Yintoni i-Indoor Current Transformer kwaye isebenza njani
2026-08-07 11:33:36
I- indoor current transformer sisixhobo esichanekileyo se-electromagnetic esenzelwe ukuguqula i-high primary currents ibe yi-standard standardised secondary values for purposes and protection in the owned environments. Ezi zixhobo zisebenzisa i-electromagnetic induction ngokusebenzisa i-core-winding arrangement ukuze zinciphise i-currents ukusuka kwi-20A ukuya kwi-3150A zibe yi-outputs elawulekayo ye-1A okanye i-5A. Zifakwe kwi-epoxy resin ukuze zikhuseleke kwi-insulation, zivumela ukujonga ngokuchanekileyo iinkqubo zombane kwi-substations, kwi-industrial areas, nakwii-real facilities apho iimeko zendalo zihlala zizinzile.

Ukuqonda iiTransformers zangoku zangaphakathi: Imigaqo ephambili kunye nendlela yokusebenza
Ukuze i-transformer yangaphakathi isebenze, uMthetho kaFaraday wokungenisa i-electromagnetic ubaluleke kakhulu. Kukho i-magnetic flux ngaphakathi kwe-silicon steel core xa i-alternating current idlula kwi-main conductor. Le flux ibangela i-secondary current ehambelana nenani lee-turns kwi-primary windings kunye ne-secondary windings. I-transformer ratio ikuxelela ukuba i-original current incitshiswe kangakanani. Umzekelo, i-1000/5A ratio ithetha ukuba i-1000 amps ehamba kwii-main terminals yenza i-5 amps ngqo kwii-secondary terminals.
Indima yokungeniswa kwe-Electromagnetic kwiSilinganiselo sangoku
Zonke ii-transformers zangoku zisebenza ngokomgaqo wokungeniswa kwe-electromagnetic. Njengoko idlula kwi-magnetic core, i-primary conductor ifana ne-single-turn coil, kwaye i-secondary winding inee-turns ezininzi ezilinganiswe ngononophelo. Olu seto luqinisekisa ukuba i-main circuit akufuneki isebenze nzima ngelixa isinika amandla aneleyo okunika amandla naziphi na izixhobo ze-metering okanye ze-protective relay. I-epoxy resin casting igubungela yonke indibano, ingashiyi mingxunya yomoya enokuchaphazela ukuchaneka kwemilinganiselo okanye ibangele iingxaki ngokukhululwa okungaphelelanga.
Iintlobo zokwakha: Uqwalaselo lwe-Single-Core vs Multi-Core
Ngoyilo olune-core enye, kukho isekethe enye yemagnethi esetyenziselwa ukulinganisa okanye ukukhusela. Oku kwenza uyilo lube lula kwaye lungabizi kakhulu kwimisebenzi elula. Ii-cores ezahlukeneyo zigcinwa kwi-home efanayo kwiinguqulelo ze-multi-core, ezihlala zidibanisa amacandelo e-metering-class kunye ne-protection-class. Olu lungiselelo lusebenza kwiinjongo ezimbini, ezenza kube lula ukuzifaka kwaye zigcina ukuchaneka komlinganiselo kunye neempawu zokuphendula iimpazamo zahlukile ngokusebenzayo. I-transformer yethu yangaphakathi ye-24kV ivalwe ngokupheleleyo kwaye ihlangabezana nomgangatho wokhuseleko we-IP20. Ilungile kumagumbi ezixhobo ekufuneka agcine amanqanaba othuli kunye nokufuma ephantsi.
Iiklasi zokufaka i-Insulation kunye nefuthe lazo kwi-Voltage Rating
Iinkqubo zokwambathisa zisixelela ukuba ingakanani i-voltage stress enokuthi i-transformer yangaphakathi ikwazi ukuyiphatha ngokukhuselekileyo. Uvavanyo lwe-24kV luthetha ukuba inkqubo ingasebenza ngee-voltages ezingaqhelekanga ukuya kuthi ga kweli nqanaba. Xa kuthelekiswa ne-oil-paper insulation, i-epoxy resin casting inamandla aphezulu e-dielectric, apho imilinganiselo yokukhupha okungaphelelanga ihlala ingaphantsi kwe-10 picocoulombs ngexesha lovavanyo lohlobo. Lo msebenzi wokukhupha ophantsi uthintela ukukhupha oko kungaphuki kancinci, oko kuthetha ukuba kuya kuhlala ixesha elide ngaphezu kweminyaka engama-30 phantsi kweemeko zokusebenza eziqhelekileyo. Ukuhlangabezana neemfuno ze-IEC 61869-1 kunye ne-GB 20840.2-2014 kuqinisekisa ukuba iindawo zingasetyenziswa kwiiprojekthi ezahlukeneyo zangaphandle.
