Xa ukhetha ii-SF6 circuit breakers ezine-voltage ephezulu kwizicelo zegridi, ukuqonda iingenelo ezikhethekileyo zee- SF6 circuit breakers zangaphandle kuba yinto ebalulekileyo. Ezi zixhobo zisebenzisa igesi ye-sulfur hexafluoride ukubonelela ngokuphazamiseka okugqwesileyo kwe-arc kunye nokukwazi ukufihla kwiinethiwekhi zothumelo kunye nokusasazwa. Esi sikhokelo sibanzi sinceda abaphathi bokuthenga, abaqhubi bezakhiwo, iinjineli zeenkonzo, kunye neengcali ze-EPC ukuba zilandele imigaqo yokukhetha ebalulekileyo—ukusuka kwiinkcukacha zobugcisa kunye nokuqina kokusingqongileyo ukuya kwiindleko zomjikelo wobomi kunye nokuthotyelwa kwemithetho—ukuqinisekisa ukuba utyalo-mali lwakho lubonelela ngexesha eliphezulu lokusebenza, uzinzo lwegridi, kunye nokusebenza kakuhle.

                            ibhlog-1-1ibhlog-1-1​​​​​​​

intshayelelo

Ukuze iintambo zombane zanamhlanje zisebenze, izixhobo zokutshintsha kufuneka zithembeke, zikhuseleke, kwaye zifikeleleke ngexabiso eliphantsi. Ii-SF6 circuit breakers ezine-voltage ephezulu zifanelekile kwiinethiwekhi zothumelo kunye nezikhululo ezingaphantsi ezine-voltages ezingama-72.5kV ukuya kuma-800kV. I-SF6 circuit breaker engaphandle eqinileyo iphawuleka ngokuthembeka kwayo okuqhubeke iminyaka emininzi.

Ii-SF6 gas circuit breakers zincinci, azidingi kugcinwa kakhulu, kwaye zingcono ekumiseni ii-arcs kuneteknoloji egcwele ioyile okanye yokuqhuma komoya. Abasebenzi begridi bajongene noxinzelelo olukhulayo lokunciphisa ixesha lokungasebenzi kunye nokongeza amandla ahlaziyekayo. Ukukhetha i-circuit breaker efanelekileyo kuyingcinga. Le ncwadi igubungela imiba ebalulekileyo abaphathi bezakhiwo, iinkampani zeenkonzo, kunye namashishini e-EPC abajongene nayo ngelixa befumana iindawo ezidumileyo zeeprojekthi ezinzima.

Siza kuhlola iziseko zezi zixhobo, sizithelekise nezinye iitekhnoloji, sixoxe ngezinto ekufuneka siziqwalasele xa sizithenga, size sixoxe ngendlela yokuzigcina zisemgangathweni. Siza kusebenzisa iXi'an Xikai's LW25 Outdoor Porcelain Type SF6 Circuit Breaker ukubonisa indlela iinkcukacha ezichaphazela ngayo ukusebenza kwehlabathi lokwenyani.

Ukuqonda ii-Outdoor SF6 Circuit Breakers: Ukusebenza kunye neenzuzo

Indlela i-SF6 Gas Cima ngayo ii-Electric Arcs

Amandla e-dielectric egesi ye-SF6 aphezulu ngokuphindwe kathathu kunalawo omoya ophantsi koxinzelelo oluqhelekileyo. Uqhagamshelwano lwe-breaker luyahlukana ngexesha lokuphazamiseka kwempazamo, okwenza i-arc yombane. Nokuba zizixhobo ze-puffer okanye eziziqhumisayo kwi-SF6 circuit breaker zihambisa igesi ye-SF6 ehamba ngokukhawuleza kwindlela ye-arc. Ngenxa yokuba iimolekyuli ze-SF6 zitshajwa kakubi, zikhawuleza zibambe ii-electron ezikhululekileyo. Oku kukhokelela ekuhlanganisweni kwakhona kwee-ions kunye nokuphela kwe-arc ngaphakathi kwee-milliseconds. Le ndlela yokwandisa ubushushu, enokubonwa kwimodeli ye-LW25 kaXi'an Xikai, iyamisa ukuhamba ngesenzo esidibeneyo phakathi koqhagamshelwano lwe-arc oluzinzileyo, ii-nozzles, kunye nee-puffer cylinders. Oku kugcina uxinzelelo olufanelekileyo lwe-blast ngaphandle kokubeka uxinzelelo olukhulu kakhulu kwinkqubo.

