I-Epoxy Resin Indoor Voltage Transformer: Izinzuzo kanye Nomklamo
2026-08-04 11:19:20
I -transformer yamandla kagesi yangaphakathi esebenzisa i-epoxy resin encapsulation imelela intuthuko ebalulekile ekulinganisweni kukagesi kanye nobuchwepheshe bokuvikela. Lawa madivayisi kagesi afakwe ngokuphelele aguqula amazinga aphezulu kagesi abe amanani alinganisekayo, aphephile okulinganisa kanye namasekethe okuvikela. Ngokungafani namayunithi avamile acwiliswe uwoyela, amamodeli e-epoxy resin asusa izingozi zokuvuza ngenkathi enikeza amandla aphezulu e-dielectric, okwenza abaluleke kakhulu eziteshini zanamuhla, ezakhiweni zezimboni, nasezindaweni zezentengiselwano lapho ukuphepha, ukunemba, kanye nokusebenza kahle kwesikhala kubaluleke kakhulu.

Ukuqonda Ama-Epoxy Resin Indoor Voltage Transformers
Ama-transformer kagesi angaphakathi afakwe ku-epoxy resin angamathuluzi kagesi ayinkimbinkimbi ashintsha ama-voltage aphezulu abe ama-voltage ajwayelekile angasetshenziswa ngokulinganisa kanye nemishini yokuphepha. I-epoxy resin compound inezakhiwo zokuvikela ezingcono kunezinto eziningi, okwenza isithiyo esinamandla ekuqhekekeni kukagesi ngenkathi ihlala ilingana nosayizi kuzo zonke izinhlobo zokushisa.
Izimiso Zokusebenza Eziyinhloko
Uma ukugoqa okuyinhloko kuxhunywe ohlelweni olune-voltage ephezulu, kubangela ukuthi kube khona i-voltage elinganayo ekugoqeni kwesibili. Lena yindlela la ma-transformer asebenza ngayo. Njengengxenye yenqubo yokufaka i-epoxy resin, i-core kanye ne-winding unit ziyaphonswa nge-vacuum. Lokhu kususa noma yiziphi izindawo zomoya ngaphakathi ezingabangela ukukhishwa okuyingxenye noma ukulimala kwe-corona. Le ndlela yokwenza izinto iqinisekisa ukuthi ukusebenza kokufaka ugesi kuhlala kufana phakathi nokuphila kwe-transformer.
Izinhlobo Zokwakha kanye Nezicelo
Ama-core ensimbi ye-silicon aqondiswe kokusanhlamvu asetshenziswa emiklamo yesimanje ukunciphisa ukulahlekelwa yi-hysteresis nokukhulisa ukusebenza kahle kwe-magnetic flux. Ukuze kusetshenziswe okudinga ukunemba okukhulu ngaphansi kwezimo ezahlukahlukene zomthwalo, izinhlobo ze-core ezi-laminated zinikeza ukusebenza okuhle kakhulu. Abakhiqizi abanjengo-Xi'an Xikai bathengisa ama-transformer e-voltage angaphakathi angu-35kV anama-coil esibili anezinhlungu ezimbili agcina ama-circuit metering (isigaba sokunemba esingu-0.2/0.5) kanye nama-circuit okuvikela (isigaba se-3P/5P) ahlukene ngogesi. Lokhu kumisa ukuphazamiseka futhi kuqinisekisa ukuthi izilinganiso zinembile.
Ukucaciswa Kwezobuchwepheshe Okubalulekile
Uma ochwepheshe bokuthenga bebheka izixazululo ze-transformer ezingaba khona, kufanele banake izici ezimbalwa ezibalulekile. Ukusethwa kwesistimu yokusabalalisa ejwayelekile kungasebenza ngezilinganiso ze-voltage yokufaka ezingama-35kV kanye nezilinganiso ze-voltage yokuphuma ezingama-10kV. Ukuhambisana kwemvamisa kwama-50/60Hz kuyenza isebenziseke emhlabeni wonke, futhi ama-current primary alinganisiwe angama-600A kanye nama-800A ahlangabezana nezidingo zemithwalo ehlukahlukene. Ukuhlangabezana nezidingo ze-IEC 61869-1, IEC 61869-2, kanye ne-GB 20840.2-2014 kuqinisekisa ukuphepha nokusebenzisana ezimakethe zomhlaba wonke.
