Ama-Capacitor Angcono Kakhulu Okuziphilisa Okulungiswa Kwe-Industrial PF

2026-03-23 15:52:31

Ukuthola i -Self-Healing Capacitor efanele yokulungisa amandla ezimboni kudinga ukuqonda kokubili izici zokusebenza kanye nezidingo zokuthembeka. Lawa ma-capacitor athuthukile aletha ukubuyiswa kwamaphutha okuzenzakalelayo ngobuchwepheshe befilimu ye-polypropylene eyenziwe ngensimbi, aqede izinselele zokugcinwa kwendabuko ngenkathi egcina ikhwalithi yamandla eqhubekayo. Ngokungafani nama-capacitor avamile ahluleka kakhulu, izinhlobo zokuziphilisa ngokwazo zihlukanisa ngokuzenzakalelayo ukuwohloka kwe-dielectric, okuqinisekisa ukusebenza okuqhubekayo ezindaweni ezibalulekile zezimboni. Leli khono libonakala libalulekile ezindaweni zokukhiqiza, izikhungo zedatha, kanye nezindawo zezentengiselwano lapho isikhathi sokungasebenzi siholela ekulahlekelweni okukhulu kwemali engenayo kanye nokuphazamiseka kokusebenza.

i-self-healing capacitor i-self-healing capacitor

Kungani Ama-Capacitor Aziphilisayo Eguqula Ukuphathwa Kwamandla Ezimboni?

Ukunciphisa Izingozi Zokulungisa Ngobuchwepheshe Bokuziphilisa

Kunesidingo esikhulu sezindawo zezimboni sokwenza ngcono ukusetshenziswa kwazo kwamandla ngenkathi zilondoloza ukuthembeka kwazo kokusebenza. Amabhange e-capacitor endabuko angabangela izinkinga zokulungisa lapho amayunithi ehluleka ngokuzumayo, okudinga ukushintshwa okuphuthumayo ukuze kugwenywe izinhlawulo zezinto. Ukuze kunqotshwe lezi zithiyo, ubuchwepheshe bokuziphilisa buhlanganisa ama-electrode e-membrane ensimbi aphumayo azungeze izindawo zamaphutha. Lokhu kuphumela ekudalweni kwezindawo zemvelo zokuhlukaniswa ezingadingi ukungenelela okuvela emithonjeni yangaphandle.

Ukusingatha Ukucindezeleka Kwe-Harmonic Emishinini Yesimanje

Ama-variable frequency drive, imishini yokulawula izinombolo zekhompyutha (CNC), kanye nemigqa yokukhiqiza yamarobhothi evame ukubonakala ezindaweni zokukhiqiza yimithombo yokuphambuka kwe-harmonic. Ama-capacitor avamile abhekana nokucindezeleka ngenxa yalokhu kuphambuka, okuholela ekuhlulekeni kwasekuqaleni kanye nesikhathi esibizayo sokungasebenzi. Ngaphezu kokukwazi ukubekezelela lezi zingcindezi zikagesi, izinhlobo zokuziphilisa nazo ziyakwazi ukukhokhela ngokuzenzakalelayo ukuwohloka okuqhubekayo ngokuhamba kwesikhathi.

Ukusebenza Okuthembekile Ezindaweni Zezimboni Ezikude

Le ndlela ivelele njengewusizo kakhulu ezindaweni zezimboni ezitholakala ezindaweni ezikude futhi zinokufinyelela okulinganiselwe kwabasebenzi bokulungisa. Amabhizinisi ezimayini, izindawo ezisogwini lolwandle, kanye nezitshalo zezimboni ezitholakala ezindaweni ezikude konke kuzozuza kakhulu ngenxa yokuncipha kwezidingo zesevisi kanye nokwethenjelwa kohlelo okuthuthukisiwe.

