TBB10 High Voltage Reactive Power Akpaaka Ngwa nkwụghachi ụgwọ
Nkwụghachi Ụgwọ Capacitor HV Setị zuru oke
2. Ugboro: 50Hz.
3. Ike: 100–10,000kVar.
4.Ambient okpomọkụ: -25 ℃ ~ + 45 ℃;
5. Nhọrọ reactor:.
Mbelata nke inrush: 0.1–1% mmeghachi omume.
Mgbochi nke ise+: mmeghachi omume 6%.
Mgbochi nke atọ+ nke harmonic: mmeghachi omume 12%.
- Nnyefe ngwa ngwa
- Quality nkwa
- 24/7 Ọrụ Ndị Ahịa
Product Okwu Mmalite
Nkwụghachi Ike HV - Ngwọta Ike Ọkachamara zuru oke
Product Okwu Mmalite
Mgbe ị na-eche nsogbu dị na ike dị elu ihu na sistemụ eletriki nwere ike, HV Capacitor Complete Set anyị na-enye ngwọta zuru oke. Emebere usoro ike eletriki a nke ọma maka sistemụ ike dị elu iji nye ụgwọ ọrụ ike na-emegharị ahụ ma melite ịdị mma nke voltaji. N'adịghị ka capacitors ndị na-anọpụ iche, set zuru oke a na-arụ ọrụ dị ka ngwọta turnkey zuru oke. Ị na-enweta capacitors shunt dị elu, reactors usoro, vacuum contactors, discharge coils, zinc oxide arresters, na units nchekwa njikwa nwere ọgụgụ isi niile dị n'ime kabinet dị n'otu.
Sistemụ anyị na-eleba anya n'ihe ndị kacha akpata nsogbu n'ụlọ ọrụ gị. Ọ na-ebelata obere ike Factor nke na-ebutekarị ntaramahụhụ ọrụ dị oke ọnụ. Ngwọta a na-ebelata mfu ahịrị I²R iji mee ka arụmọrụ nnyefe dịkwuo mma. Ị ga-eme ka ikike ojiji nke transformers isi gị dịkwuo elu ma na-eme ka voltaji busbar gị sie ike n'oge mgbanwe ibu kachasị elu. Ntinye nke reactors usoro a haziri ahazi na-enye sistemụ ahụ ohere igbochi mgbanwe harmonic, na-echebe grid gị pụọ na ihe egwu resonance.
Nka na ụzụ nkọwa
| oke | nkọwapụta |
|---|---|
| gosiri voltaji | 6kV - 10kV |
| Frequency | 50Hz |
| Oke ikike | 100 - 10,000 kVar |
| ihere okpomọkụ | -25â "ƒ ka + 45â" ƒ |
| Mmeghachi omume Mgbochi Inrush | 0.1% - 1% |
| Mgbochi Harmonic nke Ise | Mmeghachi omume 6% |
| Mgbochi nke Atọ nke Harmonic | Mmeghachi omume 12% |
| Nkuku Mfu (Tan δ) | ≤ 0.0003 (na voltaji a tụrụ aro 20°C) |
| Ọkwa nchekwa | IP4x maka ngwa ime ụlọ |
| Ndụ Imewe | Afọ 15-20 n'okpuru ọnọdụ nkịtị |
Isi atụmatụ na uru
Nhazi Njikọta Modular
Ị na-erite uru site na mbelata akara nwụnye na ọrụ dị mfe n'ebe ahụ. Ngwa anyị zuru oke na-ewepụ mgbagwoju anya nke ịhazi ọtụtụ ndị na-ere ahịa na akụkụ.
Sistemụ nchekwa dị elu
Nchedo kpakpando abụọ na-eji nchedo ọkụ eletrik na-adịghị mma na voltaji na-achọpụta ọdịda ihe dị n'ime ozugbo. Nke a na-egbochi ọdịda na-agbagharị agbagharị nke nwere ike imebi sistemụ gị dum.
Mgbochi Mmebi
Ihe ndị na-eme ka ihe ndị na-arụ ọrụ siri ike na-egbochi mmụba nke njikọ grid, na-echebe capacitors gị pụọ na ọnọdụ oke ibu. Ị na-enweta ọrụ a pụrụ ịtụkwasị obi ọbụlagodi na gburugburu ebe ọkụ eletrik na-eme mkpọtụ.
Nkwado gburugburu ebe obibi
Sistemụ anyị na-eguzogide uzuzu, iru mmiri, na mgbanwe okpomọkụ site na -40°C ruo +50°C. Ị nwere ike ịdabere na arụmọrụ na-adịgide adịgide n'ọtụtụ ọnọdụ ọrụ dị iche iche.
Ngwa Ngwa
Ọkụ ígwè na ọkụ eletrik
N'ụlọ ọrụ ígwè ebe ibu na-agbanwe ngwa ngwa na ọdịnaya harmonic dị elu, HV Capacitor Complete Set anyị na-eji vacuum switching na oge nzaghachi ngwa ngwa. Nhazi reactor kpọmkwem na-ejikwa harmonic nke atọ nke ọkụ arc mepụtara, na-eme ka voltaji kwụsie ike.
