa mwedzi mitatu kusvika mitanhatu kubva zvino. Nzira iyi yekukurumidza yakaderedza huwandu hwetsaona dzisingatarisirwi ne70% kune vatengi vari muzvirongwa zvedu zvebasa zvinotarisirwa.

blog-1-1

mhedziso

Nekuti ndivo vanonyanya kubata kupisa, kushanda zvakanaka, uye kushandisa mari shoma, maTransformer anonyudzwa mumafuta achiri kudiwa muma network ane mutoro wakawanda. Nekuti anogona kubata overloads kwenguva refu uku achichengetedza simba remagetsi rakakwirira, anodiwa munzvimbo dzakadai semafekitori, nzvimbo dzedata, uye nzvimbo dzekushandisa uko nguva yekushanda yakabatana zvakananga nekuvimbika. Kuti usarudze zvakanaka, unofanirwa kunyatsotarisa maitiro ekutakura, zvinhu zvakatipoteredza, uye mitengo muhupenyu hwese hwechigadzirwa. Kushanda pamwe chete nevagadziri vanopa rutsigiro rwakazara, kubva kuinjiniya chaiyo kusvika kumakumi emakore ebasa remumunda, kwakakoshawo kuve nechokwadi chekuti zvinhu izvi zvakakosha zvinoramba zvichishanda zvakanaka muhupenyu hwavo hwebasa hwemakore anopfuura makumi matatu. Nekufamba kwenguva, matekinoroji matsva akadai se amorphous cores uye ester fluids anosundira miganhu yekuchengetedzeka nekushanda zvakanaka, achichengetedza basa rema transformer anonyudzwa mumafuta mukupa simba kuzvivakwa zvemangwana.

FAQ

1. Matransformer anonyudzwa mumafuta anofanira kuongororwa kangani?

Kugadziriswa kunoitwa kangani kunoenderana nekuti zvinhu zviri kufamba sei uye kuti zvakakosha sei. Kuisa kwakajairika kunoda kuongororwa kwakazara kamwe chete pagore, kunosanganisira kutora sampuli yemafuta eDGA uye kuyedzwa kwehunyoro, kutarisa mamiriro emabushings netangi nemaziso, uye kushandisa thermal imaging apo tangi rakazadzwa. Matransformer anoshanda munzvimbo dzakaoma dzine guruva rakawanda, hunyoro, kana shanduko dzetembiricha anobatsirwa nekuongororwa kwemafuta mwedzi mitatu yega yega. Pamashandisirwo akakosha akadai sezvipatara kana nzvimbo dzedata, kutarisa kunofanirwa kuitwa kamwe chete pamwedzi uchishandisa ma sensors otomatiki anochengetedza hunhu hwemafuta netembiricha nguva dzese. Kutevedzera mitemo yekuchengetedza muIEEE C57.106 kuchaita shuwa kuti system yako yakavimbika sezvinobvira uye kuchengetedza mitengo yebasa rako yakachipa.

2. Matransformer akanyudzwa mumafuta anogona kushanda zvakachengeteka munzvimbo dziri kunze here?

Kana dzagadzirwa zvakanaka, ma transformer aya anoshanda zvakanaka pakushandiswa panze. Makontena ane chiyero cheIP55 anochengetedza guruva nemvura, uye matangi anodzivirira ngura anogona kubata mhute yemunyu inobva kumahombekombe kana kusvibiswa kubva kumafekitori. Tembiricha yekushanda inotangira pa -40°C kusvika +55°C inogona kubata nzvimbo dziri munzvimbo dzakaoma, kubva kuArctic kusvika kurenje. Munguva yekupisa, silica gel breatherers inochengetedza hunyoro kuti husapinde musystem. Sekureva kweNFPA 70 electrical codes, mayuniti ekunze anofanirwa kunge ari kure nemamita matatu kubva kuzvivakwa uye aine masisitimu ekudzivirira moto uko mitemo inoti anofanira. Zviuru zvema utility substations pasi rese zvave zvichishandiswa panze kwemakumi emakore pasina matambudziko chero bedzi zvichitevera nzira dzakakodzera dzekugadzirisa.

Batana naXi'an Xikai kuti uwane zvaunoda paTransformer ine mutoro wakawanda

Kusarudza mupi akakodzera wejenareta inonyudzwa mumafuta kunogona kuva nemigumisiro inogara kwenguva refu pakushanda kwayo zvakanaka. Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. yave ichigadzira zvinhu kwemakore anopfuura makumi maviri nemashanu uye inogona kukubatsira nemapurojekiti ako akakosha emagetsi. Zvigadzirwa zvedu zvinosanganisira makirasi emagetsi e10kV, 35kV, uye 110kV, ane kugona kuzadzisa zvinodiwa nemagetsi, magridi emagetsi, uye kuisa simba rinodzokororwa. MaTransformer edu anonyudzwa mumafuta anosangana nezvinodiwa zvepasi rose nekuda kwekubvumidzwa kwedu kweIEC 60076, ISO 9001, CE, UL, uye GOST-R. Kubva pakuongororwa kwemapurojekiti kusvika pakuiswa kwemagetsi uye kugadzirisa kwehupenyu hwese, timu yedu yenyanzvi inowanikwa maawa makumi maviri nemana pazuva, mazuva manomwe pasvondo.

Taura ne serina@xaxd-electric.com , amber@xaxd-electric.com , kana luna@xaxd-electric.com kuti utaure nemumwe wemainjiniya edu ekushandisa nezve zvaunoda. Kana uchida imwe chete kana dzakawanda dzemasite akawanda, Xi'an Xikai anogona kukubatsira. Mhinduro dzavo dze transformer dzakanyikwa mumafuta dzakavimbika, uye dzinouya newaranti dzakazara uye sarudzo dzebasa remumunda.

blog-1-1

References

1. IEEE Standard C57.104-2019: Gwaro reKududzira Magasi Anogadzirwa muMineral Oil-Immersed Transformers, Institute of Electrical and Electronics Engineers, New York, 2019.

2. IEC 60076-1:2011: Mashanduko eSimba - Chikamu 1: Zvinodiwa Zvakawanda, International Electrotechnical Commission, Geneva, 2011.

3. Heathcote, MJ, Bhuku reJ&P Transformer: A Practical Technology of the Power Transformer, Chinyorwa chechi13, Newnes Publishers, Oxford, 2007.

4. Harlow, JH, Electric Power Transformer Engineering, Chinyorwa chechitatu, CRC Press, Boca Raton, 2017.

5. CIGRE Working Group A2.37, Ongororo yeTransformer Reliability: Mushumo weChinguvana, CIGRE Technical Brochure 642, Paris, 2015.

6. Myers, SD, Kelly, JJ, naParrish, RH, Gwaro reKugadzirisa Transformer, SD Myers Inc., Ohio, 2003.

tuma