umkhiqizoPic

I-High Voltage Shunt Capacitor

1. Imvamisa engu-60Hz.
2. Ukuphambuka komthamo -5% ~ + 10%.
3.Ubuningi bamanje obungu-2.5×In.
Ifakwe ama-resistors okukhipha amandla 4. Ihlanganiswe namadivayisi okuvikela asebenza ngokweqile.
5. Ukusebenza okuhle kakhulu kokuzilapha kanye nokuphila isikhathi eside kwenkonzo.
6. Isici sokulahlekelwa okuphansi, umklamo wohlobo olomile ngokwakhiwa okungenawo amanzi.
7. Ifakwe ama-resistor okukhipha.
  • Ukulethwa Okusheshayo
  • Ukuqinisekisa ikhwalithi
  • Isevisi yamakhasimende engu-24/7

Umkhiqizo Isingeniso

I-High Voltage Shunt Capacitor - Izixazululo Zekhwalithi Yamandla Ochwepheshe

Umkhiqizo Isingeniso

Ingabe ubhekene nezijeziso zama-power factor noma ukungabi namandla kwe-voltage kunethiwekhi yakho kagesi? I-High Voltage Shunt Capacitor yethu yenzelwe ukuxazulula lezi zinselele ezibalulekile. Le ngxenye kagesi ekhethekile esebenza ngaphandle kokusebenza isebenza kahle ezinhlelweni zama-voltage aphakathi kuya kwaphezulu, ngokuvamile kusukela ku-1kV kuya ku-500kV. Ngokuxhuma ngokuhambisana nesistimu yakho yamandla, i-High Voltage Shunt Capacitor yethu inikeza isinxephezelo samandla esisebenzayo esithuthukisa ama-power factor, siqinise amazinga e-voltage, futhi sithuthukise ukusebenza kahle kwesistimu yonke yesikhungo sakho.

Ama-capacitor ethu abhekana nezinkinga ezibaluleke kakhulu embonini: ukulahlekelwa kokudluliselwa kwamandla, ukwehla kwamandla kagesi, kanye nokulinganiselwa kwamandla. Uzosusa izinhlawulo zamandla abizayo ngenkathi ukhulisa amandla akho engqalasizinda akhona. Ngokusebenza okuphezulu kokuziphilisa kanye nokuphila isikhathi eside kwenkonzo, lawa mayunithi ahlinzeka ngokusebenza okuthembekile ezindaweni zikagesi ezidinga amandla.

Imininingwane Technical

Ipharamitha Ukucaciswa
Voltage Kulinganiselwe ngo- 3kV - 35kV ngeyunithi ngayinye
imvamisa 50 / 60Hz
Ukuchezuka kwe-Capacitance -5% ukuya +10%
I-Loss Factor (tan δ) ≤ 0.0002 (0.02%)
Okuphezulu Kwamanje 2.5 × Ngaphakathi
Operating Temperature -40 ° C kuya ku-55 ° C
Isistimu ye-Dielectric I-BOPP yefilimu yonke enoketshezi lokwenziwa
Resistance ukwahlukanisa Idizayini yokumelana okuphezulu
Ukuvumelana Kwemigomo I-IEC 60871, IEEE Std 18, GB/T 11024

Izici Eziyinhloko Nezinzuzo

Ubuchwepheshe Bokushelela Okuthuthukisiwe

Amayunithi ethu afaka ifilimu ye-polypropylene (BOPP) eqondiswe kabili enama-electrode e-aluminium foil. Uketshezi olubolile olufakwe ku-vacuum lususa izikhala zomoya futhi luvimbele ukukhishwa kwengxenye.

Izinhlelo Zokuvikela Eziphakeme

I-capacitor ngayinye ihlanganisa ama-resistors ahlanganisiwe okukhipha kanye namadivayisi okuvikela i-over-voltage azimele. Ubuchwepheshe be-fuse yangaphakathi buhlukanisa amaphutha ngaphandle kokuthinta ukusebenza kwebhange lonke.

Ukuqina Okuyingqayizivele

Ukwakhiwa kohlobo olomile, olungenawo amanzi avuzayo kuqinisekisa ukusebenza okungenawo amanzi agciniwe. Amakesi ensimbi engagqwali ahlanganiswe nge-TIG anobuchwepheshe bokuvala kabili aqinisekisa ukuthi akukho manzi avuzayo eminyakeni engaphezu kwengu-20.

Ukusebenza Okuphansi Kokulahlekelwa

Ukulahlekelwa yi-dielectric okuphansi kakhulu kunciphisa ukumoshwa kwamandla ngenkathi kukhulisa ukusebenza kahle ohlelweni lwakho lwamandla.

Izicelo Ezisebenzayo

Iziteshi ezisetshenziswayo

Iziteshi ezincane ezinkulu zisebenzisa amabhange ethu e-capacitor ukulawula amaphrofayili e-voltage kuwo wonke amanethiwekhi okudlulisa. Uzonciphisa ukulahlekelwa kwesistimu futhi ugcine imikhawulo ye-voltage phakathi nezikhathi zesidingo esikhulu.

I-Heavy Industrial Manufacturing

Imishini yokugaya insimbi kanye nemisebenzi yokumba ithembele ezinhlelweni zethu ze -High Voltage Shunt Capacitor ukuze ikhokhele ukuguquguquka komthwalo okusheshayo okuvela kuma-arc furniture kagesi kanye nama-motor amakhulu. Umklamo oqinile umelana nokungcola kukagesi kanye nokwanda kwesikhashana.

