productPic

Dongosolo Lolipirira Mphamvu Yogwira Ntchito la 10kV Substation

1. Voliyumu yoyesedwa: 6–10kV.
2. Kuthamanga kwa mafunde: 50Hz.
3. Mphamvu: 100–10,000kVar.
4.Kutentha kwapakati: -25 ℃ ~ + 45 ℃;
5. Zosankha za reaktarakitala:.
Kuletsa kuthamangira kwa mpweya: 0.1–1% reactance.
Kuletsa kwa 5+ harmonic: 6% reactance.
Kuletsa kwachitatu kwa harmonic: 12% reactance.
  • Kutumiza Mwachangu
  • Quality Chitsimikizo
  • 24/7 Makasitomala

mankhwala Introduction

Dongosolo Lolipirira Mphamvu Yogwira Ntchito la 10kV Substation

mankhwala Introduction

Dongosolo lathu la 10kV Substation Reactive Power Compensation System likuyimira ukadaulo wapamwamba kwambiri pakukonza mphamvu zamagetsi apakatikati. Dongosolo lapamwamba ili limalumikizana bwino ndi malo anu osinthira mafakitale kuti liwongolere mphamvu zamagetsi ndikuchepetsa ndalama zogwirira ntchito. Lopangidwa kuti likhale lodalirika komanso logwira ntchito bwino, dongosolo lathu lobwezera lili ndi mabanki a capacitor amphamvu kwambiri, owongolera anzeru, ndi machitidwe olimba oteteza. Mudzawona kusintha mwachangu pakugwira ntchito kwa mphamvu zamagetsi komanso kuchepetsedwa kwakukulu kwa ndalama zolipirira ntchito. Dongosololi limapereka phindu lapadera kwambiri pazinthu zopangira, mafakitale opanga mankhwala, ndi malo akuluakulu ogulitsa omwe amafunikira kugawa mphamvu kokhazikika.

luso zofunika

chizindikiro mfundo
Adavotera Voltage 6-10 kV
Nthawi Yogwira Ntchito 50Hz
Mphamvu ya Malipiro 100-10,000 kVar
Kutentha Kwambiri -25 ℃ mpaka 45 ℃
Power Factor Correction 0.7 mpaka 0.95+
Nthawi Yoyankha <masekondi atatu (mtundu wa contactor)
Kuteteza Mulingo IP3X/IP4X
Insulation Level 75kV BIL
Zosankha za Reactor 0.1%, 6%, 12% reaction
Kuwongolera Kulondola ± 1% ya mphamvu yovomerezeka

Main Features ndi Ubwino

Dongosolo Lowongolera Mwanzeru : Chowongolera chathu chapamwamba cha microprocessor chimayang'anira chokha mphamvu yanu ndikusintha magawo obwezera ngati pakufunika. Mumapindula ndi kasamalidwe ka mphamvu kolondola popanda kuchitapo kanthu pamanja.

Kusefa kwa Harmonic : Ma reactor omangidwa mkati amaletsa kumveka koipa akamasefa ma harmonic. Zipangizo zanu zamagetsi zimagwira ntchito bwino kwambiri popanda kupsinjika kwambiri komanso nthawi yayitali.

Ukadaulo Woyankha Mwachangu : Dongosololi limayankha mwachangu kusintha kwa katundu, ndikusunga mphamvu yoyenera panthawi yogwira ntchito. Mudzawona magwiridwe antchito okhazikika ngakhale mutasintha katundu wamafakitale.

Chitetezo Chokwanira : Zinthu zambiri zotetezera kuphatikizapo chitetezo chamagetsi ochulukirapo, chitetezo chamagetsi ocheperako, ndi chitetezo chamagetsi chosakwanira zimatsimikizira kuti ntchito yanu ikuyenda bwino. Ndalama zomwe mwayika zimakhala zotetezeka ku zovuta zamagetsi.

Kapangidwe ka Modular : Kapangidwe kowonjezereka kamalola kuwonjezera mphamvu mosavuta pamene malo anu akukula. Mutha kukulitsa makinawo popanda kusintha kwakukulu kwa zomangamanga.

Mapulogalamu Othandiza

Zipangizo Zazikulu Zamakampani : Mafakitale achitsulo ndi mafakitale achitsulo okhala ndi ng'anjo ya arc amapindula kwambiri ndi kukhazikika kwa magetsi ndi kuchepetsa kuyaka. Dongosolo Lothandizira Mphamvu Yogwira Ntchito la 10kV Substation limagwira ntchito bwino posintha zinthu mwachangu.

Malo Opangira Mankhwala : Malo okhala ndi ma mota othamanga kwambiri komanso zida zogwirira ntchito amawona magwiridwe antchito abwino komanso kuchepa kwa harmonic distortion. Ubwino wa kupanga kwanu umawonjezeka pomwe mtengo wamagetsi umachepa.

Malo Opangira Mafakitale Akuluakulu : Malo opangira zinthu ndi malo opangira zinthu amakhala ndi mphamvu yokhazikika komanso amachotsa zilango zamagetsi. Mumapeza magwiridwe antchito abwino komanso ndalama zochepa zogwirira ntchito.

Malo Osungira Mphamvu Zobwezerezedwanso : Malo osonkhanitsira magetsi a mphepo ndi dzuwa amafunika thandizo la mphamvu zobwezera mphamvu panthawi yochepa yopanga magetsi. Dongosolo lathu limaonetsetsa kuti magetsi akutsatira malamulo a gridi komanso kulumikizana kokhazikika.

