Msonkhano Wopereka Malipilo a Mphamvu Yogwira Ntchito Wanzeru
Chipangizo Cholipirira Mphamvu Yogwira Ntchito ya 10kV
2. Kuthamanga kwa mafunde: 50Hz.
3. Mphamvu: 100–10,000kVar.
4.Kutentha kwapakati: -25 ℃ ~ + 45 ℃;
5. Zosankha za reaktarakitala:.
Kuletsa kuthamangira kwa mpweya: 0.1–1% reactance.
Kuletsa kwa 5+ harmonic: 6% reactance.
Kuletsa kwachitatu kwa harmonic: 12% reactance.
- Kutumiza Mwachangu
- Quality Chitsimikizo
- 24/7 Makasitomala
mankhwala Introduction
Chipangizo Cholipirira Mphamvu Yogwira Ntchito ya 10kV
mankhwala Introduction
Chipangizo chathu cha 10kV High Voltage Reactive Power Compensation Device ndi njira yamagetsi yapamwamba yapakati-voltage yopangidwira kukonza bwino mphamvu zamagetsi m'maukonde ogawa mafakitale. Zipangizo zamakonozi zimayendetsa bwino mphamvu yosinthira yopangidwa ndi zinthu zolemera zamafakitale monga ma mota, ma transformer, ndi ma arc furnaces ndi mphamvu yeniyeni yosinthira yosinthika. Mwa kusunga mphamvu yabwino kwambiri kuposa 0.95, mutha kuchotsa zilango zokwera mtengo zamagetsi pomwe mukukweza kwambiri magwiridwe antchito amagetsi anu.
Chipangizochi chimabwera m'makonzedwe osiyanasiyana kuphatikizapo Automatic Capacitor Banks (TBB), Static Var Generators (SVG), ndi Magnetic Controlled Reactors (MCR). Mtundu uliwonse umalimbana ndi mavuto enaake a mafakitale kuyambira kusinthasintha kwa katundu mwachangu mpaka kusokonekera kwa harmonic. Malo anu adzapindula ndi kukhazikika kwa magetsi, kuchepa kwa kutayika kwa mzere, komanso kugwiritsa ntchito mphamvu zambiri za transformer.
luso zofunika
| chizindikiro | mfundo |
|---|---|
| Adavotera Voltage | 6-10kV (Masimidwe apamwamba a dongosolo 12kV) |
| pafupipafupi | 50Hz |
| Mphamvu ya Malipiro | 100-10,000kVar (Ingakulitsidwe kudzera mu ma module ofanana) |
| Kutentha Kwambiri | -25 ℃ mpaka 45 ℃ |
| Nthawi Yoyankha | <10ms (SVG) / mphindi 1-3 (TBB) |
| Njira Zowongolera | Kuwongolera mphamvu, Kuwongolera magetsi, Kuwongolera mphamvu yogwira ntchito |
| Mtsinje wa Chitetezo | IP54/IP55 (Chosankha chakunja chotchingira) |
| Mulingo Wokwera | Kufikira 4000m pamwamba pa nyanja |
| Communication | RS485/Modbus yolumikizira SCADA |
| Kutulutsa Nthawi | Mphamvu yotsala <50V mkati mwa mphindi 5 |
Zosankha za Reactor
| Type | Zochita | Gusaba Akazi Gashya |
|---|---|---|
| Kuletsa Kuthamanga | 0.1-1% | Chitetezo choyambira motere |
| Kuletsa kwa Harmonic kwachisanu | 6% | Standard mafakitale chilengedwe |
| Kuletsa kwa Harmonic kwachitatu | 12% | Kusokonezeka kwakukulu kwa harmonic |
Main Features ndi Ubwino
Smart Control Technology
Olamulira athu opangidwa ndi microprocessor amapereka kuwunika nthawi yeniyeni komanso kusintha kokha. Mumalandira mphamvu yeniyeni yowongolera pogwiritsa ntchito kuphatikiza kwa SCADA kopanda vuto kuti muwone bwino makina onse.
MwaukadauloZida Safety Features
Chipangizochi chili ndi ma coil otulutsa mpweya mwachangu komanso njira zisanu zotsekera. Zinthuzi zimaonetsetsa kuti antchito anu ali otetezeka panthawi yokonza komanso kukwaniritsa miyezo yapamwamba kwambiri yachitetezo cha mafakitale.
