Sehatsetsi sa potoloho sa sf6 se sebetsa joang?
2026-06-15 15:40:48
Ha mathata a hlaha ka motlakase oa gridi ea hau, o hloka tšireletso e ka sebetsang ka li-millisecond. Khase ea sebabole hexafluoride, e leng insulator e matla le arc-quencher, e sebelisoa ke SF6 Circuit Breaker ho emisa maqhubu a phoso ka mokhoa o sireletsehileng. Ha likhokahano li robeha, tlhase ea motlakase e hlaha pakeng tsa lipheletso. Khase ea SF6 e nang le li-electronegative tse ngata e nka lielektrone tse lokolohileng kapele ho tsoa arc, e pholisang kholomo ea plasma le ho tlosa li-ion tsa eona. Ka har'a li-millisecond tse 50, arc e tima ka botlalo, e khutlisa matla a dielectric le ho khaola sebaka se senyehileng. Ha e bapisoa le mahlale a khale, sesebelisoa sena sa ho sitisa khase e hatelletsoeng se na le sebaka se senyenyane, bokhoni bo betere ba ho roba, 'me se hloka tlhokomelo e nyane. Sena se etsa hore e be sesebelisoa sa bohlokoa bakeng sa lits'ebeletso, libaka tsa indasteri le li-substation tse laolang marang-rang a motlakase o mahareng ho isa ho o phahameng.
Ho Utloisisa Li-Circuit Breaker tsa SF6: Molao-motheo oa Mosebetsi le Likarolo tsa Moralo
Seqhomane sa Potoloho sa SF6 ke eng?
Matla a motlakase a khase ea sulfur hexafluoride a phahame ka makhetlo a ka bang 2.5 ho feta a moea khatellong e tloaelehileng. Ka lebaka la tšobotsi ena, baqapi ba ka etsa likamore tse nyane tsa interrupter tse lumellanang hantle le li-substation tsa kahare le kantle le li-switch. Lisebelisoa tse thehiloeng ho SF6 li tšepahala bakeng sa bophelo bohle, ho fapana le li-unit tse tletseng oli tse ka tukang kapa meralo ea makenete a moea e hlokang tlhokomelo e ngata. Khase ha e nke lehlakore ka lik'hemik'hale, ha e che, 'me ha e senye, kahoo e thibela likarolo tsa ka hare ho oxidize ka lilemo tse ngata tsa ts'ebeliso. Theknoloji ena e thusa bakeng sa lits'ebeletso tse tsamaisang marang-rang a phetisetso hobane e tlosa li-overvoltage tse thibelang tse lematsang li-transformer le libanka tsa capacitor.
Mohato-ka-Molao-motheo oa ho sebetsa
Motlakase o fosahetseng o qala li-relay tse sireletsang tse romelang lets'oao la leeto ho actuator ea CT14. Khokahano e tsamaeang e arohana le khokahano e tsitsitseng; hona joale e fetisetsoa ho likhokahano tse pota-potileng. Khatello e phahameng ea SF6 e pholisa kholomo ea arc ka puffer le katoloso ea mocheso. Limolek'hule tsa SF6 li hapa lielektrone tse lokolohileng, li qobella ho kopana hape ha li-ion. Matla a dielectric a hlaphoheloa kapele ho feta motlakase ho zero ea hona joale, a khaola matla ka botlalo ntle le ho shapa hape.
Likarolo Tse Bohlokoa tsa Moqapi
Di-interruptor tsa sejwalejwale di kenyeletsa setshwari sa ho ikopanya se tsitsitseng, kopano ya ho ikopanya e tsamayang, tanka ya puffer, le sebopeho sa tshehetso. Silindara ya kgase e kwaletsweng e nang le mehele ya O e boloka maemo a SF6. LW8-40.5 e na le di-gauge tsa density tsa MKZ tse sebetsanang le -30°C ho isa ho +55°C. Mokgwa wa selemo wa CT14 o fana ka matla a kgannang a sa kgaotseng ho feta mesebetsi e fetang 3,000. E loketse diphepelo tsa transformer le dibanka tsa capacitor.
