ProductPic

Iphaneli yeMbuyekezo eSebenzayo ye-LV eZenzekelayo

1.i-voltage yenkqubo: Ngaphantsi kwe-AC450.
2.Imbuyekezo yamandla ezenzekelayo yokuphucula amandla.
3. Ukuphucula ukusebenza kakuhle kwezixhobo ngeendleko zotyalo-mali ezincitshisiweyo.
4. Ukunciphisa ilahleko zemigca yokusasazwa kunye nelahleko zetransformer.
5. Umgangatho we-voltage ophuculweyo kunye nokuthembeka kombane okuphuculweyo.
6. Ukuhambelana: Idibana neenkqubo zekhabhinethi zehlabathi (MNS/GCK/GGD).
  • Ukuhanjiswa ngokukhawuleza
  • quality Assurance
  • 24/7 INkonzo yabaThengi

Intshayelelo Product

Iphaneli yeMbuyekezo eSebenzayo ye-LV eZenzekelayo - Isisombululo soLungiso lweZinto zoBugcisa

Intshayelelo Product

Ngaba ujonge ukuphucula ukusebenza kakuhle kwenkqubo yakho yombane kunye nokunciphisa iindleko zamandla? Iphaneli yethu ye-LV Automatic Reactive Compensation inika ulungiso olukrelekrele lwezinto zamandla kwiimveliso zanamhlanje kunye nezorhwebo. Le nkqubo yolungiso lwezinto zamandla ephucukileyo ijonga ngokuzenzekelayo umthwalo wakho wombane kwaye ilungisa ngokuguquguqukayo imbuyekezo yamandla esabelayo ukugcina amanqanaba afanelekileyo ezinto zamandla.

Iphaneli isebenza kwii-voltage zenkqubo ezingaphantsi kwe-AC 450V, inika imbuyekezo yamandla aphendulayo ngokuzenzekelayo engenamthungo ephucula kakhulu amandla esixhobo sakho. Uya kufumana ukusebenza kakuhle kwezixhobo ngokunciphisa iindleko zotyalo-mali, ukunciphisa ilahleko zemigca yokusasazwa, kunye nomgangatho we-voltage ophuculiweyo ophucula ukuthembeka kokunikezelwa kombane ngokubanzi. Iiphaneli zethu zembuyekezo zidibana ngokugqibeleleyo neenkqubo zekhabhinethi zehlabathi kubandakanya i-MNS, i-GCK, kunye noqwalaselo lwe-GGD.

Ezi paneli zakhiwe yiXi'an Xidian Medium and Low Voltage Electric Co., Ltd., zimele amashumi eminyaka olwazi kwimveliso yezixhobo zokusasaza umbane. Uluhlu lwethu olupheleleyo lweemveliso lugubungela ii-voltage ezilinganisiweyo ukusuka kwi-0.4kV ukuya kwi-40.5kV kunye nemisinga elinganisiweyo eqala kwi-630A ukuya kwi-4000A, zonke zihlangabezana nemigangatho yesizwe neyehlabathi.

Izikhankanyi Technical

ye parameter Inkcazo
Voltage ikaliwe 380V, 400V, 415V, ukuya kuthi ga kwi-690V
Ubuninzi 50 / 60Hz
Inkqubo yeVoltage Ngaphantsi kwe-AC 450V
Ukutshintsha iTekhnoloji IiContactor Duty / Iimodyuli zeThyristor
Ixesha lokuphendula <20ms (iThyristor) / 2-5s (iContactor)
Uhlobo lweCapacitor I-Polypropylene enesinyithi (MPP) ene-Self-healing
Isalathisi seNgcaciso IP42 / IP54
ngamaqondo yokusebenza -25 ° C ukuya kwi-55 ° C
I-algorithm yokulawula Step-based (1:1:1, 1:2:2, 1:2:4)
Amandla Factor Range 0.8 ukuya kwi-0.99 (ehamba phambili/ehamba emva kwexesha)
Ukhuseleko lweHarmonic IiReactor eziDibeneyo (iinketho ze-7% / 14%)

Iimpawu eziphambili kunye nezinto eziluncedo

Ulawulo lweMicroprocessor ekrelekrele

Iiphaneli zethu zineenkqubo zolawulo ezisekwe kwi-microprocessor eziphambili ezihlala zijonga amandla kwaye zitshintsha ngokuzenzekelayo iibhanki ze-capacitor. Olu lawulo lukrelekrele luphelisa ukungenelela ngesandla ngelixa luqinisekisa imbuyekezo efanelekileyo.

