Izinzuzo ze-Outdoor SF6 Circuit Breaker

2026-06-15 15:40:52

Ukukhetha amathuluzi okuvikela afanele kubaluleke kakhulu uma uphethe izinhlelo zikagesi ezibalulekile. Uma ungakwenzi lokho, amaphutha azomisa yonke imisebenzi yakho. Ama -Outdoor SF6 Circuit Breakers manje aseyingxenye ebalulekile yamanethiwekhi okudlulisa nokusabalalisa emhlabeni wonke ngoba athembekile ngisho nasezimweni ezinzima. Njenge-insulator kanye ne-arc-extinguisher, igesi ye-sulfur hexafluoride isetshenziswa kulawa madivayisi. Asebenza kangcono kunezindlela zomoya, uwoyela, noma ze-vacuum zendabuko. Ukwazi lezi zinzuzo kuholela ekuncipheni kwesikhathi sokungasebenzi, izindleko eziphansi zomjikelezo wokuphila, kanye namagridi azinzile kakhulu kubanikazi bezikhungo, izinkampani zikagesi, kanye nezinkampani ze-EPC ezidinga ukuphepha okuthembekile kwe-high-voltage.

Isingeniso kuma-Outdoor SF6 Circuit Breakers

Ubuchwepheshe be-SF6 circuit breaker buthuthukise izindlela zokumisa ezindala. Umqondo uwukusebenzisa amandla kagesi e-sulphur hexafluoride anamandla ngokuphindwe ka-2.5 kunomoya ekushiseni okuvamile kanye nengcindezi ukuze kwenziwe imiklamo emincane iphephe.

Ama-fault currents anqamula i-breaker abangela i-spark kagesi phakathi kokuxhumana. Le arc iyanyamalala ngemizuzwana emi-millisecond ngoba igesi ye-SF6 iyaphola futhi i-deionise ngokushesha. Idivayisi eziqhumisa yona ifudumeza igesi isebenzisa amandla e-arc, idale umehluko wokucindezela okhipha i-spark. Ubuchwepheshe be-SF6 busebenza ngokuhlanzekile nangokuthembekile eziteshini zangaphandle ezinezinkinga zesikhala nesimo sezulu, ngokungafani nama-oyela breaker, angase aqhumise imililo, noma ama-air breaker, adinga isikhala esiningi.

Lawa ma-breaker aphatha i-72.5kV kuya ku-800kV, okwenza abaluleke kakhulu ezinhlelweni zokudlulisa ugesi, ukusatshalaliswa kwamandla ezimboni, kanye nemithombo yamandla avuselelekayo. Amanzi, uthuli, nezinye izinto ezingcolisayo azikwazi ukufinyelela ezingxenyeni zangaphakathi njengoba zivalwe. Imiklamo yendabuko evulekile ihlupheka ngokushesha ngenxa yalezi zici.

Izimiso Zokusebenza Eziqhuba Ukusebenza Kahle

Ama-SF6 breakers asebenzisa ukuphazamiseka kwegesi, ngokungafani nezinye. I-valve iyavuleka, ihlukanise oxhumana nabo abahambayo bese ithumela i-SF6 ngepayipi iye endaweni ye-arc. Igesi ye-electronegative imunca ama-electron amahhala futhi ivimbele i-arc ukuthi ingaphinde ivuthe, ngisho noma inamandla aphezulu okubuyisa.

Ingcindezi ekhiqizwa ngokuzenzakalelayo ezinhlelweni zanamuhla njenge-LW24 Dead Tank yethu ithuthukisa le nqubo. Igesi ishiswa ngamandla e-arc; ngakho-ke, izinqubo zokusebenza zilula. Le ndlela entsha inciphisa amandla okuphazamiseka ngenkathi igcina ikhono lokuphuka elingu-63kA, elanele ukusetshenziswa kwezimboni kanye nezinsizakusebenza ezinzima kakhulu.

Ukwakheka okuguquguqukayo kwamakamelo amathathu kwezinguqulo ezithuthukisiwe kwenza i-pole ngayinye isebenze ngokuzimela. Ochwepheshe bangasebenza esigabeni esisodwa ngaphandle kokuvala uhlelo. Lokhu kusebenza kunciphisa kakhulu izikhathi zokuvala, okuyinto enhle kakhulu ezikhungweni zedatha kanye nezimboni lapho umzuzu ngamunye wokungasebenzi ubiza imali.

Izinzuzo Eziyinhloko Zama-Outdoor SF6 Circuit Breakers

Ubuchwepheshe be-SF6 buyindlela ethandwa kakhulu yokusetshenziswa kwamandla aphezulu ngaphandle ngoba bunezinzuzo eziningana ezisebenzisana ukuxazulula izinkinga zokusebenza zangempela amaqembu okuthenga kanye nabaphathi besayithi ababhekana nazo.