IiTransformers zangaphakathi kunye nezangaphandle: Umahluko ophambili kunye nezinto ekufuneka ziqwalaselwe xa kuthengwa
Zombini ezi ntlobo zeetransformer zilinganisa izinto ezifanayo, kodwa uyilo lwazo lwahlukile kakhulu kuxhomekeke kwindlela eziza kusetyenziswa ngayo. Ekubeni zingenangxaki yoxinzelelo olunxulumene nemozulu, iiyunithi zangaphakathi zigxila kubukhulu obuncinci kunye neendleko eziphantsi. Iintlobo zangaphandle zinezindlu ezenziwe nge-porcelain okanye izinto ezidityanisiweyo ezinemizila emide yokuthintela ukusasazeka kwemvula xa lina okanye ungcoliseko lukhula.
Ifilosofi yoKunyamezela iNdalo kunye noYilo
Iitransformer zamandla angaphakathi zisebenza kumaqondo obushushu aphakathi kwe-5°C kunye ne-+40°C kwaye kumanqanaba omswakama alawulwayo angaphantsi kwe-95% yomswakama ohambelanayo. Isakhiwo se-epoxy esivalekileyo asivumeli ukufuma okanye ukungcola okubangelwa ngumoya okuqhelekileyo kumagumbi ezixhobo ukuba kungene. Inkqubo yethu yemveliso iqinisekisa ukusebenza kobushushu phakathi kwe-40°C kunye ne-+70°C, ngoko ke ukuseta kungenziwa kwiindawo ezahlukeneyo zemozulu ngaphandle kwesidingo sokufudumeza okongezelelweyo. Iitransformer zangaphandle, kwelinye icala, zifuna izixhobo ezimelana nokukhanya kwe-UV kunye nemingxunya yokukhupha amanzi, nto leyo eyenza kube nzima ukuzenza kwaye kubize imali eninzi ukuzithenga.
Uthelekiso lweKlasi yokuChaneka kwiZicelo ezahlukeneyo
Ukuchaneka kweKlasi 0.2 okanye 0.5 kuyadingeka kwiinjongo zokuhlawulisa kwizicelo zokulinganisa, kodwa ukuchaneka kweKlasi 5P okanye 10P kulungile kwiisekethe zokukhusela kuba ukufumana iimpazamo ngokukhawuleza kubaluleke kakhulu kunokulinganisa ngokuchanekileyo. Xa kufikwa ekulinganiseni, ii-transformers zamandla angaphakathi zihlala zenza umsebenzi omhle kuba iimeko ezizinzileyo zomoya ziyeka ukushukuma kobushushu. Xa kuthengwa izixhobo zezibhedlele okanye amaziko edatha, abaphathi bokuthenga kufuneka baqinisekise ukuba izixhobo zigcina ukuchaneka kwazo kuluhlu lomthwalo oluqikelelweyo. Umzekelo, imodeli yethu ye-24kV igcina ukusebenza kwayo kweKlasi 0.2 ukusuka kwi-5% ukuya kwi-120% yamandla ayo aphambili alinganisiweyo.
