sehlahisoaPic

Motlakase oa Filimi oa 10KV

1.Maqhubu a 60Hz.
2. Ho kheloha ha Capacitance -5% ~ + 10%.
3.Motlakase o Moholo wa Hona Jwale 2.5×In.
E hlomelitsoe ka li-resistor tse ntšang motlakase 4. E kopantsoe le lisebelisoa tse ikemetseng tsa tšireletso ea motlakase o feteletseng.
5.Ts'ebetso e phahameng ea ho ipholisa le bophelo bo bolelele ba tšebeletso.
6.Moralo oa mofuta o omileng, o nang le sebopeho se se nang ho dutla ha metsi.
7. E hlomelloa ka li-resistor tse ntšang metsi.
  • Phano e potlakileng
  • boleng tiisetsa
  • Tšebeletso ea Bareki ea 24/7

Product Introduction

Mochini oa Filimi oa 10KV - Litharollo tsa Matla a Ts'ebetso e Phahameng

Product Introduction

Ha o hloka kabo e tšepahalang ea matla ho li-volt tse 10,000, 10KV Film Capacitor ea rona e fana ka ts'ebetso e ikhethang bakeng sa lits'ebetso tsa hau tse hlokang boiteko bo boholo. Li-capacitor tsena tse tsoetseng pele li etselitsoe ka ho khetheha litsamaiso tsa motlakase o mahareng moo ts'epo e ke keng ea senyeha. Li hahiloe ka theknoloji ea filimi ea polypropylene ea boleng bo holimo, li fana ka ts'ebetso e ntle ea motlakase le ho tšoarella nako e telele hoo ts'ebetso ea hau e itšetlehileng ka hona.

Li-capacitor tsa rona tsa filimi li na le li-resistor tse kopantsoeng tsa ho ntša metsi bakeng sa polokeho e ntlafalitsoeng. Li tla le lisebelisoa tse ikemetseng tsa tšireletso ea over-voltage tse hahiloeng ka hare. U fumana ts'ebetso e phahameng ea ho ipholisa e atolosang bophelo ba ts'ebeletso haholo. Moralo oa mofuta o omileng o felisa matšoenyeho a ho lutla ka botlalo. Habohlokoa le ho feta, u rua molemo ho ntlha e tlase haholo ea tahlehelo e eketsang ts'ebetso ea sistimi.

Technical tobileng

paramethara ga tlhaloso
Rated gagamalo 10kV
maqhubu 50 / 60Hz
Ho kheloha bokhoni -5% ho ea ho +10%
Boholo ba ha joale 2.5 × Ka hare
Sehlahisoa sa Dissipation (tan δ) <0.0005 ho 1kHz
Ho hanyetsa ho kenya letsoho > 30,000 MΩ
bueloang Mocheso -40 ° C ho + 85 ° C
Lisebelisoa tsa Dielectric Polypropylene (PP) Filimi
Encapsulation Resin ea epoxy e thibelang malakabe
Ts'ireletso ea Ts'ireletso UL94 V-0
Ho Sebetsana le ho Hatela ha Pelo Ho fihlela ho 1000V/µs

Lintlha Tse ka Sehloohong le Melemo

Theknoloji ea Boipheliso

Sistimi ea hau e lula e sebetsa esita le ka mor'a ho phahama ha motlakase. Ha motlakase o feteletseng o hlaha, theknoloji ea rona ea lifilimi tse entsoeng ka tšepe e arola liphoso ka bo eona 'me e tsosolosa ts'ebetso.

Ntlha ea Tahlehelo e Tlase ka ho Fetisisa

O boloka litšenyehelo tsa eneji ka tlhahiso e fokolang ea mocheso nakong ea ts'ebetso. Kaho e tsoetseng pele ea polypropylene e fana ka katleho e etelletseng pele indastering.

Kaho e Matla

E hahiloe ho mamella tikoloho e thata ea indasteri. Epoxy e thibelang malakabe e sireletsa khahlanong le mongobo 'me e thibela ho thula ha maqhubu a kotsi.

Bokhoni bo Phahameng ba ho Pulsa

Sebetsana le liphetoho tse potlakileng tsa motlakase ka kholiseho. Tšepe e boima e mamella liphetoho tse fetohang tse ka senyang li-capacitor tse tloaelehileng.

Liketso tse sebetsang

Tsamaiso ea Tsamaiso ea Matla

U tla fumana li-capacitor tsa rona tsa motlakase o phahameng li hlokahala libankeng tsa switchgear tsa motlakase o mahareng le tsa tokiso ea matla. Li thusa ho boloka botsitso ba gridi le ho fokotsa likotlo tsa motlakase tse arabelang.

Lisebelisoa tsa indasteri

E loketse bakeng sa di-drive tsa enjene, disebediswa tsa ho tjheseletsa, le mechini e boima moo tshebetso e tshepahalang ya 10KV Film Capacitor e leng ya bohlokwa bakeng sa tshebetso e tswelang pele.

Thepa ea Bongaka le Saense

Tšepa li-capacitor tsa rona mechineng ea X-ray, li-scanner tsa CT, le lisebelisoa tsa laboratori moo ho nepahala le polokeho li leng tsa bohlokoa.

Mekhoa ea Matla a Tsosolositsoeng

Tšehetsa liturbine tsa moea le li-inverter tsa letsatsi tse nang le puseletso e tsitsitseng ea matla a arabelang le taolo ea motlakase.