Mefuta le Litšebeliso tsa Voltage
Bahlahisi ba etsa mefuta e fapaneng ea Li- SF6 Circuit Breaker tse etselitsoeng ho fihlela litlhoko tsa litsamaiso tse fapaneng. Meralo ea Li-SF6 Circuit Breaker tse robehileng ka le leng e ka sebetsana le maemo a fihlang ho 145 kV, ha meralo ea li-double-breaker e ka sireletsa marang-rang a fihlang ho 245 kV. Sebakeng sa 35 kV ho isa ho 72.5 kV, Li-SF6 Circuit Breaker tsa mofuta oa buffer ke tsona tse atileng haholo. Li ka emisa maqhubu a motlakase ka mokhoa o sireletsehileng ho tloha ho 1600A ho isa ho 3150A. Mefuta ea ho iphunya kapa ea katoloso ea mocheso e sebelisa matla a fokolang ho sebetsa, e leng se etsang hore e be molemo bakeng sa mesebetsi ea ho lokisa moo matla a lipotoloho tsa taolo ea hajoale a lekanyelitsoeng. Ha ho bapisoa le likhetho tse kenngoang ka moea, litsamaiso tsa switchgear tse kenngoang ka khase li kenya Li-SF6 Circuit Breaker tsa mekhahlelo e meraro ka har'a li-enclosure tse nyane, e leng se fokotsang boholo ba seteishene se senyenyane ka ho fihla ho 60%.
Melemo le Melemo e Sebetsang ea Li-SF6 Circuit Breaker bakeng sa Litsamaiso tsa Matla
Metrics ea Ts'ebetso e Phahameng
Ho theoha ha motlakase kapa di-harmonics ha di amohelehe libakeng tse sebedisang mechini ya CNC, ditsamaiso tsa UPS tsa setsi sa data, kapa disebediswa tsa tlhokomelo ya bohlokwa sepetlele. Theknoloji ya SF6 Circuit Breaker e na le dibopeho tse bonolo tsa ho fetola tse emisang ho phahama ha motlakase ha mojaro wa capacitive o sitiswa. Molemo ona o bontshwa ke SF6 Circuit Breaker ya mohlala wa LW8-40.5, e emisang maqhubu a phoso a 31.5 kA ka makgetlo a 21 ka tatellano ntle le ho hloka tokiso kapa ho tlatsa kgase. Ka hara di-microsecond, dielectric e a fola, e etsa bonnete ba hore SF6 Circuit Breaker e ka sebetsana le ho phahama ho bakwang ke lehalima le di-transient tse fetohang tse tlwaelehileng diteisheneng tse nyane bakeng sa matla a matala. Boholo bo bonyenyane ba SF6 Circuit Breaker bo fokotsa bolelele ba busbar le khanyetso ya kgokelo, e leng se fokotsang ho theoha ha motlakase mme se etsa hore boleng ba motlakase bo be betere bakeng sa di-elektroniki tse utlwahalang.
Ha melaoana lefatšeng ka bophara e ntse e thatafala, liqeto tsa hore na u reke eng li angoa ke matšoenyeho a tikoloho le polokeho. Hobane khase ea SF6 e ka futhumatsa polanete ka makhetlo a 23,500 ho feta CO2, lik'hamphani li sebetsa ka thata ho e thibela ho lutla. Sekhahla sa ho lutla ha khase lits'ebetsong tsa khatello tse koetsoeng tsa sejoale-joale se tlase haholo ho feta tsa meralo ea khale, ka tlase ho 0.5% ka selemo. Ho tjhaja esale pele fekthering ho felisa tlhoko ea ho sebetsana le khase e kholo sebakeng seo, e leng se fokotsang likotsi tsa ho romelloa ha thepa le ho etsa hore ho kenngoa ho be bonolo. Litsamaiso tsa ho latela khase e ngata li u tsebisa esale pele ha khatello e theoha, ho bolelang hore u ka rera ho lokisa ho e-na le ho tlameha ho tima maemong a tšohanyetso. Litsebi tse qhaqhang lisebelisoa tsa khale li ka sebelisa lipompo tsa vacuum tse nkehang habobebe ho bokella le ho sebelisa SF6 hape, e leng se e thibelang ho lokolloa moeeng.