Izindlela Zokukhetha Zokulungiswa Kwezinto Ezinamandla Ezimbonini

Izidingo Zokulinganisa I-Voltage Nezamanje

Ukuhlolwa kwezici eziningi zokusebenza ezibalulekile kuyadingeka ukuze kukhethwe i-capacitor yokuziphilisa efanele. Lesi sisekelo siqinisekisa ukuhlanganiswa okuphumelelayo ngaphandle kwesidingo sokuthuthukiswa kwengqalasizinda ebizayo ngokuqinisekisa ukuthi isilinganiso se-voltage siyahambisana nezinhlelo esezivele zikhona. Kubalulekile ukuthi amakhono okuphatha amanje adlule imithwalo ephezulu ebikezelwe, okuhlanganisa nezimo zokukhuphuka ezenzeka ngesikhathi sokuqala kwezimoto.

Ukubekezelelana Okuvumelanayo Kwemithwalo Engeyona Eqondile

Ukubekezelelana kwe-Harmonic kumelela esinye isici esibalulekile, ikakhulukazi ezindaweni ezinemithwalo ebalulekile engalingani. Izindawo zezimboni zanamuhla zivame ukukhiqiza amaza ahambisanayo phakathi kuka-150Hz no-2500Hz, okudinga ama-capacitor aklanyelwe ngqo lezi zimo zokusebenza. Ubuchwepheshe be-Self-Healing Capacitor buqinisekisa ukusebenza okuthembekile kokushisa ekufakweni kwangaphandle noma ezinqubweni zezimboni ezishisa kakhulu.

Ukuhambisana Nezokuphepha kanye Namazinga Omkhakha

Ukuze kuqinisekiswe ukuhambisana nezindinganiso zikagesi zesifunda kanye nezidingo zomshuwalense, izitifiketi zokuphepha zibaluleke kakhulu. Izicelo zokulungiswa kwamandla zilawulwa yizindinganiso ezisungulwe yi-IEC 60831, kodwa eminye imikhakha, njengezimboni zezempilo kanye ne-petrochemical, ingadinga izitifiketi ezengeziwe ngaphambi kokusetshenziswa.

Ukuqina Ngaphansi Kwezimo Zemvelo Ezinzima

Izici zokumelana nemvelo zifaka phakathi ukubekezelela umswakama, ukumelana nokudlidliza, kanye nokuhambisana kwamakhemikhali. Izakhiwo zezimboni zivame ukuba nezimo zokusebenza eziyinselele ama-capacitor ajwayelekile angenakukwazi ukuzibekezelela isikhathi eside.

Izixazululo Eziphezulu Ze-Self-Healing Capacitor Zezicelo Zezimboni

I-Xi'an Xidian MKP Series Self-Healing Capacitor

Uchungechunge lwe-MKP luzinikele ekuthuthukisweni kobuchwepheshe befilimu ye-polymer yensimbi esezingeni eliphezulu eklanyelwe ngokukhethekile ukusetshenziswa ekulungisweni kwezimboni kwezicelo zamandla. Amaphethini e-gradient alloy afakiwe kulawa mayunithi anegalelo ekwandeni kokusebenza kahle kokuziphilisa ngenkathi eqinisekisa ukuthi ukuzinza kwe-capacitance kuhlala kukuhle kuyo yonke impilo yawo yokusebenza. Phakathi kwezici zobuchwepheshe ezibaluleke kakhulu yizilinganiso ze-voltage ezisukela ku-230V kuya ku-690V, ezihlinzeka ngokuhambisana nezinhlelo ezahlukahlukene zokusatshalaliswa kwezimboni. Kunezinhlobonhlobo zamanani e-capacitance, asukela ku-5μF ku-100μF, okuvumela ukuguquguquka ukuze kuhlangatshezwane nezidingo ezahlukene zokulungisa. Umklamo unama-electrode enziwe nge-aluminium-zinc alloy, angenzi nje kuphela ukuthi i-conductivity ithembeke kodwa futhi enza kube nokwenzeka ukuthi izinhlelo zokuhlanza amaphutha zisebenze kahle.