How It Works

Sesebediswa sa Filimi sa 10KV se sebetsa ka melao-motheo e tsoetseng pele ya dielectric. Mealo e mengata ya filimi ya polypropylene e etsa mokoallo o matla wa motlakase. Ha kgatello ya motlakase e hlaha, lesela le nang le tshepe le aba motlakase ka ho lekana ho pholletsa le dielectric.

Mokhoa oa ho iphekola o sebetsa nakong ea liketsahalo tsa overvoltage. Tšepe e potolohileng libaka tsa phoso e fetoha mouoane hang-hang. Sena se arola sebaka se senyehileng ha se ntse se boloka ts'ebetso ea capacitor. Sistimi ea hau e tsoela pele ho sebetsa ntle le tšitiso.

Bokhabane ba Tlhahiso

Setsi sa rona sa tlhahiso se latela maemo a tiileng a boleng. Capacitor e 'ngoe le e 'ngoe e feta litekong tse felletseng pele e romelloa. Re sebelisa lifilimi tsa polypropylene tsa boemo ba premium feela tse tsoang ho bafani ba nang le mangolo.

Taolo ea boleng e kenyelletsa liteko tsa motlakase o phahameng, potoloho ea mocheso, le netefatso ea nako ea bophelo. Sistimi ea rona ea taolo ea boleng ea ISO9001 e netefatsa ts'ebetso e tsitsitseng. Tsamaiso ea tikoloho ka setifikeiti sa ISO14001 e sireletsa polanete ea rona.

Sesebediswa se seng le se seng sa 10KV Film Capacitor se fihlela maemo a matjhaba ho kenyeletswa le IEC 60871 le IEC 61071. Ho latela melao ena ho netefatsa meedi ya polokeho kgahlanong le di-overvoltage tsa nakwana.

Lebaka Leo re Lokelang ho le Khetha

Boiphihlelo bo Pakiloeng

Xi'an Xikai o na le boiphihlelo ba mashome a lilemo ka lisebelisoa tsa motlakase o mahareng le o tlase. Lihlahisoa tsa rona li sebeletsa bareki ho pholletsa le tlhahiso ea motlakase, boiketsetso ba indasteri le merero ea meralo ea motheo.

Kakaretso ea Lihlahisoa tsa Lihlahisoa

Re fana ka ditharollo tse felletseng tsa kabo ya motlakase. Ho tloha ho switchgear ya motlakase o phahameng ho isa ho di-transformer, mokgwa wa rona o kopaneng o nolofatsa tshebetso ya hao ya ho reka.

Tšehetso ea tekheniki

Sehlopha sa rona sa boenjiniere se fana ka boeletsi ba litsebi nakong eohle ea bophelo ba projeke ea hau. Re thusa ho ntlafatsa khetho ea capacitor ho latela litlhoko tsa hau tse ikhethileng tsa ts'ebeliso.

Tšebelisano e Tšepahalang

Khetha moetsi ea ikemiselitseng likamano tsa nako e telele. Re fana ka tšehetso e tsoelang pele ea tekheniki le ho fumaneha ha likarolo tse ling lilemong tse tlang.

LBH

P: Ke eng e etsang hore li-capacitor tsa filimi li be betere ho feta mefuta ea ceramic bakeng sa lits'ebetso tsa 10kV?

K: Li-capacitor tsa filimi li felisa lerata la piezoelectric le mathata a ho petsoha a tloaelehileng mefuteng ea letsopa. Li boetse li fana ka bokhoni bo botle ba ho sebetsana le ho otla ha pelo le ho iphekola.

P: Hangata li-capacitor tsena li nka nako e kae?

A: Ka ho kenya le ho sebetsa hantle, li-capacitor tsa rona tsa lifilimi li fana ka bophelo bo tšepahalang ba tšebeletso ea lilemo tse fetang 20.

P: Na di-capacitor tsena di ka sebetsana le ho kenngwa ha kantle?

K: E, epoxy encapsulation e thibelang malakabe e sireletsa khahlanong le mongobo, maemo a feteletseng a mocheso le ho pepesehela mahlaseli a kotsi a UV lits'ebetsong tsa kantle.

P: Ke dikgetho dife tsa kganetso ya ho ntsha metsi tse fumanehang?

K: Re fana ka li-resistor tse kopantsoeng tsa ho ntša motlakase tse lekantsoeng bakeng sa phokotso e sireletsehileng ea motlakase nakong ea motsotso o le mong kamora ho khaoloa ha motlakase, tse fihlelang litekanyetso tsa polokeho.

P: Na le fana ka boleng ba capacitance bo ikgethileng?

K: Ehlile. Re etsa ditlhophiso tse ikgethileng ho fihlela ditlhoko tsa hao tse ikgethang tsa motlakase, bokgoni le ho kenya.

Ikopanye Rona - Factop

Na u se u loketse ho ntlafatsa ts'epo ea sistimi ea hau ea motlakase? Litsebi tsa rona tsa tekheniki li mona ho u thusa ho khetha tharollo e phethahetseng ea 10KV Film Capacitor bakeng sa ts'ebeliso ea hau.

Ikopanye le sehlopha sa rona kajeno bakeng sa litlhaloso tse qaqileng, litlhophiso tse ikhethileng, kapa lipuisano tsa tekheniki. Re ikemiselitse ho u fa likarolo tsa kabo ea matla tsa boleng bo holimo tse tšehetsoang ke tšehetso ea litsebi.

Imeile: serina@xaxd-electric.com

A re u thuseng ho fihlela ts'ebetso e phahameng ea sistimi ea matla ka theknoloji ea rona e tsoetseng pele ea capacitor ea filimi. Katleho ea hau ke ntho ea bohlokoa ho rona.

romela