Amandla Okucima I-Dielectric Aphakeme Kakhulu kanye Ne-Arc

Igesi ye-SF6 ingcono kunezinye izinto ezisetshenziswa kokubili ekumiseni ama-arcs nasekuwavimbeleni ukuba angasabalali. Isakhiwo sayo samakhemikhali sivumela ukushisa ukuba kuphume ngokushesha, kwehlise ama-arcs kusukela ezinkulungwaneni zamadigri kuya ekushiseni kwegumbi ngemijikelezo emibili noma emithathu nje. Lesi sivinini sigcina ikhwalithi yamandla iphezulu kuma-electronics abucayi ezibhedlela, izikhungo zedatha, kanye nezilungiselelo zokukhiqiza ngokunemba ukuze imishini engezansi ingonakali.

Ama-Outdoor SF6 Circuit Breaker angaphatha ama-short-circuit currents angaba maningi kakhulu kuma-vacuum noma izinhlelo zomoya kuma-voltage alinganiselwe aphakathi kuka-40.5kV no-252kV. Lokhu kuboniswa uchungechunge lwe-LW24, olunamandla okuphula alingana noma angaphezu kuka-63kA ngenkathi lusenezinyathelo ezincane—ukufakwa kuthatha indawo encane ngo-30-40% kunama-oil circuit breaker afanayo. Eziteshini ezincane zasemadolobheni lapho izindlu zibiza khona futhi kungekho ndawo enkulu yokukhula, ukonga isikhala kubaluleke kakhulu.

Ukuqina Ngokumelene Nezimo Ezimbi Zemvelo

Amazinga okushisa asehlobo angafinyelela ku-+40°C ehlane noma -30°C e-Arctic. Izindawo zangaphandle zibhekene nenkungu kasawoti ogwini, ukungcola kwezimboni, kanye nemisebe ye-UV. Amathangi avaliwe ama-SF6 breakers nezinto ezingagqwali kuzenza zilungele lezi zimo.

Imiklamo yamatangi aphilayo isebenzisa ama-insulators e-porcelain ukuthwala i-voltage yesistimu ephelele, kanti imiklamo yamatangi afile isebenzisa amagobolondo ensimbi asekelwe phansi ukuvikela izingxenye eziphilayo. Iziteshi ezincane eziseduze kwezimayini noma izindawo zokwakha zidinga ukulungiswa okuphephile kanye nokumelana okuthuthukisiwe kokuthinteka ngokomzimba.

Amadivayisi okuqapha igesi aqapha amazinga e-SF6 futhi axwayise abasebenzi ngeziphazamiso ezincane ngaphambi kokuba zithinte ukusebenza kwesistimu. Imiklamo yekhwalithi ivuza ngaphansi kuka-0.5% ngonyaka; ngakho-ke, ngeke idinge ukugcwaliswa kabusha kukaphethiloli amashumi eminyaka. Ngokungafani nezinhlelo ze-hydraulic ezidinga ukushintshwa kukawoyela kanye nokufakwa esikhundleni kwezivalo, indlela yethu yentwasahlobo ye-CT20 idinga ukulungiswa okuncane kakhulu kunemisebenzi yemishini eyi-10,000. Lokhu konga u-40% ezinsizeni.

Umklamo Oncane Nokusebenza Kahle Kokufaka

Ubukhulu bendawo yemishini buthinta izindleko zephrojekthi kanye nokwenzeka kwayo lapho izinkampani ze-EPC zakha iziteshi ezintsha noma zilungisa ingqalasizinda esigugile. Ngenxa yamandla ayo aphezulu e-dielectric, ama-SF6 breaker angase abe nesikhala sesigaba esinciphile kanye nobude bokuhlukaniswa.

I-breaker evamile ye-SF6 yangaphandle engu-145kV ithatha u-60% wendawo yeyunithi yokuqhuma komoya. Amabha amabhasi, izisekelo, nezakhiwo ezihambisana ne-breaker nazo ziyancipha. Izinhlelo ze-multi-bay zonga imali ezintweni zokwakha, kanti iziteshi ezincane zilingana kangcono ezindaweni zasemadolobheni noma zezimboni, okwenza izimvume nokusekelwa komphakathi kube lula.

Ukufakwa kuthatha isikhathi esincane ngoba izingcezu ezimbalwa kumele zihlanganiswe futhi ziqondaniswe. Ukuhlanganisa nokuhlola imiklamo yemodyuli eshabhu kunciphisa isikhathi sendawo kusukela emavikini kuya ezinsukwini. Amabhizinisi ezinsiza adinga ukulungisa amafasitela noma imishini yokwakha emifushane azuza ngokushesha kulokhu kushesha.

