ngwaahịaPic

Ihe njide ihe nkiri 10KV

1. Ugboro 60Hz.
2. Ikewapụ -5%~+10%.
3. Oke Ugbua 2.5×In.
Ejiri ihe ndị na-eguzogide mwepụta mee ihe 4. Ejikọtara ya na ngwaọrụ nchekwa oke voltaji nọọrọ onwe ha.
5.Arụmọrụ ọgwụgwọ onwe onye dị elu na ndụ ọrụ agbatịkwuru.
6. Ihe na-ebelata mfu, ụdị akọrọ na-enweghị ihe owuwu na-agbapụta mmiri.
7. Ejiri ihe mgbochi mwepụta rụọ ọrụ.
ZIPỤ NCHỌPỤTA
Budata site na ntaneetị
  • Nnyefe ngwa ngwa
  • Quality nkwa
  • 24/7 Ọrụ Ndị Ahịa

Product Okwu Mmalite

Ihe Ngosiputa Ihe Nkiri 10KV - Ngwọta Ike Arụmọrụ Dị Elu

Product Okwu Mmalite

Mgbe ịchọrọ nkesa ike a pụrụ ịtụkwasị obi na volt 10,000, Capacitor ihe nkiri 10KV anyị na-enye arụmọrụ pụrụ iche maka ngwa gị kachasị achọ. Emebere capacitors ndị a maka sistemụ voltaji etiti ebe enweghị ike imebi ntụkwasị obi. Ejiri teknụzụ ihe nkiri polypropylene dị elu rụọ ha, ha na-enye njikwa voltaji ka mma na ogologo oge nke ọrụ gị dabere na ya.

Ihe mkpuchi ihe nkiri anyị nwere ihe mgbochi mwepụ agbakọtara maka nchekwa ka mma. Ha na-abịa na ngwaọrụ nchekwa oke voltaji nọọrọ onwe ha arụnyere n'ime ya. Ị na-enweta arụmọrụ ọgwụgwọ onwe onye ka mma nke na-agbatị ndụ ọrụ nke ukwuu. Nhazi ụdị akọrọ na-ewepụ nsogbu ntapu kpamkpam. Nke kachasị mkpa, ị na-erite uru site na obere ihe mfu nke na-eme ka arụmọrụ sistemụ dịkwuo mma.

Nka na ụzụ nkọwa

oke nkọwapụta
gosiri voltaji 10kV
Frequency 50 / 60Hz
Ngbanwe nke ikike -5% ruo +10%
Oke Ugbu A 2.5 × N'ime
Ihe nchụsa (tan δ) <0.0005 na 1kHz
mkpuchi ihe Nguzogide > 30,000 MΩ
operating okpomọkụ -40 Celsius C ka + 85 Celsius C
Ihe dielectric Ihe nkiri Polypropylene (PP)
Encapsulation Resin epoxy nke na-egbochi ire ọkụ
Ọnọdụ nchekwa UL94 V-0
Njikwa Pulse Ruo 1000V/µs

Isi atụmatụ na uru

Teknụzụ na-agwọ onwe ya

Sistemụ gị na-arụ ọrụ ọbụlagodi mgbe voltaji gbanyere mkpọrọgwụ. Mgbe voltaji karịrị akarị mere, teknụzụ ihe nkiri anyị e ji ígwè rụọ na-ewepụ ntụpọ na akpaghị aka ma weghachite ọrụ.

Ihe Mfu Dị Ala nke Ukwuu

Ị na-echekwa ego ike site na obere mmepụta okpomọkụ n'oge ọrụ. Nhazi polypropylene dị elu na-enye arụmọrụ kachasị elu n'ime ụlọ ọrụ.

Nnukwu Ihe Mwube

E wuru ya ka ọ ghara iguzogide gburugburu ụlọ ọrụ siri ike. E tinyere ihe mkpuchi epoxy nke na-egbochi ire ọkụ na-echebe megide iru mmiri ma na-egbochi nkụchi dị ize ndụ.

Ike Pulse Dị Elu

Jiri obi ike jikwaa mgbanwe voltaji ngwa ngwa. Mmezi ígwè dị arọ na-eguzogide mgbanwe transients nke ga-emebi capacitors nkịtị.

Ngwa Ngwa

Sistemụ Nkesa Ike

Ị ga-ahụ na capacitors anyị dị oke elu dị mkpa na ebe nchekwa mgbanwe voltaji etiti na nke ike. Ha na-enyere aka ịnọgide na-enwe nkwụsi ike na grid ma belata ntaramahụhụ ike mmeghachi omume.

Ngwá ọrụ mmepụta ihe

Zuru oke maka draịva moto, akụrụngwa ịgbado ọkụ, na igwe dị arọ ebe arụmọrụ Capacitor 10KV a pụrụ ịtụkwasị obi dị oke mkpa maka ọrụ na-aga n'ihu.

Ngwa ahụike na sayensị

Tụkwasị capacitors anyị obi na igwe X-ray, CT scanner, na ngwa ụlọ nyocha ebe nkenke na nchekwa dị oke mkpa.

Sistemụ ume ọhụrụ

Kwado turbines ikuku na inverters anyanwụ site na ịkwụghachi ụgwọ ike na-agbanwe agbanwe na nhazi voltaji.