Izinzuzo Ezinkulu Zama-Epoxy Resin Indoor Voltage Transformers
Ukuthola ubuchwepheshe obufanele bokuguqula amandla kagesi angaphakathi kunomthelela oqondile ekutheni imisebenzi ithembeke kangakanani, iphephile kangakanani, nokuthi ibiza malini ngokuhamba kwesikhathi. Amamodeli e-epoxy resin anezinzuzo ezilinganiswayo ezisiza abaphathi bezikhungo, izinkampani zezinsiza, kanye nezinkampani zobunjiniyela ngezinkinga ezibalulekile.
Ukuphepha Okuthuthukisiwe Nokuvikelwa Kwemvelo
Ukuvikela i-resin ye-epoxy kuphephile kakhulu emlilweni kunezinketho ezigcwele uwoyela ngoba akushisi. Izakhiwo ezinemishini ebucayi noma ezisezindaweni ezincane zithola okuningi kulesi sici sokuphepha esakhelwe ngaphakathi. Ukuntuleka kokuvikela uketshezi kususa ingozi yokungcolisa imvelo, okwenza kube lula ukulandela imithetho eqinile yezemvelo eyenziwayo. Ama-transformer e-resin ye-epoxy angaphatha amaza okujikeleza okufushane afinyelela ku-40kA umzuzwana owodwa. Lokhu kubanika isivikelo esinamandla ngesikhathi sezimo zamaphutha ngaphandle kokuthinta amandla esakhiwo.
Ukusebenza Okuphakeme Kagesi
Uma amandla e-dielectric ephezulu, imiklamo ingenziwa ibe mincane ngaphandle kokulahlekelwa yimingcele yokushisa. Uma izinga lokukhishwa okungaphelele lingaphansi kuka-10pC, ukushisa akuphuki kancane, ngakho-ke kuhlala isikhathi esingaphezu kweminyaka engama-30 ngaphansi kwezimo zokusebenza ezijwayelekile. Ukuqina kokushisa kwe-epoxy resin kusho ukuthi iqhubeka isebenza ngokufanayo emazingeni okushisa asukela ku--40°C kuya ku-+70°C. Lokhu kusho ukuthi ingasetshenziswa ezindaweni ezinesimo sezulu esibi, njengezintaba noma amahlane. Ngenxa yokuthi lawa mayunithi angasebenza emazingeni okushisa ahlukahlukene, angasetshenziswa ngamathuluzi aphezulu kaXi'an Xikai angasebenza afinyelela kumamitha angu-4,000.
Izinzuzo Zezindleko Zokusebenza
Ngobuchwepheshe be-epoxy resin, izidingo zokulungisa zincishisiwe kakhulu. Ngokungafani nama-transformer agcwele uwoyela adinga ukuhlolwa kwe-dielectric yawo kanye nokushintsha uketshezi njalo, amayunithi e-epoxy awadingi ukunakekelwa ngesikhathi sokusebenza kwawo. Lokhu kunciphisa ukulungiswa okuvamile kusho isikhathi esincane sokungasebenzi kanye nezindleko zabasebenzi eziphansi. Ukuthuthuka komnotho wamandla, okwenziwe kwaba nokwenzeka ngezinto eziyinhloko ezilahlekelwa kancane kanye nokulungiswa okuhle kokugoqa, kuholela ezindleleni zokusebenza eziphansi ngemva kwamashumi eminyaka okusetshenziswa okuqhubekayo. Izidingo zokunakekelwa okuphansi kanye nokusebenza kahle okuphezulu kwenza izindleko eziphelele zobunikazi zikhange kakhulu, okwenza izimali zokutshalwa kwezimali zokuqala eziphezulu zifanele.
