I-Vacuum Circuit Breaker: Ukusebenza kunye nezicelo zayo

2026-08-10 10:58:37

Isixhobo sokwaphula isekethe ye-vacuum sisixhobo sokukhusela esithintela i-fault currents ngokucima ii-arcs zombane ngaphakathi kwigumbi lokwaphula elivaliweyo. Ngokungafaniyo nee-breakers zemveli ezisekelwe kwi-oyile okanye emoyeni, ezi zixhobo zisebenzisa iipropati eziphezulu ze-dielectric ze-vacuum ukuze zikwazi ukwahlula ngokukhawuleza iimpazamo kwiinkqubo zamandla aphakathi. Zisetyenziswa kakhulu kwizikhululo zamandla, kwizityalo zoshishino, nakwiindawo zokufakelwa kwamandla ahlaziyekayo, zinika ukuthembeka okugqwesileyo ngelixa zinciphisa impembelelo yokusingqongileyo. Ukuqonda indlela ezi breakers ezisebenza ngayo kunye nendawo ezigqwesa kuyo kunceda abaqhubi bezakhiwo, iinkampani zeenkonzo, kunye neenkampani zobunjineli ukuba benze izigqibo zokuthenga ezinolwazi ezikhusela iziseko ezibalulekileyo kunye nokwenza ngcono ixesha lokusebenza.

ibhlog-1-1ibhlog-1-1

Ukuqonda iiVacuum Circuit Breakers: Imigaqo yokusebenza kunye neenxalenye eziphambili

Yintoni Eyenza Ubuchwepheshe Bokugalela Inkunkuma Bube Bongameleyo

Kukho iswitshi yokhuseleko ebizwa ngokuba yi-vacuum circuit breaker ethintela i-fault currents ngokukhupha ii-arcs zombane ngaphakathi kwigumbi le-vacuum. Ezi zixhobo zahlukile kwii-breakers eziqhelekileyo ze-oyile okanye zomoya kuba zisebenzisa iipropati ze-dielectric ezingcono ze-vacuum ukufumana ngokukhawuleza iingxaki kwiintambo zombane ze-medium-voltage. Zisetyenziswa kakhulu kwizikhululo zamandla, kwizityalo zoshishino, nakwiinkqubo zamandla aluhlaza kuba zithembekile kakhulu kwaye azinampembelelo ingako kwindalo esingqongileyo. Ukwazi indlela ezi breakers ezisebenza ngayo kunye nendawo ezisebenza kuyo ngcono kunceda abaphathi bezakhiwo, iinkampani zeenkonzo, kunye neenkampani zobunjineli ukuba benze izigqibo zokuthenga ngobulumko ezikhusela iziseko ezibalulekileyo kwaye zonyusa ixesha lokusebenza.

Eyona nto ilungileyo ngee-vacuum interruptors kukuba zinokukhupha ii-arcs ngokukhawuleza kunayo nayiphi na enye into. Xa ii-contacts ziqhekeka ngexesha lemeko yempazamo, i-arc ivela kwi-vacuum apho ii-electron kunye nee-ions zijikeleza ngokukhawuleza kwaye zilahlekelwa ngamandla. Ukuba akukho moya okanye iimolekyuli zegesi zokugcina i-plasma isebenza, i-arc izimela yodwa kwi-milliseconds, okanye ngesiqhelo ngaphantsi kwesiqingatha somjikelo kwi-frequency ye-50Hz. Oku kuma ngequbuliso kugcina ii-contacts kwaye zikhusele ngeenxa zonke kuzo ekonakalisweni bubushushu, nto leyo eyandisa kakhulu ubomi obuluncedo besixhobo.