Olee otú Ọ na-arụ ọrụ

Ihe mkpuchi ihe nkiri 10KV na-arụ ọrụ site na ụkpụrụ dielectric dị elu. Ọtụtụ oyi akwa ihe nkiri polypropylene na-emepụta ihe mgbochi voltaji siri ike. Mgbe nrụgide eletriki mere, mkpuchi metal na-ekesa voltaji n'otu aka ahụ n'ofe dielectric.

Usoro ọgwụgwọ onwe ya na-arụ ọrụ n'oge ihe mberede nke oke voltaji. Mmegharị gburugburu ebe nsogbu na-ekupụ ozugbo. Nke a na-ekewapụ ebe mebiri emebi ma na-ejigide ọrụ capacitor. Sistemụ gị na-aga n'ihu na-arụ ọrụ na-enweghị nkwụsị.

Imepụta Ọkachamma

Ebe mmepụta anyị na-agbaso ụkpụrụ dị mma siri ike. A na-anwale capacitor ọ bụla nke ọma tupu ebuga ya. Anyị na-eji naanị fim polypropylene dị elu nke sitere n'aka ndị na-ebubata ngwaahịa asambodo.

Njikwa ịdị mma gụnyere nnwale voltaji dị elu, ịgbagharị okpomọkụ, na nkwenye ndụ ogologo oge. Sistemụ njikwa ịdị mma ISO9001 anyị na-ahụ na arụmọrụ na-aga n'ihu. Njikwa gburugburu ebe obibi site na asambodo ISO14001 na-echebe ụwa anyị.

Onye ọ bụla nwere ike itinye ihe nkiri 10KV na-emezu ụkpụrụ mba ụwa dịka IEC 60871 na IEC 61071. Nrubeisi a na-ekwe nkwa oke nchekwa megide oke voltaji oge ụfọdụ.

Ntak emi Họrọ Anyị

Ahụmahụ egosipụtara

Xi'an Xikai nwere ahụmịhe ọtụtụ iri afọ na akụrụngwa voltaji dị ala na nke ọkara. Ngwaahịa anyị na-ejere ndị ahịa ozi n'ofe mmepụta ike, akpaaka ụlọ ọrụ mmepụta ihe, na ọrụ akụrụngwa.

Oke ngwaahịa zuru oke

Anyị na-enye ngwọta nkesa ike zuru oke. Site na switchgear dị elu ruo na transformers, ụzọ anyị jikọtara ọnụ na-eme ka usoro ịzụrụ ihe gị dị mfe.

Nkwado ndị teknuzu

Ndị otu injinia anyị na-enye ndụmọdụ ọkachamara n'oge ọrụ gị niile. Anyị na-enyere aka ime ka nhọrọ capacitor dị mma maka ihe ịchọrọ maka ngwa gị.

Mmekọrịta Kwesịrị Ntụkwasị Obi

Họrọ onye nrụpụta nke raara onwe ya nye na mmekọrịta ogologo oge. Anyị na-enye nkwado teknụzụ na-aga n'ihu na nnweta akụkụ ma ọ bụ ihe ndị ọzọ ruo ọtụtụ afọ na-abịa.

FAQ

Q: Gịnị na-eme ka capacitors fim ka mma karịa ụdị seramiiki maka ngwa 10kV?

A: Ihe mkpuchi ihe nkiri na-ewepụ mkpọtụ piezoelectric na nsogbu mgbawa a na-ahụkarị n'ụdị seramiiki. Ha na-enyekwa njikwa pulse dị mma na ikike ịgwọ onwe onye.

Q: Ogologo oge ole ka capacitors ndị a na-adịrukarị?

A: Site na nrụnye na ọnọdụ ọrụ kwesịrị ekwesị, ihe mkpuchi ihe nkiri anyị na-enye ọrụ ọrụ a pụrụ ịtụkwasị obi ruo afọ 20+.

Q: Ndị a nwere ike ijikwa nrụnye dị n'èzí?

A: Ee, ihe mkpuchi epoxy nke na-egbochi ire ọkụ na-echebe megide iru mmiri, oke okpomọkụ, na ikpughe UV n'èzí.

Q: Kedu nhọrọ mgbochi mwepụ dị?

A: Anyị na-enye ndị na-eguzogide mwepụ agbakọtara nke a tụrụ aro maka mbelata voltaji dị mma n'ime otu nkeji mgbe ewepụsịrị ike, na-emezu ụkpụrụ nchekwa.

Q: Ị na-enye ụkpụrụ ikike pụrụ iche?

A: N'ezie. Anyị na-emepụta nhazi omenala iji mezuo ihe achọrọ maka voltaji, ikike, na nrụnye.

Kpọtụrụ Anyị

Ị dị njikere ime ka ntụkwasị obi sistemụ ike gị ka mma? Ndị ọkachamara teknụzụ anyị nọ ebe a iji nyere gị aka ịhọrọ ngwọta Capacitor 10KV zuru oke maka ngwa gị.

Kpọtụrụ ndị otu anyị taa maka nkọwapụta zuru ezu, nhazi omenala, ma ọ bụ ndụmọdụ teknụzụ. Anyị na-agba mbọ inye gị akụkụ nkesa ike kachasị mma nke nkwado ọkachamara kwadoro.

Email: serina@xaxd-electric.com

Ka anyị nyere gị aka inweta arụmọrụ sistemụ ike dị elu site na iji teknụzụ anyị dị elu nke na-enye gị ohere inweta ihe ịga nke ọma. Ihe ịga nke ọma gị bụ ihe kacha anyị mkpa.

Send