Ukuhlanganisa Amandla Avuselelekayo

Amapulazi omoya kanye nelanga afaka amabhange ethu e-capacitor eziteshini ezincane zokuqoqa ukuze aqinisekise ukuhambisana nekhodi yegridi futhi agcine i-voltage izinzile ezindaweni zokuxhuma naphezu kokukhishwa okuguqukayo okuvuselelayo.

Izinsiza Zezohwebo Nezimboni

Izitshalo zokukhiqiza, izikhungo zedatha, kanye nezakhiwo ezinkulu zezentengiselwano zisebenzisa lezi zinhlelo ukugwema izinhlawulo zezinsiza kanye nokuthuthukisa ikhwalithi yamandla.

Indlela Esebenza

I-High Voltage Shunt Capacitor yakho isebenza ngokugcina amandla kagesi ensimini yayo kagesi bese iwakhipha uma kudingeka. Lapho imithwalo ye-inductive idala ugesi ohlala isikhathi eside, i-capacitor inikeza ugesi oholayo ukuze ilinganisele uhlelo.

Inqubo iyenzeka ngokuzenzakalelayo futhi ishesha. Njengoba amandla esikhungo sakho ehla, i-capacitor iphendula ngokunikeza amandla asebenzayo. Lokhu kunciphisa ukugeleza kwamandla kagesi okuphelele, kunciphisa ukulahlekelwa futhi kuthuthukise ukuzinza kwamandla kagesi kuyo yonke inethiwekhi yakho kagesi.

Ama-resistors angaphakathi okukhipha achitha amandla agciniwe ngokuphephile lapho iyunithi inqanyuliwe, okuqinisekisa ukuphepha komqhubi ngesikhathi sezinqubo zokulungisa.

Ukwenza Kakhulu

Kwa-Xi'an Xidian Medium and Low Voltage Electric Co., Ltd., sigcina ukulawulwa kwekhwalithi okuqinile kulo lonke ukukhiqizwa. Izinqubo zethu zokukhiqiza eziqinisekiswe yi-ISO9001 ziqinisekisa ikhwalithi yomkhiqizo ehambisanayo kanye nokuthembeka.

Iyunithi ngayinye ihlolwa ngokuphelele okuhlanganisa amandla e-dielectric, ukunemba kwamandla, kanye nokuqinisekiswa kwezinto ezilahlekile. Sisebenzisa kuphela izinto zekhwalithi ephezulu ezitholakala kubahlinzeki abaqinisekisiwe ukuqinisekisa ukusebenza kwesikhathi eside.

Ithimba lethu lobunjiniyela elinolwazi liklama i-High Voltage Shunt Capacitor ngayinye ukuze ihlangabezane noma idlule amazinga omhlaba wonke ngenkathi ibhekana nezidingo ezithile zohlelo lokusebenza.

Kungani Khetha Us

Ukufakazelwa Kwethrekhi Okufakazelwe

Njengoba sinolwazi oluningi kakhulu ekukhiqizeni imishini kagesi, siyaqonda izinselele zakho futhi sinikeza izixazululo ezisebenza ngokwethembeka ezimweni zangempela.

Comprehensive Product Range

Iphothifoliyo yethu ihlanganisa izigaba ezingu-9 ezinezinhlobo ezingaphezu kwe-100, okusivumela ukuthi sinikeze izixazululo eziphelele zesistimu ezivela emthonjeni owodwa othembekile.

Ukusekela kwezobuchwepheshe

Ithimba lethu lobunjiniyela linikeza ukwesekwa okuqhubekayo kusukela ekukhetheni kokuqala kuze kufike ekufakweni nasekuqalisweni. Uzokwazi ukufinyelela isiqondiso sochwepheshe noma nini lapho kudingeka.

Ukuqinisekisa ikhwalithi

Yonke imikhiqizo ihlangabezana nezindinganiso zikazwelonke nezemboni ngezitifiketi ezifaka phakathi izinhlelo zokuphatha ze-ISO9001, ISO14001, kanye ne-OHSAS18001.

Imibuzo Evame Ukubuzwa

Q: Yikuphi ukunakekelwa okudingekayo kula ma-capacitor?

A: Umklamo wethu wohlobo olomile udinga ukulungiswa okuncane. Ukuhlolwa okubonakalayo kwaminyaka yonke kanye nokuhlolwa kukagesi okwenziwa njalo kuqinisekisa ukusebenza kahle kakhulu.

Q: Ingabe lawa mayunithi angabhekana nokuhlanekezelwa kwe-harmonic?

A: Yebo, ama-capacitor ethu angahlanganiswa nama-reactor ahlukanisiwe ukuze kuvinjelwe i-harmonic resonance futhi kuvikelwe emifuleni ye-harmonic.

Q: Injani impilo yesevisi ejwayelekile?

A: Ngokufakwa nokusebenza okufanele, lindela iminyaka engaphezu kwengu-20 yesevisi ethembekile evela kuma-capacitor ethu asezingeni eliphezulu.

U: Ingabe ninikeza ukucushwa okwenziwe ngokwezifiso?

A: Impela. Siklama amabhange e-capacitor ngokwezifiso ukuze sihlangabezane nezidingo ezithile ze-voltage, umthamo, kanye nezemvelo.

Xhumana nathi

Ukulungele ukuthuthukisa ukusebenza kahle kohlelo lwakho lwamandla nokuqeda izinhlawulo zama-power factor? Ochwepheshe bethu bezobuchwepheshe balinde ukuxoxa ngezidingo zakho ezithile futhi batusa ikhambi elifanele kakhulu le-High Voltage Shunt Capacitor yesicelo sakho.

Xhumana nathi namuhla ku-serina@xaxd-electric.com ukuze uhlele ukubonisana futhi uthole isiphakamiso sobuchwepheshe esiningiliziwe esifanela izidingo zakho.

Thumela