Itekhnoloji yokunciphisa iHarmonic

Ii-reactors ezidityanisiweyo ezithintelweyo zithintela iimeko eziyingozi zokurhawuzelelwa kwiinethiwekhi ezinemithwalo ephezulu engeyiyo emgceni. Oku kukhusela ii-capacitors zakho ekusileleni kwangethuba ngelixa kunciphisa ukuphambuka kwe-harmonic iyonke.

Iinketho ezininzi zokutshintsha

Khetha phakathi kweenkqubo ezitshintshiweyo zecontactor zemithwalo ezinzileyo okanye iinkqubo ezitshintshiweyo zethyristor ukuze ufumane utshintsho olukhawulezileyo lomthwalo. Zombini ezi ndlela zibonelela ngokusebenza okuthembekileyo nokuhlala ixesha elide okulungiselelwe iimfuno zakho zesicelo.

Ukhuseleko lweNkqubo eyomeleziweyo

Iimpawu zokhuseleko ezakhelwe ngaphakathi ziquka ukhuseleko olugqithisileyo kwi-voltage, ukujonga ubushushu, kunye nokujonga ulandelelwano lwesigaba. Ezi nkqubo zokhuseleko zikhusela zombini iphaneli kunye nezixhobo zakho eziqhagamshelweyo.

Izicelo eziSebenzayo

Imveliso yoShishino

Imizi-mveliso emikhulu kuquka iifektri zentsimbi, iifektri zesamente, kunye neendawo zokucubungula iikhemikhali ziyazuza kwiiphaneli zethu zokuhlawula ezisabelayo. Ezi ndawo zineemoto ezinkulu kunye nemithwalo yokungenisa umoya zibona uphuculo olukhawulezileyo ekusebenzeni kakuhle kwamandla.

Izakhiwo zorhwebo

Iinqaba zeeofisi, iindawo zokuthenga, kunye nezibhedlele zixhomekeke kwiiphaneli zethu ukuze ziphucule iinkqubo ze-HVAC kunye nokusasazwa kwezibane. Ukuphuculwa kwamandla okuqhubekayo kunciphisa iindleko zamandla ngelixa kuqinisekiswa ukusebenza okuthembekileyo.

IiProjekthi zeziseko zophuhliso

Izityalo zokunyanga amanzi, izitishi zokumpompa, kunye nezakhiwo zikamasipala zisebenzisa iiphaneli zethu zokuhlawula ukunciphisa imfuno ebonakalayo yamandla kwiitransformer kunye neejenereyitha zokuxhasa.

Amaziko eDatha

Izakhiwo ezibalulekileyo ezifuna ixesha lokusebenza eliyi-99.999% zithembe iinkqubo zethu ze- LV Automatic Reactive Compensation Panel ezisekelwe kwi-thyristor zokutshintsha okungenazithintelo ezithintela ii-voltage transients.

Ingaba isebenza kanjani

Iphaneli yokuhlawula isoloko ijonga ubudlelwane besigaba phakathi kombane kunye nombane kwinkqubo yakho yombane. Xa imithwalo ye-inductive idala amandla angaphantsi, umlawuli we-microprocessor utshintsha ngokuzenzekelayo iibhanki ze-capacitor kwi-intanethi ukuze unikeze amandla asebenzayo akhokelayo.

Le nkqubo isebenzisa ii-algorithms ezintsonkothileyo ukumisela inani elifanelekileyo lamanyathelo e-capacitor afunekayo. Ii-resistor zangaphambi kokufakwa zinciphisa umbane wokungena ngexesha lokutshintsha, ngelixa ii-reactors ezivaliweyo zikhusela kwi-harmonic resonance. Ukubeka iliso kubushushu kuqinisekisa ukuba ii-capacitor banks zisebenza ngaphakathi kwemida ekhuselekileyo yobushushu.

Kwimithwalo enamandla, ukutshintsha i-thyristor kunika impendulo ekhawulezileyo ngaphandle kokuguguleka koomatshini. Isilawuli sigcina amandla ngaphakathi koluhlu olufunayo ngelixa sikhusela izixhobo kwimbuyekezo engaphezulu.

UkuGqwesa kwemveliso

I-Xi'an Xidian Medium and Low Voltage Electric Co., Ltd. izise amava angamashumi eminyaka ekwenzeni izixhobo zokusasaza umbane. Izakhiwo zethu zigcina ulawulo lomgangatho we-ISO9001, ulawulo lokusingqongileyo lwe-ISO14001, kunye neziqinisekiso ze-OHSAS18001 zempilo nokhuseleko emsebenzini.