Ukuvikelwa emvelweni kuhlangabezana nezimiso ze-IP54, okwenza kufaneleke iningi lezinhlelo zezimboni zangaphakathi. Ukuze kuhlangatshezwane nezimo zezulu ezahlukahlukene, izinga lokushisa efektri lisukela ku--25 degrees Celsius kuya ku-+70 degrees Celsius. Ukuvalelwa okwenziwe nge-epoxy resin akuvumeli umswakama ukuthi ungene ngenkathi kunikeza ukumelana nokuvezwa ngamakhemikhali, okuyinto evamile ezindaweni zezimboni. Ukubekezelelana kwe-Harmonic kufinyelela ku-150% wemvamisa eyisisekelo, okwenza la ma-capacitor afanelekele izikhungo ezine-harmonic distortion ebalulekile. Impilo yesevisi elindelekile idlula amahora ayi-100,000 ngaphansi kwezimo zokusebenza ezijwayelekile, kunciphisa imvamisa yokufaka esikhundleni kanye nezindleko zokulungisa. Izici zokuphepha zifaka phakathi ukwakhiwa okuvimbela ilangabi okuhlangabezana nezidingo ze-NFPA 70 kanye nezindlela zokuvikela ukucindezela ngokweqile ezivimbela ukwehluleka okukhulu. Amandla okuziphilisa ahlukanisa ngokuzenzakalelayo amaphutha ngaphakathi kwamasekhondi amancane, alondoloze ukusebenza kwesistimu ngenkathi evimbela ukwehluleka kwe-cascade.

I-Capacitor Yesihlungi Sohlobo Oluwomile Olusebenza Kakhulu

Njengoba zenzelwe ngqo izindawo zezimboni ezinzima, lezi zingxenye zohlobo olomile zisusa izinkinga zokugcinwa okuhlobene namafutha ngenkathi ziletha ukusebenza kokuhlunga kwe-harmonic okuphezulu. Uhlelo lwe-dielectric oluthuthukisiwe luhlanganisa ifilimu ye-polypropylene nezithasiselo ezikhethekile ezithuthukisa ukuzinza kokushisa kanye nokusebenza kahle kokuziphilisa. Kungenzeka ukukhonza izinhlelo zokusebenza ze-voltage ephakathi ezindaweni ezinkulu zezimboni ngenxa yamakhono e-voltage afinyelela ku-1000V. Kusukela ku-10 degrees Fahrenheit kuya ku-200μF, kunezinketho eziningi ze-capacitance ezitholakalayo, okuvumela ukulungiswa okunembile kwamandla phezu kwezimo eziningi zomthwalo. Ukuqina kokusebenza kwesikhathi eside kugcinwa ngenxa yokwakheka kwefilimu ehlukanisiwe, okunciphisa inani lokulahlekelwa kwamandla okwenzeka ngesikhathi sezinqubo zokuphulukisa.

Ukuphathwa kokushisa kuhlanganisa izici ezikhethekile zokushabalalisa ukushisa ezigcina amazinga okushisa afanele okusebenza ngisho nangaphansi komthwalo ophezulu we-harmonic. I- Self-Healing Capacitor igcina i-coefficient yokushisa ezinzile kulo lonke uhla lokusebenza, iqinisekisa ukusebenza okulinganayo kungakhathaliseki izimo zendawo. Umklamo womshini umelana nokudlidliza okufika ku-5G, ofanele izinhlelo zokusebenza eziseduze nemishini esindayo noma imishini yeselula. Ukuguquguquka kokufaka kwamukela kokubili ukufakwa kwamaphaneli kanye nokucushwa kwangaphandle, okuvumelana nezidingo zesikhungo ezahlukahlukene. Izinzwa zokushisa ezakhelwe ngaphakathi noma izindawo zokulinganisa amandla ziyizibonelo zamakhono okuqapha athuthukile. Lezi zici zenza kube nokwenzeka ukusebenzisa amasu okulungisa okubikezela. Ukuhlanganiswa kokuqapha okude kunikeza ukwesekwa kwezinhlelo zamanje zokwenza izinto ngokuzenzakalela kwezimboni, okuletha idatha yokusebenza yesikhathi sangempela evumela ukuphathwa kwesikhungo ukuthi kuthuthukiswe ngempumelelo.

