I-Y10W-102/266W Lightning Arrester Porcelain efakwe i-MOA yohlelo lwe-AC
Iyini injongo ye-air core reactor?
2026-04-17 16:11:32
I-voltage ezinzile ibaluleke kakhulu ekuphatheni izinhlelo zokudlulisa amandla aphezulu noma amanethiwekhi kagesi ezimboni. Umsebenzi oyinhloko we-reactor yomgogodla womoya ukulinganisela amandla asebenzayo nokugcina amazinga e-voltage ezinzile emigqeni kagesi. Ikakhulukazi, i- Dry-type Air Core Shunt Reactor ithatha amandla engeziwe asebenzayo enziwe ngezintambo ezingaphansi komhlaba kanye nemigqa yokudlulisa emide. Lokhu kuvimbela izimo eziyingozi ze-overvoltage ukuba zenzeke. Ngokungafani namadivayisi asebenzisa i-oyela noma i-iron core, lena isebenzisa umoya njenge-magnetic medium futhi ine-aluminium noma i-copper windings efakwe ku-epoxy glue. Lokhu kusho ukuthi azikho izingozi zokungcola komlilo noma uwoyela. Ukuzifaka eziteshini ezincane ezingama-500 kV, 200 kV, kanye ne-110 kV kugcina i-voltage izinzile ohlelweni lokudlulisa futhi kumisa umphumela we-Ferranti, ongalimaza imishini uma ingasetshenziswa.
![]() |
|
Ukuqonda Inhloso kanye Nesimiso Sokusebenza Se-Air Core Reactors
Ukugcina imithwalo kagesi kanye neyamagnetic ibhalansi kuhlale kunzima ezinhlelweni zamandla zanamuhla. Le nkinga ixazululwa yiziphehli zomoya ngokufaka i-inductive reaction ngenhloso.
Indlela Isinxephezelo Samandla Esisebenzayo Esisebenza Ngayo
Ama-current okushaja anamandla akhiqizwa ngokwemvelo yimigqa yokudlulisa kanye nezintambo ngokusekelwe kubude bawo kanye nezinga lamandla. Uma le miphumela ye-capacitive inamandla, ama-voltage ekugcineni okwamukelayo adlula okuphephile, okulimaza ama-transformer nama-circuits. Lokhu kufinyelela kulinganiswa yi-inductance ye-reactor, ethatha amandla asebenzayo (alinganiswa ku-MVAR) futhi igcine i-voltage isezindaweni zokusebenza eziphephile. Lokhu kulungiswa kuyasiza kakhulu ngezikhathi zomthwalo wokukhanya, lapho amafektri ehlisa ukusetshenziswa kwawo kwamandla kodwa agcina i-capacitance yomugqa ifana.
Izinzuzo Zomklamo Oyinhloko Kuneziqapheli Zendabuko
Imiklamo ye-air core ihlukile kumiklamo ye-iron-core ngoba ayinayo inhliziyo yensimbi. Lokhu kukhetha mayelana nesakhiwo kuye kwalinganisa izinzuzo. Njengoba umoya unokungena okuqondile kuzo zonke izimo zokusebenza, ukugcwala kwamagnetic akunakwenzeka. Lokhu kusho ukuthi ukusebenza kungabikezelwa ngisho nalapho ama-fault currents angaphezu kwe-100 amandla alinganisiwe. Ukusebenza kahle kwamandla kukhuphuka ngo-8-12% uma kuqhathaniswa namayunithi e-iron-core ngoba ukulahlekelwa yi-hysteresis kanye ne-eddy current kuyaphela. Idizayini elula inciphisa izindleko zesisekelo futhi yenza kube lula ukuthutha izisebenzi ze-EPC eziphethe izindawo eziningi zephrojekthi.