Sisebenzisa iinkqubo zokuvelisa eziphambili kunye nolawulo oluqinileyo lomgangatho kuzo zonke izigaba zemveliso. Ukususela ekukhethweni kwezixhobo ukuya kuvavanyo lokugqibela, iphaneli nganye ye-LV Automatic Reactive Compensation ihlolwa ngokupheleleyo ukuqinisekisa ukusebenza okuthembekileyo.

Iqela lethu lobunjineli lihlala liphuhlisa izisombululo ezintsha lisebenzisa ubuchwepheshe kunye nezixhobo zamva nje. Oku kuzibophelela ekuphuculeni izinto kugcina iimveliso zethu ziphambili kwimigangatho yoshishino.

Kutheni Sikhetha

Uluhlu lweeMveliso eziBanzi

Ikhathalogu yethu ebanzi igubungela iindidi ezisithoba ezinezixhobo ezingama-34 kunye neentlobo ezingaphezu kwe-100 zezixhobo zokusasaza umbane. Olu bubanzi luqinisekisa ukuba sinokubonelela ngezisombululo zenkqubo ezipheleleyo ezilungiselelwe iimfuno zakho.

Ukuthembeka

Iimveliso ezilinganiswe ukuba zisebenze ukuya kuthi ga kwi-4000m ngaphezu komphakamo wolwandle zibonisa ukuzinikela kwethu kuyilo oluqinileyo. Izalathisi zobugcisa zidlula imigangatho yesizwe neyeshishini rhoqo.

Inkxaso yeNgcali

Iqela lethu lobuchwephesha libonelela ngoncedo loyilo lwenkqubo, isikhokelo sokufakelwa, kunye nenkxaso eqhubekayo kulo lonke ixesha lobomi bezixhobo zakho. Singamaqabane empumelelweni yakho.

quality Assurance

Zonke iimveliso zivavanywa ngokungqongqo kwaye ziqinisekiswa umgangatho. Udumo lwethu lokuthembeka luye lwafumana ukuqatshelwa njengemveliso yophawu oludumileyo eTshayina.

FAQ

Q: Iphaneli kufuneka igcinwe kangaphi?

A: Kucetyiswa ukugcinwa okupheleleyo rhoqo ngonyaka. Oku kuquka ukujonga uqhagamshelo lombane, ukucoca izihluzi zomoya, kunye nokuqinisekisa ukusebenza kwe-capacitor.

Q: Ngaba iphaneli inganciphisa iindleko zombane?

A: Ewe, ngokuphelisa izohlwayo zezixhobo zamandla ombane kunye nokunciphisa iindleko zemfuno ye-kVA. Uza kubona nokuncipha kwelahleko zangaphakathi kwinkqubo.

Q: Yintoni umahluko phakathi kokutshintsha kwe-contactor kunye ne-thyristor?

A: Ukutshintsha i-contactor kulungele imithwalo ezinzileyo enexesha lokuphendula elicothayo. Ukutshintsha i-Thyristor kunika impendulo ekhawulezileyo kwimithwalo etshintsha ngokukhawuleza ngaphandle kokuwohloka koomatshini.

Q: Ndingakuthintela njani ukungaphumeleli kwe-capacitor?

A: Umoya ofanelekileyo, ulawulo lwe-voltage, kunye nokunciphisa i-harmonic ngokusebenzisa ii-reactors ezivaliweyo kwandisa ubomi be-capacitor.

Q: Ingaba iphaneli ifanelekile kwiindawo ezinobutyebi be-harmonic?

A: Ewe, ukhetho lwethu lwe-reactor oludibeneyo lujongana ngqo nokunciphisa i-harmonic, okwenza iiphaneli zilungele izibonelelo ezinee-variable frequency drives kunye neminye imithwalo engekho yomgca.

Qhagamshelana nathi

Ngaba ukulungele ukuphucula ukusebenza kakuhle kombane kwiziko lakho? Iingcali zethu zobugcisa zimi ecaleni ukuze zixoxe ngeemfuno zakho ezithile kwaye zinikeze izisombululo ezenzelwe wena.

Nxibelelana nathi namhlanje ku-serina@xaxd-electric.com ukuze ufunde okungakumbi malunga neendlela zethu ze-LV Automatic Reactive Compensation Panel kunye nendlela esinokuyenza ngcono ngayo indlela esebenza ngayo inkqubo yakho yombane.

thumela