ProductPic

I-Capacitor yeFilimu ye-10KV

1.Ubuninzi be-60Hz.
2. Ukuphambuka komthamo -5% ~ + 10%.
3.Ubuninzi bamandla angoku angama-2.5×In.
Ixhotyiswe ngee-discharge resistors 4. Idityaniswe nezixhobo ezizimeleyo zokukhusela i-over-voltage.
5. Ukusebenza okuziphilisayo okuphezulu kunye nobomi benkonzo eyongeziweyo.
6. Uyilo oluphantsi lokulahleka, uhlobo olomileyo olunolwakhiwo olungenamanzi.
7. Ixhotyiswe ngee-resistors zokukhupha umoya.
  • Ukuhanjiswa ngokukhawuleza
  • quality Assurance
  • 24/7 INkonzo yabaThengi

Intshayelelo Product

I-10KV Film Capacitor - Izisombululo zamandla ezisebenza ngokuphezulu

Intshayelelo Product

Xa ufuna usasazo lwamandla oluthembekileyo kwi-10,000 volts, i-10KV Film Capacitor yethu inika ukusebenza okugqwesileyo kwiimfuno zakho ezifuna kakhulu. Ezi capacitors ziphambili zenzelwe ngokukodwa iinkqubo ze-medium-voltage apho ukuthembeka kungenakuchaphazeleka. Zakhiwe ngetekhnoloji yefilimu ye-polypropylene ephezulu, zibonelela ngokuphathwa kwe-voltage ephezulu kunye nokuqina okuhlala ixesha elide okuxhomekeka kuko imisebenzi yakho.

Ii-capacitor zethu zefilimu zinezithinteli zokukhupha ezidityanisiweyo zokhuseleko oluphuculweyo. Ziza nezixhobo ezizimeleyo zokukhusela i-over-voltage ezakhelwe ngaphakathi. Ufumana ukusebenza okuphezulu kokuziphilisa okwandisa ubomi benkonzo kakhulu. Uyilo lohlobo olomileyo lususa ngokupheleleyo iingxaki zokuvuza. Okubaluleke kakhulu, ufumana ilahleko ephantsi kakhulu ephucula ukusebenza kakuhle kwenkqubo.

Izikhankanyi Technical

ye parameter Inkcazo
Voltage ikaliwe 10kV
Ubuninzi 50 / 60Hz
Ukutenxa kwiCapacitance -5% ukuya +10%
Ubuninzi yangoku 2.5 × Ngaphakathi
Umba wokuLahla (tan δ) <0.0005 kwi-1kHz
Ukwambathisa Resistance > 30,000 MΩ
ngamaqondo yokusebenza -40 ° C ukuya kwi-85 ° C
Izinto zeDielectric Ifilimu yePolypropylene (PP).
Ukucaphulwa I-epoxy resin egcina ilangatye
Ukhuseleko Rating Ul94 V-0
Ukuphathwa kwePulse Ukuya kuthi ga kwi-1000V/µs

Iimpawu eziphambili kunye nezinto eziluncedo

ITekhnoloji yokuZiphilisa

Inkqubo yakho ihlala isebenza nokuba emva kokunyuka kwamandla ombane. Xa kwenzeka i-overvoltage, itekhnoloji yethu yefilimu eyenziwe ngesinyithi iyazahlula ngokuzenzekelayo iimpazamo kwaye ibuyisele ukusebenza kwayo.

I-Ultra-Low Loss Factor

Ugcina iindleko zamandla ngokuvelisa ubushushu obuncinci ngexesha lokusebenza. Ulwakhiwo lwe-polypropylene oluphambili lubonelela ngokusebenza kakuhle okuphambili kushishino.

Ulwakhiwo olomeleleyo

Yakhelwe ukumelana neemeko zoshishino ezinzima. I-epoxy encapsulation ethintela ilangatye ikhusela kumswakama kwaye ithintela ukungqubana okuyingozi.

Amandla okuPhula aphezulu

Phatha utshintsho olukhawulezayo lwe-voltage ngokuzithemba. Ukwenziwa kwesinyithi okunzima kuyamelana nokutshintsha kwezinto ezitshintshayo eziya konakalisa ii-capacitor zesiqhelo.

Izicelo eziSebenzayo

IiNkqubo zokuHanjiswa kwaMandla

Uza kufumana ii-capacitor zethu ze-high-voltage ezibalulekileyo kwiibhanki ze-switchgear ze-medium-voltage kunye ne-power factor correction. Zinceda ukugcina uzinzo lwegridi kwaye zinciphise izohlwayo zamandla ezisabelayo.

Izixhobo zeShishini

Ifanelekile kwiimoto eziqhubayo, izixhobo zokuwelda, kunye noomatshini abanzima apho ukusebenza okuthembekileyo kwe-10KV Film Capacitor kubalulekile ekusebenzeni rhoqo.

Izixhobo zoNyango nezeNzululwazi

Themba ii-capacitors zethu kwiimashini ze-X-ray, ii-CT scanners, kunye nezixhobo zelebhu apho ukuchaneka nokhuseleko kubaluleke kakhulu.

IiNkqubo zaMandla aVuselelwayo

Xhasa iiturbine zomoya kunye nee-solar inverters ezinembuyekezo yamandla asebenzayo eqinileyo kunye nolawulo lwe-voltage.

Ingaba isebenza kanjani

I- 10KV Film Capacitor isebenza ngemigaqo ye-dielectric ephucukileyo. Iileya ezininzi zefilimu ye-polypropylene zenza umqobo we-voltage oqinileyo. Xa uxinzelelo lombane luvela, i-metalized coating isasaza i-voltage ngokulinganayo kwi-dielectric.