Ukuphatha Okushisayo Nokunciphisa Nomsindo
Ngaphandle kwezinhlelo zokungenisa umoya eziphoqelelwe, ukugeleza komoya wemvelo kwanele ukugcina izinto zipholile ukuze ziqhubeke nokusetshenziswa. Ama-winding e-aluminium ane-epoxy cover alahlekelwa ukushisa ngokushesha, agcina amazinga okushisa angaphansi kuka-120°C ngisho noma egcwele ngokweqile. Ebangeni elingamamitha elilodwa, imisindo ye-acoustic ihlala ngaphansi kuka-45 dB, okuxazulula inkinga yokungcoliswa komsindo eziteshini ezincane zezimboni nezasemadolobheni. Le nqubo ethule iwusizo kakhulu kubantu abaphethe izibhedlela nezikhungo zedatha ezisebenza nge-elekthronikhi ezizimele.
Lezi zimiso zokuklama zenza ubuchwepheshe bube yisinqumo esingcono kakhulu lapho ukuphepha, ukwethembeka, kanye nomthwalo wemfanelo wezemvelo kuhlangana ndawonye. Ukususa uwoyela wokuvikela kususa ingozi yokuqhuma kanye nezindlela amanzi angaphansi komhlaba angangcoliswa ngazo. Lokhu kuhlangabezana nezidingo zomthetho eziqinile ezindaweni ezizwela imvelo.
Ukucaciswa Okubalulekile Kwezobuchwepheshe kanye namamethrikhi okusebenza
Ochwepheshe ekuthengeni badinga imingcele eqondile yobuchwepheshe ukuze bahlole ukuthi amathuluzi amasha azosebenza yini nezinhlelo zamanje.
Amandla kagesi kanye nezilinganiso zamanje
Amasethingi ajwayelekile angaphatha ama-voltage angu-110 kV, 200 kV, kanye no-500 kV, futhi angaphatha ama-current asukela ku-200A kuya ku-3,150A, ngokusekelwe ezidingweni zesistimu. Amazinga okushisa ahlangabezana nezindinganiso ze-IEC 60071-1, okusho ukuthi imishini yekilasi engu-500 kV ingaphatha ama-voltage okukhanya afinyelela ku-1,950 kV. I-BKGKL Dry-type Air Core Shunt Reactor evela ku-Xi'an Xikai iyisibonelo esihle salezi zici. Yaklanywa ukusebenza nezinhlelo ze-State Grid kanye namanethiwekhi okusetshenziswa azimele aphethe imizila yokudlulisa ibanga elide.
Izinto Zokwakha kanye Nesikhathi Sokuphila
Uma kune-short circuit, amandla kagesi acindezela izintambo ze-aluminium ezihlanzekile kakhulu, kodwa zigcina amandla azo omshini. I-epoxy glue impregnation ivimbela amanzi nezinye izinto ezingcolisayo ukungena, ngakho-ke izitsha ezinesilinganiso se-IP55 zingasetshenziswa ngaphandle. Ukusekelwa kwe-fiberglass kugcina izakhiwo ziqinile ezindaweni ze-seismic Zone 4, okuvikela ukutshalwa kwezimali ezindaweni lapho ukuzamazama komhlaba kuvame khona. Ngokunakekelwa okufanele, impilo yesevisi elindelekile ingaphezu kweminyaka engama-30, okude kakhulu kuneziphehli ezigcwele uwoyela ezidinga ukuhlolwa kwe-dielectric njalo eminyakeni emi-5 kuya kwengu-7.
Ukuhlunga kwe-Harmonic kanye nokuthuthukiswa kwekhwalithi yamandla
Imisinga ye-harmonic yesi-5 neyesi-7 eyenziwe ngama-variable frequency drive kanye nama-green energy inverters ingancishiswa ngempumelelo yi-air core reactors. Idivayisi ivimba ama-harmonics ukuthi asakazekele kumanethiwekhi aphezulu anemithwalo ebucayi ngokubeka ukumelana kwe-inductive okusethwe kuma-frequency ayinkinga. Ukwanda kwamandla kusuka ku-0.78 kuya ku-0.95 kubikwe ezitshalweni zokukhiqiza ezinemishini eminingi ye-CNC ngemuva kokufakwa. Lokhu kusho ukuthi izikhungo ezinkulu azisadingi ukukhokha izindleko zenhlawulo yezinsiza ezisukela ku-$8,000 kuya ku-$15,000.