Imigangatho yoKhuseleko loFakelo kunye nokuNciphisa uNgozi
Xa ukufakelwa kwenziwe ngokuchanekileyo, iingozi zombane zigcinwa kude nabantu kunye noomatshini. Iitransformer zangaphakathi kufuneka zifakwe ngokukhuselekileyo kwiiphaneli ezithe nkqo okanye ngaphakathi kwi-cubicle switchgear, kwaye iiterminals zesibini kufuneka zibe lula ukufikelela kuzo ukuze iingcingo zijongwe. Ukuba uvula iisekethe zesibini ngelixa umsinga ophambili uhamba, kuya kwenzeka ii-voltage spikes eziyingozi ezinokufikelela kwiikhilovolts ezininzi. Xa ugquma enye yeeterminals zesibini, i-capacitive coupling ayinakuphakamisa amandla kwizinto ezinokuchukumiseka ukuya kwinqanaba eliyingozi. Amaphepha ethu okufakela ahambelana nemigangatho yokusebenza yomsebenzi ye-NFPA 70E, enceda izakhiwo zoshishino ukuba ziphumelele uhlolo lokuthobela imithetho.
Indlela yokukhetha i-Indoor Current Transformer efanelekileyo kwisicelo sakho
Xa ufuna ii-transformers zangoku ezifanelekileyo, kufuneka ulinganisele iinkcukacha zobugcisa xa kuthelekiswa nohlahlo-lwabiwo mali kunye neemfuno zokusebenza. Ukuze kuhambelane neempawu zenkqubo, iingcali zokuthenga kufuneka zijonge umlinganiselo wangoku ophambili, udidi lokuchaneka, umthamo womthwalo, kunye nokukwazi ukumelana ne-short-circuit.
Ukuthelekisa uVavanyo lwangoku oluPhambili kwiiprofayili zokulayisha
Ukukhethwa kombane oyintloko kusekelwe kumthwalo ozinzileyo ophezulu kunye nomda wokukhula kwexesha elizayo. Ukuze kuchaneke ngexesha leencopho zemveliso, iifektri ezisebenzisa imigca ye-800A zinokucela ii-transformers ezilinganiswe yi-1000A. Uyilo lwe-dual-ratio luluncedo kumaziko edatha ongeza amandla ngokwamanqanaba. Iiyunithi zethu zinokutshintshwa ukuze zixhase ii-ratios ezifana ne-1500/1A kunye ne-2000/1A ngokuqhagamshela kwakhona ii-terminals, ngoko akufuneki uhlawulele ezintsha xa uhlaziya.
Ukukhethwa kweKlasi yokuChaneka kokulinganisa nokukhusela
Ngokwemigaqo ye-IEC 61869-2, ukulinganisa ingeniso kufuna ukuchaneka kweKlasi 0.2S ukusuka kwi-1% ukuya kwi-120% yokulayisha. Iitransformer zeKlasi 5P20 zisebenza kakuhle ngeeswitshi zokukhusela. I-"20" imele i-accuracy limit factor, elinani lamaxesha umbane olinganisiweyo apho iimpazamo zifikelela kwi-5%. Ukudibanisa le misebenzi mibini, kufuneka wakhe ngee-cores ezininzi okanye uthenge ii-transformers ezimbini ezahlukeneyo. I-transformer yethu yangaphakathi ye-24kV inee-cores zeKlasi 0.2 zokulinganisa kunye nee-cores zokhuseleko ze-10P emzimbeni omncinci ongaphantsi kwama-300 mm ubude.
Ukuvavanya udumo lwababoneleli kunye neziseko zoncedo
Xa ufuna ubudlelwane bexesha elide nabavelisi be-transformer yangaphakathi , nazi izinto ezibalulekileyo ekufuneka uzikhumbule:
- Ubuchule bobuchwephesha: Sebenzisa iingxelo zovavanyo lomntu wesithathu ukujonga iziqinisekiso ezifana neenkqubo zomgangatho we-ISO 9001 kunye nokuthobela imigangatho ye-IEC/GB. Abavelisi abathatha inxaxheba kwiinkqubo zophando zesizwe babonisa ukuba banokuza neengcinga ezintsha. Umzekelo, uXi'an Xikai wenze izixhobo ezilinganiswe nge-plateau phantsi kweNkqubo ye-863 yaseTshayina, evumela ukuba zisebenze kwiimitha ezingama-4,000, apho uxinano lomoya luhla ngama-40%.