Ntchito Yolimba
Yomangidwa ndi zipangizo zotetezera kutentha zapamwamba zoyenera malo oipitsidwa a kalasi IV. Ndalama zomwe mwayikamo zikutetezedwa ku mikhalidwe yovuta yamafakitale kuphatikizapo fumbi, chinyezi, ndi kusintha kwa kutentha.
Kusintha Kusintha
Kapangidwe ka modular kamalola kukula kwa mphamvu mosavuta. Mutha kuyamba ndi mayunitsi ang'onoang'ono ndikukulitsa pamene malo anu akukula popanda kusintha makina onse.
Mapulogalamu Othandiza
Makampani Olemera ndi Opanga Zitsulo
Mu ntchito zamagetsi, chipangizo chathu cha 10kV High Voltage Reactive Power Compensation Device chimapereka mphamvu yosinthika mkati mwa ma milliseconds. Izi zimaletsa kugwedezeka kwa magetsi komanso zimasunga kukhazikika kwa gridi panthawi yosinthasintha kwa katundu.
Ntchito Zogulitsa Mabomba
Malo opangira migodi okhala ndi mawaya ataliatali komanso magalimoto olemera amapindula ndi mphamvu yamagetsi yofunikira. Kapangidwe kake kolimba kamapirira zovuta kwambiri komanso kumasunga magwiridwe antchito odalirika.
Kupanga Zomera
Makampani akuluakulu opanga zinthu amagwiritsa ntchito zipangizo zathu kuti azitha kugwiritsa ntchito bwino mphamvu zamagetsi komanso kupewa zilango za magetsi. Zotsatira zake n’zakuti zinthu siziwononga ndalama zambiri komanso zimapangitsa kuti ntchito yokonza zinthu izi ikhale yabwino.
Renewable Energy Integration
Mafamu a mphepo ndi dzuwa amadalira zipangizo zathu zolipirira kuti akwaniritse malamulo a Low Voltage Ride Through. Izi zimatsimikizira kulumikizana kosalekeza kwa gridi ngakhale pakagwa vuto la kanthawi kochepa.
Mmene Ntchito
Dongosololi limayang'anira nthawi zonse momwe magetsi amagwiritsidwira ntchito pogwiritsa ntchito ma transformer amagetsi ndi ma voltage. Pamene zinthu zoyendetsera magetsi zimapanga mphamvu yotsalira, dongosolo lowongolera limasintha ma capacitor banks kapena kusintha SVG output.
Pakusintha kwachangu kwa katundu, SVG yochokera ku IGBT imayankha mkati mwa ma millisecond 10. Izi zimaletsa kusinthasintha kwa magetsi komwe kungasokoneze zida zomvera. Ma reactor olumikizirana omwe amalumikizidwa amaletsa kumveka bwino kwa harmonic pamene akusunga mphamvu yobwezera.
Wowongolera wanzeru amaphunzira momwe katundu wa chipangizo chanu amagwirira ntchito komanso kukonza ma switching sequences. Izi zimachepetsa kuwonongeka kwa ma contactor ndipo zimawonjezera nthawi ya zida pamene zikusunga mphamvu zabwino kwambiri.
Kupanga Kwambiri
Xi'an Xidian Medium and Low Voltage Electric Co., Ltd. yabweretsa ukadaulo wazaka zambiri pakupanga zida zogawa magetsi. Kampani yathu yapamwamba kwambiri imapanga zida zomwe zikukwaniritsa miyezo yapadziko lonse lapansi kuphatikiza IEC 60871 ndi IEC 62927.
Chipinda chilichonse chimayesedwa mokwanira kuphatikizapo kutsimikizira mphamvu ya dielectric, kuyeza pang'ono kutulutsa, komanso kutsimikizira kukwera kwa kutentha. Dongosolo lathu loyang'anira khalidwe limatsimikizira magwiridwe antchito okhazikika komanso kudalirika kwa nthawi yayitali.
Timasunga malamulo okhwima okhudza khalidwe pa nthawi yonse yopanga zinthu. Kuyambira kusankha zigawo mpaka kuyesa komaliza, sitepe iliyonse imatsatira njira zovuta zoperekera zida zomwe zimaposa miyezo ya makampani.