Tlhahlobo ea Bophelo le Kakaretso ea Litšenyehelo
Ha basebetsi ba theko ba sheba matsete a nako e telele, ba nahana ka hore na mochini o tla nka nako e kae le hore na o tla hloka ho nkeloa sebaka hangata hakae. Li-breaker tsa boleng bo botle tse fihlelang maemo a IEC 62271-100 li ka sebetsana le lits'ebetso tsa mechini tse 10,000 mme li na le sehlopha sa mamello ea motlakase sa E2. Ha li bapisoa le likhetho tsa makenete a moea, litšenyehelo tsa tlhokomelo ea selemo le selemo li tlase ka 40% hobane liphetoho tsa oli, ho nkeloa sebaka ha ntlha ea ho kopana le bona, le tšebeletso ea dehumidifier ha li hlokahale. Setsi sa data sa Texas se ile sa tlosa li-breaker tsa khale tsa oli 'me sa li nkela sebaka ka li-unit tsa SF6. Sena se ile sa felisa tlhoko ea licheke likhoeli tse ling le tse ling tse tharo 'me sa eketsa nako pakeng tsa lits'ebeletso ho tloha lilemong tse peli ho isa ho lilemo tse tšeletseng. Moralo o koetsoeng o thibela lerōle, metsi le likhase tse senyang, kahoo li ka sebelisoa libakeng tsa lebōpo la leoatle le libakeng tse boima tsa indasteri ntle le hore khetla e hlolehe. Balaoli ba lits'ebeletso ba kenyelletsa litšenyehelo tsa nako ea ho se sebetse e qojoang litšenyehelong tsohle tsa beng. Ka har'a semiconductor fab, tahlehelo e le 'ngoe e sa lebelloang e ka bitsa chelete e fetang $2 milione tlhahisong e lahlehileng.
Malebela a ho Tharolla Mathata le Tlhokomelo bakeng sa Li-SF6 Circuit Breakers
Ho Fumana Mefokolo e Tloaelehileng
Mekhoa ea tlhahlobo e hlophisitsoeng e fumanang hore e senyeha pele e etsahala ea hlokahala bakeng sa ts'ebetso e tšepahalang. Ha khatello ea SF6 Circuit Breaker e theoha ka tlase ho 90% ea boemo bo tloaelehileng, lialamo tsa khatello ea khase lia lla. Sena se bolela hore ho na le ho lutla ha li-flange joints kapa li-valve seal. Ho fumana libaka tsa ho baleha, litsebi li sebelisa lisebelisoa tse tšoaroang ka letsoho. Nakong ea nako e reriloeng ea ho phomola, li ntan'o fetola linate tsa torque kapa li nkela li-gasket sebaka. Ha mochine o hloleha, hangata o hlaha e le ts'ebetso e liehang kapa motsamao o sa phethoang. Lisebelisoa tsa nako tse sebelisoang ho lekanya lebelo la ho koala le ho bula li bontša hore actuator ea CT14 e na le li-spring tse senyehileng kapa khatello e tlase ea hydraulic. Nakong ea tlhokomelo ea selemo le selemo, tlhahlobo ea khanyetso ea ho kopana e fumana khoholeho ea mobu kapa tšilafalo e etsang hore tlhahiso ea mocheso e eketsehe. Boleng bo holimo ho 500 microhms bo bolela hore li-contact li hloka ho hloekisoa kapa ho nkeloa sebaka.
Liteko tse bonahalang le tlhahisoleseding e tswang disebedisweng ke karolo ya ditlhahlobo tsa paterole. Basebedisi ba etsa bonnete ba hore mela e hodima tekanyo ya density gauge e dula sebakeng se setala le hore dipontsho tsa phanele ya taolo di bontsha boemo bo nepahetseng ba di-breaker. Jwalo ka karolo ya diteko tsa kgwedi le kgwedi, dikgokelo tsa mochine le dithupa tsa ho kganna di tlotswa ka oli ho emisa kgohlano e senyang matla. Ho tiisa diboutu tsa ankora, ho hlahloba di-valve, le ho tlosa condensate matlong a mochine ke dintho tsohle tse hlokang ho etswa hang ka selemo. Diketsahalo tse thathamisitsweng ka tlase di hlophisitswe tafoleng e ka tlase.
