productPic

Kuzviporesa Capacitor

1. Rated Voltage(Ue): 250v ~ 525v, kusvika 2000v.
2. Kakawanda:50/60Hz.
3. Dhizaini diki, yakashongedzerwa nebhaudhi rekudzika.
4. Zvinhu zvekushandisa muhari: PU resin (soft resin).
5.Kuisa uye kuisa waya zviri nyore.
6.Saizi diki, Huremu hwakareruka.
7. Kuzvirapa, Kuchengetedza-kusina.
  • Fast Delivery
  • Quality Panga
  • 24/7 Vatengi Sevhisi

Product Introduction

Kuzviporesa Capacitor

Product Introduction

Uri kutsvaga mhinduro dzemagetsi dzakavimbika dzemhando yepamusoro dzemagetsi ako here? Self-healing Capacitor yedu inopa mashandiro akanaka uye kuvimbika kumashandisirwo emaindasitiri nemabhizinesi. Yakagadzirwa neXi'an Xidian Medium and Low Voltage Electrical Co., Ltd, ma capacitor aya anoshandisa tekinoroji yepamusoro ye polypropylene film ine hunyanzvi hwekuzviporesa. Paunosarudza ma capacitor edu, unenge uchiisa mari mumidziyo yakagadzirirwa kuvandudza simba, kuderedza kurasikirwa kwe reactive, uye kusimudzira simba remagetsi muma network ako ekugovera magetsi mashoma. Self-healing Capacitor yega yega ine mashandiro asingagadzirisike uye nzira dzakakwana dzekudzivirira kuchengetedzeka.

Ma capacitor aya akagadzirwa zvakanangana nemasisitimu eAC ane simba-frequency. Anopa kugona kwekubatanidza shunt kunovandudza mashandiro emagetsi ako. Dhizaini yedu diki inoita kuti zvive nyore kubatanidzwa mumasisitimu aripo ukuwo ichipa hunhu hwemagetsi hwakanaka.

Technical Magadzirirwo

Parameter Specification
Rated Voltage (Ue) 250V, 400V, 460V, 480V, 525V, 660V (kusvika 2000V)
maitikiro 50 / 60 Hz
Insulation Level 3kV
Dielectric Kurasikirwa <0.0010 (20°C, 50Hz)
uchishandisa Temperature -20 ° C kusvika + 50 ° C
Altitude Kusvika 2000m (mhando dzenzvimbo dzakakwirira dziripo kusvika 4000m)
encapsulation PU Resin (Soft Resin) / Thermosetting Resin
Housing Material 1mm Yakabatidzwa Simbi Sheet
Discharge Nguva Voltage inodonha pasi pe75V mukati memaminitsi matatu mushure mekudzima magetsi
Standards GB/T 12747.1&2-2004, IEC60831-1&2

Main Features uye Zvakanakira

Tekinoroji Yekuzvirapa Yepamusoro

Ma capacitor edu ane hunhu hwekuzviporesa otomatiki. Kana paine kukanganisika kudiki kwe dielectric, firimu resimbi rinongoerekana rapwanyika richitenderedza nzvimbo yakakanganisika, richiparadzanisa nzvimbo yakakuvara pasina kukanganisa mashandiro ese.

Kuwedzerwa Kudzivirirwa Kwekuchengetedza

Chinhu chimwe nechimwe che capacitor chinosanganisira michina yekudzivirira yakavakirwa mukati iyo inotarisa mamiriro ekupisa kwakanyanya, kupisa kwakanyanya, uye kumanikidzwa kwakanyanya. Iyi tekinoroji yakachengetedzwa ne patent (Patent Nhamba 200810150609.1) inoita kuti system yako irambe yakachengetedzwa.

Yakakwana uye Yakareruka Dhizaini

Kuvaka uku kunochengetedza nzvimbo kunoderedza kufambiswa kwenzvimbo. Uchaona kuti kuisa nekubatanidza waya zviri nyore uye mabhaudhi ekudzika aripo.

Yakanakisa Heat Dissipation

Kupatsanurwa kwenzvimbo pakati pezvinhu zvemukati kunoita kuti kupisa kupfuure zvakanaka. Chigadziko chesimbi chinoita kuti kupisa kutarisirwe zvakanaka, zvichiwedzera hupenyu hwekushanda.

Kugadzirisa-Kushanda Kwemahara

Kana yangoiswa, Self-healing Capacitor yako haidi kugadziriswa nguva dzose. Iyo resistor inoburitsa mweya inogara yakabatana inoita kuti voltage ideredzwe zvakachengeteka mushure mekubviswa.