- Ukuguquguquka kokwenziwa ngokwezifiso: Iimpahla zekhathalogu zisebenza kakuhle kwiindlela ezininzi ezisetyenziswayo, kodwa xa kukho iimfuno ezikhethekileyo, ezifana nemithwalo ye-harmonic okanye indawo encinci, iinjineli kufuneka zisebenzisane. Senza uyilo oluqhelekileyo ngokutshintsha imo ye-core, ii-turns ratios, kunye ne-terminal setups ukuze zihambelane neemfuno zenkqubo nganye ngaphandle kokuthatha ixesha elide.
- Ukuzibophelela Emva Kokuthengisa: Inkxaso epheleleyo idlula amaxesha esiqinisekiso kwaye ibandakanya iingcebiso zeengcali, uncedo ngokusebenza, kunye nokufikelela kwiindawo ezingasetyenziswanga. Ukuze ufumane amaxesha okuphendula ngokukhawuleza kuzo zonke iindawo zexesha, iziseko zethu zenkonzo ziquka amaqela ezobuchwepheshe athetha iilwimi ezintathu kwaye anokufikelelwa apha serina@xaxd-electric.com, amber@xaxd-electric.com, yaye luna@xaxd-electric.com.
Ezi mpawu zahlula ababoneleli abathembekileyo kwabaqhelekileyo, kwaye zinciphisa iindleko zizonke zobunini ngokunciphisa ixesha lokungasebenzi kwaye zenze ucwangciso lokulungisa lube lula. Ukwakha ubudlelwane nabathengisi ngokusekelwe ekuvulelekeni nakulwazi lobuchwephesha kunika umvuzo kwiminyaka engama-30 yokuphila kweeasethi eziqhelekileyo kumacandelo oncedo kunye namashishini.
Ukufakela nokulungisa iindlela ezilungileyo zokuguqula izinto zangaphakathi
Ukuchaneka kokulinganisa kunye nokhuseleko lwabasebenzi kuchaphazeleka ngokuthe ngqo kukufakelwa. Ngokulandela amanyathelo athile ngexesha lokufaka, iimpazamo eziqhelekileyo zinokuphetshwa, kwaye idatha yokusebenza esemgangathweni inokuqokelelwa ukuze isetyenziswe kwixesha elizayo.
Izikhokelo zokuFakelo zeNyathelo ngeNyathelo
Ngaphambi kokuba uqale ukulungisa indawo, qiniseka ukuba imingxunya yephaneli ilingana nobukhulu obufanelekileyo be-transformer kwaye ushiye indawo eyaneleyo yokuphelisa ucingo kunye nokudluliselwa kobushushu. Faka isixhobo sime nkqo usebenzisa izibiyeli eziza naso, uqiniseke ukuba i-nameplate inokubonwa ngezizathu zokujonga. Qhagamshela ii-conductors eziphambili ngokweentolo ezikwiphakheji. Ukuba ubuyisela umva i-polarity, ubudlelwane besigaba sesiphumo sesibini buya kuphoswa, nto leyo enokubangela ukuba ii-relay zokukhusela zingaphumeleli. Ukuthintela ukuphazamiseka kwe-electromagnetic, i-wiring yesibini isebenzisa ubuncinci i-2.5 mm² yobhedu kwaye ibaleka kwiintambo zombane. Ngaphambi kokuba uvule umbane, jonga ukumelana nobushushu phakathi kwee-windings eziphambili kunye nezesibini kunye nokumelana kwe-winding nganye emhlabeni. Ukufundwa okungaphantsi kwe-100 megohms kuthetha ukuba umswakama ungene kwaye kufuneka ujongwe.
Amaqhinga okuQonda iMpazamo eqhelekileyo kunye nezisombululo
Ukulahleka kwe-insulation kubonakala njengokwehla kancinci kokuxhathisa okanye umsebenzi wokukhupha kancinci ngelixa inkqubo ijongwa kwi-intanethi. Le nkqubo yokwaluphala ikhawuleziswa zizinto ezikwindalo esingqongileyo, ezifana nokufuma okanye ukuvezwa ngamakhemikhali. Ukubeka iinkqubo zokususa ubumanzi kunye nokwenza uphando rhoqo ngemifanekiso yobushushu kunokufumana iindawo ezinengxaki ngaphambi kokuba ziqhekeke. Iingxaki zokuthembeka konxibelelwano zikhokelela kwimisinga yesibini engazinzile. Ukuze ususe amalungu anokumelana okuphezulu abangela ukushukuma komlinganiselo, qinisa izikrufu zesiphelo ngokweenkcukacha zomenzi. Iqela lethu leengcali linceda ngokuxilongwa okukude ngokujonga iirekhodi ze-waveform okanye iiprofayili zobushushu ukuze ufumane ngokukhawuleza izizathu eziphambili.