Melao ea Tlhahlobo:
- Tlhokomelo ea Khatello ea Khase: Ho hlahloba letsatsi le leng le le leng ho thibela ho lutla ha metsi ho bokellana ntle le ho hlokomeloa; ho nkela li-monitor sebaka tseo palo ea tsona e fetohileng ka ho feta 2%
- Tlhahlobo ea Khokahano ea Mechini: Ho tlotsa hang ka khoeli ho eketsa bophelo ba ho behela 'me ho fokotsa ho senyeha ha ho kopana; mafura a thehiloeng ho graphite a ka sebetsana le mocheso o phahameng
- Teko ea Motlakase: Selemo se seng le se seng, liteko tsa ho mamella motlakase o phahameng li etsoa ho netefatsa hore ho kenya mocheso ho ntse ho le molemo, 'me khanyetso ea ho kopana le motlakase o phahameng e lekanngoa ho fumana matšoao a ho tsofala le ho taboha.
Ho Khetha Balekane ba Litšebeletso le Likarolo
Barekisi ba lumelletsoeng ba na le litsebi tse rutiloeng ke moetsi 'me ba tloaelane le mefuta e itseng ea li-breaker. Ba jara likarolo tsa mantlha tse entsoeng ka hloko ho sebetsa le sistimi ea mantlha. Ka tsela ena, ha ho na mathata a ho lumellana a ka felisang litiisetso. Likarolo tsa motho oa boraro li kanna tsa se ke tsa etsoa ka thepa e ntle, joalo ka li-alloy tsa koporo ho fapana le likhokahano tsa silevera-tungsten, e leng se fokotsang bokhoni ba tsona ba ho emisa le ho khutsufatsa bophelo ba tsona. Batsamaisi ba theko ba etsa bonnete ba hore bafani ba litšebeletso ba na le inshorense e lekaneng 'me ba latela lits'ebetso tsa ho koala le ho tagout tsa OSHA ha ba buisana ka likonteraka tsa litšebeletso. Ka ho sebelisa li-sensor tsa ho thothomela le lik'hamera tsa ho nka litšoantšo tsa mocheso, mananeo a tlhokomelo ea esale pele a fumana mathata likhoeli pele a etsahala. Sena se lumella litokiso ho etsahala nakong ea likhefu tse reriloeng ho fapana le ho tlameha ho etsoa kapele maemong a tšohanyetso.
Ho Bapisa Li-SF6 Circuit Breakers le Mekhoa e Meng ea Theknoloji
Litšebelisano tsa Tshebetso le Tikoloho
Mmaraka oa 12 kV ho isa ho 38 kV o laoloa ke li-vacuum circuit breaker, tse sa lokolleng likhase tse futhumatsang lefatše 'me li nyane. Li sebetsa hantle lits'ebetsong tse hlokang ho sebelisoa khafetsa, joalo ka ho qala ha motlakase, empa ha li sebetse hantle ka ho fetola capacitive hobane li baka li-overvoltage tse senyang sekoahelo holim'a likhoele. Meralo ea ho phatloha ha moea, e tsebahalang haholo litlhophisong tsa khale, e hloka li-compressor le li-air dryer, tse sebelisang matla a mangata 'me li etsa hore tlhokomelo e be thata le ho feta. Li-oil circuit breaker li ntse li sebelisoa lifemeng tsa motlakase oa metsi mahaeng moo litšenyehelo tsa ho nkela SF6 Circuit Breaker sebaka li phahameng ho feta melemo ea ntlafatso. Leha ho le joalo, matšoenyeho mabapi le polokeho ea mollo le tšenyo ea tikoloho li li sutumelletsa ho tsoa tšebeletsong. Ho tšoana ho bohlokoa ho bontšitsoe tafoleng e ka tlase.
Matrix ea Papiso ea Theknoloji:
- Diyuniti tsa SF6: Diyuniti tsa SF6 di ka kgaoha ho fihla ho 63 kA, di hloka ho lokiswa dilemo tse ding le tse ding tse 6, mme di nka sebaka se ka tlase ho 40% ho feta diyuniti tsa ho phatloha ha moya; di loketse diteishene tse nyane tsa phetisetso le dibanka tsa capacitor.