Ukusebenza Kwesikhala Nokuguquguquka Kokufaka
Ubukhulu obuncane, obungaba ngu-400mm x 300mm x 200mm kumamodeli angu-35kV, kwenza kube lula ukuwafaka ezindaweni lapho isikhala silinganiselwe khona se-switchgear. Imiklamo efakwa odongeni isusa isidingo samakamelo ahlukene ejeneretha, okwehlisa izindleko zokwakha indawo. Idizayini elula yenza kube lula ukuhamba ngesikhathi sokufakwa futhi yehlisa umthwalo okudingeka ubekwe esakhiweni. Ukucushwa kwezisekelo zekhebula zokuxhumeka okuyinhloko kwenza ukusetha kube lula futhi kumise amasekethe amafushane angalindelekile angalimaza ubuqotho besistimu.
Zonke lezi zinzuzo zihlangabezana ngqo nezidingo zokusebenza zezimakethe zethu esiziqondisayo. Lapho izimboni zingalinganisa ugesi ngokunembile, zingagcina imishini yazo isebenza isikhathi eside. Ukulandelela ugesi ngendlela enembile kugcina imishini ebalulekile yamakhompyutha iphephile ezikhungweni zedatha. Izibhedlela ziqinisekisa ukuthi izinhlelo zezokwelapha ezibalulekile zihlala zinamandla amahle. Ngokuhlanganisa idatha enembile ye-voltage yesikhathi sangempela namathuluzi okulandelela edijithali, izinkampani zezinsiza zenza igridi izinze kakhudlwana.
Izimiso Zokuklama Nezingxenye Eziyinhloko
Ama-transformer e-voltage angaphakathi e-epoxy resin ayizingxenye zobunjiniyela eziyinkimbinkimbi ezivela eminyakeni yokufunda isayensi yezinto zokwakha, inkolelo-mbono kagesi, kanye nezindlela zokukhiqiza. Ukwazi lezi zimiso zokuklama kusiza amaqembu athengayo ukuqhathanisa izinketho ezahlukene nokukhetha ukusethwa okungcono kakhulu.
Ubuchwepheshe Bokufaka I-Core kanye ne-Winding
Ama-lamination ensimbi ye-silicon eqondiswe kokusanhlamvu enkabeni ye-transformer agcina ukulahlekelwa kwamanje kwe-eddy kuncane futhi athuthukise ukugeleza kwe-magnetic flux. Ama-windings ayinhloko nawesibili akhiwe ngabaqhubi bethusi abahlanzekile kakhulu, futhi ukunemba kokuguqulwa kuncike ekujikeni okuqondile. Ngendlela yokukhipha i-vacuum, i-epoxy resin ewuketshezi ingezwa ekushiseni okulawulwayo kanye nengcindezi, kuqinisekisa ukuthi ihamba yonke indawo kuzo zonke izingxenye eziyinhloko kanye nezendlalelo zamanxeba. Lokhu kususa izikhala zomoya ebezingenza izindawo ezibuthakathaka zibe lula ukuqala ukukhishwa okuyingxenye.
Amasu okuphatha okushisayo
I-Epoxy glue iyi-conductor enhle yokushisa uma iqhathaniswa nomoya, okusho ukuthi yenza kube lula ukuthi ukushisa kusuke ngaphakathi kuye ngaphandle. Uma isetshenziswa ezindaweni ezinzima zezimboni, umklamo ovalwe ngokuphelele ugcina uthuli nomswakama ngaphandle, okunganciphisa ukusebenza. Ubuqotho bomshini we-epoxy matrix buqinisekiswa ukuhlolwa kokujikeleza kokushisa okubonisa ukuthi ingamelana nemijikelezo ephindaphindwayo yokwanda nokuncipha okubangelwa izinguquko emthwalweni kanye nokushisa okuzungezile.
Izici Zokuthobela Izindinganiso Nokuphepha
Ukulandela i-IEC 61869-1 kanye ne-IEC 61869-2 kuqinisekisa ukuthi izinhlelo zokudlulisa ukuvikelwa kwamanye amazwe kanye namathuluzi okulinganisa kungasebenza ndawonye. Ngesikhathi samaphutha ohlelweni, ama-fuse amakhulu akhelwe ngaphakathi anesilinganiso se-XRNP1-10/0.5A avikela ama-windings e-transformer ekulimaleni ama-overcurrent. Lezi zici zokuphepha ezakhelwe ngaphakathi zisusa isidingo sehadiwe eyengeziwe yokuhlanganisa, okwenza ukufakwa kube lula futhi kuthathe indawo encane kuphaneli. Imvamisa yamandla imelana nokuhlolwa kwe-voltage ku-70kV umzuzu owodwa ihlola ikhwalithi ye-insulation ngaphambi kokuba iphume esitshalweni.