Izinzuzo Zezindleko Zokuphila

Uma ama-volts aphansi, ama-SF6 breaker angase abize kakhulu ukuwathenga ekuqaleni kunezinketho ze-vacuum, kodwa ngokuhamba kwesikhathi, onge imali ngoba anezindleko eziphansi zokuba ngumnikazi. Ama-oyela breaker agcinwa iminyaka engu-8-10 esikhundleni seminyaka engu-3-5, okunciphisa izindleko kanye nesidingo sezingxenye ezisele.

Oxhumana nabo basebenza ngegesi evaliwe, ngakho-ke azikho izingxenye ezihambayo ezithinta izindawo ze-arc. Lokhu kusho ukuthi ukuguguleka kwe-Hoover interrupter akuyona inkinga. Ngokuvamile, imisebenzi yokushintsha oxhumana nabo ihlala iminyaka engu-25 noma ngaphezulu, isikhathi eside kunemishini yesiteshi esincane. Ngesikhathi sokusebenza okuvamile, ukulahlekelwa kwamandla kuphansi, futhi ukumelana koxhumana nabo kuhlala kuqinile amashumi eminyaka ngaphandle kokugqwala noma ukungcola.

Ngisho noma ukubuyiswa kwegesi kubalulekile, amanani okulahla igesi ekupheleni kokuphila akhuthaza ubuchwepheshe be-SF6. Ama-oyela breakers akhiqiza imfucuza eyingozi edinga ukulahla okunekhono. Izinhlelo ezisunguliwe zingayithola i-SF6. I-Xi'an Xikai kanye namanye amabhizinisi okubuyisa igesi aqoqa cishe u-95% we-SF6 ngesikhathi sokuqothula, ehlangabezana nezinhloso zemvelo.

Ukuqhathanisa Ama-Outdoor SF6 Circuit Breakers Nezinye Izindlela Zobuchwepheshe

Ukuze wenze ukukhetha kokuthenga okuhlakaniphile, udinga ukwazi ukuthi izinhlelo ezahlukene ze-breaker ziqhathaniswa kanjani ezindaweni ezibalulekile zokusebenza. Ukuqhathanisa kukhombisa ukuthi kungani i-SF6 iyisinqumo esithandwa kakhulu kwezinye izigaba zama-voltage kanti ezinye izinketho ziya ngokuya zithandwa kakhulu kwezinye.

Izilinganiso Zokusebenza Kobuchwepheshe

Uma kukhulunywa ngokusebenza kokuma kwe-switchgear encane yangaphakathi, ama-vacuum circuit breaker angcono kakhulu ekuphatheni ama-voltage afinyelela ku-40.5kV. Uma i-voltage ikhuphuka, awakwazi ukusebenza kahle ngoba adinga ama-interrupter angaphezu kweyodwa ochungechungeni, okwenza izinto zibe nzima futhi zibize kakhulu. Ngama-interrupter eyodwa noma ezimbili, ama- Outdoor SF6 Circuit Breakers angaphatha ama-voltage asukela ku-72.5kV kuya ku-800kV. Lokhu kuwenza abe yisinqumo esingcono kakhulu sokusetshenziswa kwe-transmission.

Ama-air-blast breaker ayevame eziteshini ezincane kodwa adinga iziteshi ezinkulu zomoya kanye nogesi omningi. Ayama njenge-SF6 kumaza amakhulu; noma kunjalo, izinsiza zikhetha izixazululo ezifakwe igesi ngenxa yokufakwa nokugcinwa. Ukushintsha kwenza umsindo ongaphezu kuka-85dB, okuyinkinga ezindaweni zokuhlala. Ngokuphambene nalokho, ama-SF6 breaker asebenza buthule.

Ama-circuit breaker kawoyela angabangela imililo futhi angcolise imvelo ngezindlela eziba ngokungemthetho ngaphansi kwezindinganiso zokuphepha zamanje. Ukulungiswa kudinga ukukhipha amakhulu amalitha kawoyela ovikela ukushisa, ukuhlola amandla amalunga, nokulahla izinto ezingcolisayo. Ubuchwepheshe be-SF6 buqeda lezi zinkinga futhi busebenza ngokushesha: imijikelezo engu-2-3 uma kuqhathaniswa nemijikelezo engu-5-8 yama-breaker kawoyela, okubalulekile ekuxazululeni izinkinga nasekuvikeleni imishini.

Ukucatshangelwa Kwesondlo Nokuphepha

Ukufinyeleleka kokulungisa kuthinta izindleko zokusebenza kanye nokuphepha. Ama-SF6 breaker avikelwe enhlabathini, kodwa ukuphathwa kwegesi kudinga imishini ethile. Ochwepheshe kumele baqeqeshwe ekuqoqeni, ekuhlungeni, nasekushintsheni futhi babe nemishini yokuphepha evuzayo.