- Li-Vacuum Breaker: Li-Vacuum Breaker ha li fane ka tšilafalo efe kapa efe 'me li ka sebetsana le matla a fihlang ho 40.5 kV; li sebetsa hantle methating ea kabo le litsing tsa taolo ea likoloi tsa indasteri.
- Matla a Moea: Litšenyehelo tse tlase tsa ho qala; e hloka ho sebeletsoa hang ka selemo; e na le sebaka se seholo; e loketse lihlopha tsa mahaeng tse nang le lichelete tse fokolang
Dikgetho tse ntjha tse sa sebediseng SF6 di kopanya moya o hlwekileng kapa fluonitrile ho fumana boemo bo tshwanang ba matla a motlakase. Dikhamphani tse batlang ho rekisa thepa ya tsona Europe jwale di na le disebediswa tsa 24 kV tse sebedisang kgase ya g³, e leng monyetla o tlase ka 99% wa ho baka ho futhumala ha lefatshe. Ho itokisa ha tekheniki ho ntse ho ntlafala, empa ditjeo tse hodimo le ho hloka boiphihlelo ba tshimo ho etsa hore ho nke nako e telele hore mebaraka e nang le ditheko tse tlase e amohelehe. Ditshebeletso tse rerang hore disebediswa di dule dilemo tse 20 di ntse di shebile diphetoho tsena ha di ntse di tswela pele ho sebedisa theknoloji ya SF6 e lekilweng le ya nnete e nang le mekgwa e betere ya ho fumana ho dutla le ho laola kgase.
Tataiso ea Theko: Mokhoa oa ho Khetha le ho Reka Sekhahla se Nepahetseng sa Potoloho sa SF6?
Ho Hlalosa Litlhoko tsa Morero
Ho hlalosa sistimi ka nepo ke mohato oa pele oa ho reka ka katleho. Ho fihlela litlhoko tsa breaker, baenjiniere ba ngola motlakase o phahameng ka ho fetisisa, maemo a hona joale a nang le bothata, le maqhubu a ho chencha. Setsi sa 35 kV se fanang ka mochini oa tšepe se hloka sesebelisoa se ka sebetsanang le motlakase o moholo ka ho fetisisa oa sistimi oa 40.5 kV, se na le bokhoni ba potoloho e khuts'oane ea 31.5 kA, 'me se na le sehlopha sa mamello ea mechini sa M2. Mabaka a mang a tikoloho ke bophahamo, mocheso o phahameng, libaka tsa litšisinyeho tsa lefatše, le bongata ba litšila. Ka li-enclosures tse lekantsoeng ke IP65, tšireletso ea litšisinyeho tsa lefatše ho fihlela matla a 9, le liphahlo tse sa senyeheng mafome bakeng sa libaka tsa lebōpo la leoatle, mofuta oa kantle oa LW8-40.5 o ka sebetsana le maemo ana.
Tlhahlobo ea Mofani le Letšoao
Likhamphani tse bileng teng ka nakoana li boloka litsamaiso tsa tsona tsa boleng li amoheloa ho latela maemo a ISO 9001 le a tikoloho joalo ka ISO 14001. Bakeng sa li-switchgear tse nang le motlakase o phahameng, lihlopha tsa theko li sheba liphetho tsa liteko tse bontšang tumellano le IEC 62271-100, 'me bakeng sa limmaraka tsa Chaena, li sheba GB/T 11022. Bahlahisi ba fanang ka liwaranti tse nkang nako e fetang lilemo tse peli ba kholisehile ka botsitso ba lihlahisoa tsa bona. Tšehetso ea kamora thekiso e kenyelletsa thuso ea litsebi lihora tse 24 ka letsatsi, matsatsi a supileng ka beke, likarolo tse ling tse ka romelloang nakong ea lihora tse 72, le mananeo a koetliso bakeng sa basebetsi ba tlhokomelo. Ka boiphihlelo ba lilemo tse fetang 20 litsamaisong tsa kabo ea motlakase, Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. ke mohlala o motle oa litšobotsi tsena. Yuniti e 'ngoe le e 'ngoe e tlohang lifekthering tsa rona tse netefalitsoeng ke ISO e feta mekhahlelong e 12 ea liteko tsa boleng, 'me likarolo tse kang mokhoa oa CT14 li kenngoa lipotolohong tse 10,000 tsa liteko tsa mamello. Lihlahisoa li sebelisoa ke litsamaiso tsa State Grid, marangrang a lipalangoang tsa literene, le lifeme tsa petrochemical tse sebetsang maemong a fapaneng a mocheso le maemo.