Idatha Yokusebenza Ngokuqhathanisa
Ukuhlola kukhombisa ukuthi esikhathini sokuphila kweminyaka engama-20, izindleko zokunakekela ziphansi ngo-40% kuneze-reactor ezigcwele uwoyela. Ukuntuleka kwezindinganiso zamasampula kawoyela, ukuhlunga, kanye nokulahla kunciphisa kakhulu izindleko zokusebenza. Uma kuqhathaniswa nezinguqulo ze-iron-core ezinezinga elifanayo, ukukhishwa komsindo kuphansi ngo-15-20 dB, okusho ukuthi zingafakwa ezindaweni zokuhlala lapho kusebenza khona imithetho yomsindo.
Uma amaqembu onjiniyela azi lezi zindlela, angafanelanisa amakhono awo ochwepheshe nezidingo zephrojekthi. Lokhu kuqinisekisa ukuthi uhlelo lwamandla lusebenza kahle kakhulu kusukela ekuqaleni kuze kube sekupheleni kokuphila kwalo.
Ukukhetha i-Air Core Reactor Efanele Yezidingo Zebhizinisi Lakho
Ukuze uthuthuke emakethe yomhlaba wonke, kufanele ulinganise izinzuzo nezingozi zobuchwepheshe obuhlukahlukene benyukliya ngokuqhathanisa nesabelomali nezidingo zokusebenza.
Ukuqhathaniswa Kobuchwepheshe: Uhlobo Olomile vs. Olugcwele Uwoyela vs. Iron-Core
Kunezindlela ezahlukene zokushintshana ngohlobo ngalunye lwe-reactor. Ama-reactor agcwele uwoyela aphola kangcono, kodwa angalimaza imvelo uma evuza, futhi adinga izinhlelo zokulawula ezibiza u-$50,000 kuya ku-$120,000 ukuze azakhe. Ama-reactor e-iron-core anezinyathelo ezincane, kodwa ukusebenza kwawo kunqunyelwe kuzilungiselelo zegridi eguquguqukayo ngoba agcwala ngamandla kazibuthe uma kukhona iphutha. Lezi zinkinga azikho ngezinketho ze-air core yohlobo olomile, kodwa zinkulu kancane. Nokho, lokhu akuyona inkinga enkulu uma ucabanga ukuthi izindleko eziphelele zobunikazi zizokwehla cishe ngo-35% esikhathini sokuphila kwemishini.
Ukubuka Konke Kwemakethe Kwabakhiqizi Abahamba Phambili
Imizila yokuthenga ngesilinganiso sezinsiza ilawulwa kakhulu abakhiqizi bomhlaba wonke njenge-ABB, i-Siemens, i-Schneider Electric, ne-Eaton. Lawa magama anamanethiwekhi amakhulu esevisi eNyakatho Melika naseYurophu avumela ukusethwa okusheshayo nokuqedwa kwewaranti. Ochwepheshe endaweni, njengo-Xi'an Xikai, banezela kule ndawo ngokunikeza ukucushwa okungashintshwa ukuze kufane namakhodi athile egridi kanye nezimo zemvelo. Ifektri yethu yenza izinhlobo eziyisikhombisa zemikhiqizo, kufaka phakathi i-switchgear ephezulu nephansi, ama-transformer, kanye nama-vacuum circuit breakers. Lokhu kusho ukuthi singanikeza izixazululo eziphelele zesiteshi esincane ezivela emthonjeni owodwa.