Indlela yokuziphilisa ngokwayo isebenza ngexesha leziganeko ze-overvoltage. Ukwenziwa kwesinyithi kwindawo yempazamo kuyaphela ngoko nangoko. Oku kuyayihlukanisa indawo eyonakeleyo ngelixa kugcinwa umsebenzi we-capacitor. Inkqubo yakho iyaqhubeka nokusebenza ngaphandle kokuphazamiseka.

UkuGqwesa kwemveliso

Iziko lethu lemveliso lilandela imigangatho engqongqo yomgangatho. I-capacitor nganye ivavanywa ngokupheleleyo ngaphambi kokuba ithunyelwe. Sisebenzisa kuphela iifilimu ze-polypropylene ezikumgangatho ophezulu ezivela kubaboneleli abaqinisekisiweyo.

Ulawulo lomgangatho luquka uvavanyo lwe-high-voltage, ukujikeleza kobushushu, kunye nokuqinisekiswa kobude bobomi. Inkqubo yethu yolawulo lomgangatho we-ISO9001 iqinisekisa ukusebenza rhoqo. Ulawulo lokusingqongileyo ngesatifikethi se-ISO14001 lukhusela iplanethi yethu.

I -10KV Film Capacitor nganye ihlangabezana nemigangatho yamazwe ngamazwe kuquka i-IEC 60871 kunye ne-IEC 61071. Oku kuthobela kuqinisekisa imida yokhuseleko ngokuchasene ne-overvoltages yesikhashana.

Kutheni Sikhetha

Amava angqiniweyo

UXi'an Xikai unamava eminyaka emininzi kwizixhobo ze-voltage ephakathi nephantsi. Iimveliso zethu zinceda abathengi kuzo zonke iiprojekthi zokuvelisa umbane, ezokuzenzekela kwemizi-mveliso, kunye neziseko zophuhliso.

Uluhlu lweeMveliso eziBanzi

Sinikezela ngezisombululo ezipheleleyo zokusasazwa kwamandla. Ukusuka kwiswitshi ye-voltage ephezulu ukuya kwi-transformers, indlela yethu edibeneyo yenza lula inkqubo yakho yokuthenga.

Uxhaso lobuchwepheshe

Iqela lethu lobunjineli libonelela ngeengcebiso zobungcali kulo lonke ixesha leprojekthi yakho. Sinceda ekuphuculeni ukhetho lwe-capacitor ukuze luhambelane neemfuno zakho zesicelo esithile.

Intsebenziswano ethembekileyo

Khetha umenzi ozinikele kubudlelwane bexesha elide. Sinikezela ngenkxaso yobugcisa eqhubekayo kunye nokufumaneka kwezixhobo ezingasetyenziswayo kwiminyaka ezayo.

FAQ

Q: Yintoni eyenza ii-capacitors zefilimu zibe ngcono kuneentlobo ze-ceramic kwizicelo ze-10kV?

A: Ii-capacitor zefilimu zisusa ingxolo ye-piezoelectric kunye neengxaki zokuqhekeka eziqhelekileyo kwiintlobo ze-ceramic. Zikwabonelela ngokuphatha kakuhle i-pulse kunye nokukwazi ukuziphilisa.

Q: Ezi capacitors zihlala ixesha elingakanani?

A: Ngokufakelwa kakuhle kunye neemeko zokusebenza, ii-capacitors zethu zefilimu zibonelela ngeminyaka engaphezu kwama-20 yobomi benkonzo ethembekileyo.

Q: Ngaba ezi capacitors zingakwazi ukujongana nokufakelwa kwangaphandle?

A: Ewe, i-epoxy encapsulation ethintela ilangatye ikhusela kumswakama, amaqondo obushushu aphezulu, kunye nokuvezwa yi-UV kwiindawo zangaphandle.

Q: Zeziphi iindlela zokuthintela ukukhupha ezikhoyo?

A: Sinikezela ngee-resistors ezidityanisiweyo zokukhupha umbane ezilinganiswe ukunciphisa umbane ngokukhuselekileyo kungakapheli umzuzu omnye emva kokuqhawulwa kombane, sihlangabezana nemigangatho yokhuseleko.

Q: Ngaba ninikezela ngexabiso le-capacitance elenziwe ngokwezifiso?

A: Ngokuqinisekileyo. Senza uqwalaselo olulungiselelwe wena ukuze luhlangabezane neemfuno zakho ze-voltage, capacitance, kunye nokufakelwa.

Qhagamshelana nathi

Ngaba ukulungele ukuphucula ukuthembeka kwenkqubo yakho yamandla? Iingcali zethu zobugcisa zilapha ukukunceda ukhethe isisombululo esifanelekileyo se -10KV Film Capacitor kwisicelo sakho.

Nxibelelana neqela lethu namhlanje ukuze ufumane iinkcukacha ezineenkcukacha, uqwalaselo olwenziwe ngokwezifiso, okanye ingcebiso yobugcisa. Sizimisele ukukunika izixhobo zokusasaza umbane ezikumgangatho ophezulu ezixhaswa yinkxaso yeengcali.

I-imeyile: serina@xaxd-electric.com

Masikuncede ufezekise ukusebenza kakuhle kwenkqubo yamandla ngetekhnoloji yethu ye-capacitor yefilimu ephucukileyo. Impumelelo yakho yeyona nto iphambili kuthi.

thumela