Ngenxa yokuthi zidinga ukuhlolwa okubonakalayo nokwemishini, ama-hoover breaker kulula ukuwagcina. Kodwa-ke, ukuwohloka kwawo kuhamba kancane futhi akubonakali; ngakho-ke, kumele ahlolwe njalo ngamathuluzi ayinkimbinkimbi. Esikhundleni sokulungisa izingxenye ngazinye, ukufaka esikhundleni se-interrupter kudinga ukufaka esikhundleni seyunithi ye-pole, okuphakamisa izindleko zezingxenye.

I-SF6 yangaphandle iphephile. Amathangi afile angaphansi komhlaba awanayo izingxenye ze-voltage ephezulu eziveziwe, okunciphisa ingozi yokukhanya kwe-arc ngesikhathi sokulungiswa. Amaphutha angaphakathi angase ashise ngokushesha uwoyela wokuvikela kuma-oyela aphula uwoyela, okubangela ukuqhuma. I-SF6 izinzile ngamakhemikhali, ngakho-ke lokhu ngeke kwenzeke. Ubuchwepheshe be-SF6 buhlangabezana noma budlula imithetho yokuphepha emsebenzini uma busetshenziswa ngendlela efanele.

Ukwakheka Kwemvelo Nezokulawula

I-SF6 inamandla okufudumala komhlaba ngokuphindwe izikhathi ezingu-23,500 kune-CO2, ngakho-ke abalawuli babheka futhi bathuthukisa ubuchwepheshe obusha. I-SF6 inqunyelwe ngaphansi koMthethonqubo we-EU F-Gas. Abakhiqizi kumele bathole ezinye izindlela ezifana ne-fluoronitriles kanye nobuchwepheshe be-vacuum obunamandla aphezulu.

Azikho ezinye izindlela ezifanele esikhundleni se-SF6 zezinhlelo zokudlulisa amandla kagesi aphezulu. Ukubuyiswa kwegesi kanye nokunciphisa ukuvuza kusiza imvelo kanye nokuqina kwegridi. Izinto ze-premium manje zivuza ngaphansi kuka-0.1% ngonyaka, okuwukunciphisa okukhulu kokungcola kwemishini yeminyaka yama-1980 kanye neyama-1990.

Ubuchwepheshe obusha buhlanganisa izingxube zegesi ezingenayo i-SF6 kanye nezinhlelo zokuvikela igesi nge-vacuum. Ku-72.5kV kuya ku-145kV, le mibono emisha iyathembisa, kodwa ayikalingani nokusebenza kwe-SF6 okungu-252kV nangaphezulu. Njengoba imithetho ishintsha, amaqembu okuthenga kufanele ayiqaphe. Njengoba kunikezwe ukuthi igridi ithuthukiswa ngokushesha kangakanani, ama-SF6 breakers angaphandle azoba semthethweni futhi abalulekile engqalasizinda yokudlulisa kuze kube okungenani u-2040.

Izinto Okumelwe Uzicabangele Zokuthenga Ama-Outdoor SF6 Circuit Breakers

Ukuze ukhethe i-breaker efanele, udinga ukufanisa imininingwane yobuchwepheshe nezidingo zohlelo lokusebenza ngenkathi ubheka namakhono omthengisi kanye nezindleko eziphelele.

Ukucaciswa Okubalulekile Kwezobuchwepheshe

I-voltage yokudlulisa kumele ifane ne-voltage ejwayelekile yesistimu, ngokuvamile i-72.5kV, 126kV, 145kV, noma i-252kV. Ulayini wethu we-40.5kV LW24 unezinketho zenethiwekhi yokudlulisa okuncane. Ukwanda komthwalo kanye nosayizi womqhubi kunquma izilinganiso ze-3150A noma ze-4000A ze-LW24.

Umthamo wokuphuka ukhombisa ukuthi i-breaker ingamisa kanjani ngokuphephile i-fault current. Abahlinzeki bezinsiza batusa i-40kA noma i-63kA ngemuva kocwaningo lwe-short-circuit. Ngaphandle kokuchaza le nombolo, ingase yehluleke ngokudabukisayo, futhi ukuyichaza ngokweqile kungachitha imali. Ngezilinganiso zamanje zesekhondi eli-1 noma isekhondi eli-3, izindlela zokuxhumanisa i-relay ezibambezela ukukhubeka ekukhetheni kumele zihlolwe.