Izinto Eziphambili Eziqhuba Ukusebenza

Iyunithi eqhelekileyo yenziwe ngamacandelo aliqela asebenzisana kakuhle. I-vacuum interrupter inezihlanganisi eziqinileyo nezishukumisayo ezivalelwe ngaphakathi kweglasi okanye kwibhokisi yeseramikhi. Oku kugcina uxinzelelo lwe-vacuum lungaphantsi kwe-10⁻⁴ Pa. Indlela yokusebenza, edla ngokuba yinkqubo enesipringi, inika izihlanganisi amandla oomatshini eziwadingayo ukuze zihlukane ngokukhawuleza ngexesha lokufunyanwa kwempazamo. Izitshintshi zokukhusela zithumela imiqondiso kwiikhoyili ezikhubekayo, ezithi emva koko ziphendule. Isakhelo sokukhusela sigcina iindawo eziphilayo zingachukumisi ibhokisi. Iintlobo zanamhlanje zisebenzisa iipali eziqinileyo ezenza ukuba zikwazi ukumelana nongcoliseko. Oku kuluncedo ngakumbi kwiifektri ezinothuli okanye kwiindawo eziselunxwemeni apho inkungu yetyuwa ikhawulezisa ukuwohloka.

Inkqubo Yokuphela Kwe-Arc Ichaziwe

Xa yonke into isebenza ngokuqhelekileyo, oonxibelelwano be -vacuum circuit breaker bahlala bevaliwe, kwaye umbane olinganisiweyo uhamba kuzo ngaphandle kokumelana okukhulu. Inkqubo yokhuseleko ithumela isignali yokuhamba kwindlela yokusebenza xa kukho umjikelo omfutshane. Njengoko umbane uqhubeka uhamba ngomphunga wesinyithi oxutywe ne-ion, oonxibelelwano bayaqhekeka ngokukhawuleza, benze i-arc yokuqala. Le arc ilahlekelwa ngamandla ngokukhawuleza kwigumbi lokukhupha kuba ii-electron azikwazi ukubetha iimolekyuli zegesi ukugcina i-plasma iqhubeka. Xa ukuwela kombane wendalo ongenanto kwenzeka kwiinkqubo ze-AC, i-arc iyacima ngokupheleleyo, kwaye amandla e-dielectric e-vacuum abuya phantse ngoko nangoko. Oku kugcina i-arc ingaqali kwakhona, nokuba kukho ii-voltages eziphezulu zokubuyisela ezidlulayo. Le nkqubo iqinisekisa ukuba amandla okuqhekeka ahlala efana kwiinkqubo ezingamawaka ngaphandle kokugcinwa.

Iingenelo zeVacuum Circuit Breakers ngaphezu kwezinye iintlobo

IiMfuno zoLungiso oluNcinane

Ngokungafaniyo neziphuli zesekethe yeoyile ezifuna ukutshintshwa ioyile yazo rhoqo kunye neeyunithi ze-SF6 ezifuna ukubekwa esweni koxinzelelo lwegesi, uyilo olusekwe kwi-vacuum aludingi kugcinwa iminyaka emininzi. I-sealed interrupter igcina oonxibelelwano lungagqwali kwaye lungcole, ngoko akufuneki zicocwe okanye zilungiswe. Le nzuzo iyathandwa ngabaphathi beziko kumaziko edatha nakwiifektri kuba inciphisa ixesha lokungasebenzi elicwangcisiweyo kwaye yehlisa iindleko zizonke zobunini. Iindawo zoomatshini, ezifana nezipringi kunye neekhonkco, zifuna ukuvavanywa kuphela rhoqo emva kwezenzo ezingama-2,000, okanye kwiminyaka emithathu ukuya kwemihlanu. Oku kuncinci kakhulu kunezinye iiteknoloji.