Mmene Ntchito

Dongosololi limayang'anira nthawi zonse kufunikira kwa mphamvu yogwira ntchito ya malo anu kudzera mu ma transformer amagetsi olondola komanso amagetsi. Pamene katundu woyambitsa zinthu apanga mphamvu yotsalira, chowongolera chanzeru chimasintha chokha ma capacitor banks pa intaneti.

Ma reactor otsatizana amateteza ma capacitor ku mafunde olowa ndipo amaletsa kumveka bwino kwa harmonic. Wowongolera amawerengera njira zabwino kwambiri zosinthira kuti asunge mphamvu yanu yowunikira pomwe akupewa kubweza ndalama zambiri.

Munthawi ya kunyamula katundu wopepuka, makinawa amachotsa okha magawo a capacitor kuti apewe mphamvu yotsogola. Yankho lamphamvuli limatsimikizira magwiridwe antchito abwino kwambiri pazochitika zonse zogwirira ntchito.

Kupanga Kwambiri

Ku Xi'an Xikai Medium And Low Voltage Electric Co., Ltd., timasunga miyezo yokhwima yaubwino nthawi yonse yopanga. Malo athu opangira zinthu ali ndi zida zoyesera zapamwamba kuti zitsimikizire mphamvu ya dielectric komanso kutsimikizira magwiridwe antchito a kutentha.

Dongosolo lililonse la 10kV Substation Reactive Power Compensation System limayesedwa bwino kwambiri kuti livomerezedwe ndi fakitale. Timatsimikiza kulondola kwa capacitance, umphumphu wa insulation, komanso magwiridwe antchito a chitetezo cha makina musanatumize.

Makina athu oyendetsera bwino zinthu amakwaniritsa miyezo ya ISO9001, kuonetsetsa kuti zinthu zikuyenda bwino nthawi zonse. Mumalandira zida zomwe zimakwaniritsa miyezo yapadziko lonse lapansi komanso zomwe zimapereka zaka zambiri zogwirira ntchito yodalirika.

Chifukwa Sankhani Us

Chidziwitso Chotsimikizika : Ndi luso lalikulu pa zida zamagetsi apakati ndi otsika, timamvetsetsa mavuto anu amagetsi. Gulu lathu la mainjiniya limapanga mayankho ogwirizana ndi zosowa zanu.

Mitundu Yonse ya Zinthu : Kuyambira makina a 0.4kV mpaka 40.5kV, timapereka njira zonse zogawira mphamvu. Mumagwira ntchito ndi wogulitsa mmodzi pazosowa zanu zonse zamagetsi.

Thandizo la Ukadaulo : Mainjiniya athu odziwa bwino ntchito amapereka chithandizo nthawi zonse pa moyo wonse wa makina anu. Mumalandira thandizo la akatswiri pakukhazikitsa, kuyambitsa, ndi kukonza.

Mtengo Wampikisano : Timapereka zida zapamwamba kwambiri pamitengo yopikisana komanso ntchito yabwino kwambiri yogulitsa pambuyo pogulitsa. Ndalama zomwe mwayika zimapereka phindu lalikulu kudzera mukuchita bwino komanso kudalirika.

FAQ

Q: Kodi ndingadziwe bwanji mphamvu yobwezera yomwe ikufunika?

A: Timachita kusanthula mwatsatanetsatane kuchuluka kwa mphamvu zomwe zimagwiritsidwa ntchito pa malo anu ogwirira ntchito komanso mphamvu zomwe zilipo kuti tipereke malingaliro okhudza mphamvu zomwe zilipo.

Q: Kodi dongosololi lingathe kuthana ndi malo okhala ndi zinthu zambiri zofanana?

A: Inde, ma reactor athu adapangidwa makamaka kuti apewe kusinthasintha kwa ma resonance ndi ma filter harmonics omwe amagwiritsidwa ntchito m'mafakitale.

Q: Ndi kukonza kotani komwe kumafunikira?

A: Kuyang'anira pafupipafupi ma contactor, kuyang'anira momwe capacitor ilili, komanso kuyesa makina oteteza chaka chilichonse kumatsimikizira kuti zinthu zikuyenda bwino.

Q: Kodi kukhazikitsa nthawi zambiri kumatenga nthawi yayitali bwanji?

A: Kukhazikitsa kwachizolowezi kumatha mkati mwa masiku 3-5, kutengera zovuta za makina ndi momwe malo alili.

Lumikizanani nafe

Kodi mwakonzeka kusintha mphamvu yanu ndikuchepetsa ndalama zamagetsi? Akatswiri athu aukadaulo ali pano kuti akuthandizeni kusankha njira yabwino kwambiri yolipirira magetsi ya 10kV Substation Reactive Power Compensation System pa malo anu.

Lumikizanani ndi gulu lathu logulitsa lero kuti mudziwe zambiri zokhudza luso lanu komanso mitengo yopikisana. Tigwira nanu ntchito kuti tipange yankho lomwe likukwaniritsa zosowa zanu komanso bajeti yanu.

Imelo : serina@xaxd-electric.com

Tiloleni tikuthandizeni kupeza mphamvu zabwino kwambiri komanso magwiridwe antchito abwino pogwiritsa ntchito ukadaulo wathu wotsimikizika wolipirira.

kutumiza