Uvavanyo oluqhelekileyo lwezicelo zeGrid

Ii-circuit breakers ze-SF6 zangaphandle ezisetyenziselwa ukudlulisa zihlala zisingatha ii-voltages eziphakathi kwe-126kV kunye ne-252kV kunye nee-currents eziphakathi kwe-2000A kunye ne-4000A kwi-50Hz. I-LW25 Outdoor Porcelain Type SF6 Circuit Breaker yenzelwe iinkqubo ze-126kV/145kV kwaye inokusingatha ii-currents ezifikelela kwi-4000A. Ngumzekelo wezixhobo ezinokusetyenziswa kwizikhululo zombane, kwii-complexes zoshishino, nakwii-connections zemithombo yamandla ahlaziyekayo. La maxabiso avumela ii-fault currents ezifikelela kwi-50kA, oko kuthetha ukuba i-breaker inokukhusela ii-transformers, ii-busbars, kunye neentambo zamandla ngexesha le-short-circuits ngaphandle kokonakalisa i-insulation.

Uyilo oluQhelekileyo kunye namandla aphezulu e-dielectric

Xa kuthelekiswa neswitchgear efakwe umoya, iimpawu zokugquma ezingcono ze-SF6 zivumela abavelisi ukuba banciphise kakhulu umgama phakathi kweepali kunye nobukhulu bee-interruptors. Ii-porcelain housing ezinokumelana notshintsho lobushushu phakathi kwe--30°C kunye ne-50°C, umonakalo we-UV, kunye nokwanda kongcoliseko zilungile ekufakweni kwe -SF6 circuit breaker yangaphandle . Olu yilo luncinci lunciphisa iindleko zokufakela kunye nobungakanani bomhlaba ofunekayo, nto leyo ebaluleke kakhulu kwizikhululo zedolophu nakwiifama zomoya ezikude apho indawo encinci yenza ukuba iprojekthi ingasebenzi.

IiMfuno eziNcitshisiweyo zoLondolozo

Ii-circuit breakers zanamhlanje ze-SF6 zangaphandle zinee-interrupter cells ezivalwe ubomi bonke kwaye zinamazinga okuvuza minyaka le angaphantsi kwe-0.5%. Akukho mfuneko yee-nitrogen cylinders okanye ii-hydraulic reservoirs ezintsonkothileyo xa kukho iindlela ze-spring ezizitshajayo ezifana nezo zikwinkqubo ye-LW25's electric motor-charged closing spring. Ukuhlolwa kwenzeka rhoqo emva kweminyaka engama-25 ukuze kuhlolwe rhoqo kunye nokusebenza koomatshini ukuya kuthi ga kwi-10,000 ngaphambi kokulungiswa okukhulu. Oku kunciphisa kakhulu iindleko zokusebenza kunye nexesha lokungasebenzi elicwangcisiweyo xa kuthelekiswa nee-oil circuit breakers ezifuna ukuhluzwa kwaye zivavanyelwe i-dielectric rhoqo.

Ukuthelekisa ii-Outdoor SF6 Circuit Breakers kunye neeTekhnoloji ezizezinye

Iiparamitha zoMsebenzi: Ukuphathwa kweVoltha kunye nokuTshintsha amandla

Ii-vacuum circuit breakers zisebenza kakuhle kwiimeko ze-medium voltage (ukuya kuthi ga kwi-40.5kV), kodwa azisebenzi kakuhle kwiinethiwekhi zenqanaba lokudlulisela, apho kufuneka ziphazamise uqhagamshelo kwaye zijongane nee-voltage eziphezulu. Nangona ii-air-blast breakers zisebenza kakuhle kwii-voltage eziphezulu, zifuna ukufakelwa kwe-compressor enkulu kwaye zenze ingxolo eninzi. Ii-oil circuit breakers zinokubangela imililo kwaye zingcolise okusingqongileyo kuba i-shielding oil iyaphuka. Ii-outdoor SF6 circuit breakers, kwelinye icala, zinokubuyiswa kwe-dielectric ngokukhawuleza (ngesiqhelo ngaphakathi kwemijikelo emibini), zinokusingatha zombini i-capacitive kunye ne-inductive switching nge-overvoltages encinci, kwaye zinokugcina ukusebenza kwazo kuzinzile kuluhlu olubanzi lwamaqondo obushushu angqongileyo. Ezi zibonelelo zikhokelela ngokuthe ngqo ekuthembekeni okuphezulu kwegridi kubaqhubi beenkonzo.