Iinkqubo zoLondolozo ezicwangcisiweyo zokuQhubela phambili kokusebenza
Ukubeka amaxesha okujonga rhoqo kuqinisekisa ukulingana phakathi kokuthembeka kunye neendleko zomsebenzi wokulungisa. Ukujonga umonakalo owenziwe emzimbeni, ukuqinisekisa ukuba uqhagamshelo luqinile, kunye nokuvavanya ukumelana nobushushu yizinto ekufuneka zenziwe kube kanye ngonyaka. Iingcali zokuhlaziya umgangatho wamandla kufuneka zisetyenziswe ukuqinisekisa ukuba ukuthotyelwa kweklasi yokuchaneka kuyafezekiswa rhoqo emva kweminyaka emihlanu. Ukugcina iirekhodi zenkonzo kubonisa iipateni ezinokwenzeka ukuba zenzeke kwakhona, ukuze iingxaki zilungiswe ngaphambi kokuba zibe nkulu kakhulu ukuba zingaphathwa. Le ndlela yokuzikhusela ihambelana neendlela ezilungileyo zokulawula iiasethi kwiindawo ezibalulekileyo apho ukonakala okungacwangciswanga kunokubiza imali eninzi.
Iingenelo Zokusebenzisa iiTransformers zangoku zangaphakathi kwinkqubo yakho yombane
Ukusetyenziswa kwee-precision current transformers kuphucula ukusebenza kakuhle, ukhuseleko lwenkqubo, kunye nempumelelo yezemali ngeendlela zokwenyani. Ngokudala ixabiso lobomi bonke, ezi nzuzo zenza utyalo-mali lokuqala lube lufanelekile.
Ukuchaneka Okuphezulu Okuvumela Ulawulo Oluphezulu Lwamandla
Ukuchaneka kokulinganisa kunefuthe ngqo kwindlela iindleko zamandla ezisasazwa ngayo kunye nendlela umgangatho wamandla ohlalutywa ngayo kakuhle. Ukuchaneka kweKlasi 0.2 kuqinisekisa ukuba umahluko kwiibhili zamandla ugcinwa uncinci kwaye kunika idatha echanekileyo yokuphucula impendulo yemfuno. Ukulinganisa ngokuchanekileyo kusetyenziswa ziindawo zedatha ukusasaza iindleko zokupholisa ngokulinganayo phakathi kweendawo zabathengi, nto leyo eyenza imali icace ngakumbi. Ukubeka esweni umbane ojijekileyo kunceda iifektri zifumane oomatshini abangasebenzi kakuhle ngokubhekisa izixhobo zokulungisa koomatshini abasebenzisa amandla amaninzi ngeendlela ezingaqhelekanga. I -transformer yangaphakathi ye-24kV igcina imilinganiselo ichanekile nokuba kukho ukuphambuka kwe-harmonic ukuya kuthi ga kwi-10%. Ingasebenza ngee-variable frequency drives kunye nemithombo yamandla ye-switch-mode eqhelekileyo kwimithwalo yanamhlanje yemizi-mveliso.
Uyilo oluNcinci oluphucula indawo yokufaka
Xa kuthelekiswa noyilo lwendabuko lwe-wound-primary, ii-transformer zangaphakathi zithatha indawo encinci kakhulu kwiphaneli. Uyilo oluvaliweyo ngokupheleleyo lugcina iindawo eziphilayo zingangeni endleleni, nto leyo enciphisa umbane ofunekayo ngokwe-NEC Article 110.26. Oku kusindisa indawo kwaye kuluncedo ekulungiseni apho i-switchgear yangoku inokusingatha amanqaku ongezelelweyo okulinganisa ngaphandle kokutshintsha iphaneli. Utshintsho lokuthobela imithetho lunokwenziwa kumagumbi ezixhobo angengomakhulu kakhulu, njengaxa izibhedlele zongeza ukulandelwa kokhathalelo olubalulekileyo okanye xa izakhiwo zoshishino ziphucula ukulinganiselwa kwabasebenzi.