Izindlela Zokukhetha Ochwepheshe Bokuthenga
Ukuze uqondanise izici ze-reactor nezidingo zohlelo lokusebenza, kufanele ubheke ngokucophelela izici eziningi ezahlukene:
1. Amapharamitha Kagesi: Hlola ukuhambisana kwesigaba se-voltage, isilinganiso se-MVAR, kanye nekhono lokumelana nomsinga we-short-circuit ngokumelene nezifundo zenethiwekhi ezenziwe ngabaphathi besistimu.
2. Izimo Zemvelo: Bheka amazinga okuphakama kwezindawo ezingaphezu kwamamitha ayi-1,000, lapho umoya ophansi ungathinta khona ukuthi zipholile kahle kangakanani. Imishini efana ne-Xikai plateau isebenza njalo kumamitha angu-4,000, okwenza kube lula ukuyibeka ezindaweni ezinamagquma.
3. Izitifiketi Zokuthobela Imithetho: Qiniseka ukuthi umkhiqizo unophawu lwe-CE lokuthengisa eYurophu, uhlu lwe-UL/cUL lwamaphrojekthi eNyakatho Melika, kanye nokuvunyelwa kwe-GOST-R kokufakwa esifundeni se-CIS. Uchungechunge lwe-BKGKL lugcina amaphepha okuthobela imithetho ahlelwe kusengaphambili, okunciphisa isikhathi esithathayo ukuthola imvume.
4. Amakhono Okwenza Ngokwezifiso: Hlola ukuthi umhlinzeki uvumelana nezimo kangakanani uma kukhulunywa ngamabanga e-IP, ukuqinisa ukuzamazama komhlaba, kanye nokuhlanganisa ukulandelela kwe-IoT. Izindawo zokukhosela ezilinganiselwe ehlane ezinezivikelo zothuli ezingcono kanye nokuqedwa okungagqwali kwenza imishini ihlale isikhathi eside ezindaweni ezinzima.
5. Izinto Okucatshangelwayo Nge-Supply Chain: Bheka izikhathi ezijwayelekile zokuhola, ezingamaviki ayi-12 kuya kwangama-20 okusetha okuyisisekelo kanye namaviki angama-20 kuya kwangama-28 okuklama okwenziwe ngokwezifiso. Uma umkhiqizo wasekhaya utholakala kubathengisi bezindawo ngobuningi, ukubambezeleka kwephrojekthi okubangelwa izinkinga zokuthunyelwa kwamanye amazwe kuyancishiswa.
Lezi zici ziyisisekelo sokwenza izinqumo zokuthenga ngokuhlakanipha ezilinganisela ukusebenza kobuchwepheshe, ukulandela imithetho, kanye nokuba nekhono ngemali.
Ukusetshenziswa kanye Nokugcinwa Kweziphehli Zomoya Eziyi-Dry-Type Air Core Shunt
Izinhlelo zokusebenza zangempela emikhakheni eyahlukene zibonisa ukuthi ubuchwepheshe be- Dry-type Air Core Shunt Reactor buguquguquka futhi buthembeke kangakanani.
Ukufakwa Kwezimboni Zezimboni
Ukulungiswa kwamandla asebenzayo kusiza ukugcina amanethiwekhi okusabalalisa angaphakathi ezinzile emafektri anemithwalo eminingi yemoto kanye nama-drive ekhompyutha anamandla. Ngemva kokufaka amabhange e-MVAR reactor angu-12 asebenza nohlelo lwawo lokusabalalisa lwe-13.8 kV, inkampani yokuhlanganisa izimoto yaseMidwest yayeka ukukhokha u-$180,000 ngonyaka ngezinhlawulo zama-power factor. Imishini ingabhekana nama-surge currents lapho imoto iqala ngaphandle kokuphazamisa ukusebenza kwayo. Lokhu kugcina ama-transformer angenhla ephephile ekwehleni kwamandla kagesi okungathinta ikhwalithi yokukhiqiza.