Iimfuno zoLondolozo kunye neendleko zoBomi

Ixabiso lilonke lohlalutyo lobunini lubonisa ukuba kutheni ii-breakers ezifakwe igesi zixhaphake kakhulu ekusetyenzisweni kweebhokisi zeegiya. Ngokwemithetho malunga nenkunkuma enobuthi, ii-oyile breakers kufuneka zivavanye ioyile yazo, zihluzwe, kwaye ekugqibeleni zilahlwe. Iinkqubo zokuqhuma komoya zifuna ukugcinwa rhoqo kwimpompo kunye nokutshintshwa kweendawo ezinomoya. Ii-vacuum breakers kulula ukuzigcina, kodwa azinakusetyenziswa ukonyusa okanye ukunciphisa i-voltage. Ii-outdoor SF6 circuit breakers zinezona mfuno ziphantsi zokugcinwa rhoqo—ukuhlolwa okubonakalayo kuphela, ukulandelwa koxinzelelo lwe-SF6, kunye novavanyo lweempawu zoomatshini—kunye nenani eliphantsi lokutshintshwa okunokusetyenziswa. Oku kuthetha ukuba kwiminyaka engama-30 yokusebenza, zibiza ngaphantsi ngama-30-40% kune-oyile okanye iteknoloji yomoya.

Iingqwalasela zokusiNgqongileyo noKhuseleko

Ngexesha lokusebenza okuqhelekileyo, igesi ye-SF6 ayithathi cala kwiikhemikhali, ayitshi, kwaye ayiyongozi. Oku kuthetha ukuba akukho mingcipheko yokuqhuma enxulumene nokufuma okanye ukutsha kweoyile. Nangona kunjalo, i-SF6 yigesi enamandla yokutshisa izityalo ejongwa ngokusondeleyo ngabalawuli ngeenkqubo ezifana ne-EU F-Gas Regulation kunye nenkqubo ye-EPA SNAP. Abavelisi abanoxanduva basebenzisa uyilo olutywiniweyo oluneenkqubo zokufumanisa ukubuya kwegesi kunye nokuvuza ezakhelwe ngaphakathi. Amanyathelo okulawula umgangatho eXi'an Xikai aqinisekisa ukuba izinga lokulahleka konyaka lihlala lingaphantsi kwe-0.1%. Oku kuhlangabezana neenjongo zozinzo lwenkampani kwaye kugcina imisebenzi ikhuselekile. Xa ilawulwa ngokuchanekileyo, ii-SF6 circuit breakers zangaphandle zikhetho ezinobuhlobo nokusingqongileyo kuba ziphathwa ngokufanelekileyo kwaye igesi iphinda isetyenziswe ekupheleni kobomi bayo obuluncedo.

Uthelekiso lweBrand: Iinkcukacha kunye neNkxaso

Abavelisi abaphambili bazibeka bodwa ngokulinganisa ukunyamezela koomatshini, uyilo lwe-interrupter, kunye nokuxhasa iziseko emva kokuthengiswa. Iimpawu zaseNtshona Yurophu zigxila kuyilo lweemodyuli ezivumela ukugcinwa okwahlulwe ngokwezigaba. Iimpawu zaseAsia, kwelinye icala, zifumana umxube phakathi kwexabiso eliphantsi kunye nokuthembeka okuqinisekisiweyo. Xa kuthengwa kubathengisi abathengisa ngobuninzi, amaqela kufuneka ajonge ukuba aqinisekisiwe na yi-ISO 9001, ajonge imiqathango yesiqinisekiso (edla ngokuba ziinyanga ezili-18 ukuya kwezingama-24), kwaye aqinisekise ukuba iindawo ezingasetyenziswayo ziyafumaneka kwiindawo apho zikhonza khona. Umsebenzi owenziwe yiXi'an Xikai kumazwe angaphezu kwama-30 ubonisa ukuba uthotho lwayo lokubonelela luqinile kwaye inkxaso yayo yobuchwephesha iyakhawuleza ukuphendula. Ezi zizinto ezigcina ukulibaziseka kweprojekthi kunye nemingcipheko yokusebenza kwexesha elide incinci.

