Capacitor ea Sefahla sa Mokhahlelo o le Mong
2.Mehaho e mecha le theknoloji e ncha, botšepehi bo phahameng.
3.Lerata le tlaase, khanyetso e phahameng ea bokhoni bo feteletseng, thepa ea motlakase e fihlile boemong bo phahameng ba machaba.
4. Ka theknoloji e tsoetseng pele ea machaba ea li-fuse tsa kahare, netefatsa ts'ebetso ea sehlahisoa e tšepahalang. E ntlafalitse mokhoa oa khokahano oa khanyetso ea ho ntša metsi 'me ea rarolla bothata ba motlakase o feteletseng oa karolo ea letoto.
5.No leakage, mofuta o mocha oa bushings automatic argon arc welding tanks.
- Phano e potlakileng
- boleng tiisetsa
- Tšebeletso ea Bareki ea 24/7
Product Introduction
Sefahla sa Sefahla sa Mokhahlelo o le Mong - Litharollo tsa Boleng ba Matla a Setsebi
Product Introduction
Ha o hloka ho lokisa motlakase ka mokhoa o tšepahalang bakeng sa litsamaiso tsa hau tsa motlakase, Sefafatsi sa rona sa Mokhahlelo o le Mong se fana ka ts'ebetso e ikhethang le ho tšoarella. Karolo ena e ikhethang ea polokelo ea matla e etselitsoe ts'ebetso e tsoelang pele lipotolohong tsa motlakase tsa mokhahlelo o le mong, e ntlafatsa ho feto-fetoha ha motlakase ka katleho le ho thibela tšitiso ea motlakase. Sefafatsi sa rona sa Mokhahlelo o le Mong se na le theknoloji e tsoetseng pele ea filimi ea polypropylene e entsoeng ka tšepe, e fanang ka bokhoni bo phahameng ba ho sefa bakeng sa lits'ebetso tsa motlakase tsa motlakase tsa sejoale-joale.
Li-capacitor tsa rona li rarolla liphephetso tsa bohlokoa tsa boleng ba motlakase libakeng tsa indasteri le tsa khoebo. Li felisa ho sotha ha harmonic, li fokotsa maqhubu a bese ea DC, 'me li sireletsa lisebelisoa tse bonolo ho tsoa lerata le tsamaisoang ke grid.
Technical tobileng
| paramethara | latela boleng ba | Standard |
|---|---|---|
| Voltage Range | 250V - 1000V AC | IEC 61071 |
| Capacitance | 1μF - 100μF | ± 5% mamello |
| bueloang Mocheso | -40 ° C ho + 105 ° C | Boholo bo atolositsoeng |
| Lisebelisoa tsa Dielectric | Polypropylene e entsoeng ka tšepe | Boiketsi ba ho fodisa |
| ESR | <0.1Ω | Moralo o nang le tahlehelo e tlase |
| ESL | < 10nH | Ho sefa maqhubu a phahameng |
| Ho hanyetsa ho kenya letsoho | > 10GΩ | Ho itšehla thajana ho phahameng |
| Ts'ireletso ea Ts'ireletso | UL 810, IEC 61071 | Ho lumellana ha machaba |
| Ho koala | IP65 e fumaneha | Tšireletso ea tikoloho |
| ntseng bo eketseha | Likhetho tsa PCB/Chassis | Sesebelisoa sa ho kenya |
Lintlha Tse ka Sehloohong le Melemo
Theknoloji e Tsoetseng Pele ea ho Ipholisa
Li-capacitor tsa rona li na le kaho ea filimi ea polypropylene e entsoeng ka tšepe. Ha ho hlaha li-spikes tsa motlakase, metallization e fetoha mouoane ka bo eona ho potoloha libaka tse nang le liphoso, e leng se netefatsang ts'ebetso e tsoelang pele.
Ts'ebetso e Phahameng ea Thermal
E entsoe bakeng sa maemo a mocheso o feteletseng ho tloha ho -40°C ho isa ho +105°C. Mefuta ena e mengata ea ts'ebetso e netefatsa ts'ebetso e tšepahalang libakeng tse hlokang boiteko bo bongata.
Moqapi o tlase oa ESR
Khanyetso e tlase haholo ea letoto le lekanang e fokotsa ho iphuthumatsa tlas'a maqhubu a phahameng a maqhubu. Moralo ona o atolosa bophelo ba ts'ebeletso mme o ntlafatsa katleho ea ho sefa.