IiNzuzo zokusiNgqongileyo noKhuseleko

Ngenxa yokuba akukho oyile inokutsha, akukho mingcipheko yomlilo kwiiswitshi ezindala ezibhedlele nakwizakhiwo zoshishino. Xa ii-SF6 circuit breakers zivuza, zikhupha iigesi ezinamandla zokufudumala. Kwelinye icala, iteknoloji ye-vacuum ayikhuphi naluphi na ukukhutshwa xa isetyenziswa okanye xa ilahlwa. Ngenxa yoxinzelelo lolawulo lokuphelisa i-SF6, iinkampani zeenkonzo ezifuna ukuhlangabezana neenjongo zazo zokuzinza ziya kuba nomdla ngakumbi kwizisombululo ze-vacuum. Ii-enclosures ezincinci zentsimbi, ezifana nezo zikwi-ZW32-40.5 series, zinokumelana nemozulu embi ngaphandle kumaqondo obushushu aqala kwi--40°C ukuya kwi-+60°C kwaye zisenokhuseleko lokungena kwe-IP67. Oku kuzenza zilungele iindawo zamandla avuselelekayo ezifumana uthuli oluninzi kunye nokufuma.

Ukusebenza Okugqwesileyo Ekutshintsheni Okuvamileyo

Ii-breakers ezinokusingatha amaxesha amaninzi okutshintsha ngonyaka ngaphandle kokuqhekeka ziyafuneka kwimithwalo yemizi-mveliso efana nee-motor drives kunye nee-capacitor banks. Lo ngumsebenzi omhle kwii-vacuum interruptors kuba ii-contacts zazo ziyaphela kancinci rhoqo xa zisetyenziswa. Imodeli ye-ZW32-40.5 inobomi boomatshini obungaphezulu kwe-10,000 yezenzo kwaye inokusingatha umbane oqhubekayo we-630A kwi-12kV kunye ne-25kA fault currents. Olu kuqina lubaluleke kakhulu kwiindawo ezifana nee-steel mills kunye nee-arc furnaces apho iingxaki zomgangatho wamandla zithetha ukuba amanyathelo okhuseleko kufuneka athathwe rhoqo. Xa iinkampani zobunjineli zichaza i-switchgear yezi ntlobo zokusetyenziswa, amabango ewaranti ayawa kwaye izinto zihlala ixesha elide.

Izicelo kunye nexesha lobomi beVacuum Circuit Breakers kwiindawo zoshishino

IiNethiwekhi zokuSasaza amandla

Ii-vacuum circuit breakers ze-medium-voltage zisetyenziswa ziinkampani ezincedisayo kwizikhululo zokuhambisa nokuhambisa ukuze zifumane iingxaki. I-ZW32-40.5 ingafakwa kwiindawo ezinesithuba esincinci kuba inesithuba esincinci. Indlela yayo yokuvula iqinisekisa ukuba iimpazamo ziyamiswa ngokukhawuleza (ngaphakathi kwee-millisecond ezingama-50), ikhusela izixhobo ezisezantsi komgca ekuweni kwe-voltage. Amaqhosha okwahlula akhethiweyo akhelwe kuyilo enza ukugcinwa kube lula ngokwenza iindawo zokuqhawula zibonakale. Oku kwenza inkonzo ikhuseleke ngakumbi kubasebenzi. Ezi yunithi zigcina i-voltage kwigridi izinzile xa ii-harmonics zenziwe zii-variable frequency drives kunye nemithombo yamandla eluhlaza esebenzisa ii-inverters.

Izixhobo zokwenziwa kwemizi-mveliso

Izakhiwo zemveliso zifuna umbane ongacimiyo ngoko ke akufuneki zihlawule imali eninzi ngexesha lokungasebenzi. Kukho izixhobo ze-elektroniki ezibuthathaka kwiindawo zoomatshini be-CNC, imigca yokuhlanganisa ezenzekelayo, kunye nezixhobo zokubumba inaliti ezinokonakala ngenxa yotshintsho kumgangatho wamandla. Xa injini iqala, imisinga yokunyuka ifikelela kwi-100 amandla aphezulu anokuhamba kule mithwalo, kodwa ukhuseleko lwe-vacuum luyayikhusela. Uyilo lwemodyuli luvumela ukusebenza komntu kunye nolwekude, kwaye lunokuqhagamshelwa kwiinkqubo zolawulo lokulawula ukuze ukucinywa komthwalo kulungiselelwe ngamaxesha emfuno ephezulu. Ii-sensors ze-IoT ezikhethiweyo ezilandelela ubushushu boqhagamshelwano kunye nomgama wokuhamba ziluncedo ekuxilongweni ngamaqela olondolozo. Oku kubavumela ukuba bacwangcise kwangaphambili iimfuno zolondolozo.