Izinto ekufuneka ziqwalaselwe xa kuthengwa izixhobo zombane zangaphandle ze-SF6 Circuit Breakers

Ukuchaza iiMfuno zobuGcisa

Ukuze uthenge kakuhle, kufuneka ucacelwe zizinto zombane, ezifana ne-voltage elinganisiweyo, i-current elinganisiweyo, i-current short-circuit breaking current, i-rated working sequence (O-0.3s-CO-3min-CO), kunye neklasi yokunyamezela koomatshini/umbane. Izinto zokusingqongileyo ezifana nokuphakama, ubushushu, ukuhlelwa kwendawo ye-seismic, kunye nenqanaba longcoliseko (IEC 60815) zinefuthe ngqo ekukhetheni i-insulator kunye nezinto zokuhlala. Indlu ye-porcelain ye-LW25 kunye noyilo oluhambelana ne-IEC kuyenza ifaneleke kwiindawo ezinenkungu yetyuwa, ungcoliseko lwemizi-mveliso, kunye nothuli lwasentlango. Nangona kunjalo, abathengi kufuneka baqinisekise ukuba iinkcukacha ze-SF6 circuit breaker zangaphandle zilungile kwindawo yabo ukuze baphephe ukungaphumeleli kwe-insulation okanye iingxaki zoomatshini.

Ukuthotyelwa kweMigangatho yeHlabathi

Zonke ii-circuit breakers ze-voltage ephezulu eziza kuthengiswa e-US kufuneka zibonise ukuba ziyahlangabezana ne-IEEE C37.04 (uvavanyo), i-IEEE C37.06 (uvavanyo olukhethwayo), kunye ne-IEEE C37.09 (iinkqubo zovavanyo). I-IEC 62271-100 ibeka imithetho yovavanyo lohlobo kunye nokuqinisekiswa koyilo kwihlabathi liphela. Abathengi kufuneka bacele iziphumo zovavanyo lohlobo ezigubungela ukusebenza kwiindawo ze-dielectric, mechanical, thermal, kunye ne-short-circuit. Izatifikethi ezingaphezulu, ezifana ne-ATEX kwiindawo eziqhumayo, i-IECEx kwiindawo eziyingozi, kunye nothotho lwe-ANSI C37 kwiindawo zase-US, zenza kube nokwenzeka ukusetyenziswa okungakumbi, kodwa kufuneka zichazwe ngokucacileyo ngexesha lenkqubo yokubhida. Ukuqinisekisa ezi ziqinisekiso kuyayekisa utshintsho olubizayo kwiprojekthi kunye neentlawulo zokungalandeli imithetho.

Iimpawu zokulinganisa amaxabiso kunye namaxesha okukhokela

Xa ucwangcisa uhlahlo lwabiwo-mali lwakho, kufuneka uqwalasele umahluko weklasi ye-voltage. Umzekelo, ii-126kV zangaphandle ze-SF6 circuit breakers zinokubiza imali encinci ukuya kwenkulu, ngokusekelwe kumaxabiso azo angoku kunye nokuba indlela ezisebenza ngayo inzima kangakanani. Ngenxa yokuba azidingi zixhobo zininzi ezongezelelweyo, iindlela ze-hydraulic spring mechanisms zibiza kakhulu kuneenkqubo ze-pneumatic. Amaxesha aqhelekileyo okukhokela ziiveki ezili-12 ukuya kwezili-16 kwiinkcukacha eziqhelekileyo. Zingafikelela kwiiveki ezingama-20 ukuya kwezingama-24 kwiindlela ezenziwe ngokwezifiso ezifuna ii-coating ezikhethekileyo, iiwaranti ezinde, okanye uvavanyo lokwamkelwa kwifektri. Ukuseta izivumelwano zesakhelo nababoneleli abaqinisekisiweyo abanjengoXi'an Xikai kwenza kube lula ukuthenga kubo kwakhona, kugcina amaxabiso ezinzile, kwaye kuqinisekisa ukuba imveliso isebenza kakuhle ngamaxesha emfuno ephezulu.

Ukukhetha ababoneleli abahloniphekileyo

Xa uvavanya umthengisi, kufuneka ujonge okungaphezulu nje kwexabiso. Kwakhona kufuneka ujonge izakhono zabo zokwenza, iinkqubo zokulawula umgangatho, kunye nenkonzo yabathengi emva kokuthengisa. Uhlolo lwesiza lujonga ukuba ingakanani into enokwenziwa kunye nokuba ulawulo lomgangatho lwenziwa kakuhle kangakanani. Iifektri eziqinisekisiweyo ze-ISO 9001 zeXi'an Xikai zisebenzisa i-robotic assembly kwaye zinokulandela yonke inxalenye. Iingxelo ezivela kwiiprojekthi ezifanayo zixhasa amabango okuthembeka kunye nezakhono zoncedo lokufakela. Iziphene zokwenza, amazinga okuvuza kwe-SF6, kunye namanani omsebenzi woomatshini kufuneka zonke zigutyungelwe yiwaranti. Ukufumaneka kwenkxaso yobugcisa, njengeefowuni ezishushu ezivuliwe iiyure ezingama-24 ngosuku, iintsuku ezisixhenxe ngeveki, kunye nokuhanjiswa kwezixhobo ezingasetyenziswanga, kunefuthe ngqo kwimilinganiselo yexesha eliphakathi lokulungisa (MTTR) kunye nokusebenza kwezixhobo ngokubanzi (OEE) ezibalulekileyo kwiinkampani zeenkonzo kunye nabaqhubi bezibonelelo.

