Ọgwụgwọ ogo ike

0
  • nzacha ike na-arụ ọrụ 400V APF modular

    Ihe nzacha ike APF a na-arụ ọrụ nke modular bụ ihe owuwu nke rack-mount maka ndozi ike 400V: modulu 25, 50, 75, 100 na 150A na-ejikọ na stacks ndị yiri ibe ha na-akparaghị ókè ma enwere ike ịdọrọ ma ọ bụ tinye ha ka ibu na-agbanwe. Ihe nlele inverter dabere na IGBT gbagọrọ agbagọ current na njikwa DSP ma na-etinye ụgwọ mgbochi-phase, na-egbochi harmonics nke 2nd-50th na ọnụego mmezi karịrị 92% ebe ha na-ejide PF 0.99. Modulu ike a na-agbanwe ọkụ na N+1 redundancy na-eme ka ụgwọ ọrụ dị ndụ n'oge mmezi, na-eme ka unit ahụ dabara na osisi nwere VFDs, rectifiers na sistemụ UPS.

  • 400V jenereta SVG static var

    Igwe mmepụta SVG static var a bụ modulu ọrụ 400V nke usoro mmezi obere voltaji nke Xi'an Xikai: ụdị nke 10, 15, 30, 50, 75 na 100kvar e wuru maka 400V gbakwunyere ma ọ bụ mwepu 20%, 50/60Hz sistemụ atọ. A na-eji ikuku eme ka ọ dị jụụ ma kwụnye ya n'elu mgbidi, modulu ọ bụla na-arụ ọrụ dị ka nkeji ike nke onwe ya ma ọ bụ dị ka blọk ụlọ nke na-adakọ na-enweghị oke na osisi ndị buru ibu. Ọ na-etinye ọkụ eletrik na-emegharị ahụ n'okpuru 15ms iji jide PF 0.99, na-edozi enweghị nguzozi ibu ma na-adaba n'enweghị nsogbu na oke ọkụ eletrik, oke voltaji/okpuru voltaji ma ọ bụ oke okpomọkụ - ndozi ndọda maka nri 400V yana ịgbado ọkụ, ibuli elu na ibu VFD.

  • Akụrụngwa zuru oke nke SVG Dynamic Reactive Power Compensator

    1.Rated Voltage: 6 ~ 35kV
    2. Ịkwụ ụgwọ ikike: 0.3 ~ 50Mvar
    3.XD-dSvG nwere ụdị ọrụ dịgasị iche iche: ihe na-eme ka ọ dị ugbu a, ike na-arụ ọrụ mgbe niile, voltaji ụgbọ ala mgbe niile, ihe ike mgbe niile, na ọnọdụ ọ bụla nwere ike ịtọ dị ka onye ọrụ chọrọ.
    4.XD-dSVG ọ bụghị naanị na-akwụ ụgwọ maka ikike mmeghachi omume dị mkpa, kamakwa ọ na-egbochi harmonics dị ala ma kwụọ ụgwọ maka enweghị aha.

  • SVG- Static Var Generator

    1. Ntinye ntinye:400V*(1±20%)
    2. Ike Grid ugboro: 50Hz / 60Hz
    Nkwụghachi ụgwọ 3.Bi-Dynamic: Na-ejigide PF 0.99, na-egbochi n'elu / n'okpuru ụgwọ.
    4.Capacity Efficient: 20-30% obere ikike achọrọ karịa SVC
    5.Nzaghachi ngwa ngwa: <15ms zuru nzaghachi, <50μs ike.

  • APF/AHF Ike arụ ọrụ/nyocha kwekọrọ na mgbidi

    1. Ntinye ntinye:400V*(1±20%)
    2. Ike Grid ugboro: 50Hz / 60Hz
    3. Real-time nsuso:
    Na-ejigide ihe ike sistemu na 0.99 site na linear, nkwụghachi ụgwọ bidirectional (capacitive/inductive).
    4. Teknụzụ na-arụ ọrụ:
    Na-egbochi resonance/mgbasa nkwekọ; ịrụ ọrụ nke ọma ọbụna n'okpuru ọnọdụ voltaji dị ala.
    5.Modular imewe:
    A na-etinye mgbidi

  • APF/AHF Ike arụ ọrụ/nyocha kwekọrọ

    1. Ntinye ntinye:400V*(1±20%)
    2. Ike Grid ugboro: 50Hz / 60Hz
    3.Real-time nsuso: Na-ejigide ike usoro na 0.99 site linear, bidirectional (capacitive / inductive) nkwụghachi ụgwọ.
    4.Active technology: Na-egbochi resonance / harmonic amplification; ịrụ ọrụ nke ọma ọbụna n'okpuru ọnọdụ voltaji dị ala.
    5.Modular design: Rack-mounted

6