Ebe nchekwa Grid Ike
E tinyere ha n'ebe ndị na-arụ ọrụ n'ime obere ebe a na-arụ ọrụ, ha na-arụ ọrụ dị ka ebe a na-akwụ ụgwọ etiti. Ha na-achịkwa voltaji bọs na ike na-emegharị ahụ na akpaghị aka, na-ebelata mfu nnyefe n'ofe ahịrị dị anya.
Osisi ike mmeghari ohuru
Ugbo ikuku na anyanwụ na-eji sistemụ anyị na bọs nchịkọta iji nọgide na-enwe ike ịdị n'otu na ebe njikọ grid. Ị na-enweta obere voltaji site na ikike nkwado, na-ahụ na iwu kwadoro koodu grid.
Olee otú Ọ na-arụ ọrụ
Sistemụ ahụ na-arụ ọrụ site na njikwa ike mmeghachi omume nwere ọgụgụ isi. Mgbe ibu eletriki gị mepụtara ọchịchọ ike mmeghachi omume, ngalaba njikwa na-agbanwe capacitor bank na akpaghị aka n'ịntanetị. Ndị reactors usoro na-egbochi resonance na-emerụ ahụ ma na-ejigide ike kachasị mma.
N'oge ibu dị mfe, sistemụ ahụ na-ewepụ ebe nchekwa capacitor na-adịghị mkpa iji gbochie ịkwụghachi ụgwọ gabigara ókè. Ọrụ akpaka a na-eme ka ị nwee ike ịnọgide na-enwe ike kachasị mma na-enweghị ntinye aka.
Imepụta Ọkachamma
Na Xi'an Xikai Medium And Low Voltage Electric Co., Ltd., anyị na-agbaso ụkpụrụ dị mma siri ike. Usoro mmepụta anyị gụnyere nnwale dielectric zuru oke, nha ikike n'ime -5% ruo +10% ndidi, na nha mwepụ akụkụ n'okpuru 50pC na voltaji 1.1x.
Anyị agafeela usoro njikwa mma ISO9001, usoro njikwa gburugburu ebe obibi ISO14001, na asambodo sistemụ nlekọta ahụike na nchekwa ọrụ OHSAS18001. Ngwaahịa anyị na-emezu ụkpụrụ mba na ihe achọrọ maka ụlọ ọrụ maka voltaji ruru 40.5kV.
Ntak emi Họrọ Anyị
Ị na-arụ ọrụ na ụlọ ọrụ nwere ahụmịhe miri emi na ngwa nkesa ike dị n'etiti na nke dị ala. Anyị na-enye ọrụ njikọta sistemụ zuru oke n'ụdị 9, usoro 34, na ihe karịrị ụdị ngwa eletriki 100.
Ngwaahịa anyị na-arụ ọrụ nke ọma n'ebe dị elu ruo mita 4000 n'elu oke osimiri. Ị na-enweta ihe ngosi teknụzụ nke na-emezu ma ọ bụ gafere ọkọlọtọ mba, nke aha ọma anyị dị ka akara ama ama na China kwadoro.
Anyị na-enye ngwọta sistemụ zuru oke na nkwado ọrụ. Ọrụ gị na-erite uru site na usoro anyị jikọtara ọnụ nke na-ebelata mgbagwoju anya ma na-ahụ na enwere ike ijikọ ya na akụkụ niile.
FAQ
Q: Kedu ka m ga-esi họrọ oke reactor ziri ezi maka ngwa m?
A: Nhọrọ dabere na usoro harmonic kachasị na grid gị. Jiri 6% reactors maka harmonic nke ise, nke asaa, na nke ka elu. Họrọ 12% reactors ma ọ bụrụ na harmonic nke atọ na-adịkarị.
Q: Kedu ngwaọrụ mgbanwe na-arụ ọrụ na setịpụ zuru oke gị?
A: Anyị na-akwado ndị na-akpọsa vacuum ma ọ bụ ndị na-agbaji sekit SF6 nke e nyere ikike maka mgbanwe capacitive. Nke a na-ebelata ohere restrike na oke voltaji dị ize ndụ.
A: Kedu ka sistemụ si ejikwa ọnọdụ ndị na-adịghị mma?
A: Nkwụghachi ụgwọ ike HV anyị zuru oke na-eji nchekwa ọkụ eletrik na-adịghị mma. Ndahie otu ihe na-akpali mkpu ma ọ bụ mee ka ihe mgbawa ahụ ghara ịdị ike iji gbochie mmebi.
Ajụjụ: Kedu ihe ndozi achọrọ?
A: Nnyocha kwa afọ gụnyere ịlele njikọ bọs, ihicha ihe mkpuchi porcelain, ịlele ikuku ikuku reactor, na nnwale maka iguzosi ike n'ezi ihe mkpuchi dị n'ime.
Kpọtụrụ Anyị
Ị dị njikere imeziwanye ike gị site na iji HV Capacitor Complete Set anyị dị elu ? Ndị otu teknụzụ anyị dị njikere ịtụle ihe ị chọrọ ma nye azịza ahaziri iche.
Kpọtụrụ anyị taa na serina@xaxd-electric.com maka nkọwapụta zuru ezu, ọnụahịa, na nkwado teknụzụ. Anyị ga-enyere gị aka ịhọrọ nhazi kachasị mma maka mkpa sistemụ eletriki gị.
ZIPỤ NCHỌPỤTA