Ukugcinwa, Ukusombulula iingxaki, kunye noKhuseleko Iindlela ezilungileyo

IiProtokholi zokuHlola rhoqo

Ukuze izinto ziqhubeke zisebenza kakuhle, ii-insulators ze-porcelain kufuneka zihlolwe ukuba azinazo na iintanda okanye ungcoliseko rhoqo emva kweenyanga ezintathu, i-SF6 pressure gauge kufuneka ihlolwe rhoqo emva kweenyanga ezintandathu, kwaye rhoqo ngonyaka, iimpawu zoomatshini kufuneka zivavanywe kusetyenziswa izixhobo zokurekhoda ezikhawulezayo. I-SF6 circuit breaker yangaphandle inoyilo lwe-sealed interrupter oluyenza ukuba ukugcinwa kungangeni kakhulu. Nangona kunjalo, ii-ultrasound okanye ii-infrared sensors kufuneka zisetyenziswe ukujonga ukuvuza rhoqo ukuze kumiswe ukulahleka koxinzelelo okunciphisa amandla okuphazamisa. Abavelisi abanjengoXi'an Xikai banikezela ngezicwangciso zokulungisa ezipheleleyo ezihambelana nezikhokelo ze-IEC 62271-1. Ezi shedyuli zichaza amaxesha okuhlola ngokusekelwe kwinani lemisebenzi endaweni yexesha elingacwangciswanga.

Ukubeka iliso kwiGesi ye-SF6 kunye nokuFumanisa ukuvuza

Ii-SF6 circuit breakers zanamhlanje zangaphandle zineenkqubo zokujonga uxinzelelo ezikhala i-alamu xa uxinano luhla ngaphantsi kwamanqanaba okusebenza aphantsi, adla ngokuba yi-0.5 MPa kwi-20°C. Minyaka le, iimonitha ze-SF6 eziphathwayo ezinobuthathaka obungaphantsi kwe-1 ppm zisetyenziselwa uvavanyo lokuvuza okunomlinganiselo, olufumana ukonakala kwetywina ngaphambi kokuba kukhokelele ekusileleni kokusebenza. Ngenxa yokuba iimveliso ze-SF6 zitsala amanzi, uphando lomxholo womswakama luyimfuneko ukugcina ubungakanani bungaphantsi kwe-150 ppm ukuze i-hydrofluoric acid ingenzeki. Ukuze kuphathwe ngokukhuselekileyo iigesi, kufuneka izixhobo zokubuyisela ezivunyiweyo kwi-IEEE C37.122.3. Oku kuqinisekisa ukuba abasebenzi bakhuselekile kwaye imigaqo iyalandelwa ngexesha lokulungiswa okanye xa izixhobo zicinyiwe.

Ukuxilongwa Kweziphene Eziqhelekileyo kunye Nezenzo Zokulungisa

Amaxesha amade phakathi kokuvula nokuvala, i-asynchrony yamanqanaba amathathu engaphezulu kwe-2ms, okanye ukumelana okuphezulu koqhagamshelwano okungaphezulu kwe-50μΩ zonke ziimpawu zokungaqheleki kokusebenza. Ezi mpawu zibonisa amakhonkco oomatshini agugileyo, izipringi ezigugileyo, okanye iindawo zoqhagamshelwano ezigugileyo. Uhlalutyo lwe-micro-motion lokuhamba koqhagamshelwano, uvavanyo lwe-voltage olumelana ne-frequency yamandla, kunye nokulinganisa ukukhutshwa okuncinci ukuze kufunyanwe ukubola kwe-insulation zezinye zeenkqubo zokuxilonga ezisetyenziswayo. Izifundo zetyala ezivela kwiindawo zoshishino zibonisa indlela ukusebenzisa ezi zixhobo zokuxilonga ukugcinwa kwangaphambili okunokwandisa ubomi benkonzo yee- outdoor SF6 circuit breakers ngaphaya kweminyaka engama-30 kwaye kuzigcine zingaphuki ngexesha leemeko zomthwalo ophezulu. Ngokulandela imiyalelo yomenzi, abasebenzi abafanelekileyo banokuphepha ukwenza uxilongo olungalunganga kwaye baqinisekise ukuba kuthathwa amanyathelo afanelekileyo ukubuyisela iinkcukacha zokusebenza koyilo.