Botebo ba Matla a Manyenyane
Moralo o bolokang sebaka o dumella ho kopanngwa le meralo ya dikhabinete tse laolwang ka thata ntle le ho beha tshebetso kotsing.
Likarolo tsa Tšireletso tse Ntlafetseng
Li-connector tse feteletseng le theknoloji ea lifilimi tse arotsoeng ka likarolo li thibela ho hloleha ho hoholo, li sireletsa sistimi eohle ea hau ea motlakase.
Liketso tse sebetsang
Mekhoa ea UPS ea Mokhahlelo o le Mong
Li-capacitor tsa rona li ipabola mohatong oa khokahano ea DC oa litsamaiso tsa UPS tse fetolelang habeli inthaneteng. Li ntlafatsa motlakase ho sireletsa lintlha tsa bohlokoa nakong ea ho tima ha motlakase le ho feto-fetoha ha gridi.
Li-inverters tsa Solar PV
E loketse bakeng sa ho kenya matla a letsatsi a matlo ho tloha ho 3kW ho isa ho 10kW. Diyuniti tsena di tsitsisa motlakase wa bese ya DC ho tloha diphanele tsa letsatsi, di netefatsa bokgoni bo phahameng ba ho latela dintlha tsa motlakase.
Lisebelisoa tsa Likoloi tsa Motlakase
E loketse liteishene tsa ho tjhaja tsa Boemo ba 1 le Boemo ba 2 ba AC. Capacitor ea rona ea Sefahla sa Mokhahlelo o le Mong e sebetsana le ho thothomela mme e fana ka matla a manyane bakeng sa lits'ebetso tsa likoloi.
Likoloi tsa Liindasteri
E bohlokoa bakeng sa li-drive tsa maqhubu a feto-fetohang le litsamaiso tsa servo moo boleng ba matla bo amang ts'ebetso le bolelele ba lisebelisoa ka kotloloho.
How It Works
Sefahla sa hao sa Mokhahlelo o le Mong se sebetsa ka ho theha tsela e nang le impedance e tlase bakeng sa lerata la maqhubu a phahameng ha ka nako e ts'oanang se boloka matla a motlakase ho koala dikgeo mefuteng ya maqhubu a AC a lokisitsweng.
Dielectric ea filimi ea polypropylene e entsoeng ka tšepe e boloka tjhaja ea motlakase ka katleho. Nakong ea ts'ebetso, capacitor e tjhaja ha motlakase o kenang o phahama 'me o tsoa ha motlakase o theoha, e leng se etsang hore motlakase o phalle hantle.
Lerata la ho fetola maqhubu a phahameng le fumana tsela e bonolo ka hara moralo o tlase wa ESL wa capacitor. Sena se thibela tshitiso ho fihlella dikarolo tse bonolo tse theohelang tlase.
Mokhoa oa ho iphekola o sebetsa nakong ea li-transients tsa motlakase, o arola liphoso ka bohona le ho boloka botšepehi ba potoloho.
Bokhabane ba Tlhahiso
Xi'an Xikai Medium and Low Voltage Electric Co., Ltd. e tlisa boiphihlelo ba mashome a lilemo ba lisebelisoa tsa motlakase ho capacitor e 'ngoe le e 'ngoe eo re e etsang. Sistimi ea rona ea taolo ea boleng e netefalitsoeng ke ISO9001 e netefatsa ts'epo e tsitsitseng ea sehlahisoa.
Re sebelisa mela e tsoetseng pele ea tlhahiso e iketsang e nang le lisebelisoa tsa ho kobeha ka nepo le tlhahlobo ea khatello ea tikoloho. Yuniti ka 'ngoe e feta litekong tse matla ho kenyeletsoa ho mamella motlakase, tekanyo ea bokhoni, le potoloho ea mocheso.
Sehlopha sa rona sa lipatlisiso le nts'etsopele se ntlafatsa meralo khafetsa ho latela data ea ts'ebetso ea tšimo le litlhoko tse ncha tsa indasteri. Re boloka likamano tsa maano le bafani ba thepa ba ka sehloohong ho netefatsa boleng ba likarolo.
