ProductPic

I-Capacitor yokuziphilisa

1. I-Voltage elinganisiweyo(Ue): 250v ~ 525v, ukuya kuthi ga kwi-2000v.
2.Ubuninzi:50/60Hz.
3. Uyilo oluncinci, oluxhotyiswe ngebholthi yokumisa umhlaba.
4. Izinto zokufaka iimbiza: i-PU resin (i-resin ethambileyo).
5.Ukufakwa lula kunye neentambo.
6.Ubungakanani obuncinci, Ubunzima obukhaphukhaphu.
7. Ukuziphilisa, Akukho kulungiswa.
  • Ukuhanjiswa ngokukhawuleza
  • quality Assurance
  • 24/7 INkonzo yabaThengi

Intshayelelo Product

I-Capacitor yokuziphilisa

Intshayelelo Product

Ngaba ufuna izisombululo zomgangatho wamandla ezinokuthenjwa kwinkqubo yakho yombane? I-Self-healing Capacitor yethu inikezela ngokusebenza okugqwesileyo kunye nokuthembeka kwizicelo zoshishino kunye nezorhwebo. Ezi capacitors zenziwe yiXi'an Xidian Medium and Low Voltage Electrical Co., Ltd, zisebenzisa itekhnoloji yefilimu ye-polypropylene ephucukileyo ene-metalized metallized enezakhono zokuziphilisa ezakhelwe ngaphakathi. Xa ukhetha ii-capacitors zethu, utyala imali kwizixhobo ezenzelwe ukuphucula amandla, ukunciphisa ilahleko ezisabelayo, kunye nokuphucula umgangatho wamandla ngokubanzi kwiinethiwekhi zakho zokusasaza ii-voltage eziphantsi. I-Self-healing Capacitor nganye ine-operation engenakulungiswa kunye neendlela zokukhusela ukhuseleko ezipheleleyo.

Ezi capacitors zenzelwe ngokukodwa iinkqubo ze-AC ezisebenzisa amandla rhoqo. Zibonelela ngezakhono zoqhagamshelo lwe-shunt eziphucula ukusebenza kweziseko zakho zombane. Uyilo lwethu oluncinci luqinisekisa ukuhlanganiswa okulula kwiinkqubo ezikhoyo ngelixa zibonelela ngeempawu zombane eziphezulu.

Izikhankanyi Technical

ye parameter Inkcazo
Ulinganiso lombane (Ue) 250V, 400V, 460V, 480V, 525V, 660V (ukuya kuthi ga kwi-2000V)
Ubuninzi 50 / 60 HZ
Inqanaba lokugquma 3kV
Ilahleko yeDielectric <0.0010 (20°C, 50Hz)
ngamaqondo yokusebenza -20 ° C ukuya kwi-50 ° C
Ngaphezulu Ukuya kuthi ga kwi-2000m (iimodeli eziphakamileyo ziyafumaneka ukuya kuthi ga kwi-4000m)
Ukucaphulwa I-PU Resin (i-Soft Resin) / i-Thermosetting Resin
Izinto zeZindlu Iphepha leNtsimbi eligalelweyo eliyi-1mm
Ixesha lokukhupha I-voltage yehla ngaphantsi kwe-75V kwimizuzu emi-3 emva kokucima umbane
neMigangatho GB/T 12747.1&2-2004, IEC60831-1&2

Iimpawu eziphambili kunye nezinto eziluncedo

Itekhnoloji yokuziphilisa ePhakamileyo

Ii-capacitor zethu zineempawu zokuziphilisa ngokuzenzekelayo. Xa kwenzeka ukonakala okuncinci kwe-dielectric, ifilimu eyenziwe ngesinyithi iyajika ngoko nangoko ijikeleze indawo yempazamo, ihlukanise indawo eyonakeleyo ngaphandle kokuchaphazela ukusebenza kwayo iyonke.

Ukhuseleko olomeleziweyo loKhuseleko

Into nganye ye-capacitor ibandakanya izixhobo zokukhusela ezakhelwe ngaphakathi ezijonga imeko yobushushu obugqithisileyo, umbane ogqithisileyo, kunye noxinzelelo olugqithisileyo. Le teknoloji ikhuselwe yilungelo lomenzi (iNombolo yePatent 200810150609.1) iqinisekisa ukuba inkqubo yakho ihlala ikhuselekile.

Icwecwe kunye noYilo olulula

Ulwakhiwo olugcina indawo lunciphisa umngcipheko wokufakelwa. Uza kufumana ukufakwa kunye nokufakelwa kwentambo kulula kunye neebholithi zokubeka umhlaba ezibonelelweyo.

Ukuchithwa kobushushu obugqwesileyo

Izikhewu zokuzahlula phakathi kwezinto zangaphakathi zikhuthaza ukudluliselwa kobushushu ngendlela efanelekileyo. Indlu yentsimbi yenza kube lula ukulawula ubushushu ngendlela ephezulu, yandisa ixesha lokusebenza.