Imilinganiselo yoKhuseleko kunye nokuThotyelwa kweMimiselo

Xa usebenza ne-SF6, kufuneka uqaphele iingozi zokufunxa umoya kwiindawo ezincinci kunye nobuthi beemveliso ze-arc byproducts. Kumagumbi okutshintsha i-switchgear avaliweyo, abasebenzi bokulungisa kufuneka banxibe izixhobo zokuphefumla ezizimeleyo (SCBA), izixhobo zokhuseleko ezilinganiswe yi-arc, kwaye balandele amanyathelo okutshixa/ukuthena ukuze umbane ungavulwa ngengozi. Imithetho ye-EPA ifuna ukuba iibhanki zezixhobo eziphethe ngaphezulu kweepawundi ezili-17.5 zegesi ye-SF6 zibike amazinga azo okuvuza. Oku kukhokelele ekusetyenzisweni ngokubanzi kweenkqubo ezivaliweyo kunye nokwakhiwa kweziseko zokuvuselela igesi. Njengendlela yokukhusela okusingqongileyo, i-Xi'an Xikai isebenzisa iinqanawa zokubuyisela ezikhethiweyo, iinkampani ezivunyiweyo ukulahla igesi emdaka, kunye nobudlelwane bokuzithandela bokunciphisa ungcoliseko lwe-SF6. Zonke ezi zinto i-Xi'an Xikai ezakha kwiinkqubo zayo zokuxhasa umjikelo wobomi bemveliso.

Iindlela Zekamva kunye Nobuchule Bobuchwepheshe Kwiziqhekezo Zesekethe Zangaphandle ze-SF6

Uphuhliso lweendlela ezizezinye zegesi ze-SF6

Imithetho ejolise ekunciphiseni amandla okufudumala kwehlabathi e-SF6 (i-GWP 23,500 kwiminyaka eli-100) ikhawulezisa ukukhangela ezinye iigesi zokukhusela. Imixube ye-Fluoronitrile (i-C4F7N/CO2 blends) yehlisa i-GWP ngama-99% ngelixa isenamandla okuphazamisa afanayo ne-SF6 ecocekileyo. Itekhnoloji yokuphazamisa i-vacuum iyaqhubeka nokuqhubela phambili ukuya kumanqanaba aphezulu ombane, okunokuthi kususe uyilo lwe-SF6 circuit breakers zangaphandle kuluhlu lwe-145-245kV kwiminyaka elishumi ezayo. Abathengi abaceba ukubekwa emgangathweni kweenqwelo-moya ixesha elide kufuneka bajonge olu phuhliso, belinganisa iimfuno zokusebenza zangoku ngokuchasene nezicwangciso zemithetho yexesha elizayo kunye neendleko zokulungisa izinto.

Uphuhliso kwiindlela zokuRisayikilisha iGesi

Iinkqubo zokucoca ze-SF6 kwindawo ngoku zenza kube nokwenzeka ukuhlaziya igesi engcolisiweyo ngexesha lokulungiswa okukhulu. Oku kunciphisa imfuneko yegesi entsha ngama-80% kwaye kunciphisa umngcipheko wekhabhoni osebenzayo. Xa abasebenzi basentsimini betshintsha ii-SF6 circuit breakers zangaphandle okanye bevala iinkqubo, banokuyifumana igesi kwakhona besebenzisa ii-recovery carts eziphathekayo ezinee-vacuum pumps, ii-moisture traps, kunye nee-filtering modules. Ngakumbi nangakumbi, abenzi bezixhobo banikezela ngeenkqubo zokubuyisela umva eziqokelela ii-breakers ezindala zokukhupha igesi kunye nokurisayikilisha iindawo. Le yimizekelo yeeprojekthi zoqoqosho olujikelezayo ezinokuthi iinkonzo ezifuna ukuhlangabezana nezithembiso ze-net-zero kunye neenkampani ezineenjongo eziluhlaza zixhase.