Iziqondiso Zokufaka Nokuhlanganisa
Ukuhlola imvelo kuyisinyathelo sokuqala ekufakweni okufanele ukuqinisekisa ukuthi izimo endaweni zingaphakathi kwemingcele yokusebenza. Ama-epoxy transformers angabhekana nokushisa okuphezulu kunezinye izinketho eziningi, kodwa adinga ukugcinwa ezindaweni ezinomoya omuhle ukuze amazinga okushisa angakhuphuki ngokushesha kakhulu. Ukuze ukufakwa kwemishini kusebenze, okunamathiselwe kumele kube namandla ngokwanele ukumelana nokuzamazama komhlaba kanye namandla kagesi ngesikhathi semijikelezo emifushane. Amabhulokhi ahlukene e-terminal kumele asetshenziswe ukugcina imijikelezo yokulinganisa kanye nokuphepha ekuxhumekeni ngengozi komunye nomunye entanjeni yesibili. Ukusebenzisa ukuxhumana okuyinhloko kwe-cable socket okusebenza nama-plug e-elbow e-ZT-15/200 noma izixhumi zohlobo lwe-T ukuze kube nemisinga ephezulu kwenza ukufakwa kube lula futhi kwenza kube lula ukwenza izinguquko esikhathini esizayo.
Ukuqhathanisa ama-Epoxy Resin Indoor Voltage Transformers nezinye izinhlobo
Ukuze ukhethe ubuchwepheshe obuhle kakhulu be-indoor voltage transformer, udinga ukwazi ukuthi yiziphi izinzuzo nezinkinga zomklamo ngamunye. Zonke lezi zobuchwepheshe zinezinzuzo nezinkinga zazo ezenza zibe ngcono noma zibe zimbi kakhulu ezintweni ezahlukene.
Amamodeli e-Resin Agcwele Amafutha Uma Eqhathaniswa ne-Epoxy
Ama-transformer acwiliswe ku-oyela asesetshenziswe isikhathi eside futhi abonakala ethembekile ekufakweni kwangaphandle. Kodwa ukuwasebenzisa ngaphakathi kwenza ukuphepha komlilo kubaluleke kakhulu futhi kudinga ingqalasizinda ukuvimba ukuvuza. Ukunakekelwa njalo nokuhlolwa kuka-oyela kwengeza emsebenzini okudingeka wenziwe. Izinketho ze-epoxy resin ziqeda lezi zinkinga ngenkathi zigcina izinga elifanayo lokusebenza kukagesi. Izindleko ezengeziwe zobuchwepheshe be-epoxy zivame ukuba zifanele ezindaweni lapho imithetho yokuphepha komlilo idinga izinhlelo zokucindezela ezibizayo zemishini egcwele uwoyela.
Ama-Transformer Afakwe Umoya Owomile
Ama-transformer ayisisekelo ohlobo olomile anomshini wokushisa umoya noma i-cast resin ayizinketho ezishibhile ezingasetshenziswa emisebenzini engadingi mzamo omkhulu. Ngenxa yokuthi athatha isikhala esiningi futhi awamelani nokungcola kwemvelo, awakwazi ukusetshenziswa ezindaweni zezimboni ezinzima noma ezindaweni ezinesikhala esincane. Ama-transformer e-Epoxy resin yangaphakathi anokumelana okungcono kokukhipha ingxenye futhi aphila isikhathi eside ekushiseni. Lokhu kuyiqiniso ikakhulukazi ezindaweni ezinomswakama omningi, lapho umswakama ongena kumayunithi ohlobo olomile usheshisa inqubo yokuguga.