UkuSebenza kwaMahala koLondolozo

Nje ukuba ifakiwe, iSelf-healing Capacitor yakho ayifuni kulungiswa rhoqo. I-resistor eqhagamshelwe ngokusisigxina iqinisekisa ukunciphisa i-voltage ekhuselekileyo emva kokuqhawulwa.

Ukusebenza kwelahleko ephantsi

Ifilimu ye-polypropylene eyenziwe ngesinyithi esebenza kakhulu inciphisa ilahleko ye-dielectric. Uqhagamshelo lwangaphakathi lwebronze lunciphisa uxinano lwangoku kunye nokumelana noqhagamshelwano, nto leyo ephucula ukusebenza kakuhle kwamandla.

Ukomelela kwendalo

Ukucubungula i-vacuum kunye ne-thermosetting resin encapsulation zahlula ngokupheleleyo izinto zangaphakathi kumswakama wangaphandle kunye nezinto ezingcolisayo.

Izicelo eziSebenzayo

Ishishini lakho lingazuza kwii-capacitors zethu kumacandelo amaninzi:

  • Imveliso yoShishino: Phucula amandla kwiindawo zokuvelisa ngemithwalo enzima yeemoto
  • Izakhiwo zorhwebo: Ukuphucula ukusebenza kakuhle kwamandla kwiindawo zeeofisi nakwiindawo zokuthenga
  • IiNethiwekhi zokuSasaza amandla: Yonyusa umgangatho wamandla egridi kwaye unciphise ilahleko zothumelo
  • IiNkqubo zaMandla aVuselelwayo: Xhasa ukuhlanganiswa kwelanga nomoya kunye nembuyekezo yamandla asebenzayo eqinileyo
  • IiProjekthi zeziseko zophuhliso: Izikhululo zikaloliwe, izikhululo zeenqwelo-moya, kunye neendawo zothutho ezifuna umbane ozinzileyo
  • Metallurgy kunye nePetrochemical: Ukujongana neemeko ezinzima kwiindawo zokucubungula
  • Ukwakhiwa kweeDolophuIinkqubo zombane zesixeko ezikrelekrele kunye nophuhliso lweziseko zophuhliso zanamhlanje

Ingaba isebenza kanjani

Indlela yokuziphilisa isebenza ngetekhnoloji yefilimu ephucukileyo eyenziwe ngesinyithi. Xa uxinzelelo olugqithisileyo olukwindawo ethile luvela kumaleko we-dielectric, ulwelo lwesinyithi olucekethekileyo luyanyibilika ngoko nangoko. Oku kudala indawo yokukhusela ejikeleze indawo yokuphosa, ngokuzenzekelayo ukubuyisela ukusebenza okuqhelekileyo.

Izinto ezicutshungulwa nge-vacuum zivalwe kwi-thermosetting resin, nto leyo eyenza umqobo ongenakungena. Oku kukhusela kwiimeko ezingqongileyo ezidla ngokonakalisa ukusebenza kwe-capacitor.

Xa uqhagamshela i-capacitor kwinkqubo yakho yamandla e-AC, inika imbuyekezo yamandla asebenzayo. Oku kuphucula amandla akho ngokunciphisa imithwalo ye-inductive evela kwiimoto kunye nee-transformers. Isiphumo? Ukunciphisa iindleko zombane kunye nokuphucula uzinzo lwe-voltage kuyo yonke indawo yakho.

Isithinteli sokukhupha esiqhagamshelwe ngokusisigxina siqinisekisa ukuphathwa ngokukhuselekileyo. Kwimizuzu emithathu emva kokuqhawulwa, i-voltage eseleyo yehla ngaphantsi kwe-75V, ikhusela abasebenzi bakho bokulungisa.

UkuGqwesa kwemveliso

Apha eXi'an Xidian Medium and Low Voltage Electrical Co., Ltd, sigcina imigangatho yomgangatho engqongqo. Indawo yethu yokuvelisa isebenzisa iindlela zokuvelisa eziphambili kunye nolawulo olungqongqo lomgangatho kuzo zonke izigaba.

Sisebenzise iinkqubo zolawulo ezibanzi eziquka i-ISO9001 (Ulawulo loMgangatho), i-ISO14001 (Ulawulo lweNdalo), kunye ne-OHSAS18001 (Impilo noKhuseleko emsebenzini). Ezi ziqinisekiso zibonisa ukuzinikela kwethu ekugqweseni.

Iqela lethu lophando nophuhliso lihlala livelisa izinto ezintsha. Njengabathathi-nxaxheba kwiiprojekthi zesizwe, sidibanisa ubuchwepheshe obuphambili kuphuhliso lwemveliso yethu. Oku kuqinisekisa ukuba ufumana izixhobo ezihlangabezana nemigangatho yangoku kunye neemfuno zexesha elizayo.

I-capacitor nganye ivavanywa ngokupheleleyo ngaphambi kokuba iphume kwindawo yethu. Ukususela ekuhlolweni kwezinto eziluhlaza ukuya ekuqinisekisweni kokugqibela kwemveliso, asigcini siqinisekiso somgangatho.