Ulondolozo Lokuqikelela Oluvulwe Yi-IoT

Izinzwa ezifakiweyo ezilandelela uxinano lwe-SF6, ukuguguleka koqhagamshelwano, ukubalwa kokusebenza, kunye neeprofayili zobushushu zenza kube nokwenzeka ukuba iziphuli zesekethe zangaphandle ze-SF6 zibe zedijithali. Ezi nkqubo zokulandelela imeko zithumela idatha kumaqonga e-SCADA zisebenzisa iiprotokholi ze-IEC 61850. Oku kuvumela uhlalutyo lokuqikelela ukufumana iipatheni zokuguguleka kunye nokukrazula iinyanga ngaphambi kokuba zenzeke. Iideshibhodi zolawulo lweeasethi ezisekelwe kwilifu ziqokelela idatha yokusebenza yeenqwelo-moya zonke, okwenza kube lula ukugcina iindawo ezingasetyenziswayo kwaye zicwangcise ukulungiswa kwamaxesha apho iinqwelo-moya zingasebenzi. UXi'an Xikai udibanisa uyilo olulungele igridi ehlakaniphileyo kunye neepakethe zezinzwa zemodyuli. Oku kukhusela ukufakwa kwimigangatho yoqhagamshelwano etshintshayo kwaye kuzigcina zihambelana neenkqubo zolawulo ezindala.

Ukuhlanganiswa neeGridi ezikrelekrele kunye neMithombo yamandla aHlaziyiweyo

Ii-transmission breakers kufuneka zijongane nemijikelo emininzi yokutshintsha kunye neemfuno zolawulo lwamandla asabelayo kuba iifama zomoya kunye nelanga zivelisa umbane oguquguqukayo. Ezi mfuno zinokufezekiswa zii-SF6 circuit breakers zanamhlanje zangaphandle ezinemilinganiselo engcono yokunyamezela koomatshini (udidi lwe-M2: imisebenzi eyi-10,000) kunye nokukwazi ukutshintsha phakathi kwee-capacitors kunye nee-reactors. Ukulungelelanisa neenkqubo zokugcina amandla ebhetri kufuna ukuvumelanisa ngokuchanekileyo kunye nokuchonga iimpazamo, okunokwenziwa ngeeyunithi zolawulo ezisekwe kwi-microprocessor kunye neemonitha zangoku ze-fiber-optic. Njengoko kongezwa izixhobo ezininzi zegridi, iikhrayitheriya zokukhetha ii-breaker zigxila ngakumbi kwiimpawu ezixhasa ukhuseleko lwe-cyber, ukuhambelana kweprotocol yonxibelelwano, kunye nolawulo olukude olunceda ngamaqhinga okudibanisa izixhobo zamandla ezisasazwe.

ibhlog-1-1

isiphelo

Ukuze ukhethe eyona breaker yesekethe ye-SF6 ene-voltage ephezulu, kufuneka ucinge ngendlela esebenza kakuhle ngayo ngobuchwephesha, indlela eyiphatha kakuhle ngayo indalo esingqongileyo, kunye nokuba ibiza malini ubomi bayo bonke. Izisombululo ze-outdoor SF6 circuit breaker ziye zabonakala zithembekile kwiinethiwekhi zothumelo kuba zinokuphazamiseka okungcono kwe-arc, uyilo oluncinci, kwaye zifuna ulondolozo oluncinci. Abaphathi beziko, iinjineli zezixhobo, kunye neenkampani ze-EPC banokukhetha izixhobo ezihlangabezana neemfuno zomthetho kwaye zandise ixesha lokusebenza kwegridi ngokuqonda imigaqo yokusebenza, ukuthelekisa ubuchwepheshe obahlukeneyo, kunye nokubeka imigangatho yokuthenga engqongqo. Ukusebenza nabavelisi abanamava amaninzi kuqinisekisa ukuba unokufumana iimpahla eziqinisekisiweyo zomgangatho, uncedo lobuchwephesha olukhawulezileyo, kunye nezisombululo ezihlala ixesha elide ezihambelana nemigangatho yoshishino etshintshayo.

FAQ

1. Ingakanani ixesha eliqhelekileyo lobomi besixhobo sokwaphula isekethe sangaphandle se-SF6?

Ukuba uqhubeka nokulungisa, ii-SF6 circuit breakers zangaphandle zinokuhlala iminyaka engama-30 ukuya kwengama-35 xa zisetyenziswa ngendlela eqhelekileyo. Uvavanyo lokunyamezela koomatshini luhlala luthembisa imisebenzi eyi-10,000, ngelixa ukunyamezela kombane kugubungela ukuphazamiseka kwempazamo engama-50 ukuya kwe-100, kuxhomekeke kubukhulu bombane. Ukujonga rhoqo uxinzelelo lwe-SF6 kunye nokulandela izicwangciso zokulungisa zomenzi kuya kwenza inkqubo ihlale ixesha elide.