Ukuqhathaniswa kwamamethrikhi okusebenza
Kunezindlela eziningana zokulinganisa ukusebenza okudingeka zibhekwe ngokucophelela lapho kuqhathaniswa okunikezwayo kwabaphakeli abavela ezinkampanini ezifana ne-Siemens, i-ABB, i-Schneider, ne-Xi'an Xikai. Isigaba sokunemba sinomthelela oqondile ekunembeni kwamamitha emali engenayo. Amayunithi anesigaba sokunemba esingu-0.2 afanele ukusetshenziswa kokudluliselwa kokugcinwa. Umthamo omkhulu womthwalo oqhubekayo usekelwe emikhawulweni yokunyuka kokushisa. Amanani okumelana ne-short-circuit aqinisekisa ukuthi uhlelo luzoqhubeka nokusebenza ngemva kwephutha. Amanani okukhipha ingxenye angaphansi kwe-10pC asho ukuthi umkhiqizo wenziwe kahle futhi uzohlala isikhathi eside. Abakhiqizi babeka ukholo olukhulu emikhiqizweni yabo ngokunikeza iziqinisekiso ezihlala phakathi kwezinyanga ezingu-12 nezingu-24.
Imibandela Yokukhetha Ecacisiwe Yohlelo
Kumafektri ezimboni anezinjini zokushayela eziguquguqukayo ezibangela ukuphambuka kwe-harmonic, adinga ama-transformer anomthamo omkhulu womthwalo ukuze agcine ukunemba kwawo lapho izimo zingekho ngaphansi kwe-sinusoidal. Izikhungo zedatha zizama ukushiya umkhondo omncane ngangokunokwenzeka futhi zisebenze nezinhlelo zokulinganisa zedijithali. Iziteshi zezinsiza zigxila ekulungiselelweni kwesilinganiso esiphindwe kabili okuvumela igridi ukuthi ihlelwe kabusha ngaphandle kokushintsha noma yimiphi imishini. Lapho izinkampani ze-EPC zithenga izingxenye zamaphrojekthi amaklayenti, zilinganisa izindleko zokuqala nenani esikhathini sokuphila komkhiqizo, zikhetha abahlinzeki abanokusekelwa okuhle kochwepheshe kanye nezikhathi zokuhola ezimfushane (ngaphansi kwamasonto ayi-12).
Izindlela Ezinhle Zokuthenga Nokulungisa
Uma uthenga ama-transformer e-epoxy resin yangaphakathi asebenzisa i-voltage ngendlela efanele, awugcini nje ngokuxoxisana ngamanani; ubheka nabahlinzeki, uqinisekise ukuthi imininingwane iyahlangatshezwa, futhi uhlele impilo yama-transformer. Le mikhuba isiza abantu ukuba bagweme ukwenza amaphutha abiza imali eningi futhi basebenzise kahle kakhulu ukuqaphela inani lesikhathi eside.
Uhlaka Lokuhlola Lomhlinzeki
Amaphothifoliyo ezitifiketi awubufakazi obuqondile bekhono lokwenza okuthile. Ukuba nesitifiketi sokuphathwa kwekhwalithi ye-ISO 9001 kuqinisekisa ukuthi izindlela zokusebenza zihlala zifana. Ilayisensi yezemvelo ye-ISO 14001 ikhombisa ukuthi uzinikele ekusebenziseni izindlela eziphephile. Impilo nokuphepha kwabasebenzi kuvikelwe ukuvunyelwa kwe-ISO 45001. Izitifiketi zomkhiqizo ezifana nokumaka kwe-CE, ukufakwa ohlwini kwe-UL, kanye nokuhambisana ne-RoHS kwenza kube lula ngabalawuli ezimakethe eziqondiwe ukuvuma umkhiqizo. Ukuqoqwa kwempahla yobuhlakani yabahlinzeki, ikakhulukazi amalungelo obunikazi amafomula e-epoxy ahlukile noma izindlela zokubopha, kubonisa ukuthi bathuthuke kangakanani kwezobuchwepheshe futhi banobuchule kangakanani.