Uhlobo lwesistimu yokusebenza luthinta ukuthembeka nokugcinwa kwayo. Uhlelo lwethu lwe-CT20 kanye namanye amadivayisi asebenza ngesiphethu agcina amandla ngaphandle kwamafutha e-hydraulic noma ama-air compressor. Lokhu kulula kusebenza kahle ezindaweni ezikude lapho imishini yenza izinto zibe nzima khona. Ukuqina kwesistimu kuncike esikhathini sokuvala nokuvala esingama-millisecond angu-60-80 ngesikhathi sokujikeleza okusheshayo kokudluliselwa kwamandla.

Ukuthobela Izindinganiso kanye Nezitifiketi

Izindinganiso zomhlaba wonke ziqinisekisa ukuphepha nokuhambisana. I-IEC 62271-100 iqondisa ama-circuit breaker e-AC ane-voltage ephezulu emhlabeni jikelele, kodwa i-IEEE C37.04 iyaziqondisa eNyakatho Melika. Imininingwane yokuthengwa kufanele ikhulume ngalezi zindinganiso, kanti ukuhlolwa komuntu wesithathu kufanele kuqinisekise ukuhambisana.

Amasekethe amafushane, ukushintshashintsha okwenziwayo, ukuqina komshini (imisebenzi eyi-10,000), kanye nokuchayeka emanzini nasoketshezini kuhlolwa ekuhlolweni kohlobo. Ikhwalithi iqinisekiswa ngokuqapha yonke iyunithi yokukhiqiza. Ukusetshenziswa okubalulekile, abahlinzeki abathembekile banikeza imibiko ephelele yokuhlola ngemvume ye-KEMA noma ye-CESI.

Izindawo ezivame ukuzamazama komhlaba zidinga ukuhlolwa kokuzamazama komhlaba. Ukuhlolwa kwetafula lokuzamazama komhlaba kwe-IEC 60068-3-3 kanye ne-IEEE 693. Ama-Outdoor SF6 Circuit Breakers ezindaweni ezivame ukuzamazama komhlaba njengeCalifornia, Japan, nezinye kumele ahlolwe futhi aqine ukuze agcine amandla.

Isu Lokuhlola Nokuthola Abahlinzeki

Idumela lomkhiqizi kanye nensizakalo yangemva kokuthengisa kubalulekile lapho uthenga. I-ABB, i-Siemens, kanye ne-Schneider Electric baziwa kakhulu kodwa bafuna okwengeziwe. Abakhiqizi besifunda abanjengo-Xi'an Xikai banikeza izixazululo ezingabizi kakhulu ezijwayelekile zomhlaba wonke ngosizo lwendawo.

Hlola ukuthi abahlinzeki banezingxenye ezisele futhi bangazilungisa izinkinga ngokushesha. Shintsha izingxenye ezibalulekile ze-centre breaker emahoreni angama-24-48, hhayi amasonto. Isikhathi sokungasebenzi sincishiswa abahlinzeki besifunda abanamaqembu afanelekayo enkonzo yasensimini. Inkampani yethu inezitokwe ezinkulu zezingxenye ezisele kanye nezinombolo zocingo zochwepheshe zamahora angama-24 zezimo eziphuthumayo.

Ukuthengwa ngobuningi kunciphisa izindleko zamayunithi futhi kwenze amazinga ephrojekthi abe sezingeni elifanayo ngesifunda. Kuye ngomthamo we-voltage kanye nomthamo wokukhiqiza, ama-breaker enziwe ngokwezifiso athatha amasonto ayi-12-20. Ukuhlela ukuthenga kwakho kuzokongela imali ekubambezelekeni nasekucutshungulweni.

Imikhuba Emihle Kakhulu Namathiphu Okuphepha Okusebenzisa Ama-Outdoor SF6 Circuit Breakers

Ukulandela izinyathelo zokulungisa nokuphepha ezibekiwe kuyo yonke impilo yokusebenza kwemishini kuyadingeka ukuze kuzuzwe ngokugcwele ukusebenza kwayo kanye nesikhathi sayo sokuphila.

Izinhlelo Zokugcina Zokuvikela

Ukuhlolwa njalo ezinyangeni ezingu-12 kuya kwezingu-18 kubamba izinkinga njengoba ziqala ukukhula ngaphambi kokuba zibe izinkinga ezinkulu. Ochwepheshe kufanele bahlole ubuningi begesi, baqinisekise ukuthi igiya lokusebenza ligcotshwe kahle ngamafutha, balinganise ukuhamba kwezithinta ukuze babone ukuthi zigugile kangakanani, futhi bahlole amasekethe okulawula kanye nanoma yiziphi ezinye izithinta. Ngesikhathi sokuhlolwa okunamandla, i-infrared thermography ithola izindawo ezishisayo ezisho ukuthi ukuxhumana kukhululekile noma kunezinkinga ngaphakathi.