2. Ngaba ii-SF6 circuit breakers zangaphandle zingahlaziywa okanye ziphinde zisetyenziswe?

Ngokutshintsha i-interrupter, ukulungisa igesi ye-SF6, kunye nokulungiswa kwezixhobo zoomatshini, iinkqubo zokubuyisela ezipheleleyo zibuyisela ii-SF6 circuit breakers ezindala zibuyele kwimeko yazo yokuqala. Ekupheleni kwexesha lazo lokusetyenziswa, ukuqhaqha okulawulwayo kuvumela igesi ye-SF6 ukuba ibuyiselwe (ukuya kuthi ga kwi-99% yayo inokusetyenziswa kwakhona), iintsimbi ziphinde zisetyenziswe, kwaye i-ceramic iphinde icutshungulwe. Oku kuxhasa uqoqosho olujikelezayo kwaye kunciphisa impembelelo yokusingqongileyo.

3. Ziziphi izinto ezibalulekileyo ekufuneka ziqwalaselwe xa kufakwa?

Ukuvezwa kwe-arc flash ngexesha lovavanyo lokugunyazisa, ukwenzakala kokuphakamisa okuvela kwiindibano ezinzima (iipali ze-LW25 zinobunzima obungaphezulu kwe-1,200 kg), kunye neengozi zokufunxa i-SF6 kwiindawo ezivalekileyo zezinye zeengozi eziza nokufakelwa. Ngaphambi kokuba uvule umbane, amaqela afanelekileyo kufuneka akhuphe umbane, anxibe izixhobo zokhuseleko ezifanelekileyo, ajonge ukuvuza kwegesi emva kokuhlanganiswa, kwaye enze uvavanyo lokumelana nombane ophezulu ngokwemigangatho ye-IEEE/IEC.

Sebenzisana neXi'an Xikai kwizisombululo ezithembekileyo zeVoltage ephezulu

Ukukhetha umthengisi we -SF6 circuit breaker ofanelekileyo kubalulekile kwimpumelelo yeprojekthi kunye nokugcina ukuthembana kokusebenza ixesha elide. I-Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. ibisenza izinto kangangeminyaka emininzi, ineenkqubo ezisemgangathweni eziqinisekisiweyo yi-ISO, kwaye inembali yempumelelo kumacandelo oncedo, amashishini, kunye namandla aluhlaza. I-LW25 Outdoor Porcelain Type SF6 Circuit Breaker yethu yenzelwe iinkqubo ze-126kV/145kV kwaye inexabiso elifikelela kwi-4000A. Inika isiseko sakho segridi ukuqina, ukhuseleko, kunye nokulungeleka kwegridi ekrelekrele ekudingayo. Sinikezela ngeengcebiso zobugcisa ezipheleleyo, iikowuteshini zokhuphiswano, kunye nenkxaso iiyure ezingama-24 ngosuku, iintsuku ezisixhenxe ngeveki ukunciphisa ixesha lokungasebenzi kunye nokunyusa ixabiso lotyalo-mali lwakho. Ungathumela i-imeyile kwiingcali zethu zokuthenga ku-serina@xaxd-electric.com , amber@xaxd-electric.com , okanye luna@xaxd-electric.com ukuze uthethe ngeemfuno zakho kwaye ujonge izisombululo ezenziwe ngokwezifiso ezivela kumenzi we-SF6 circuit breaker othembekileyo.

ibhlog-1-1

Ucaphulo

1. IEEE Std C37.04-2018, "Umgangatho we-IEEE weeNqanaba kunye neeMfuno ze-AC High-Voltage Circuit Breakers ezineVoltage ephezulu eLinganisiweyo ngaphezu kwe-1000 V," i-Institute of Electrical and Electronics Engineers, eNew York, ngo-2018.

2. IEC 62271-100:2021, "Iswitshi ye-high-voltage kunye ne-controlgear - Icandelo 100: I-Alternating current circuit-breakers," IKhomishini ye-International Electrotechnical Commission, eGeneva, 2021.

3. Browne, TE, "Ukuphazamiseka Kwesekethe: Ithiyori kunye neeTekhnoloji," uMarcel Dekker Inc., eNew York, ngo-1984.

4. Ryan, HM, "Ubunjineli kunye noVavanyo lweVoliti ephezulu," Uhlelo lwesi-3, iZiko loBunjineli kunye neTekhnoloji, eLondon, ngo-2013.

5. Smeets, RPP, et al., "Ukutshintsha kwiiNkqubo zoThumelo noSasazo loMbane," uJohn Wiley & Sons, eChichester, 2015.

6. URamirez-Niño, J., kunye noPascacio, A., "IiSF6 Circuit Breakers: Theory, Design, and Application," uSpringer Nature, Cham, 2020.