Ukuqinisekiswa Kwemininingwane Yobuchwepheshe
Ukubuyekezwa okuphelele kwezincazelo kuvimbela abantu ukuba bangadideki, okungalibazisa iphrojekthi. Ukunemba kwesilinganiso samandla kagesi phezu kobubanzi bomthwalo ogcwele, kusukela ku-25% kuya ku-100% womthwalo omkhulu, kuqinisekisa izilinganiso ezinembile ngisho nalapho izimo zesistimu zishintsha. Izinga lokushisa eliphakeme kakhulu elingakhuphuka lilinganiswa yisigaba salo sokushisa. Izinto ezilinganiselwe i-Class E (120°C) kanye ne-Class F (155°C) zingasetshenziswa ezilungiselelweni ezahlukene zokufakwa. Ukuhlolwa kokufaneleka kokuzamazama komhlaba kuqinisekisa ukuthi izakhiwo ziphephile ezindaweni ezivame ukuzamazama komhlaba. Lokhu kubaluleke kakhulu ezindaweni ezisentshonalanga ye-United States.
Ukuphathwa Kwezinto Zokuhamba kanye Nesikhathi Sokuhola
Ngokuvamile, izinto zekhathalogi zithunyelwa zingakapheli amasonto angu-8 kuya kwangu-12. Ngakolunye uhlangothi, ukucushwa okwenziwe ngokwezifiso kudinga amasonto angu-14 kuya kwangu-16 obunjiniyela, ukuthenga, kanye nokukhiqiza. Izikhathi zokushintsha eziphuthumayo ziyancishiswa lapho abahlinzeki begcina izikhungo zokusabalalisa izinto zesifunda zivulekile. Izinkinga zokuhamba zifaka phakathi imikhawulo yosayizi wezinto zokuphakamisa izimpahla kanye nesisindo esiphezulu samathuluzi okuphakamisa. Ukuthunyelwa akulimazi izindawo zokuvikela ze-epoxy ezibuthakathaka uma kunemithetho ecacile yokuthi zingapakishwa kanjani.
Ukuqaliswa Kohlelo Lokulungisa
Ezimweni ezivamile, ama-transformer e-epoxy resin awadingi ukulungiswa, kodwa adinga ukuhlolwa njalo ukuqinisekisa ukuthi asasebenza kahle. Njalo ngonyaka, izinhlolovo ze-thermographic zibheka amaphethini okushisa angajwayelekile angasho ukuthi ukuxhumana kukhululekile noma kunezinkinga ngaphakathi. Ukuqhekeka noma ukushintsha kombala ebusweni be-epoxy kungabonakala ngaphansi kwe-microscope, okungasho ukuthi kushise kakhulu noma kuyonakaliswa yindawo ezungezile. Ukuhlolwa kwesibili kwezintambo kuqinisekisa ukuthi ukuphela kuqinile futhi akukho ukugqwala. Ukuhlola isimo sokushisa njalo eminyakeni emihlanu ngemishini ye-voltage emelana nemvamisa yamandla kuyadingeka, kodwa kuyafaneleka ngoba kudinga isevisi yokumisa isikhashana esifushane nokusebenzisa imishini yokuhlola ekhethekile ye-high-voltage.
Izithiyo Ezivamile Zokufakwa
Uma ukufakwa kwenziwa kabi, kungabangela ukucindezeleka komshini okungaholela ekuqhekekeni okusakazeke ngaphakathi kwe-epoxy matrix. Ukuze kusabalale imithwalo ngokulinganayo, amathuluzi okuphakamisa kumele axhumane nezindawo ezithile zokuphakamisa. Lapho ama-transformer egcinwa ezindaweni ezingenayo i-conditioner, abonakala ezinguqukweni zokushisa kanye nokwakheka komswakama ngaphambi kokuba afakwe. Amaphutha okuxhuma, ikakhulukazi lapho i-polarity ibuyiselwa emuva ekucushweni kwe-dual-ratio, aholela ekulinganisweni okungalungile okwenza ukuhlanganiswa kokuvikela kungathembeki. Ukungafakwa kahle kwesisekelo kungadala ukushaqeka kanye nokuphelelwa ngamandla kwesikhashana okusheshisa ukuguga.