Ufakelo lwaMandla aVuselelwayo

Iifama zelanga kunye nezitishi ze-wind turbines zikwiindawo ezikude apho ukuthembeka kunye nokugcinwa okuncinci kubaluleke kakhulu. Uyilo olulinganiswe ngaphandle lusebenzisa izindlu zentsimbi ezingamelani nokugqwala ezinokusingatha ityuwa ephuma elunxwemeni kunye nezivuthuvuthu zesanti entlango. Iimodeli ezilungele igridi ehlakaniphileyo ezinee-interface zonxibelelwano zithumela idatha yokusebenza ngexesha langempela kumaqonga okulandelela aphakathi, nto leyo enciphisa isidingo sokuhlolwa ekufuneka kwenziwe kwindawo. Xa iifama zomoya zingaphezulu kwe-1,000 yeemitha, unxibelelwano olungcono phakathi kwe-insulation luthintela i-flashover ukuba ingenzeki emoyeni omncinci, apho amandla ombane ehla khona. Le teknoloji inceda ezi ndawo kuba inokusingatha iipateni zemveliso ezifikayo nezihambayo, ezibangela utshintsho oluninzi lwexesha.

Kwiimeko eziqhelekileyo zokuvelisa, iiyunithi ezinakekelwa kakuhle kufuneka zihlale phakathi kweminyaka engama-25 ukuya kwengama-30. Uhlobo lomthwalo lunefuthe elikhulu ekubeni into ihlala ixesha elingakanani. Umzekelo, izixhobo ezikhusela imithwalo engashukumiyo, ezifana neetransformers, ziguga ngokukhawuleza kunezo zitshintsha iisekethe zeemoto. Izinga lokuguga kwe-insulation lichaphazeleka zizinto ezifana nobushushu, ukufuma, kunye nenqanaba lokungcola emoyeni. Ukujonga umgama wokuhamba koqhagamshelwano, ukulinganisa ukumelana koqhagamshelwano, kunye nokusebenzisa iimvavanyo zokumelana nombane ophezulu ukubonisa ukuthembeka kwe-vacuum zonke kufuneka zibe yinxalenye yeenkqubo zokuhlola rhoqo. Ukusebenzisa ezi ndlela kunceda abaphathi bokuthenga bafumane imbuyekezo engcono kutyalo-mali lwabo kwaye bagcine izinto ezibalulekileyo zikhuselekile ngamaxesha onke.

Indlela yokukhetha i-Vacuum Circuit Breaker efanelekileyo kwiimfuno zakho zokuthenga

Ukhetho lweVoltage kunye neRating yangoku

Ingcaciso efanelekileyo iqala ngokufanisa i-voltage elinganisiweyo neemfuno zenkqubo. Amaxabiso e-voltage ephakathi ahlala ebonwa yi-12kV, 24kV, kunye ne-40.5kV. Umgca we-ZW32-40.5 unokusingatha zombini ii-voltage zenkqubo ze-12kV ezizimeleyo kunye ne-40.5kV eziphezulu. I-current elinganisiweyo kufuneka ibe phezulu kune-load current eqhelekileyo, kwaye kufuneka kubekho indawo eyaneleyo yokukhula kwixesha elizayo. I-rating ye-630A isebenza kwii-feeders ezininzi zemizi-mveliso kunye nee-transformers zokusasaza. Umthamo wokuqhekeza, onikwe kwi-kA, kufuneka ufane okanye ube mkhulu kune-current ye-short-circuit ephezulu kwindawo yokufakela. Ukulinganiswa okungaphantsi kwale parameter kunokukhokelela ekungaphumeleli okukhulu ngexesha leemeko zempazamo, okunokubeka abantu engozini kwaye konakalise izixhobo ezikufutshane.

