400V Inozvirapa Capacitor-cylindrical
2. Kakawanda:50/60Hz.
3. Dhizaini diki, yakashongedzerwa nebhaudhi rekudzika.
4. Zvinhu zvekushandisa muhari: PU resin (soft resin).
5.Kuisa uye kuisa waya zviri nyore.
6.Saizi diki, Huremu hwakareruka.
7. Kuzvirapa, Kuchengetedza-kusina.
- Fast Delivery
- Quality Panga
- 24/7 Vatengi Sevhisi
Product Introduction
400V Inozvirapa Capacitor-Cylindrical | Simba Remhando Yemagetsi Mhinduro
Product Introduction
Kana sisitimu yako yemagetsi ichida muripo wesimba remagetsi unovimbika, 400V Self-healing Capacitor-cylindrical yedu inoita basa rakanaka. Iyi capacitor yepamusoro ine tekinoroji ye polypropylene film dielectric yakagadzirwa nesimbi, yakagadzirirwa kushandiswa kwemagetsi mashoma. Iwe uchabatsirwa nedhizaini yedu ye cylindrical compact iyo inochengetedza nzvimbo yekuisa uku ichipa simba rakasimba rekugadzirisa zvinhu. Imwe neimwe ye400V Self-healing Capacitor-cylindrical unit inosanganisira dziviriro yakabatana yekuchengetedza uye mashandiro ega ega, ichivimbisa kushanda pasina kunetseka munzvimbo dzemaindasitiri nedzemabhizinesi. Isu tinogadzira ma capacitor aya tichitevera mitemo yenyika uye nhungamiro dzeIEC, tichikupa chivimbo mune yega yega kuiswa.
Ma capacitor edu e cylindrical anomiririra makore ehunyanzvi hweinjiniya yemagetsi. Akagadzirwa kuti agadzirise mamiriro ezvinhu akaomarara uku achiramba achishanda zvakanaka. Uchaona kuti akakodzera masisitimu ekuparadzira magetsi, madhiraivha emota, uye mashandisirwo ekugadzirisa magetsi.
Technical Magadzirirwo
| Parameter | Specification |
|---|---|
| Rated Voltage | 400V AC (250V~525V inowanikwa, kusvika ku2000V) |
| maitikiro | 50 / 60Hz |
| Capacitance Range | Custom configurations iripo |
| Insulation Level | 3kV |
| Dielectric Kurasikirwa | <0.0010 (20℃, 50Hz) |
| uchishandisa Temperature | -20 ° C kusvika + 50 ° C |
| Altitude | Kusvika 2000m (mhando dzakakwirira kusvika 4000m) |
| encapsulation | PU resin (soft resin) - yakaputirwa muhari ine vacuum cleaner |
| Housing | Goko rearuminiyamu rakaumbwa nesimbi |
| Chinodzivirira kubuda kwesimba | Yakabatana zvachose (voltage inodonha pasi pe75V mukati memaminitsi matatu) |
| Maitiro ekuteerera | GB/T 12747.1&2-2004, IEC60831-1/2 |
Main Features uye Zvakanakira
Tekinoroji Yekuzvirapa Yepamusoro
Sisitimu yako inoramba yakachengetedzwa nekuda kwefirimu redu repamusoro-soro rinozviporesa. Kana paine kukuvara kudiki, capacitor inozvigadzirisa yoga pasina kukanganisa. Izvi zvinowedzera hupenyu hwebasa zvakanyanya.
Dhizaini Yakatetepa yeSilindrical
Uchafarira magadzirirwo e cylindrical anochengetedza nzvimbo. Yakareruka kupfuura ma capacitor echinyakare emhando yebhokisi uye iri nyore kuisa munzvimbo dzakamanikana. Bhaudhi repasi rinoita kuti kuiswa kwacho kuve kwakachengeteka uye kuri nyore.
Dziviriro Yekuchengetedza Katatu
Takabatana nekudzivirira mukati medu kubva pakupisa kwakanyanya, kumanikidzwa kwakanyanya, uye mamiriro ekunze akawandisa. Chinhu chimwe nechimwe chinobviswa zvakachengeteka kana chasvika pakuguma kwehupenyu, zvichidzivirira sisitimu yako yese.