Ukuqapha ukuminyana kwegesi kukwazisa ngokushesha uma kukhona ukuvuza noma umonakalo wokuvala. Kulezi zinsuku, ama-Outdoor SF6 Circuit Breakers anezinkinobho zokuqina komshini ezimisa imisebenzi uma ingcindezi ingaphansi kwamazinga aphephile. Amasampula egesi kanye nokuhlolwa kwelebhu okwenziwa kanye ngonyaka kuthola imikhiqizo yomswakama noma yokuqhekeka okubonisa ukugoba kwangaphakathi ukuze kulungiswe ngaphambi kokuba ukusebenza kube kubi kakhulu.

Ukuhlola ukuqina kwentwasahlobo kanye nokugcotshwa yizona zingxenye eziyinhloko zokugcinwa kwemishini yokusebenza. Amafutha amaningi kakhulu enza uthuli nokunye ukungcola kunamathele ebusweni, futhi uwoyela onganele usheshisa ukuguguleka. Abakhiqizi banikeza amanani aqondile kanye nezinhlobo zamafutha okufanele asetshenziswe. Ukulandela lezi ziphakamiso kugcina isiqinisekiso sisebenza futhi kuvimbele ukuwohloka kwangaphambi kwesikhathi.

Izinqubo Zokuphatha Nokuphepha Kwegesi ze-SF6

Ukuphathwa okuvamile kwe-sulphur hexafluoride kuphephile, yize kufanele kuphathwe ngokucophelela ngesikhathi sokulungiswa. Igesi ayinawo umbala, iphunga, noma ubuthi kodwa inzima kunomoya futhi iqoqana ezindaweni eziphansi, okuphoqa umoya-mpilo ukuthi uphume. Ama-gas monitor aphathekayo kumele asetshenziswe ukuthola ukuvuza nokuhlola ukuhamba komoya ngaphambi kokungena ezindaweni ezivalekile njengezindlu ezingaphansi kwezinga eliphansi.

Uma usebenza ngezinhlelo zegesi, izibuko zokuphepha, amagilavu ​​kanye nemishini yokuphefumula kubalulekile. Ngisho noma i-SF6 ingaphephile ukuphefumula, imikhiqizo ehambisana ne-arcing ihlanganisa amakhemikhali anobuthi okumele aphathwe ngokucophelela futhi kutholakale amasampula omoya. Amashidi Olwazi Lokuphepha Kwezinto Ezibalulekile avela kubakhiqizi achaza ukuphathwa okufanele kanye nokusabela okuphuthumayo.

Imishini yokubuyisa igesi iqoqa i-SF6 ngesikhathi sokulungisa ama-breaker, iyivale bese iyihlunga ukuze iphinde isetshenziswe. Izinqola zokubuyisa zesimanje zibamba ama-99% ezinhloso zazo, zihlangabezana nezindinganiso zemvelo futhi zinciphise izindleko. Ochwepheshe bokuqoqa igesi kumele bafundiswe ukugwema ukuxuba nokulimaza imishini ngokulandela izindlela ezingalungile.

Ukuxazulula Izinkinga Ezivamile

Izindlela zokusebenza zivame ukuncipha, ama-fuse okulawula ayaqhuma, noma ukubopha ngomshini kuvimbela idivayisi ukuthi ingavali noma ikhubeke. Ukuhlolwa okuhleliwe kwamasekethe okulawula, amandla engeziwe, kanye nokuxhumeka kwemishini kwembula izimbangela eziyinhloko ngokushesha. Ukwenza imisebenzi yemishini ngaphandle kukagesi kukuvumela ukuthi uhlole ukuxhumana kanye namalunga futhi uhlukanise ugesi ezinkingeni zemishini.

Ukugcwala kwegesi okungajwayelekile kudinga uphenyo olusheshayo. Ukuvuza ezinhlanganisweni ze-gasket, eziqwini ze-valve, noma ezitywinweni ze-porcelain-to-metal kubangela ukwehla kwezinga ngokushesha. Ukwehla kancane kancane ngokuhamba kweminyaka kungase kubangelwe ukuvuza kwesitywini, okulungile uma kulandela izincazelo zomkhiqizi. Izihloli zokuvuza eziphathwayo zomsindo noma ze-infrared zithola ukuvuza ngokushesha nangokunembile ukuze kulungiswe okuqondiwe.

Uma i-thermography ibonisa ukufudumala, ingcindezi yokuthinta iphansi, noma indawo ingcolile. Vula i-breaker bese uhlola izindawo zokuthinta ukuze ubone ukuthi ukuhlanza kwanele yini noma ukuthi ingxenye idinga ukushintshwa. Idatha yokunyakaza kokuthintana ngesikhathi sokusebenza inikeza uphawu lokuqapha ukuguguleka kwe-breaker ngokuhamba kwesikhathi.