Taolo ea boleng e atoloha ho pholletsa le ketane ea rona ea phepelo. Lisebelisoa tse kenang li hlahlojoa le ho hlahlojoa pele li sebelisoa tlhahisong. Lihlahisoa tsa ho qetela li hlahlojoa ka motlakase ka 100% le ho nka sampole ka mokhoa o sa reroang bakeng sa netefatso ea nako e telele.
Lebaka Leo re Lokelang ho le Khetha
Boiphihlelo bo netefalitsoeng ba indasteri
Ka boiphihlelo bo boholo ba lisebelisoa tsa kabo ea motlakase o mahareng le o tlase, re utloisisa liphephetso tseo lits'ebetso tsa hau li tobanang le tsona lefatšeng la 'nete.
Tšehetso ea tekheniki
Sehlopha sa rona sa boenjiniere se fana ka thuso ea ts'ebeliso, se u thusa ho khetha litlhaloso tse ntle ka ho fetisisa tsa capacitor bakeng sa litlhoko tsa hau tse ikhethileng.
Thepa e Tšepahalang
Re boloka maemo a lekaneng a thepa le bokgoni ba tlhahiso bo tenyetsehang ho fihlela kemiso ea hau ea ho tlisa thepa ka mokhoa o tsitsitseng.
Tlhōlisano ea tlhōlisano
Theko e tobileng ea moetsi e felisa matšoao a barekisi ha ka nako e ts'oanang e boloka maemo a boleng bo holimo.
Tiisetso e Felletseng
Capacitor e 'ngoe le e 'ngoe e kenyelletsa tšireletso e felletseng ea waranti le tšehetso ea tekheniki e arabelang ho pholletsa le potoloho ea bophelo ba sehlahisoa.
LBH
P: See se fapana jwang le di-capacitor tsa ho qala ha enjene?
K: Li-capacitor tsa rona tsa sefe li entsoe bakeng sa mosebetsi o tsoelang pele ka moralo o tlase oa ESR. Li-capacitor tsa ho qala ha enjene ke tsa tšebeliso ea nakoana 'me li tla hloleha haeba li sebelisoa bakeng sa lits'ebetso tsa sefe.
P: Ke eng e amang bophelo ba capacitor?
K: Mocheso o sebetsang ke ntlha ea bohlokoa. Keketseho e 'ngoe le e 'ngoe ea mocheso oa 10°C ha e le hantle e arola nako ea ts'ebeletso e lebelletsoeng. Tsamaiso e nepahetseng ea mocheso ke ea bohlokoa.
P: Ke lokela ho nkela li-capacitor tsena sebaka neng?
A: Nka sebaka ha capacitance e theoha ka 5-10% ka tlase ho boleng bo tloaelehileng kapa ha ntlha ea ho qhala e eketseha ho fihlela litlhaloso tsa pele tse 2-3.
P: Ke hobane'ng ha ESL e tlase e le ea bohlokoa?
K: Ho kenella ha motlakase ka letoto le lekanang le tlase ho netefatsa ho sefa lerata le sebetsang ka katleho ka maqhubu a phahameng, e leng ntho ea bohlokoa bakeng sa phepelo ea motlakase ea sejoale-joale le li-inverter.
P: Na tsena li ka sebetsana le ho phahama ha motlakase?
K: E, theknoloji ea lifilimi tse ipholisang ka tšepe e iketsetsang e arola liphoso tse bakoang ke ho phahama ha motlakase ka bohona, e thibela lipotoloho tse khutšoane le ho lelefatsa bophelo ba tšebeletso.
Ikopanye Rona - Factop
Na u se u loketse ho ntlafatsa boleng ba hau ba matla ka litharollo tsa capacitor tsa maemo a profeshenale? Sehlopha sa rona sa botekgeniki se eme haufi ho u thusa ho khetha Capacitor e ntle ka ho fetisisa ea Sefahla sa Mokhahlelo o le Mong bakeng sa ts'ebeliso ea hau.
Ikopanye le rona kajeno bakeng sa litlhaloso tse qaqileng, litlhophiso tse ikhethileng, kapa lipuisano tsa tekheniki:
Imeile: serina@xaxd-electric.com
A re u thuseng ho fihlela ts'ebetso e phahameng ea ho lokisa matla ka litharollo tsa rona tsa capacitor tse tšepahalang le tsa boleng bo holimo.
romela dipatlisiso

_1794376693177.png)