Iyunithi Yokulungisa Amandla Ezimboni Encane

Lezi zakhiwo ze-Self-Healing Capacitor ezine-den high-den, ezithuthukisa ukusebenza nge-cubic meter ngayinye, ziwusizo ezinhlelweni zezimboni ezilinganiselwe endaweni. Ngomklamo ohlangene, kungenzeka ukufeza ukwehla kwevolumu ngamaphesenti angamashumi amane uma kuqhathaniswa namayunithi avamile ngenkathi kusagcinwa izici ezifanayo zokusebenza kukagesi. Ukwenziwa ngcono kobuningi bamandla kusebenzisa amasu athuthukisiwe okusonga amafilimu kanye nokwakheka okukhethekile kwe-dielectric. Izilinganiso ze-voltage zivumela izinhlelo ezijwayelekile zezimboni kusukela ku-380V kuya ku-800V, okuhlanganisa izidingo eziningi zesikhungo. Ubuningi be-Capacitance bufinyelela imininingwane ehamba phambili embonini ngokusebenzisa amaphethini e-electrode amasha kanye nobukhulu be-dielectric obuhle.

Ukuzivumelanisa nezimo kokufakwa kuhlanganisa izinketho ezahlukene zokufaka kanye nezakhiwo zetheminali ngokulandelana. Ukufakwa kwesitimela se-DIN okujwayelekile kwenza izinhlelo zokusebenza zokulungisa zibe lula ukuzisebenzisa, kanti izinhlelo zama-bracket ezenziwe ngokwezifiso zingase zisekele izakhiwo zesikhungo ezihlukile. Ngaphezu kokuxhumeka kwebha yamabhasi namadivayisi ezikulufo, izinhlelo zokuxhuma okusheshayo nazo ziyatholakala njengezindlela zokuxhuma. Indlela yokuziphilisa ifaka ukuphathwa kwamandla okuhlanza okuthuthukisiwe okunciphisa ukulahlekelwa kwamandla ngesikhathi semicimbi yamaphutha. Idatha yezibalo ikhombisa ukuwohloka kwamandla okungaphansi kuka-2% phakathi nezikhathi zesevisi ezijwayelekile zeminyaka eyi-10, kugcinwa ukulungiswa kwamandla okuqhubekayo kuyo yonke impilo yokusebenza kweyunithi. Amaphesenti ayikhulu okuhlolwa kwefektri, kufaka phakathi ukujikeleza komthwalo kanye nokuhlolwa kokucindezeleka kokushisa, kufakiwe ekuqinisekisweni kwekhwalithi. Ukuze kuqinisekiswe ukusebenza okuthembekile kusukela ngesikhathi sokufakwa kokuqala kuze kube yisikhathi senkonzo yokuphela kokuphila, yonke iyunithi ihlolwa ngokushisa okuhlala amahora angama-72 emazingeni okushisa aphezulu.

Izici Zemakethe Yesifunda kanye Nesimo Sokulawula

INingizimu-mpumalanga ye-Asia: Izinselele Zomswakama kanye Nemithethonqubo Yokusebenza Kahle

Uma sibheka amazinga aphezulu omswakama kanye neziphepho zikagesi ezivame ukwenzeka eNingizimu-mpumalanga ye-Asia, lesi sifunda sibeka izithiyo ezihlukile zokulungiswa kwezinto zikagesi zezimboni. Kulezi zimo, ubuchwepheshe bokuziphilisa bunikeza izinzuzo ezinkulu ngokuphulukisa ngokuzenzakalelayo kusuka ezenzakalweni zesikhashana ze-overvoltage, okuyizinhlobo zezenzakalo ezivame ukubangela umonakalo kuma-capacitor endabuko ngokubangela umonakalo. Ngenxa yokusetshenziswa kwezindinganiso zezinto zamandla zempahla yezimboni neyezentengiselwano emazweni anjengeSingapore neMalaysia, imithetho yendawo igxila kakhulu ekusebenzeni kahle kwamandla.