Ukuvavanya ukuthembeka kunye nenkxaso yebhrendi

Iimpawu zehlabathi ezifana neSiemens, ABB, kunye neSchneider Electric bezikho ixesha elide kwaye zinenethiwekhi zenkonzo kulo lonke elase-United States. Iimpahla zabo ziyahambelana nemigangatho ye-IEC 62271-100 kunye ne-IEEE C37.04, oko kuthetha ukuba zinokusebenza neenkqubo zangoku. Kodwa ngenxa yokuba zenziwe phesheya, amaxesha okufumana izinto adla ngokuya kwiiveki ezingama-20. Ababoneleli basekhaya banikezela ngoncedo lokuthumela ngokukhawuleza kunye noncedo lweengcali olukufutshane nekhaya, kodwa abathengi kufuneka bajonge ngononophelo iziqinisekiso zababoneleli kunye nemigaqo yewaranti. Umzi-mveliso weXi'an Xikai unendawo eninzi kunye neenzuzo ezininzi zokukhuphisana, ezifana neepatenti ezingaphezu kwama-40 kwitekhnoloji ye -vacuum circuit breaker , ukuhlanganiswa ngokuthe nkqo kwezinto ezibalulekileyo, kunye nenkxaso yobugcisa ekhoyo iiyure ezingama-24 ngosuku, iintsuku ezisixhenxe ngeveki, kunye neenkqubo zoqeqesho kwindawo.

Iingqwalasela zeChannel yoThengo

Xa usebenza ngokuthe ngqo nabenzi bee-vacuum circuit breaker, ungafumana ulwazi olucacileyo lwamaxabiso kunye nesiqinisekiso sokwenyani. Abasasazi bongeza ixabiso ngokudibanisa izinto zokusebenza kunye nokunciphisa ubungakanani obuncinci be-odolo, nto leyo eluncedo kumashishini aphethe iiprojekthi ezininzi ezineemfuno ezahlukeneyo. Xa ujonga imithombo eyahlukeneyo, qiniseka ukuba banesatifikethi solawulo lomgangatho we-ISO 9001 kwaye ucele iziphumo zovavanyo ezibonisa amandla e-dielectric, ukunyamezela koomatshini, kunye nokuqinisekiswa koxinzelelo lokusingqongileyo. I-ZW32-40.5 idlula kwiimvavanyo ezinzima ezingama-23, njengobungqina bokukwazi kwayo ukuphatha amandla angama-80kV kunye nokulinganisa ukusebenza kwiimeko zobushushu obuphezulu. Abathengi kufuneka bajonge nenkxaso yenkampani emva kokuthengisa. Ukuhanjiswa ngokukhawuleza kweendawo ezingasetyenziswayo kunye nokufumaneka kwenkonzo yasentsimini kuchaphazela ngokuthe ngqo amandla enkampani okuqhubeka isebenza ngexesha lokucima okungacwangciswanga.

Ukusombulula iingxaki, imiba eqhelekileyo, kunye neendlela zexesha elizayo kwi-Vacuum Circuit Breakers

Imiba yokuSebenza eqhelekileyo

Ukulahleka kwe-vacuum lolona hlobo luyingozi lokusilela, kodwa iindlela zangoku zokwenza izinto ziyenze yanqabile kakhulu. Amandla okuphuka okuncinci kunye nokubonakala okubonakalayo ngaphandle kwe-interrupter ngelixa isebenza ziimpawu. Uvavanyo oluqhelekileyo lwe-high voltage lufumanisa ukuba ukubola kunye nokukrazuka ngaphambi kokuba kukhokelele ekusileleni okubi kakhulu. Nangona ukukrazuka kokunxibelelana kungekubi njengakwi-air breakers, kusafuneka kutshintshwe emva kokuphazamiseka kombane okuninzi—ngesiqhelo i-50 ukuya kwi-100 xa umthamo wayo uphelele. Iingxaki zoomatshini kwinkqubo yokusebenza zibonakala njengokusebenza kancinci okanye ukusilela ukuvala. Ezi ngxaki zihlala zibangelwa ziindawo ezihambayo ezingafakwanga ioyile kakuhle okanye ukuvala izipringi ezingomelelanga ngokwaneleyo. Ukuqinisekisa ukuba ikhoyili isebenza ngokufanelekileyo, iinkqubo zokuhlola kufuneka zijonge ukuba i-voltage yokulawula yesibini ihlala phakathi kwe-85% kunye ne-110% ye-voltage elinganisiweyo.