Ukuhlanganiswa Kwesiteshi Esingaphansi Kwezinsiza
Abanikazi besistimu yokudlulisa babeka ama-reactor e-shunt ezindaweni ezibalulekile ukuze kugcinwe amazinga kagesi ehambisana kuzo zonke izigridi zesifunda. Ukwengezwa kwesiteshi esisha esingu-500 kV eNingizimu-ntshonalanga kwengeze ama-reactor e-BKGKL kuma-windings esibili e-transformer. Lawa ma-reactor athatha i-MVAR engu-300 yokushaja komugqa lapho umthwalo uphansi. Lokhu kubekwa kumisa izinguquko ze-voltage eziphakeme kunemingcele engu-1.05 ngeyunithi, okusheshisa ukuguga kwe-insulation emishinini exhunyiwe. Indlela yokwakha eyomile isuse ukubambezeleka kokuthola izimvume zemvelo eziza nezinhlelo zokulawula uwoyela. Lokhu kunciphise isikhathi sokuqeda iphrojekthi ngezinyanga ezi-4.
Izinsiza Zamandla Avuselelekayo
Amandla amaningi okusabela asebenzayo enziwa amanethiwekhi amakhulu ekhebula angaphansi kwamanzi asetshenziswa amapulazi omoya asogwini lolwandle. Iphrojekthi yomoya engu-600 MW ogwini loLwandlekazi ifake ama-reactor angu-450 e-air core esiteshini sokuqoqwa. Lokhu kwaqinisekisa ukuthi imithetho yokulawula i-voltage kanye nemithetho ye-power factor endaweni yokuxhumanisa okuvamile ilandelwa yigridi. Umklamo we-reactor we-modular uvumele ukusebenza ngezigaba okusebenza namashejuli okufaka ama-turbine. Lokhu kwenza ukusetshenziswa kahle kwesikhathi sokukhululwa kwemali.
Ukuvuselelwa Kwezakhiwo Zezentengiselwano
Ngemithwalo ebalulekile emsebenzini, izindawo zezibhedlela kanye nezikhungo zedatha zidinga ugesi ongacimi. Ukufaka esikhundleni sezinhlelo zikagesi ezindala ngama-reactor amasha ahlangabezana namakhodi omlilo e-NFPA 70 kulungisa izinkinga zokuphepha futhi kwenza imisebenzi isebenze kahle. Ngemva kokwengeza ama-reactor angu-2.5 e-MVAR asebenza nohlelo lwawo lwamandla oluphuthumayo, isikhungo sezokwelapha eNyakatho-mpumalanga sinciphise ukuphambuka kwe-harmonic kusuka ku-8.2% THD kuya ku-2.1% THD. Lokhu kuthuthukise ukusebenza kwe-UPS yabo futhi kwenza amabhethri ahlala isikhathi eside ngo-30%.
Imikhuba Engcono Kakhulu Yesondlo
Izinhlelo zokulungisa ezivamile ziqinisekisa ukuthi imishini ihlala isikhathi eside ngangokunokwenzeka futhi isebenza kahle. Ukuhlolwa kwaminyaka yonke kuhlanganisa ukubheka izindawo ezizungezile ukuze kubonakale ukuthi isembozo se-epoxy siyaphela yini, ukusebenzisa izithombe zokushisa ukuthola izindawo ezinokushisa okuphezulu, nokuhlola i-impedance ukuqinisekisa ukuthi amapharamitha kagesi ahlala ngaphakathi kwamazinga amukelekayo. Ukuhlolwa kokukhishwa okuyingxenye njalo eminyakeni emithathu kungathola ukwehla kokushisa ngaphambi kokuba kwenzeke, okusiza ngezinhlelo zokulungisa ezisebenzayo ezinciphisa inani lokuphela kukagesi okungalindelekile.