I-Asia Ephakathi: Ukuthembeka Ezimweni Ezinzima Zase-Continental

Izimakethe zase-Asia Ephakathi zigxile kakhulu emikhakheni yezimayini kanye neyamakhemikhali kaphethiloli, okuyizinkampani lapho ukuthembeka kwemishini kunethonya eliqondile emnothweni wokukhiqiza. Isimo sezulu esinzima sezwekazi, esibonakala ngokushintsha okukhulu kwezinga lokushisa, senza amandla okuziphilisa adingeke kakhulu ukuze kulondolozwe ukusebenza kohlelo okulinganayo. Ngokwenza imithethonqubo yabo kagesi ibe sesikhathini futhi ihambisane nezindinganiso zomhlaba wonke, womabili la mazwe avule ithuba lokuthuthukiswa kobuchwepheshe obusha be-capacitor.

IMpumalanga Ephakathi: Izindawo Ezibucayi Nokukhula Kwezimboni

Izikhungo zezimboni zaseMpumalanga Ephakathi zisebenza ngaphansi kwezimo zokushisa okukhulu kanye nokuchayeka othulini, okubeka inselele ekwakhiweni kwe-capacitor yendabuko. Amayunithi okuziphilisa anezinhlelo eziqinile zokufaka ama-capsule abonisa ukusebenza okuphezulu kulezi zindawo. Ukugcizelela kwesifunda ekuhlukaniseni izimboni kuqhuba isidingo sezixazululo zekhwalithi yamandla ezithembekile ezisekela ukwanda kokukhiqiza.

I-Afrika: Ukungazinzi Kwegridi kanye Nezidingo Ezihlukahlukene Zezimboni

Izimakethe zase-Afrika zinezidingo ezahlukahlukene kusukela emisebenzini yezimayini ezifundeni eziseningizimu kuya ezindaweni zokukhiqiza emazweni asenyakatho. Ukungazinzi kwegridi kagesi okuvamile emazweni amaningi ase-Afrika kwenza ikhono le-Self-Healing Capacitor libe yigugu kakhulu ekugcineni umkhiqizo wezimboni naphezu kwezinselele zokuhlinzekwa kukagesi.

Izincomo Zokuthenga Nokucatshangelwa Kokusetshenziswa

Ukuhlolwa Okuphelele Kwesistimu Ngaphambi Kokukhetha

Isinyathelo sokuqala sokwamukelwa ngempumelelo kwama-capacitor aziphilisayo ukwenza uphenyo olunzulu ngohlelo lukagesi. Ngesikhathi sokuhlolwa kwekhwalithi yamandla ochwepheshe, amazinga akhona e-harmonic, izici zomthwalo, kanye nezinto ezithinta ukuvimba uhlelo ezithinta ukukhetha kwama-capacitor ziyahlonzwa. Ukuze kufezwe ukusebenza kahle okuphezulu, ucwaningo lwethu luqinisekisa ukuthi ubukhulu kanye nokucushwa kulungile.

Ukulinganisa Izindleko Ziphelele Zobunikazi

Uma ubeka isabelomali, kubalulekile ukucabangela zonke izindleko ezihambisana nobunikazi kunokuba kucatshangelwe intengo yokuqala yokuthenga. Izindleko zokuphila konke zobuchwepheshe bokuzilungisa zivame ukushibhile kunezobunye ubuchwepheshe ngoba budinga ukulungiswa okuncane futhi buhlala isikhathi eside. Cabanga ngezindleko zesikhathi sokungasebenzi ezagwenywa lapho kubalwa imbuyiselo ekutshalweni kwezimali.

Ukuhlela Ukufakwa Okuhlelekile

Ukuhlela ukufakwa kudinga ukuhlanganiswa nezinhlelo zokukhiqiza ukuze kuncishiswe ukuphazamiseka kokusebenza. Izikhungo eziningi zisebenzisa ukuthuthukiswa kwe-capacitor ngesikhathi sokulungiswa kwamafasitela noma ukunwetshwa kwezikhungo okuhleliwe. Imikhuba efanele yokufaka iqinisekisa ukusebenza kahle kanye nobude besikhathi.