Low Kurasikirwa Kwekuita

Firimu repolypropylene rine simbi rinoita basa guru rinoderedza kurasikirwa kwe dielectric. Kubatanidzwa kwebronze mukati kunoderedza kuwanda kwemagetsi uye kuramba kubatwa, zvichiita kuti simba rishande zvakanaka.

Kusimba Kwezvakatipoteredza

Kugadzirisa vacuum uye thermosetting resin encapsulation zvinobvisa zvachose zvinhu zvemukati kubva pahunyoro hwekunze uye zvinosvibisa.

Applications Applications

Bhizinesi rako rinogona kubatsirwa nema capacitor edu muzvikamu zvakasiyana-siyana:

  • Industrial Manufacturing: Kuvandudza simba remagetsi munzvimbo dzekugadzira nemotokari dzinorema
  • Zvivako zvekutengesa: Gadzirisa mashandiro emagetsi mumahofisi nenzvimbo dzekutenga
  • Power Distribution Networks: Kuvandudza kunaka kwesimba regrid uye kuderedza kurasikirwa kwekutumira
  • Renewable Energy Systems: Tsigira kubatanidzwa kwezuva nemhepo nekusimbisa simba remagetsi rinoita basa
  • Infrastructure Projects: Zviteshi zvezvitima, nhandare dzendege, nenzvimbo dzekutakura vanhu dzinoda magetsi akasimba
  • Metallurgy uye Petrochemical: Kugadzirisa mamiriro ezvinhu akaomarara mumafekitori ekugadzirisa
  • Kuvaka Kwemaguta: Masisitimu emagetsi eguta akangwara uye kuvandudzwa kwezvivakwa zvemazuva ano

Ainoita

Nzira yekuzviporesa inoshanda kuburikidza netekinoroji yefirimu yakagadzirwa nesimbi. Kana kushushikana kwakanyanya kwakaitika munzvimbo yacho muchikamu che dielectric, chifukidziro chesimbi chakatetepa kwazvo chinopera pakarepo. Izvi zvinogadzira nzvimbo inodzivira yakatenderedza poindi yekutadza, zvichidzoreredza otomatiki kushanda kwakajairika.

Zvinhu zvinogadziriswa ne vacuum zvinovharwa ne thermosetting resin, zvichiita kuti pave nechinhu chisingapindi mvura. Izvi zvinodzivirira kubva kuzvinhu zvakatipoteredza zvinowanzo kanganisa mashandiro e capacitor.

Kana ukabatanidza capacitor kune yako AC power system, inopa reactive power compensation. Izvi zvinovandudza power factor yako nekudzima inductive loads kubva kumamota nematransformer. Mugumisiro wacho? Kuderedzwa kwemitengo yemagetsi uye kuvandudzika kwevoltage munzvimbo yako yese.

Chinodzivirira kubuda chinogara chakabatana chinovimbisa kuti chinobatwa zvakachengeteka. Mukati memaminitsi matatu ekubvisa, magetsi akasara anodzikira pasi pe75V, zvichidzivirira vashandi vako vekugadzirisa.

Kugadzira Kunaka

KuXi'an Xidian Medium and Low Voltage Electrical Co., Ltd, tinochengetedza mitemo yemhando yepamusoro. Nzvimbo yedu yekugadzira inoshandisa matekiniki epamusoro ekugadzira uye kudzora mhando zvakanyanya padanho rega rega.

Takashandisa masisitimu akakwana ekutarisira anosanganisira ISO9001 (Kutarisira Hunhu Hwakanaka), ISO14001 (Kutarisira Zvakatipoteredza), uye OHSAS18001 (Hutano Hwebasa uye Kuchengetedzwa). Zvitupa izvi zvinoratidza kuzvipira kwedu kune kugona.

Chikwata chedu chekutsvagisa nekugadzira zvinhu chinoramba chichiwedzera zvinhu zvitsva. Sevatori vechikamu mumapurojekiti enyika, tinobatanidza tekinoroji yemazuva ano mukugadzira zvigadzirwa zvedu. Izvi zvinoita kuti muwane michina inosangana nezvinodiwa pari zvino uye mune ramangwana.

Capacitor yega yega inoedzwa zvakakwana isati yabva panzvimbo yedu. Kubva pakuongororwa kwezvinhu zvakagadzirwa kusvika pakusimbiswa kwechigadzirwa chekupedzisira, hatina kana kumbokanganisa.

Sei Tichifanira Kusarudza Ife?