Maano a Theko le Tsamaiso ea ho Laela
Litheko tsa 'maraka lia fetoha ho latela bothata ba moralo le palo ea liodara. Lintho tse tloaelehileng tsa khataloge li romeloa ka libeke tse 'ne, empa linako tsa ho leta li ka ba libeke tse robeli bakeng sa litlhophiso tse ikhethileng joalo ka li-transformer tsa hajoale tse kopantsoeng kapa li-bracket tse khethehileng tsa ho kenya. Ha u reka li-unit tse fetang leshome ka nako e le 'ngoe, u ka fumana polokelo le libaka tsa tlhahiso ea pele. Ha batsamaisi ba theko ba fana ka litlhoko tse felletseng tsa tekheniki qalong ea ts'ebetso ea ho qotsa, barekisi ba ka ntlafatsa meralo le litheko tse tlase, e leng se fang batsamaisi ba theko matla a mangata a ho buisana. Ha lik'hamphani tsa EPC li sebetsa 'moho le OEM mererong e meholo ea li-substation, li ka fana ka thepa e kopantsoeng le mabitso a nang le likarolo tse ikhethileng ho moreki. Lipehelo tsa tefo hangata li kenyelletsa tefo ea pele ea 30%, 60% pele ho romelloa, le 10% e bolokiloeng ho fihlela mosebetsi o felile. Ho kopa tlhahlobo ea kamohelo ea fektheri pele ho romelloa ho etsa bonnete ba hore sehlahisoa sea sebetsa 'me ho fokotsa tieho sebakeng sa marang-rang nakong ea ho seta.
fihlela qeto e
Basebetsi ba phumantsho ba ka kgetha dikgetho tse ntle ka ho fetisisa bakeng sa marangrang a phetiso le kabo ha ba tseba kamoo SF6 Circuit Breakers e emisang maqhubu a phoso ka ho tima arc ea khase-blast. Theknoloji ena e rarolla mathata a maholo ao lits'ebeletso tsa motlakase, libaka tsa indasteri le lik'hamphani tsa EPC li tobanang le 'ona ka matla a eona a phahameng a dielectric, boholo bo bonyenyane, le litlhoko tse tlase tsa tlhokomelo. Likhase tse ling li ntse li ithutoa hobane li betere bakeng sa tikoloho, empa litsamaiso tsa hona joale tse sebelisang SF6 li bontšitsoe li sebetsa ka mokhoa o tšepahalang ha li sebetsoa hantle. Katleho ea nako e telele e sebetsang le tsamaiso ea thepa e theko e tlaase li tiisetsoa ka ho hlahloba bafani ho latela mangolo a bona a netefatso, lipehelo tsa waranti, le tsebo ea tšehetso ea litsebi.
LBH
1. Khatello ea khase ea SF6 e lokela ho hlahlojoa hangata hakae?
Letsatsi le leng le le leng, nakong ea ts'ireletso, litekanyo tsa khatello li shejoa ka mahlo ho fumana ho theoha ha khatello ka tšohanyetso ho bolelang hore ho na le ho lutla. Lipalo tse rekotiloeng khoeli le khoeli li boloka tlaleho ea liphetoho tse nyane, 'me ha boleng bo theoha ka 5% ka tlase ho karolelano, li qala lipatlisiso. Lisebelisoa tsa ho beha leihlo li lekanngoa hang ka selemo ho boloka ho nepahala ha data ka har'a moeli oa 2%.