Ukuhlela Ukugcinwa Nokuqapha Okubikezelayo

Ukuhlolwa okuvamile kanye nokuqapha ukusebenza kufanele kufakwe ezinhlelweni zokulungisa. Ngisho noma ama-capacitor aziphilisayo edinga ukulungiswa okuncane kuneziyunithi zendabuko, kusabalulekile ukwenza ukuhlolwa okuvamile ukuqinisekisa ukuthi ayaqhubeka nokusebenza kahle kakhulu. Ukusetshenziswa kokulinganisa amandla kanye nokwephuka kwezinto ezisetshenziswayo ezindleleni zokulungisa ezibikezelayo kuvumela ukuhlonza amayunithi asondela ekupheleni kokuphila kwawo ngisho nangaphambi kokuba kwenzeke ukuphuka.

Ukukhetha Umhlinzeki Ofanele Wokusekela Kwesikhathi Eside

Izindlela zokukhetha abahlinzeki kufanele zigcizelele amakhono okusekela ubuchwepheshe, ukutholakala kwezinsizakalo zasendaweni, kanye nobuchwepheshe bohlelo lokusebenza. Khetha abakhiqizi abanerekhodi eliqinisekisiwe ezinhlelweni zokusebenza zezimboni kanye nokumbozwa kwewaranti okuphelele.

Isiphetho

Ama-capacitor aziphilisayo amelela ushintsho olujwayelekile ekulungisweni kwamandla ezimboni, okuhlanganisa ukubuyiselwa kwamaphutha okuzenzakalelayo nokuthembeka okuthuthukisiwe kanye nezidingo zokunakekelwa ezincishisiwe. Ubuchwepheshe bubhekana nezinselele ezibalulekile ezibhekene nezikhungo zezimboni zesimanje, kusukela ekuphathweni kokuhlanekezelwa kwe-harmonic kuya ekuthuthukisweni kokusebenza kwesikhathi sokusebenza. Izici zemakethe zesifunda kuzo zonke izimakethe eziqondiwe zikhetha ubuchwepheshe be-capacitor obuthuthukisiwe obumelana nezimo zemvelo eziyinselele ngenkathi bugcina ukusebenza okulinganayo. Ukutshalwa kwezimali kubuchwepheshe bokuziphilisa kuletha izinzuzo zokusebenza zesikhathi eside ngokunciphisa izindleko zokulungisa, ukuthembeka kohlelo okuthuthukisiwe, kanye nokusebenza kahle kwamandla okuthuthukisiwe. Ukukhetha nokusetshenziswa okufanele kuqinisekisa ukusebenza okuhle ngenkathi kusekelwa ukuzenzekela okubanzi kwezikhungo kanye nezinhlelo zokulungisa ezibikezelayo.

Imibuzo Evame Ukubuzwa

1. Ubuchwepheshe bokuziphilisa busebenza kanjani ngempela uma kwenzeka izinkinga zikagesi?

Uma kwenzeka ukuwohloka kwe-dielectric ngaphakathi kwe-capacitor, i-arc kagesi ikhiqiza ukushisa okukhulu kwendawo. Lokhu kushisa kuhwamukisa i-electrode encane yensimbi ezungeze indawo yephutha ngaphakathi kwamasekhondi amancane. Insimbi ehwamukile idala igebe lokuvikela elihlukanisa isici kwenye i-capacitor, okuvumela ukuqhubeka kokusebenza ngokulahlekelwa okuncane kwe-capacitance.

2. Yiziphi izidingo zokulungisa ezisebenza kuma-capacitor aziphilisayo?

Amayunithi okuziphilisa adinga ukulungiswa okuncane kakhulu uma kuqhathaniswa nama-capacitor avamile. Imikhuba enconywayo ifaka phakathi ukuhlolwa okubonakalayo kwaminyaka yonke, ukulinganiswa kwamandla okusebenza njalo, kanye nokuqapha ukushisa. Amayunithi amaningi asebenza ngaphandle kokunakekelwa iminyaka eyi-10+ ngaphansi kwezimo ezijwayelekile.