Low Kurasikirwa Kwekuita
Mari yako yesimba inoramba iri shoma nekuda kwedhizaini yedu yekurasikirwa nemagetsi yakaderera zvikuru. Kupisa kunogadziriswa kuburikidza nekuisa resin inofambisa kupisa.
Kugadzirisa-Kushanda Kwemahara
Kana yangoiswa, unogona kukanganwa nezvazvo. Hapana oiri, hapana kudonhedza mvura, hapana kugadziriswa nguva nenguva kunodiwa. Kungogadzirisa simba nguva dzose uye kwakavimbika.
Applications Applications
Uchaona kuti ma capacitor edu ari kushanda zvakanaka mu:
- Industrial Manufacturing Plants - Kubhadhara simba remagetsi rinobva kumamota nematransformer
- Zvivako zvekutengesa - Kuvandudza hunhu hwemagetsi muHVAC uye masisitimu emwenje
- Power Distribution Networks - Kuderedza kurasikirwa kwemutsetse uye kudonha kwemagetsi
- Renewable Energy Systems - Kugadzirisa simba rinobuda kubva mumagetsi ezuva nemhepo
- Data Centers - Kuve nechokwadi chekuti magetsi anowanikwa akachena uye anoshanda zvakanaka kumidziyo yakakosha
- Mining Mashandiro - Kugadzirisa nharaunda dzakaoma uye mitoro yemagetsi inorema
Ainoita
400V Self-healing Capacitor-cylindrical yako inoshanda nekuchengetedza simba remagetsi mu polypropylene film dielectric yayo yesimbi. Kana yakabatana pamwe chete ne inductive loads, inopa simba re reactive munharaunda, zvichideredza reactive current inoyerera kuburikidza ne distribution system yako.
Nzira yekuzviporesa inoshanda seizvi: kana paine nzvimbo isina simba mu dielectric, arc diki inonyungudutsa simbi yakakomberedza nzvimbo yekutadza. Izvi zvinobvisa dambudziko mukati memamiliseconds, uye capacitor inoramba ichishanda nesimba rakaderera zvishoma. Haumbofi wakangoerekana wakundikana.
Kuvharwa kwePU resin inonyudzwa ne vacuum kunobvisa mhepo inobuda uye hunyoro, zvichiita kuti simba re dielectric riwedzere. Kupisa kunobva panguva yekushanda kunopfuudzwa zvakanaka kuburikidza ne resin kuenda ku aluminium shell, zvichiita kuti tembiricha ishande zvakanaka.
Kugadzira Kunaka
KuXi'an Xidian Medium and Low Voltage Electrical Co., Ltd., tinounza makumi emakore ehunyanzvi hwemidziyo yemagetsi kune ese ma capacitor atinogadzira. Nzvimbo yedu yekugadzira inoshandisa michina yekumonera nemazvo uye tekinoroji yekugadzirisa vacuum kuti ive nechokwadi chekuti mhando yacho inogara yakafanana.
Takashandisa masisitimu akakwana ekutarisira mhando anosanganisira ISO9001, ISO14001, uye OHSAS18001 certifications. Capacitor yega yega inoedzwa zvakasimba isati yabuda mufekitori yedu - kusanganisira bvunzo dze voltage standing, capacitance accuracy test, uye discharge resistance validation.
Chikwata chedu chekutsvagisa nekugadzira chinoramba chichivandudza magadzirirwo zvichibva pane zvataurwa nevanhu chaivo. Sevatori vechikamu mumapurojekiti etekinoroji yenyika, tinobatanidza zvinhu zvitsva uye maitiro ekugadzira mumitsetse yedu yekugadzira.
Sei Tichifanira Kusarudza Ife?
Yakaratidzwa Track Record
Zvigadzirwa zvedu zvinopa zviuru zvemagetsi munzvimbo dzakasiyana siyana, mumaindasitiri, uye muzvivakwa. Uri kusarudza mutengesi anovimbwa naye muChina nemunyika dzese.