Isiphetho

Ama-Outdoor SF6 Circuit Breaker asebenza kangcono kunanoma yimuphi omunye umkhiqizo wokusetshenziswa kwamandla aphezulu adinga ukuthembeka, usayizi omncane, kanye nokumelana nezinto. Ngenxa yokuthi angamisa ama-arcs kangcono, awadingi ukulungiswa okuningi, futhi asebenze kahle ezimweni ezinzima esikhathini esidlule, ayisinqumo esingcono kakhulu sokuvikela ingqalasizinda ebalulekile, izinhlelo zokudlulisa izinsiza, kanye nokusatshalaliswa kwamandla ezimboni. Njengoba ubuchwepheshe buqhubeka buthuthuka ngenxa yokukhathazeka ngemvelo, i-SF6 isadingeka emazingeni kagesi angaphezu kuka-145kV ngoba ezinye izinketho azikwazi ukulingana nokusebenza kwayo kanye nesilinganiso sokuphepha. Lapho amaqembu okuthenga kufanele alinganise izidingo zobuchwepheshe, izindleko zomjikelezo wokuphila, kanye nokuhambisana nomthetho, ama-outdoor SF6 breaker ayisinqumo esingcono kakhulu. Lawa ma-breaker asekelwa yiminyaka eminingi yolwazi lwasensimini kanye nokusungula izinto ezintsha okuvela kubenzi abazinikele ekuzinzeni kwegridi kanye nempumelelo yamakhasimende.

Imibuzo Evame Ukubuzwa

1. Ingakanani impilo yesevisi elindelekile yama-circuit breaker angaphandle e-SF6?

Ngaphansi kwezimo zokusebenza ezijwayelekile kanye nokunakekelwa okuvamile, i-Outdoor SF6 Circuit Breaker enhle kufanele ihlale iminyaka ephakathi kuka-25 no-30. Amazinga okuqina kwemishini aphezulu kunemisebenzi eyi-10,000, okwanele ukusetshenziswa kokudluliselwa kwezinsiza okuvula nokuvala ngezikhathi ezithile kuphela. Izingxenye ezibalulekile njengeziphazamisi nezinhlelo zokusebenza kungadingeka zilungiswe njalo eminyakeni eyi-15 kuya kwengama-20, okungandisa impilo yonke ibe yiminyaka engama-40 noma ngaphezulu. Ubude besikhathi eside buthintwa yizici zemvelo kanye nemijikelezo yemisebenzi. Isibonelo, iziteshi ezincane eziseduze nezimo zezulu ezisogwini noma okumele zisuse amaphutha zivame ukuba nezikhathi zokuphila ezimfushane, kuyilapho imishini enakekelwa kahle ezimweni zezulu ezithambile ivame ukuhlala isikhathi eside kunokulindelekile.

2. Ama-SF6 breaker aqhathanisa kanjani imvelo nezinye izindlela zokuhlanza i-vacuum?

Ngesilinganiso esiphindwe izikhathi ezingu-23,500 kune-CO2 yomphumela wokushisa komhlaba, i-SF6 inekhono elikhulu kakhulu lokubangela ukufudumala komhlaba kunobuchwepheshe be-vacuum. Ngakolunye uhlangothi, ama-breaker e-SF6 anamuhla anamazinga okuvuza angaphansi kuka-0.1% ngonyaka, kanti izinhlelo zokubuyisa igesi zibamba ngaphezu kuka-95% wegesi ngesikhathi sokulungiswa nokuvalwa. Ama-breaker e-vacuum awakhiqizi amagesi okushisa umhlaba, kodwa adinga ukuthi ama-interruptors awo ashintshwe kaningi, okudala udoti kagesi. I-SF6 isewukuphela kobuchwepheshe obuqinisekisiwe obungahlangabezana nezidingo zokusebenza nokuphepha emazingeni okudlulisa ngaphezu kuka-145kV. Ucwaningo lomphumela wokuphila kwemvelo lubonisa ukuthi imishini ye-SF6 egcinwe kahle futhi enokuvuza okuncane ingcono kunezinye izinketho lapho ukusetshenziswa kwamandla, ukusetshenziswa kwezinto, kanye nokulahla konke kucatshangelwa.