2. Na di-breaker tsa SF6 di ka sebetsa dibakeng tse phahameng?
Meralo e tloaelehileng e sebetsa ka katleho ho fihlela boemong ba limithara tse 1,000. Lisebelisoa tse nang le tekanyo ea Plateau li na le litsamaiso tse betere tsa ho thibela mocheso le tsa ho sebetsa tse lokisitsoeng bakeng sa libaka tse fihlang ho limithara tse 4,000, moo ho ba le moea o fokolang ho amang libaka tse bulehileng le ho pholisa.
3. Ke eng e etsang hore li-breaker tsa SF6 li lahleheloe ke ho kopana ha tsona?
Ho qhibilihisa marako khafetsa ho qhibilihisa thepa ea ho kopana, 'me sekhahla sa khoholeho se amana le boholo le makhetlo a phallo e robehileng. Litšepe tsa silevera-tungsten li nka nako e telele ho feta koporo hobane ha li senyehe kapele. Ka bokhoni ba tsona bo lekantsoeng, li ka mamella tieho ea liphoso tse 100. Ha tlhokomelo e etsoa ka linako tse nepahetseng, likhokahano li lokela ho nkeloa sebaka pele maemo a khanyetso a phahama 'me a ama ts'ebetso.
Sebelisana le Xi'an Xikai bakeng sa Litharollo tse Tšepahalang tsa SF6 Circuit Breaker
Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. ke k'hamphani e tšepahalang e etsang SF6 Circuit Breakers bakeng sa merero ea meralo ea motheo ea motlakase e batloang haholo lefatšeng ka bophara. Ho boloka lintho tsa hau tsa bohlokoa li sireletsehile, mohlala oa rona oa kantle oa LW8-40.5 o na le moralo o lumellanang le IEC, ho latela khase e ntlafalitsoeng, le mokhoa o tšepahalang oa CT14. Re fana ka litharollo tse ikhethileng tse tšehelitsoeng ke setifikeiti sa ISO 9001 le tšehetso e felletseng ea litsebi. Re ka etsa mefuta e supileng ea lihlahisoa le mefuta e fetang 100 ea lihlahisoa tseo. Romela lengolo-tsoibila ho serina@xaxd-electric.com , amber@xaxd-electric.com , kapa luna@xaxd-electric.com ho bua ka litlhoko tsa projeke ea hau le ho fumana lintlha tse felletseng tse etselitsoeng ho lekana motlakase oa hau, bokhoni le tikoloho ea hau.
References
1. Tekanyetso ea IEEE C37.122-2010, "Tekanyetso ea IEEE bakeng sa Liteishene tse Nyane tse Sirelelitsoeng ka Khase tse Lekantsoeng ka Holimo ho 52 kV," Setsi sa Baenjiniere ba Motlakase le Elektroniki, 2010.
2. IEC 62271-100:2021, "Sesebelisoa sa ho fetola motlakase se nang le motlakase o phahameng le lisebelisoa tsa taolo – Karolo ea 100: Li-circuit-breaker tse fetolang motlakase," Khomishene ea Machaba ea Electrotechnical, 2021.
3. Kapila, R. le Singh, A., "Tsoelo-pele ho Theknoloji ea SF6 Circuit Breaker bakeng sa Mekhoa ea Motlakase ea Kajeno," Journal of Power Engineering, vol. 45, no. 3, maq. 112-128, 2019.
4. Mokhatlo oa Naha oa Bahlahisi ba Motlakase, "Tataiso ea Kopo bakeng sa Li-breaker tsa Potoloho ea Motlakase o Phahameng oa AC tse Lekantsoeng ho latela Motheo oa Hona Joale o Tšoanang," NEMA SG 4-2020, 2020.
5. Telander, M., "Taolo ea Khase ea SF6: Mekhoa e Molemohali bakeng sa Litšebeletso," Makasine oa Lefatše oa Phetisetso le Kabo, vol. 72, no. 8, maq. 34-42, 2020.
6. Zhang, L., Chen, W., le Liu, Y., "Tlhahlobo ea Papiso ea Theknoloji ea ho Fetoha ha Motlakase o Bohareng: SF6, Vacuum, le Mekhoa e Meng e Hlahang," Seboka sa Machaba sa Litsamaiso tsa Theknoloji ea Sistimi ea Matla, maq. 567-574, 2021.