IziCwangciso zokuThintela zokuLondoloza

Ukuseta amaxesha okuhlola ngokusekelwe kwimijikelo yokusebenza endaweni yemihla yekhalenda kusebenzisa kakuhle izixhobo zokulungisa. Izixhobo ezivula kwaye zicima izinto kakhulu kufuneka zijonge oonxibelelwano rhoqo emva kwemisebenzi eli-1,000. Kwizinto ezifakelweyo ezingashukumiyo, ixesha eliphakathi kokuhlolwa linokwandiswa ukuya kwiminyaka emihlanu. Ngokusebenzisa izalathisi zokudayela ukulinganisa umgama wohambo lonxibelelwano, ukuguguleka kunokufunyanwa ngaphambi kokuba kuchaphazele ukusebenza. Iiskena zeThermographic zifumana iindawo ezishushu ezibangelwa ziikhonkco ezingaqinanga ngokwaneleyo okanye ezinokumelana kakhulu nonxibelelwano. Ukugcina iirekhodi zenkonzo ezineenkcukacha kukuvumela ukuba ujonge iipateni ezikuxelela ukuba iindawo ziya kwaphuka nini. Ngale ndlela, ungazitshintsha ngaphambi kokuba ziqhekeke ngexesha lokungasebenzi okucwangcisiweyo endaweni yokwenza ukulungiswa okungxamisekileyo ngexesha lotshintsho lwemveliso.

Uphuhliso lweTekhnoloji oluPhumayo

Inyathelo elilandelayo eliya phambili kwiteknoloji yeswitchgear kukukwazi kwayo ukuqhagamshela kwizikhululo zedijithali kunye neenkqubo ze-IoT zezeMveliso. Izinzwa ezifakiweyo zijonga iipateni zokushukuma, iiprofayili zobushushu, kunye nenani lezihlandlo into esebenza ngazo. Zithumela olu lwazi kwiinkqubo zolawulo lweeasethi eziphambili zisebenzisa iiprotokholi ze-IEC 61850. Ii-algorithms zokufunda koomatshini zijonga le datha ukuze zifumanise ukuba into inokuhlala ixesha elingakanani kwaye kufuneka ilungiswe nini. Injongo yophuhliso olutsha kuyilo lwe-vacuum interrupter kukwenza oonxibelelwano bahlale ixesha elide ngokuphucula imo ye-metallurgy kunye ne-magnetic field. Oku kuya kubavumela ukuba banyamezele iimpazamo ezingaphezu kwe-100. Njengoko iindawo ezininzi zibeka imida kwi-SF6, imithetho yokusingqongileyo iyaqhubeka nokukhuthaza ukwamkelwa. Umzekelo, umthetho we-F-gas we-European Union kunye neemfuno zengxelo yegesi ye-greenhouse yaseCalifornia zikhawulezisa intshukumo eya kwi-vacuum circuit breakers kunye nezinye iindlela ezisekelwe emoyeni.

