banka e bohlale ea capacitor
2. Fokotsa tahlehelo ea marang-rang, bokhoni bo phahameng le poloko ea matla;
3. Laola li-harmoniki tsa sistimi kapa li-harmoniki tsa taolo ho latela litlhoko tsa mosebelisi;
4. Fokotsa motlakase o arabelang, boloka litšenyehelo tsa bokhoni ba transformer, ntlafatsa tlhahiso ea transformer.
5. Taolo ea bohlokoa ba motlakase, mosebetsi oa taolo ea motlakase oa capacitor o ka sebelisoa ho ntlafatsa sekhahla sa ho feta ha motlakase.
- Phano e potlakileng
- boleng tiisetsa
- Tšebeletso ea Bareki ea 24/7
Product Introduction
Smart Capacitor Bank - Tharollo e Tsoetseng Pele ea Tokiso ea Matla
Product Introduction
Natefeloa ke bokamoso ba puseletso ea matla a arabelang ka theknoloji ea rona ea banka ea capacitor e bohlale e tsoetseng pele . E etselitsoe ka ho khetheha lits'ebetso tsa sejoale-joale tsa indasteri, tharollo ena e ncha e fetola tokiso ea matla a setso hore e be sistimi e bohlale, e feto-fetohang e lumellanang le litlhoko tsa hau tsa motlakase tse fetohang. Banka ea rona ea capacitor e bohlale e kopanya theknoloji e tsoetseng pele ea ho fetola ho se tšele, bokhoni ba ho lekola nako ea sebele, le lipotoloho tsa tšireletso ea ho iphekola ho yuniti e le 'ngoe, e nyane.
Hore na o laola meroalo e boima ea ho kenya tšebetsong litsing tsa tlhahiso kapa o ntlafatsa boleng ba motlakase litsing tsa data, sistimi ea rona e bohlale ea puseletso e fana ka taolo e nepahetseng ea matla a arabelang ha o ntse o felisa ho rarahana ha likhabote tsa puseletso tsa setso. Mokhoa ona o mocha oa ho lokisa lintlha tsa motlakase o u thusa ho fokotsa litšenyehelo tsa matla, ho ntlafatsa ts'ebetso ea sistimi, le ho boloka boleng bo botle ba motlakase ho pholletsa le meralo ea hau eohle ea motlakase.
Technical tobileng
| paramethara | latela boleng ba |
|---|---|
| Rated gagamalo | 415V/480V (3-phase, 50/60Hz) |
| Sebaka sa Matla a Ikarabellang | 5kvar - 50kvar ka mojule |
| Theknoloji ea ho fetoha | Thyristor e tšelang lefela + relay ea ho latching ea makenete |
| e le karabelo ea Nako | <20ms (meroalo e matla) |
| le be le Puisano | Modbus-RTU, RS-485 |
| bueloang Mocheso | -25 ° C ho + 55 ° C |
| Ts'ireletso ea Ts'ireletso | IP20 (e tloaelehileng), IP54 (e fumaneha) |
| Tahlehelo ea Dielectric | <0.1% ka motlakase o lekantsoeng |
| Bokhoni ba ho Fetela ho Feteletseng | 1.3 × E tswela pele |
| Overvoltage Tolerance | 1.1 × E sa tswelang pele |
| Bophelo ba Tšebeletso | Mesebetsi ea ho fetola e fetang 100,000 |
| Litekanyo (ka mojule) | 140mm × 76mm × 160mm |
Lintlha Tse ka Sehloohong le Melemo
Theknoloji ea ho Fetola ka ho se Tšele
E felisa maqhubu a kotsi a kenang a atisang ho fihla makhetlo a 100 ho feta motlakase o lekantsoeng litsamaisong tsa setso. Mokhoa ona o tsoetseng pele oa ho fetola o atolosa bophelo ba lisebelisoa haholo.
Modular Design Architecture
Dimojule tse ka fetolwang ka mocheso di dumella diphetoho tsa bokgoni ntle le ho tima ha sistimi. Kenya kapa tlosa diyuniti tsa puseletso ha o ntse o boloka tshebetso e tswelang pele.
Taolo ea Marang-rang e Bohlale
Tlhophiso e iketsahallang ya master-slave ka tshireletso e sa feleng ya ho hloleha. Ha yuniti e kgolo e hloleha, yuniti ya slave e nka taolo ka ho hlaka ka metsotswana.
Tlhahlobo ea Nako ea Sebele
Tlhokomelo e tsoelang pele ea motlakase, hona joale, mocheso le ho sotha ha harmonic ka litsebiso tsa alamo tse potlakileng le ho itšehla thajana ka boiketsetso.
Tšireletso e lumellanang
Mefuta e ikhethileng ea anti-harmonic e kopanya li-reactor tse se nang molumo (7% kapa 14% impedance) ho thibela ho thothomela ha molumo libakeng tse phahameng tsa THD.
Liketso tse sebetsang
Tlhahiso e boima ea indasteri
E loketse hantle bakeng sa lifeme tsa likoloi le libaka tsa tšepe moo liroboto tsa ho tjheseletsa le lienjene tse boima li bakang litlhoko tse kholo tsa matla a arabelang. Moralo o hanelang harmonic o sebetsana le tšitiso ea VFD ka katleho.