3. Ingabe ama-capacitor aziphilisayo angakwazi ukusingatha izimo ezinzima ze-overvoltage?

Amandla okuziphilisa asebenza kahle ezenzakalweni ezimaphakathi zokusebenzisa amandla kagesi angaphezulu avamile ezindaweni zezimboni. Kodwa-ke, amandla kagesi angaphezulu abangelwa ukushaya kombani noma amaphutha amakhulu egridi angadlula umkhawulo wokuziphilisa, okungase kubangele umonakalo ohlala njalo. Ukuvikelwa kokuqhuma okufanele kusabalulekile ekuvikelweni okuphelele kwesistimu.

Bambisana ne-Xi'an Xidian ukuthola izixazululo ze-Premium Self-Healing Capacitor Solutions

I-Xidian ihlinzeka ngobuchwepheshe be-capacitor yokuziphilisa obuhamba phambili embonini obusekelwa amakhono amakhulu e-R&D kanye nobuchwepheshe bokukhiqiza obuqinisekisiwe. Iphothifoliyo yethu ephelele yomkhiqizo ibhekana nezidingo ezahlukene zokulungiswa kwamandla ezimboni kulo lonke elaseNingizimu-mpumalanga ye-Asia, e-Asia Ephakathi, eMpumalanga Ephakathi, nase-Afrika. Njengoba sinezinhlobo ezingaphezu kwe-100 zomkhiqizo kanye namakhono okwenza ngokwezifiso, sinikeza izixazululo ezenzelwe wena izidingo zakho ezithile zohlelo lokusebenza. Xhumana nethimba lethu lobuchwepheshe ku-serina@xaxd-electric.com , amber@xaxd-electric.com , noma luna@xaxd-electric.com ukuze uxoxe ngezidingo zakho zokulungiswa kwamandla nomhlinzeki we-Self-Healing Capacitor othembekile ozinikele empumelelweni yakho yokusebenza.

Okubhekwayo

1. I-IEEE Standards Association. "Indinganiso ye-IEEE yama-Metallized Polypropylene Film Capacitors ezicelo ze-AC Motor." IEEE Std 1036-2010, Isikhungo Sonjiniyela Bakagesi Nabasebenza Nge-elekthronikhi, 2011.

2. USarjeant, uWalter J., nabanye. "Izingxenye Ezinamandla Zokusebenza Kwe-Elektroniki Yamandla." Izinqubo ze-IEEE, vol. 89, cha. 6, 2001, amakhasi 846-855.

3. IKhomishini Yobuchwepheshe Bogesi Yomhlaba Wonke. "Ama-Capacitor Kagesi Kagesi - Ingxenye 1: Izidingo Ezijwayelekile." I-IEC 61071-1:2017, IKhomishini Yobuchwepheshe Bogesi Yomhlaba Wonke, 2017.

4. Makdessi, Mazen, et al. "Ama-Metallized Film Capacitors Umthetho Wokuguga Osekelwe Ekuwohlokeni Komthamo." Microelectronics Reliability, vol. 54, cha. 9-10, 2014, amakhasi 1823-1827.

5. Tortai, Jean-Herve, nabanye. "Ukuzelapha Kwamafilimu E-Polypropylene Ensimbi Asetshenziswa Ezinhlelweni Ze-Elektroniki Zamandla." I-IEEE Transactions on Dielectrics and Electrical Insulation, vol. 17, cha. 4, 2010, amakhasi 1123-1131.

6. URabuffi, uMaurizio, noGiovanni Picci. "Isimo Esikhona Namathemba Esikhathi Esizayo Ama-Metallized Polypropylene Energy Storage Capacitors." I-IEEE Transactions on Plasma Science, vol. 30, cha. 5, 2002, amakhasi 1939-1942.

Thumela