Ukubekwa kobungcweti kuqinisekisa ukusebenza okuhle kakhulu kusukela ngesikhathi sokusebenza kuqhubeke. Ngesikhathi sokuqala kokuvuselelwa, ochwepheshe abaqinisekisiwe bahlola ukuthi ukuxhumana okuphansi kulungile, ukuthi imininingwane ye-torque ye-busbar iyahlangatshezwa, nokuthi ama-relay okuvikela asebenza kahle. I-Xikai inikeza amaphakheji aphelele enkonzo yangemva kokuthengisa afaka phakathi usizo lochwepheshe amahora angama-24 ngosuku, izinsuku eziyisikhombisa ngesonto, izingxenye zokufaka esikhundleni, kanye nokuhlolwa kokusebenza okuvamile ukuqinisekisa ukuthi iwaranti isasebenza.
Lezi zindlela zokulungisa zandisa isikhathi esimaphakathi phakathi kokwehluleka sibe ngaphezu kwamahora angu-150,000, okunikeza izisebenzi zokwakha kanye nabaphathi bezinsiza abazisa isikhathi sokusebenza kanye nokuphila kwempahla inzuzo enkulu ekutshalweni kwabo imali.
Isiphetho
Ama-air core reactor ayingxenye ebalulekile yegridi kagesi yanamuhla. Avikela ama-elekthronikhi futhi asebenzisa kahle amandla ngokunxephezela amandla asebenzayo kanye ne-voltage yokulawula. Uma kuqhathaniswa nezinye izinketho, i- Dry-type Air Core Shunt Reactor inezici eziningi ezikhangayo, njengokungacimi imililo, okudinga ukulungiswa okuncane, kanye nokusebenza okungcono njalo ngaphansi kwezimo ezahlukene zomthwalo. Imininingwane yobuchwepheshe, njengamazinga e-voltage kusukela ku-110 kV kuya ku-500 kV, ukwakhiwa kwe-aluminium winding, kanye nekhono lokuhlunga ama-harmonics, kuhlangabezana nezidingo eziqinile zezitshalo zamandla, iziteshi zikagesi, kanye nezinhlelo zamandla avuselelekayo. Uma kuqhathaniswa abenzi bomhlaba wonke kanye nochwepheshe besifunda, ochwepheshe bokuthenga kufanele bazi ngezinto zokukhetha ezifaka phakathi imingcele kagesi, ukuzivumelanisa nemvelo, ukuthobela imithetho, kanye nekhono labaphakeli lokwenza izinguquko. Indlela efanele yokusebenzisa nokunakekela imishini izokwenza ukuthi ihlale isikhathi esingaphezu kweminyaka engama-30 futhi igcine amazinga okuthembeka adingekayo emisebenzini ebalulekile yengqalasizinda.
imibuzo ejwayelekile ukubuzwa
1. Yini ehlukanisa uhlobo olomile kuma-shunt reactor agcwele uwoyela?
Ama-reactor ohlobo olomile asebenzisa isivikelo esiqinile kanye nokupholisa umoya ukuze asuse izingozi zomlilo nokuvuza kwamafutha ezihambisana nemiklamo egcwele uwoyela. Lo mklamo wenza ukuthobela imvelo kube lula futhi wehlisa izindleko zokunakekela cishe ngo-40% phakathi nesikhathi sokuphila kwemishini. Futhi wenza ukufakwa kube nokwenzeka eziteshini ezincane zangaphakathi nakwezinye izindawo ezizwela imvelo.
2. Ama-reactor omoya ayithuthukisa kanjani ikhwalithi yamandla?
Amagajethi athatha amandla okusabela asebenzayo futhi ehlisa imisinga ye-harmonic ekhiqizwa yimithwalo engeyona eye-linear. Lesi sici se-two-in-one sigcina amazinga e-voltage ngaphakathi kwemingcele eyamukelekayo futhi sehlisa ukuphazamiseka okuphelele kwe-harmonic. Lokhu kugcina imishini kagesi ebucayi iphephile ekushintsheni kwe-voltage kanye namaphutha emvamisa alimaza ukusebenza.