Iingenelo zoqoqosho ngokuncitshiswa kweendleko zomjikelo wobomi
Ixabiso eliphantsi lobunini lenziwa lizinto ezingagqwaliyo, ukufakelwa kwe-epoxy okungadingi kugcinwa, kunye nokumelana okunamandla kwesekethe emfutshane. Iitransformer zethu zinokusingatha i-25kA fault currents imizuzwana emithathu, ngoko ke zinokusingatha ukuphazamiseka kwegridi ngaphandle kokufuna ukutshintshwa. Xa kuthelekiswa neeyunithi ezindala ezizaliswe yioyile, iindleko zomsebenzi eziqhubekayo ziyehla ngama-60% xa kususwa iisampulu zeoyile ezicwangcisiweyo, ukulungiswa kwe-bushing, kunye neenkqubo zokulawula ukufuma. Xa zisasazwa kwiminyaka engaphezu kwama-30, ezi mali zigcinayo ziyarhoxisa naluphi na unyuso lwamaxabiso kwiindlela ezingabizi kakhulu ezingapheli ixesha elide.

isiphelo
Iitransformer zangaphakathi ziyinxalenye ebalulekileyo yeenkqubo zombane zoshishino nezeshishini ezivumela ukulinganisa ngokuchanekileyo, ukudluliselwa ngokukhuselekileyo, kunye nolawulo lwamandla. Ukwazi indlela ezisebenza ngayo, iinkcukacha ezizifunayo, kunye nendlela eziza kusetyenziswa ngayo kunceda iingcali zokuthenga ukuba zikhethe ezona ndlela zibalaseleyo ezilungelelanisa ukusebenza kunye nemida yamaxabiso. Le transformer yangaphakathi ye-24kV ngumzekelo omhle wefilosofi yoyilo lwanamhlanje. Idibanisa i-epoxy resin insulation, ukuguquguquka kwe-multi-ratio, kunye nokuthobela imigangatho yamazwe ngamazwe kwiphakheji encinci efanelekileyo yokufakelwa okunendawo encinci. Xa usebenza nabavelisi abanamava, unokufumana ulwazi lobuchwephesha, iindlela zokwenza ngokwezifiso, kunye nezixhobo zokuxhasa ozidingayo ukuze ugqibezele iprojekthi ngempumelelo, nokuba uhlaziya iziseko zophuhliso ezindala okanye uvula ezintsha. Ukunika ingqalelo esondeleyo kwinqanaba elifunekayo lokuchaneka, imeko-bume, kunye neziqinisekiso zomthengisi kuphumela kwiinkqubo zokulinganisa ezibonelela ngedatha echanekileyo kangangeminyaka emininzi yokusetyenziswa.
FAQ
1. Ngaba ii-transformers zangaphakathi zingasebenza kwiimeko ezingaphandle okanye ezinzima?
Iitransformer zamandla angaphakathi ezisemgangathweni zisebenza kakuhle kwiindawo ezicocekileyo nezilawulwa yimozulu. Iiyure ezimbalwa zokuchayeka kwizinto eziphilayo zithetha ukuba amazinga okhuseleko kufuneka abe phezulu. Kwiifektri ezingaphandle ezifana nezitishi ezigqunyiweyo, senza izivalo ze-IP23 kunye ne-IP30 ezikhusela ukutshiza kunye nothuli. Ukusetyenziswa ngaphandle ngokupheleleyo, kufuneka izindlu ezimelana nemozulu ezidlula oko kufunekayo ngaphakathi.