Le mikhuba yokuthenga izinto nokuzigcina zisesimweni esihle isiza amaqembu obunjiniyela ukukhetha izixazululo ezifanele, abaphathi bezikhungo bagcina izinsizakalo zisebenza kahle, kanti izinkampani zezinsiza zisebenzisa ngokugcwele izinhlelo zazo zokuphatha izimpahla. Indlela ehlelekile yehlisa izindleko eziphelele zobunikazi futhi iphakamisa izinga lokutholakala kokusebenza.

Isiphetho
Ama-transformer e-voltage yangaphakathi e -epoxy resin ayibuchwepheshe obuthuthukisiwe obukhonjiswe buthembekile, buphephile, futhi busebenza kahle ezindaweni eziningi ezahlukene. Ukushisa kwawo okungashisi, ukusebenza okungenakulungiswa, kanye nosayizi omncane kuhlangabezana nezidingo zezinkampani zobunjiniyela, izinkampani zezinsiza, kanye nezindawo zezimboni. Amamodeli angu-35kV anamakhono okulinganisa isigaba sokunemba esingu-0.2/0.5 kanye nokuhambisana ne-IEC 61869 kunikeza izinhlelo zamandla zanamuhla ushintsho olunembile lwe-voltage. Ukunaka kakhulu ukukhetha umhlinzeki ofanele, ukuqinisekisa ukuthi imininingwane ilungile, kanye nokulandela imikhuba emihle yokufaka kuqinisekisa umsebenzi ophumelelayo kanye neminyaka yesevisi engenazinkinga.
Imibuzo Evame Ukubuzwa
1. Yisiphi isigaba sokunemba okufanele sichazwe ngezicelo zokulinganisa imali engenayo?
Ukuze kusetshenziswe okudinga ukulinganiswa kwebanga lokugcina imali engenayo, udinga ama-transformer ekilasi lokunemba angu-0.2 angagcina ukunemba kwawo kungaphakathi kuka-±0.2% kusukela ku-25% kuya ku-100%. Le ncazelo iqinisekisa ukuthi ukukhokhisa kulungile nokuthi yonke imithetho iyalandelwa ezivumelwaneni zebhizinisi phakathi kwezinsizakusebenza kanye nabasebenzisi abakhulu bezimboni.
2. Ama-transformer e-epoxy resin asebenza kanjani ezindaweni eziphakeme?
Ama-transformer ajwayelekile e-voltage yangaphakathi enziwe nge-epoxy resin asebenza njalo ekuphakameni okufika kumamitha ayi-1,000 ngaphandle kokulahlekelwa amandla. Uma ufaka ezindaweni eziphakeme, ikakhulukazi ngaphezu kwamamitha ayi-2,000, udinga imiklamo efana ne-plateau enezikhala ezinkulu ezizungezile ngaphandle ukuze kulungiswe ubuningi bomoya obuphansi. U-Xi'an Xikai wenza imishini ekhethekile yama-plateau angasebenza ezindaweni eziphakeme ezifika kumamitha ayi-4,000.
3. Ingabe la ma-transformer angahlanganiswa nezinhlelo zokuzenzakalela zesiteshi esincane sedijithali?
Ama-transformer e-epoxy resin anamuhla angasebenza namadivayisi edijithali ngoba imiphumela yawo yesibili iyahambisana futhi ingaxhuma kuma-electronics ahlakaniphile. Ngokucushwa kwesilinganiso esiphindwe kabili, igridi ingahlelwa kabusha ngaphandle kokushintsha noma yimaphi amathuluzi angempela. Eziteshini ezincane ezihambisana ne-IEC 61850, izakhiwo zokukhipha ingxenye ephansi zivimba ukuphazamiseka kwe-electromagnetic okungaphazamisa amasignali okudlulisa edijithali.
Xhumana noXi'an Xikai ukuze uthole izidingo zakho ze-Indoor Voltage Transformer
I-Xikai Medium & Low Voltage Electric Co., Ltd. ikulungele ukukusiza ngezidingo zesistimu yakho yamandla ngokunikeza izinketho ze-epoxy resin yangaphakathi ezivunyelwe nguhulumeni . Amamodeli ajwayelekile angu-35kV esingawenza anokusebenza kwekilasi lokunemba okungu-0.2/0.5, ahambisana ne-IEC 61869, futhi afakazelwe ukuthi asebenza ngokwethembeka ezindaweni zezimboni, zezinsizakusebenza, kanye nezebhizinisi. Siyaqonda izidingo eziqinile zabasebenzi abathengayo ngoba sinobuchwepheshe obuningi obunelungelo lobunikazi, izitifiketi ze-ISO 9001/14001/45001, kanye nolwazi oluningi lokusebenza nezinhlelo ze-State Grid.