Chifukwa Sankhani Us
Mbiri Yotsimikiziridwa
Monga opanga otsogola omwe ali ndi ziphaso za ISO9001, ISO14001, ndi OHSAS18001, timapereka mayankho odalirika pa ntchito zofunika kwambiri. Zogulitsa zathu zimagwira ntchito bwino m'malo osiyanasiyana padziko lonse lapansi.
Thandizo Lonse
Gulu lathu laukadaulo limapereka chithandizo chathunthu kuyambira pakupanga makina mpaka kuyambitsa ntchito. Mumalandira zikalata zatsatanetsatane, maphunziro, ndi thandizo laukadaulo lopitilira kuti muwonjezere ndalama zomwe mumayika.
Sintha mwamakonda
Tikumvetsa kuti malo aliwonse ali ndi zofunikira zapadera. Gulu lathu la mainjiniya limagwira ntchito nanu popanga njira zomwe zikugwirizana ndi zosowa zanu komanso momwe mumagwirira ntchito.
Netiweki ya Utumiki Wakomweko
Ndi mgwirizano wokhazikika wautumiki, timapereka chithandizo chaukadaulo mwachangu komanso kupezeka kwa zida zina. Ntchito zanu zimakhala zotetezeka komanso chiopsezo chochepa cha nthawi yogwira ntchito.
FAQ
Q: Kodi pali kusiyana kotani pakati pa SVG ndi ma capacitor bank achikhalidwe?
A: SVG imapereka chipukuta misozi chosasintha, nthawi yeniyeni mkati mwa 10ms ndipo imagwira ntchito ndi zinthu zamagetsi zotsogola komanso zotsalira. Mabanki achikhalidwe a capacitor amapereka chipukuta misozi pang'onopang'ono koma ndi otchipa kwambiri pa katundu wokhazikika.
Q: Kodi ndingasankhe bwanji kuchuluka kolondola kwa reactor yochotsera mphamvu?
A: Gwiritsani ntchito ma reactor a 6-7% kuti mugwiritse ntchito ma harmonic achisanu m'mafakitale wamba. Sankhani ma reactor a 12-14% pamene ma harmonics achitatu ali ofunika. Kusankha bwino kumateteza ku kugwedezeka koopsa.
Q: Kodi chipangizochi chingagwire ntchito m'malo osungira zinthu panja?
A: Inde, ndi malo oyenera otetezedwa ndi IP55 komanso njira zowongolera nyengo. Magawo okhazikika amapangidwira kuti aikidwe mkati ndi chitetezo cha IP4X.
Q: Kodi nthawi yokonzekera yomwe ikuyembekezeka ndi yotani?
A: Kuwunika mphamvu yamagetsi pachaka kumalimbikitsidwa. Ma capacitor apamwamba kwambiri nthawi zambiri amakhala zaka 8-10 kutengera momwe zinthu zilili komanso kuchuluka kwa ma harmonic.
Q: Kodi izi zingawongolere bwanji mphamvu yanga ya transformer?
A: Kukweza mphamvu kuchokera pa 0.7 mpaka 0.95 kungachepetse kudzaza kwa transformer kVA ndi 20-30%, zomwe zimapangitsa kuti pakhale mphamvu yowonjezera ya zida zina.
Lumikizanani nafe
Kodi mwakonzeka kukonza mphamvu ya chipangizo chanu pogwiritsa ntchito chipangizo chathu cha 10kV High Voltage Reactive Power Compensation ? Akatswiri athu aukadaulo akuyembekezera kukuthandizani kusankha yankho labwino kwambiri lomwe likugwirizana ndi zosowa zanu.
Lumikizanani ndi gulu lathu lero kuti mudziwe zambiri zokhudza ukadaulo, mitengo yokonzedwa, ndi chithandizo chaukadaulo wa mapulogalamu. Tadzipereka kukuthandizani kuti mugwire bwino ntchito yamagetsi pomwe tikuchepetsa ndalama zogwirira ntchito.
Imelo: serina@xaxd-electric.com
Tiloleni tikuthandizeni kusintha momwe magetsi anu amagwirira ntchito komanso kuthetsa mavuto okwera mtengo amagetsi pogwiritsa ntchito ukadaulo wathu wodziwika bwino wolipirira.
tumizani kudziwitsa