Comprehensive Product Range

Tinopa mhinduro dzakakwana dzekugovera magetsi kunze kwema capacitor. Portfolio yedu inosanganisira switchgear, transformers, circuit breakers, nezvimwe muzvikamu zvipfumbamwe uye mhando dzinopfuura zana.

Yakaratidzwa Track Record

Zvigadzirwa zvedu zvinopa mabasa anoda simba munyika yese. Tawana mukurumbira sekambani ine mukurumbira muChina nekuda kwekushanda kwayo nguva dzose uye kuvimbika.

Unyanzvi hwehunyanzvi

Nemakore akawanda eruzivo muindasitiri, timu yedu yeinjiniya inopa mazano ehunyanzvi. Tinokubatsira kusarudza magadzirirwo akakodzera zvaunoda.

Customization kugona

Unoda ma voltage ratings chaiwo kana ma configurations? Tinopa mhinduro dzakagadzirirwa iwe pachako dzakagadzirwa zvinoenderana nematambudziko ako ekushandisa.

Responsive Support

Chikwata chedu chakazvipira chinovimbisa kuti munowana rubatsiro panguva yakakodzera. Kubva pakubvunza kwekutanga kusvika pakuiswa uye zvichienda mberi, tiri pano kuti titsigire kubudirira kwenyu.

Yemakwikwi Kukosha

Mitengo yedu ichakwikwidzana uku tichichengetedza mwero wemhando yepamusoro usingachinji. Tinopa kukosha kwechokwadi kwemari yawaisa.

FAQ

Mubvunzo: Chii chinoita kuti ma capacitor aya "azviporese ega"?

A: Firimu rakaiswa simbi rinozviparadzanisa roga nekubvisa simbi yakakomberedza nzvimbo dzakakuvara, richidzoreredza kushanda kwakajairika pasina kupindira nemaoko.

Mubvunzo: Ma capacitor aya anowanzogara kwenguva yakareba sei?

A: Kana mamiriro ekushanda akakodzera, ma capacitor edu anopa makore mazhinji ebasa risina kugadziriswa. Hupenyu chaihwo hunoenderana nemamiriro ekunze uye hunhu hwemutoro.

Mubvunzo: Ndingashandisa ma capacitor aya here pakuisa zvinhu panze?

A: Mamodheru edu akajairika akagadzirirwa kushandiswa mukati memba. Tibatei kuti muwane mhinduro dzakatarwa panze dzakanangana neapplication yenyu.

Mubvunzo: Ndechipi chiyero chemagetsi chandinofanira kusarudza?

A: Sarudza chiyero chemagetsi chinoenderana kana kuti chinopfuura zvishoma voltage yesystem yako. Chikwata chedu chinogona kukubatsira kusarudza chidimbu chakakodzera.

Mubvunzo: Unopa rubatsiro rwekuisa?

A: Ehe, tinopa gwara rehunyanzvi rekuisa zvakanaka. Magwaro edu anosanganisira tsanangudzo dzakadzama uye madhayagiramu ekubatanidza.

Mubvunzo: Zvikamu zvinotsiva zviripo here?

A: Kunyange hazvo ma capacitor aya asingagadziriswe, tinochengetedza zvinhu zvakawanda zvekuchengetedza kuti titsigire system yese.

Mubvunzo: Ungakurumidza sei kuzadzisa mirairo?

A: Nguva dzekutumira zvinhu dzinosiyana zvichienderana nehuwandu uye zvinodiwa. Tibatei kuti muzive nezvekuwanikwa kwazvino uye hurongwa hwekutumira.

Taura nesu

Wagadzirira kuvandudza simba rako nemhinduro dzedu dzepamusoro dze capacitor? Nyanzvi dzedu dzehunyanzvi dziripo kuti dzikurukure zvaunoda.

Email: serina@xaxd-electric.com

Taura nesu nhasi kuti uwane ruzivo nezvechigadzirwa, hunyanzvi, mitengo, kana kugadzirwa kwemhinduro dzakagadzirirwa iwe. Tinopindura mibvunzo yese nekukurumidza uye tinotarisira kutsigira zvaunoda pakugadzirwa kwemagetsi.

Ngatikubatsirei kugadzirisa sisitimu yenyu yekugovera magetsi netekinoroji ye capacitor inoshanda zvakanaka uye ine hunyanzvi hwekugadzira uye sevhisi inopindura.

---

Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd - Mubatsiri wenyu waunovimba naye wekugadzirisa magetsi zvakakwana.

tuma