Ithimba lethu lochwepheshe linikeza ukwesekwa okugcwele kobunjiniyela bezinhlelo zokusebenza, okuhlanganisa nokusiza ekudalweni kwezincazelo, izifundo zokuxhumanisa ukuzivikela, kanye nokwakhiwa kokucushwa okwenziwe ngokwezifiso. Izindlela zethu zokukhiqiza ziguquguquka kakhulu, ngakho-ke zingahlangabezana nezidingo zanoma yimuphi umsebenzi, kungakhathaliseki ukuthi udinga izinto zekhathalogi ezivamile ngezikhathi zokuhola zamaviki ayi-12 noma imishini ekhethekile elinganiselwe i-plateau yokufaka ezindaweni eziphakeme. Njengomhlinzeki owaziwayo wama-transformer kagesi angaphakathi, silandela izinqubo zokulawula ikhwalithi eziqinile ukuqinisekisa ukuthi yonke iyunithi ihlangabezana nezindinganiso zomhlaba wonke ngaphambi kokuba ithunyelwe.
Xhumana nethimba lethu lokusekela elizinikele ku-serina@xaxd-electric.com , amber@xaxd-electric.com , noma luna@xaxd-electric.com ukuze uxoxe ngezinkinga onazo ngohlelo lwakho lokusebenza. Singathanda ithuba lokukukhombisa ukuthi ama-voltage transformer e-Xi'an Xikai aklanywe ngokunemba angenza kanjani ingqalasizinda yakho kagesi ibe nokwethenjelwa kakhulu ngenkathi ehlisa izindleko esikhathini sayo sokuphila.

Okubhekwayo
1. I-IEEE Standards Association. "Umhlahlandlela we-IEEE Wokusetshenziswa Kwama-Instrument Transformers Ezinhlelweni Zamandla." IEEE Std C57.13-2016, Isikhungo Sonjiniyela Bakagesi Nabasebenza Ngogesi, 2016.
2. IKhomishini Yobuchwepheshe Be-Electrotechnical Yomhlaba Wonke. "Ama-Transformer Ezinsimbi—Ingxenye 1: Izidingo Ezijwayelekile." I-IEC 61869-1:2020, IKhomishini Yobuchwepheshe Be-Electrotechnical Yomhlaba Wonke, eGeneva, 2020.
3. UZhang, uWei noLiu, eHongming. "Izinto Ezihlanganisiwe Ezithuthukisiwe Ze-Epoxy Resin Zokusetshenziswa Kokushiswa Kwe-High Voltage." Ijenali Yobunjiniyela Bogesi Nobuchwepheshe, umqulu 15, cha. 3, 2020, amakhasi 1247-1260.
4. Inhlangano Kazwelonke Yabakhiqizi Bakagesi. "Ama-Instrument Transformers: Izidingo, Amagama Asetshenziswayo, kanye Nezinqubo Zokuhlola." I-NEMA Standards Publication TR 1-2016, Inhlangano Kazwelonke Yabakhiqizi Bakagesi, Rosslyn, 2016.
5. Chen, George noDavies, Anthony. "Ithonya Lamaphutha Ezicini Zokuqhekeka Kwesikhathi Esifushane kanye Nokusebenza Kwesikhathi Eside Kwe-DC Kwe-LDPE kanye ne-XLPE." I-IEEE Transactions on Dielectrics and Electrical Insulation, vol. 27, cha. 4, 2020, amakhasi 1184-1192.
6. Isikhungo Sokucwaninga Amandla Kagesi. "Umhlahlandlela Wokulungisa I-Transformer." Umbiko Wobuchwepheshe be-EPRI 1021870, Isikhungo Sokucwaninga Amandla Kagesi, ePalo Alto, 2018.