2. Iiklasi zokuchaneka zikuchaphazela njani ukuthembeka kokulinganisa kwiindawo ezisebenzayo zokufakela?
Iklasi yokuchaneka ikuxelela ipesenti ephezulu yempazamo evumelekileyo kumthamo olinganisiweyo. Iiyunithi zeKlasi 0.2 zihlala zichanekile ukuya kuthi ga kwi-±0.2% ukusuka kwi-5% ukuya kwi-120% yemithwalo, nto leyo eyenza ukuba zilungele ukulinganiswa kwengeniso. Ukusetyenziswa kokhuseleko kunokujongana nokunyamezelana kweKlasi 5P kuba imida yokusebenza yeereyila inika indawo yempazamo yokulinganisa. Ngokukhetha ukuchaneka okungalunganga, unokufumana ukufundwa okungachanekanga kokuba angakanani amandla asetyenziswayo okanye ufumane uhambo olucaphukisayo.
3. Ngowuphi umbandela wewaranti kunye nenkxaso yobugcisa ekufuneka abathengi bayilindele?
Abavelisi abanegama elihle banikezela ngeziqinisekiso zokugubungela iziphene kunye neengxaki zezinto zokwakha ubuncinane iinyanga ezingama-24. Kwiindlela ezibalulekileyo zokusetyenziswa, ukhetho olongezelelweyo lokugubungela lufikelela kwiinyanga ezingama-60. Inkxaso yobugcisa kufuneka ibandakanye ubunjineli bezicelo ngaphambi kokuthengiswa, uncedo ngokuseta, kunye nokulungisa iimpazamo ngokukhawuleza kulo lonke ixesha lomkhiqizo. Iqela lethu linikezela ngenkxaso yamazwe ngamazwe ngokusebenzisa i-serina@xaxd-electric.com, amber@xaxd-electric.com, kunye ne-luna@xaxd-electric.com.
Sebenzisana noXi'an Xikai kwiZisombululo zePremium Indoor Current Transformer Solutions
UXi'an Xikai uyila ii-transformer zangoku ezisetyenziswa kwiinkqubo zoshishino, zoshishino, kunye nezoncedo kulo lonke elaseMntla Melika. I-transformer yethu yangaphakathi ye-24kV yenziwe nge-epoxy resin, ichanekile kwiKlasi 0.2, kwaye iyahambelana ne-IEC 61869, ngoko ke ingasetyenziswa kuyo yonke into ukusuka kumaziko edatha ukuya kwimizi-mveliso. Abahlanganisi beenkqubo kunye nabaqhubi bezakhiwo banokufumana uncedo kuthi ngobunjineli bezicelo, ulungelelwaniso lwesilinganiselo esenziwe ngokwezifiso, kunye namaxwebhu obuchwephesha aneenkcukacha. Ungathumela i-imeyile kwiingcali zethu zobunjineli ku-serina@xaxd-electric.com , amber@xaxd-electric.com , okanye luna@xaxd-electric.com ukuze uthethe ngeemfuno zakho zeprojekthi, nokuba ufuna iimpahla zekhathalogu eziqhelekileyo okanye ukukwazi ukwenza ii-transformer zangaphakathi ezizodwa . Sineenkqubo ezisemgangathweni ze-ISO 9001 kunye nenkonzo yabathengi enobuhlobo emva kokuthengiswa.

Ucaphulo
1. IKhomishini yeHlabathi ye-Electrotechnical, "IiTransformers zeZixhobo - Icandelo lesi-2: Iimfuno ezongezelelweyo zeeTransformers zangoku," IEC 61869-2, 2012.
2. Imigangatho yeSizwe yeRiphabliki yabantu baseTshayina, "IiTransformers zeZixhobo - Icandelo lesi-2: Iimfuno ezongezelelweyo zeeTransformers zangoku," GB 20840.2-2014.
3. I-Institute of Electrical and Electronics Engineers, "Isikhokelo se-IEEE sokusetyenziswa kweeTransformers zangoku ezisetyenziselwa iinjongo zokukhusela ukudluliselwa," IEEE C37.110-2007.
4. Blackburn, JL kunye noDomin, TJ, "Ukudluliselwa Kokhuseleko: Imigaqo kunye neZicelo," Uhlelo Lwesine, iCRC Press, 2014.
5. Winders, JJ, "Ii-Power Transformers: Imigaqo kunye neZicelo," uMarcel Dekker, 2002.
6. I-Electric Power Research Institute, "Ukuchaneka kweTransformer yangoku kwizicelo zokulinganisa ingeniso," Ingxelo yoBugcisa ye-EPRI 1020017, 2010.