Litsi tsa Lintlha le Libaka tsa Li-server
Sebaka se senyenyane se lekana hantle libakeng tse fokolang ha sesebelisoa sa ho fetola motlakase se sa tšele letho se felisa tšitiso ea motlakase e ka sitisang lisebelisoa tsa IT tse bonolo.
Kopanyo ea Matla a Tsosolositsoeng
E fana ka botsitso ba motlakase ba bohlokoa le tšehetso ea matla bakeng sa mapolasi a letsatsi le a moea, e ntlafatsa kopanyo ea gridi le ho fokotsa tahlehelo ea phetisetso.
How It Works
Banka ea hau ea capacitor e bohlale e lula e lekola liparamente tsa motlakase ka li-sensor tse kopantsoeng. Molaoli ea bohlale o bala litlhoko tse ntle tsa puseletso mme o kenya tšebetsong motsoako o nepahetseng oa li-module tsa capacitor tse hlokahalang.
Theknoloji ea ho fetola ka lefela e sebelisa li-capacitor hantle ha phapang ea motlakase e lekana le lefela, e thibela ho senya maqhubu a ho kena ha motlakase. Li-sensor tsa mocheso oa kahare li baka lifene tse pholileng kapa ho khaoloa ka boiketsetso haeba meeli ea mocheso e feta.
Diyuniti tse ngata di buisana ka protocol ya Modbus, ho arolelana tlhahisoleseding ya mojaro le ho hokahanya dikarabo. Mokgwa ona o hokahantsweng o netefatsa puseletso e leka-lekaneng setsing sohle sa hao.
Bokhabane ba Tlhahiso
Xi'an Xidian Medium and Low Voltage Electric Co., Ltd. e tlisa boiphihlelo ba mashome a lilemo ba kabo ea matla ho yuniti e 'ngoe le e 'ngoe eo re e etsang. Li-portfolio tsa rona tse felletseng tsa lihlahisoa li akaretsa lihlopha tse 9 tse nang le mefuta e fetang 100, motlakase o sebeletsang o tloha ho 0.4kV ho isa ho 40.5kV.
Re boloka taolo ea boleng ba ISO9001, taolo ea tikoloho ea ISO14001, le litifikeiti tsa polokeho tsa OHSAS18001. Lihlahisoa tsa rona tse phahameng li sebetsa ka mokhoa o tšepahalang libakeng tse fetang limithara tse 4000.
Banka e 'ngoe le e 'ngoe ea capacitor e bohlale e feta litekong tse matla ho fihlela maemo a naha le a indasteri, ho netefatsa ts'ebetso e tšepahalang libakeng tse hlokang boiteko bo bongata.
Lebaka Leo re Lokelang ho le Khetha
Rekoto ea Pina e Pakiloeng
Phihlelo ea rona e pharaletseng ea lisebelisoa tsa motlakase o mahareng le o tlase e fetolela botšepehi le ts'ebetso e phahameng ea sehlahisoa.
Kakaretso Tharollo
Ntle le dihlahiswa ka bomong, re fana ka ditshebeletso tse felletseng tsa kopanyo ya sistimi tse etseditsweng ditlhoko tsa hao tse ikgethang tsa kabo ya matla.
Tlhahiso ea Teknoloji
Matsete a tswelang pele dipatlisisong le ntshetsopeleng a boloka theknoloji ya rona e le ka pele ho tswelopele ya indasteri.
Customer Support
Lihlopha tse inehetseng tsa botekgeniki li fana ka boeletsi ba litsebi, tataiso ea ho kenya, le tšehetso e tsoelang pele ea tlhokomelo.
LBH
P: Na di-module tse fapaneng tsa bokgoni di ka sebetsa mmoho tsamaisong e le nngwe?
K: E, sistimi ea rona ea taolo e bohlale e lemoha bokhoni ba mojule ka mong ka bo eona 'me e ntlafatsa metsoako ea ho fetola bakeng sa puseletso e nepahetseng.
P: Ho etsahala'ng nakong ea libaka tse nang le harmonic e ngata?
K: Re fana ka mehlala e khethehileng ea anti-harmonic e nang le li-reactor tse kopaneng tse sireletsang khahlanong le molumo maemong a phahameng a THD.
P: Hangata litsamaiso tsena li nka nako e kae?
K: Theknoloji ea ho fetola likhoerekhoere e atolosa nako ea bophelo ho fihlela ho lilemo tse 8-10 ha e bapisoa le lilemo tse 1-2 bakeng sa likhoerekhoere tsa setso.
P: Na ho fapanyetsana ka ho chesa hoa khoneha?
K: Ehlile. Moralo oa rona oa modular o lumella ho eketsa kapa ho tlosa li-unit nakong ea ts'ebetso ntle le ho tima sistimi.
Ikopanye Rona - Factop
Na u se u loketse ho ntlafatsa tokiso ea hau ea matla ka litharollo tsa rona tse tsoetseng pele tsa banka ea capacitor e bohlale? Litsebi tsa rona tsa botekgeniki li eme ho buisana ka litlhoko tsa hau tse ikhethileng le ho fana ka likhothaletso tse ikhethileng.
Imeile: serina@xaxd-electric.com
A re u thuseng ho fetola ts'ebetso ea sistimi ea hau ea motlakase ha re ntse re fokotsa litšenyehelo tsa ts'ebetso le ho ntlafatsa boleng ba motlakase setsing sa hau.
romela dipatlisiso