Kutheni Sikhetha

Uluhlu lweeMveliso eziBanzi

Sinikezela ngezisombululo ezipheleleyo zokusasazwa kwamandla ngaphaya kwee-capacitors. Ipotifoliyo yethu ibandakanya iswitchgear, iitransformers, ii-circuit breakers, kunye nezinye kwiindidi ezili-9 kunye neentlobo ezingaphezu kwe-100.

Ingxelo egciniweyo yokuKhangela

Iimveliso zethu zibonelela ngezicelo ezifuna umngeni kuzwelonke. Sifumene udumo njengophawu oludumileyo eTshayina ngenxa yokusebenza rhoqo kunye nokuthembeka.

Ingcali yezobugcisa

Ngamashumi eminyaka yamava kushishino, iqela lethu lobunjineli libonelela ngeengcebiso zobungcali. Sikunceda ukhethe uqwalaselo olufanelekileyo oluhambelana neemfuno zakho ezithile.

Ukukwazi ukwenza ngokwezifiso

Ngaba ufuna ukulinganiswa kwamandla ombane okanye uqwalaselo olukhethekileyo? Sinikezela ngezisombululo ezenzelwe wena ngokwemingeni yakho yesicelo.

Inkxaso ephendulayo

Iqela lethu leenkonzo ezizinikeleyo liqinisekisa ukuba ufumana uncedo ngexesha elifanelekileyo. Ukususela kuphando lokuqala ukuya ekufakweni nangaphaya, silapha ukuxhasa impumelelo yakho.

Ixabiso lokukhuphisana

Uza kufumana amaxabiso ethu ekhuphisana ngelixa ugcina imigangatho yomgangatho engagungqiyo. Sinikezela ngexabiso lokwenyani lotyalo-mali lwakho.

FAQ

Q: Yintoni eyenza ezi capacitors "ziziphilise ngokwazo"?

A: Ifilimu eyenziwe ngesinyithi iyazihlukanisa ngokuzenzekelayo ii-micro-faults ngokufutha i-metal coating ejikeleze iindawo zomonakalo, ibuyisele ukusebenza okuqhelekileyo ngaphandle kokungenelela ngesandla.

Q: Ezi capacitors zihlala ixesha elingakanani?

A: Xa iimeko zokusebenza zisebenza kakuhle, ii-capacitor zethu zibonelela ngeminyaka emininzi yenkonzo engenakugcinwa. Ubomi bokwenyani buxhomekeke kwiimeko zokusingqongileyo kunye neempawu zomthwalo.

Q: Ndingayisebenzisa le capacitors xa ndifakela izinto zangaphandle?

A: Iimodeli zethu ezisemgangathweni zenzelwe ukusetyenziswa ngaphakathi. Nxibelelana nathi ukuze ufumane izisombululo ezikumgangatho wangaphandle ezihambelana nesicelo sakho.

Q: Luluphi ulinganiselo lwe-voltage endifanele ndilukhethe?

A: Khetha umlinganiselo we-voltage ohambelanayo okanye odlula kancinci i-voltage yenkqubo yakho. Iqela lethu linokukunceda umisele iinkcukacha ezifanelekileyo.

Umbuzo: Ngaba unika inkxaso yokufakela?

A: Ewe, sinikezela ngesikhokelo sobuchwephesha sokufakelwa ngokufanelekileyo. Amaxwebhu ethu aquka iinkcukacha ezineenkcukacha kunye needayagram zoqhagamshelo.

Umbuzo: Ngaba iindawo ezitshintshiweyo ziyafumaneka?

A: Nangona ezi capacitors zingenalo ulondolozo, sigcina uluhlu olubanzi lwezixhobo ezingasetyenziswayo ukuze sixhase inkqubo ngokupheleleyo.

Umbuzo: Ungayizalisekisa ngokukhawuleza kangakanani imiyalelo?

A: Amaxesha okufumana izinto ahluka ngokuxhomekeke kubungakanani kunye neenkcukacha. Qhagamshelana nathi ukuze ufumane iinkcukacha zokufumaneka kwangoku kunye neeshedyuli zokuhanjiswa.

Qhagamshelana nathi

Ngaba ukulungele ukuphucula umgangatho wakho wamandla ngezisombululo zethu ze-capacitor eziphambili? Iingcali zethu zobugcisa zimi ecaleni ukuze zixoxe ngeemfuno zakho.

I-imeyile: serina@xaxd-electric.com

Nxibelelana nathi namhlanje ukuze ufumane ulwazi ngemveliso, iinkcukacha zobugcisa, amaxabiso, okanye uphuhliso lwesisombululo esenziwe ngokwezifiso. Siphendula ngokukhawuleza kuyo yonke imibuzo kwaye sijonge phambili ekuxhaseni iimfuno zakho zeziseko zombane.

Masikuncede uphucule inkqubo yakho yokusasazwa kwamandla ngetekhnoloji ye-capacitor ethembekileyo nesebenza kakuhle exhaswa kukugqwesa kwemveliso kunye nenkonzo ephendulayo.

---

I-Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd - Iqabane lakho elithembekileyo lezisombululo ezibanzi zokusasazwa kombane.

thumela