Comprehensive Product Range
Kunze kwe400V Self-healing Capacitor-cylindrical , tinopa mhinduro dzakakwana dzekugovera magetsi dzinosanganisira switchgear, transformers, uye circuit breakers dzine chiyero kubva pa0.4kV kusvika 40.5kV.
Support Technical
Muchawana nhungamiro yehunyanzvi kubva kuchikwata chedu cheinjiniya panguva yekusarudza, kuisa, uye kushanda. Tinokubatsirai kugadzirisa sisitimu yenyu yekugadzirisa simba kuti ishande zvakanaka.
Kukwikwidza Kunobatsira
Mari yedu yakanyoreswa ye30 miriyoni RMB uye kugona kwedu kugadzira zvinhu kwepamusoro-soro kunotibvumira kupa mitengo inokwikwidzana pasina kukanganisa mhando.
Customization Inowanikwa
Chishandiso chako chingada ma voltage ratings chaiwo, capacitance values, kana mounting configurations. Tinopa mhinduro dzakagadzirirwa iwe kuti dzienderane nezvinodiwa zvako chaizvo.
FAQ
Mubvunzo: Ma capacitor aya anowanzogara kwenguva yakareba sei?
A: Kana mamiriro ekushanda akajairwa, unogona kutarisira makore gumi kusvika gumi nemashanu ekushanda pasina kugadziriswa. Chinhu ichi chinozvirapa chinorebesa hupenyu hwekushanda zvichienzaniswa nemarudzi asingarapike.
Mubvunzo: Ndingashandisa ma capacitor e400V pane system ye380V here?
A: Ehe. Chiyero che400V chinopa mukana wakakodzera wekuchengetedza kune network dze380V, inova ndiyo tsika yakajairika mukushandiswa kwecapacitor.
Mubvunzo: Chii chinoitika kana capacitor ikapisa zvakanyanya?
A: Mudziyo wekudzivirira wemukati unobvisa chinhu chakabatwa kubva mudunhu usati wakuvadzwa pahurongwa hwako.
Mubvunzo: Ndinoda here zvinodzivirira kubuda kwemvura kunze?
A: Kwete. Chigadziko chimwe nechimwe chine zvinodzivirira zvinoburitsa mweya zvakabatana zvachose zvinoderedza voltage yemagetsi kusvika padanho rakachengeteka mukati memaminitsi matatu ekubvisa simba.
Mubvunzo: Izvi zvakakodzera here munzvimbo dzine hunyanza hwakakwana?
A: Kune masisitimu ane harmonics dzakakosha, ndapota taurai nesu. Tinogona kukurudzira ma detuning reactors akakodzera kana anti-harmonic capacitor configurations.
Mubvunzo: Ndeupi musiyano uripo pakati pema capacitor e cylindrical ne rectangular?
A: Magadzirirwo esimbi anopa mukana wekushanda zvakanaka kwenzvimbo uye nyore kuisa. Anonyanya kubatsira kana uine hurefu hwakaganhurirwa hwepaneru.
Taura nesu
Wagadzirira kuvandudza simba rako here? Chikwata chedu chehunyanzvi chiripo kuti chikubatsire kusarudza magadzirirwo akakodzera e capacitor yeapp yako.
Email: serina@xaxd-electric.com
Taura nesu nhasi kuti uwane ruzivo rwehunyanzvi, mitengo, kana rutsigiro rweinjiniya yemaapplication. Tichakurumidza kupindura nerubatsiro rwenyanzvi rwakagadzirirwa zvinodiwa nesystem yako yemagetsi.
---
Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd. - Mubatsiri wenyu waunovimba naye wekugadzirisa magetsi zvakakwana. Kubva pa switchgear ine voltage yakakwira neyakaderera kusvika kuma transformer nema capacitor, tinokupai zvigadzirwa zvemhando yepamusoro zvinotsigirwa nebasa rehunyanzvi.
Send Inquiry

_1794560339757.jpg)