ibhlog-1-1

isiphelo

Ii-vacuum circuit breakers zezona ndlela zithembekileyo zokukhusela iinkqubo ze-medium-voltage kwicandelo leenkonzo, ishishini, kunye nezoshishino. Iingenelo zazo zokusingqongileyo, ukukwazi ukusebenza ngaphandle kokugcinwa, kunye nobomi obude bokutshintsha izinto zihlangabezana neemfuno eziphambili zabaphathi bezakhiwo abafuna ixesha eliphezulu lokusebenza kunye nabaphathi bokuthenga abaxhalabele iindleko zomjikelo wobomi. I-ZW32-40.5 ngumzekelo omhle woyilo lwanamhlanje kuba yenziwe ngentsimbi encinci, isebenza ngeegridi ezikrelekrele, kwaye idlule ekuhlolweni okungqongqo komgangatho. Njengoko iinkqubo zamandla zitshintsha ukuze zibandakanye amandla ahlaziyekayo ngakumbi kunye nokulandelela kwedijithali, kuba kubaluleke ngakumbi kunangaphambili ukukhetha ubuchwepheshe obufanelekileyo kunye nobudlelwane bomthengisi. Xa ujonga ngononophelo ukulinganiswa kwe-voltage, amandla okuphuka, ukuthotyelwa kwesatifikethi, kunye nenkxaso emva kokuthengisa, unokuqinisekisa ukuba izigqibo ozenzayo malunga nokuba uza kuthenga zikhusela zombini iimfuno zokusebenza zexesha elifutshane kunye neenjongo zesicwangciso sexesha elide.

FAQ

1. Ukuphakama kuyichaphazela njani indlela esebenza ngayo i-vacuum circuit breaker?

Iiyunithi ezisemgangathweni zisebenza ngokuthembekileyo ukuya kuthi ga kwi-1,000 yeemitha, njengoko usiya ngaphezulu kweli nqanaba, uxinzelelo oluphantsi lomoya lwenza amandla okukhusela umoya wangaphandle abe buthathaka. Ukuze kuthintelwe ukuqhambuka kwe-flashovers, ukufakelwa kwendawo ephakamileyo, njengaleyo ikwiifama zomoya ezintabeni okanye kwizikhululo zeenduli, kufuna ukulungelelaniswa okungcono koyilo lwe-insulation okanye lweepali ezineziqina ezifakiweyo kuzo. I-ZW32-40.5 yenzelwe ukusebenza kwezi meko ngokuba nobude obude bokuqhekeka kunye nezixhobo zokukhusela ezinamandla. Abavelisi badla ngokunciphisa amandla okuqhekeka nge-1% kwi-100 yeemitha nganye ngaphezulu kwe-1,000 yeemitha, okanye banikezela ngeenguqulelo ezikhethekileyo zendawo ephakamileyo ezivavanyiweyo phantsi koxinzelelo oluphantsi. Ngexesha lenkqubo yokuthenga, abathengi kufuneka bachaze ukuphakama kwendawo ukuqinisekisa ukuba kwenziwe ubunjineli obuchanekileyo.

2. Ngaba ezi breakers zingakwazi ukujongana nokutshintsha rhoqo kwe-capacitor bank?

Xa zibizwa ngokuba yiClass C2 ngokwemigangatho ye-IEC, iziphazamisi ze-vacuum circuit breaker zilungile ekutshintsheni i-capacitive. Ukuphazamisa i-capacitive currents kunokubangela ii-voltage transients eziphezulu, nto leyo eyenza kube nzima kakhulu ukusebenza ngazo. Ngokusebenzisa izixhobo zokuchukumisa ezilungileyo kunye nesimo segumbi lokuphazamiseka, uyilo olusemgangathweni lunciphisa amathuba okuphinda kutsha. Ixesha elifutshane lokuphela kwe-arc ye-ZW32-40.5 (ngaphantsi kwe-50 milliseconds) ligcina ii-capacitors zikhuselekile kuxinzelelo lwe-overvoltage ngelixa kusenzeka utshintsho. Olu phawu luluncedo kwiindawo zoshishino ezisebenzisa izixhobo ukulungisa izinto zamandla kunye neendawo zamandla aluhlaza ezisebenzisa i-inverter-based generation. Amaxesha okulungisa ahlala efana nokuba umthwalo uyathintela okanye uyabangela ukungasebenzi kakuhle kuba akukho kukhukuliswa koqhagamshelwano okuninzi ngexesha lokusebenza.