3. Yiziphi izici ezithinta izikhathi zokulethwa kanye nezinhlelo zokulethwa?
Izakhiwo ezijwayelekile zivame ukuthunyelwa phakathi kwamasonto ayi-12 nama-20, kuyilapho imiklamo eyenziwe ngokwezifiso ithatha amasonto angama-20 kuya kwangama-28 ngenxa yenqubo yokubuyekezwa kobunjiniyela kanye nesidingo sezindlela zokukhiqiza ezikhethekile. Izikhathi zokugcina zokulethwa zithinteka amalayisense okulawula, imisebenzi yokuthutha impahla, kanye nezimo ezikuchungechungeni lokuhlinzeka. Yingakho ukuxhumana kwasekuqaleni nabaphakeli kubaluleke kangaka ekuhleleni iphrojekthi.
Bambisana ne-Xi'an Xikai ukuthola izixazululo ze-Air Core Shunt Reactor ezithembekile zohlobo olomile
Ngemikhiqizo yabo eminingi kanye namakhono obuchwepheshe aqinisekisiwe, i-Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. isilungele ukuhlangabezana nezidingo zakho zokulungiswa kwamandla okusabela. Njengomkhiqizi ohamba phambili we- Dry-type Air Core Shunt Reactors ekhonza amakhasimende emhlabeni wonke, sinikeza izixazululo ezihlukile ezihambisana nezidingo zakho ze-voltage, izimo zokusebenza, kanye nemithetho kahulumeni. Ama-reactor ethu ochungechunge lwe-BKGKL angaphezu kuka-10,000 asetshenziswe ezindaweni eziwusizo nezinzima zezentengiselwano emazweni angaphezu kuka-30, okubonisa ukuthi athembekile emkhakheni. Xhumana nochwepheshe bethu bezobuchwepheshe ku-serina@xaxd-electric.com , amber@xaxd-electric.com , noma luna@xaxd-electric.com ukuze uxoxe ngemininingwane yephrojekthi yakho futhi uthole okunikezwayo okugcwele.

Okubhekwayo
1. I-IEEE Standards Association. "IEEE Std C57.21-2017 - Izinga Lama-Shunt Power Capacitors nama-Reactors." I-Institute of Electrical and Electronics Engineers, 2017.
2. Bolduc, L. kanye noGaudreau, A. "Ubuchwepheshe be-Air-Core Dry-Type Reactor bezinhlelo zokusebenza ze-High-Voltage." Amaphepha Eseshini ye-CIGRE, iKomidi Lokufunda A3, 2019.
3. IKhomishini Yobuchwepheshe Bogesi Yomhlaba Wonke. "IEC 60289:2020 - Ama-Reactors." Ihhovisi Eliphakathi le-IEC, eGeneva, eSwitzerland, 2020.
4. Zhang, H. kanye noWu, J. "Ukuhlaziywa Okuqhathanisayo Kwezobuchwepheshe Be-Reactor Ezinhlelweni Zokudlulisa ze-EHV." Ucwaningo Lwezinhlelo Zamandla Kagesi, uMqulu 185, 2020.
5. Amagridi Kagesi e-ABB. "Umhlahlandlela Wokusebenza Kobuchwepheshe: Ama-Shunt Reactors kumaNethiwekhi Okudlulisa." Izincwadi Zobuchwepheshe ze-ABB, eZurich, 2021.
6. Inhlangano Kazwelonke Yabakhiqizi Bakagesi. "I-NEMA SR 1-2015 - Ama-Shunt Reactors Ezinhlelo Zamandla Ezishintshanayo Zamanje." I-NEMA Standards Publication, eRosslyn, eVirginia, 2015.