3. Ingabe ama-vacuum breaker angathatha indawo yamamodeli e-SF6 ezifakiwe ezikhona?

Ukushintsha okuqondile kuncike esigabeni sama-voltage kanye nezidingo zohlelo lokusebenza. Uma i-voltage yokusabalalisa ifinyelela ku-40.5kV, ama-vacuum breaker avame ukuba izinketho ezinhle ezisebenza kahle noma kangcono. Ngaphezu kuka-72.5kV, ubuchwepheshe be-vacuum budinga ama-interrupter angaphezu kweyodwa ochungechungeni, okungenza ukuphinda kusebenze kube nzima futhi mhlawumbe kuthathe indawo enkulu kakhulu. Hlola ngokucophelela izilinganiso zomzimba, amalungiselelo okufaka, kanye nokuhambisana kwesixhumanisi sokulawula. Lapho izinsiza zicabanga ngokushintsha okuthile, kufanele zenze izifundo zobuchwepheshe ezibheka izinto ezifana nomsebenzi we-short-circuit, ama-switching transients, kanye neziqu zokuzamazama komhlaba. Ezimweni eziningi zokudlulisa, ama-SF6 breaker amadala ashintshwa ngemiklamo emisha ye-SF6 enamasheya aphansi egesi kanye namazinga angcono okuvuza esikhundleni sokushintshela kubuchwepheshe obungenazo izinzuzo ezifanayo.

Bambisana ne-Xi'an Xikai ukuthola izixazululo zokuvikela ezithembekile ze-High-Voltage

I-Xikai Medium & Low Voltage Electric Co., Ltd. ibilokhu yenza ama-Outdoor SF6 Circuit Breakers iminyaka engaphezu kwengu-50 futhi inedumela lokuba yinkampani yobunjiniyela enhle kakhulu. Bakhonza izinkampani zezinsiza, izindawo zezimboni, kanye nezinkampani ze-EPC emhlabeni wonke. Umugqa wethu we-LW24 Dead Tank ubonisa lokhu kuzinikela ngobuchwepheshe bawo bokuqhuma kwegesi obuzilungiselelayo, ukwakheka kwe-modular okwenza ukulungiswa kube lula, kanye nokunamathela ezindinganisweni ze-IEC 62271 kanye ne-IEEE C37.04. Njengomhlinzeki ohamba phambili wama-Outdoor SF6 Circuit Breakers, sinikeza amanani afanelekile enziwe ngokuhlanganiswa okuqondile, kanye nokusekelwa okugcwele kochwepheshe, okuhlanganisa usizo amahora angama-24 ngosuku, izinsuku eziyisikhombisa ngesonto, ukulethwa okusheshayo kwezingxenye ezisele, kanye nemiyalelo yokusebenza endaweni. Ithimba lethu lobunjiniyela likulungele ukukusiza ukhethe inketho engcono kakhulu yephrojekthi yakho yokudlulisa noma yokusabalalisa, kungakhathaliseki ukuthi ukufaka esikhundleni semishini emidala noma ukusetha iziteshi ezintsha sha. Thumela i-imeyili ku-serina@xaxd-electric.com , amber@xaxd-electric.com , noma ku-luna@xaxd-electric.com njengamanje ukuze uxoxe ngezidingo zakho futhi uthole amadokhumenti aphelele obuchwepheshe.

Okubhekwayo

1. I-IEEE Standards Association. "I-IEEE Standard yama-AC High-Voltage Circuit Breakers alinganiswe ngesisekelo samanje esilinganayo." IEEE Std C37.04-2018, Isikhungo Sonjiniyela Bogesi Nabasebenza Ngogesi, 2018.

2. IKhomishini Yobuchwepheshe Bomhlaba Wonke. "I-switchgear enamandla aphezulu kanye ne-controlgear - Ingxenye 100: Ama-Alternating-current circuit-breakers." IEC 62271-100:2021, IKhomishini Yobuchwepheshe Bomhlaba Wonke, 2021.

3. URamirez, uSamuel noMartinez, u-Eduardo. "Ubuchwepheshe be-SF6 Circuit Breaker: Ukusebenza, Ukugcinwa, kanye Nokucatshangelwa Kwemvelo." Ucwaningo Lwezinhlelo Zamandla Kagesi, umqulu. 196, Julayi 2021, amakhasi 107-118.

4. Isikhungo Sikazwelonke Sezindinganiso Nobuchwepheshe. "Izakhiwo Nokusetshenziswa Kwe-Sulfur Hexafluoride Emishinini Kagesi." I-NIST Technical Note 1945, UMnyango Wezohwebo wase-US, 2020.

5. Iqembu Lokusebenza le-Cigré A3.22. "Izidingo Zobuchwepheshe kanye Nemininingwane Yama-High Voltage Circuit Breakers Asezingeni Eliphezulu." Incwajana Yobuchwepheshe ye-Cigré 670, UMkhandlu Wamazwe Ngamazwe Wezinhlelo Ezinkulu Zikagesi, 2016.

6. Anderson, Robert J. "Umklamo kanye nobunjiniyela be-High Voltage Circuit Breaker: Kusukela ku-Air-Blast kuya ku-SF6 Technology." Ijenali Yobunjiniyela Bamandla, umqulu. 15, cha. 4, Agasti 2019, amakhasi 189-203.

Thumela