3. Ukuphakama kuyichaphazela njani indlela esebenza ngayo i-vacuum circuit breaker?

Ii-vacuum circuit breakers eziqhelekileyo zisebenza ngokuthembekileyo ukuya kuthi ga kwi-1,000m ngaphezu kolwandle. Ngaphezulu kolu kuphakama, uxinzelelo oluphantsi lomoya luthintela ukusebenza kwe-insulation yomoya yangaphandle, okwandisa amathuba okutshayelwa yi-flashover. Kwiifektri zomoya eziphakamileyo (umz. iifama zomoya zentaba okanye izitishi zentaba) abavelisi badla ngokunciphisa amandla okutshayelwa yi-1% kwi-100 m nganye ngaphezulu kwe-1,000m, okanye banike uyilo olukhethekileyo oluneemigama ezinde zokutshayelwa kunye nezixhobo zokukhusela eziqinisiweyo (njengoko kuphawuliwe kwi-ZW32-40.5 series). Umthengi kufuneka anike ukuphakama kokufakelwa ngexesha lokuthenga ukuqinisekisa ukulungelelaniswa okuchanekileyo kwe-insulation kunye nokuthintela ukwehla kokusebenza.

Sebenzisana noXi'an Xikai kwiProjekthi yakho elandelayo yeSwitchgear

Xa kufikwa kwiindlela zombane ophakathi, iXi'an Xikai Medium & Low Voltage Electric inamava eminyaka emininzi kwaye ihlala iza neengcinga ezintsha. Ii -vacuum circuit breakers zethu ze-ZW32-40.5 series zisebenzisa itekhnoloji yokuphazamiseka evavanyiweyo kunye neempawu zokulandelela ezihlaziyiweyo ukuze zisebenze kwiindawo ezahlukeneyo ezifuna amandla, ukusuka kwizikhululo zeState Grid ukuya kwiifama zomoya ezikude kwiimitha ezingama-4,000 ngaphezu komphakamo wolwandle. Iipatenti ezininzi zikhusela ukusebenza okuhlangabezana nemigangatho yamazwe ngamazwe, kwaye ukukwazi ukwenza izinto ngomlinganiselo omkhulu ngexabiso eliphantsi kwenza amaxesha eprojekthi abe bhetyebhetye. Iqela lethu lobunjineli lenza iingcebiso ngokusekelwe kwiiprofayili zakho zomthwalo kunye neemeko zokusingqongileyo, nokuba uyinkampani ye-EPC ekhetha izixhobo zeziko ledatha elitsha okanye inkampani yeenkonzo ezithatha indawo yeziseko ezindala. Ungathetha nomthengisi we-vacuum circuit breaker ofanelekileyo ngokuthumela i-imeyile ku-serina@xaxd-electric.com , amber@xaxd-electric.com , okanye luna@xaxd-electric.com , omnye weengcali zethu zokuthengisa ngobuchwephesha.

ibhlog-1-1

Ucaphulo

1. IKhomishini yeHlabathi ye-Electrotechnical. Iswitshi ye-high-voltage kunye ne-controlgear - Icandelo 100: Ii-Alternating-current circuit-breakers. IEC 62271-100:2021.

2. I-IEEE Power and Energy Society. Ulwakhiwo oluQhelekileyo lwe-IEEE lwee-AC High-Voltage Circuit Breakers. IEEE Std C37.04-2018.

3. Slade, PG I-Vacuum Interrupter: Ithiyori, Uyilo, kunye noSetyenziso. Uhlelo lwesi-2. I-CRC Press, ngo-2017.

4. Beehler, JE kunye noSmith, RK Vacuum Switchgear. IET Power and Energy Series 88. Iziko loBunjineli kunye neTekhnoloji, 2019.

5. UMbutho weSizwe woKhuselo loMlilo. I-NFPA 70: Ikhowudi yoMbane yeSizwe. Uhlelo luka-2023. Iimpapasho ze-NFPA.

6. IZiko loPhando lwaMandla oMbane. IiTekhnoloji ze-Medium-Voltage Circuit Breaker: Uhlalutyo lokuthelekisa lwezicelo zeZixhobo. Ingxelo yoBugcisa ye-EPRI 3002015890, 2020.

thumela