sehlahisoaPic

Motlakase oa Matla a Cylindrical oa BKMJ Series

1. Voltage e Lekantsoeng (Ue): 250v ~ 525v, ho fihlela ho 2000v.
2.Maqhubu:50/60Hz.
3. Moralo o moqotetsane, o nang le bolt ea ho thella fatše.
4. Thepa ea ho etsa lipitsa: Resin ea PU (resin e bonolo).
5. Ho kenya le ho kenya dithapo habonolo.
6. Boholo bo bonyenyane, Boima bo bobebe.
7. Ho ipholisa, Ha ho na tlhokomelo.
  • Phano e potlakileng
  • boleng tiisetsa
  • Tšebeletso ea Bareki ea 24/7

Product Introduction

Motlakase oa Matla a Cylindrical oa BKMJ Series

Product Introduction

Na o batla ditharollo tse tshepahalang tsa ho lokisa matla? BKMJ Series Cylindrical Power Capacitor e fana ka tshebetso e ikgethang bakeng sa ditsamaiso tsa hao tsa motlakase. Capacitor ena ya boemo ba premium, e nang le motlakase o tlase e fetola tsela eo o atamelang ho lokisa matla a motlakase ka yona ditshebedisong tsa diindasteri le tsa kgwebo. Ka theknoloji e tswetseng pele ya filimi ya polypropylene e entsweng ka tshepe le moralo o motjha wa cylindrical, o fumana ho qhala ha mocheso ho hoholo le dibopeho tse ntlafetseng tsa polokeho tse fetang di-capacitor tsa setso tse nang le khutlonnetsepa.

Litsamaiso tsa hau tsa motlakase li tšoaneloa ke ts'epo e tlisoang feela ke boenjiniere ba sejoale-joale. Kaho ea rona ea mofuta o omileng e felisa likotsi tsa ho lutla ka botlalo. Lebokose la aluminium le fana ka tšireletso e matla ha sehokelo sa khatello e feteletseng se kopaneng se netefatsa polokeho ea hau maemong a sa lebelloang.

Technical tobileng

paramethara ga tlhaloso
Rated Voltage (Ue) 250V~525V (ho fihlela ho 2000V)
maqhubu 50 / 60Hz
Lisebelisoa tsa Dielectric Filimi ea Polypropylene e Tšepe (MKP)
Casing Boitsebiso aluminium motsoako
Mamello ea Capacitance -5% ho ea ho +10%
Tahlehelo ea Dielectric tan δ ≤ 0.0015
bueloang Mocheso -25 ° C ho + 50 ° C
Moralo oa Bophelo > Lihora tse 100,000
Bokhoni ba Hona Joale Ho fihlela ho 1.3x ka hare ka ho sa feleng
Ho latela Melao IEC 60831-1/2, GB/T 12747

Lintlha Tse ka Sehloohong le Melemo

Theknoloji ea ho Ipholisa : Ha motlakase o phahama, lera la rona la tšepe le fetoha mouoane hang-hang ho potoloha libaka tse nang le phoso. Tšobotsi ena ea katleho e boloka litsamaiso tsa hau li sebetsa ntle le tšitiso.

Moralo o Monyenyane : O tla ananela sebopeho sa cylindrical se bolokang sebaka. E kena habonolo ka har'a likhabote tse thata tsa motlakase ha ka nako e ts'oanang e fana ka mokhoa o motle oa ho qhala mocheso ha o bapisoa le mekhoa e meng e khutlonnetsepa.

Polokeho e Ntlafalitsoeng : Sehokelo sa khatello e feteletseng se kentsweng kahare se arola yuniti ho phepelo ea motlakase ka 'mele nakong ea ho hloleha ha ka hare. Sena se thibela ho phatloha le ho sireletsa lisebelisoa tsa hau.

Ts'ebetso e se nang Tlhokomelo : Thepa ea rona ea ho etsa lipitsa tsa resin ea PU e netefatsa ts'ebetso e tšoarellang nako e telele. U ke ke ua hloka tlhokomelo e sa khaotseng kapa ho nkeloa sebaka khafetsa.

Ho Kenya Habonolo : Ho kenya ha bonolo ka bolt ea fatše ho kenyelelitsoe. Nako ea hau ea ho kenya e fokotseha haholo ka moralo oa rona o bonolo ho o sebelisa.

Liketso tse sebetsang

Tokiso ea Matla a Liindasteri : Lifeme tsa tlhahiso li itšetlehile ka li-capacitor tsa rona bakeng sa libanka tsa PFC tse bohareng. U tla fokotsa likotlo tsa lits'ebeletso ha u ntse u ntlafatsa ts'ebetso ea sistimi ka kakaretso.

Tefo ea Motlakase : Liindasteri tse boima tse kang samente le merafo li rua molemo moralong oa rona o tiileng. BKMJ Series Cylindrical Power Capacitor e sebetsana le maqhubu a phahameng a ho kena le ho thothomela ha mechini hantle haholo.

Mekhoa ea Matla a Nchafatsoang : Lisebelisoa tsa turbine ea moea le mapolasi a letsatsi li sebelisa li-capacitor tsa rona bakeng sa ho sefa ha harmonic. U fumana ts'ebetso e tšepahalang esita le ka li-transients tsa motlakase o potlakileng le maemo a rarahaneng a gridi.

Mehaho ea Khoebo : Meaho ea liofisi le litsi tsa mabenkele li fumana boleng bo betere ba motlakase ka litharollo tsa rona tsa capacitor. Litšenyehelo tsa hau tsa matla lia fokotseha ha botsitso ba sistimi bo ntse bo ntlafala.

How It Works

Tokiso ea matla e etsahala ha matla a arabelang a lefshoa ke matla a capacitive. Filimi ea rona ea polypropylene e entsoeng ka tšepe e boloka matla a motlakase 'me e a ntša ha sistimi ea hau e a hloka haholo.

Moralo oa cylindrical o ntlafatsa kabo ea hona joale. Mocheso o hasana ka ho lekana holim'a bokaholimo ba aluminium, o thibela libaka tse chesang tse senyang mefuta e meng ea capacitor. Ha u kenya BKMJ Series Cylindrical Power Capacitor ea rona , tšebeliso ea matla a arabelang e theoha hang-hang.

Ho iphekola ho etsahala ka bohona nakong ea ho senyeha ho honyenyane. Lesela le entsoeng ka tšepe le fetoha mouoane ho potoloha libaka tse senyehileng, le etsa libaka tse arohaneng tse khutlisetsang mocheso o nepahetseng ntle le thuso ea motho.

Bokhabane ba Tlhahiso

Setsi sa rona sa tlhahiso se boloka maemo a tiileng a boleng mohatong o mong le o mong oa tlhahiso. Re leka capacitor ka 'ngoe tlas'a maemo a potoloho ea mocheso ho netefatsa botšepehi ba ho koala.

Tlhahlobo ea khatello ea motlakase e kenyelletsa tlhahlobo ea ho thibela motlakase ka motlakase o lekantsoeng ka makhetlo a 2.15. Teko ea ho tloha ho terminal ho ea ho khetla e fihla ho 3000V AC bakeng sa netefatso e felletseng ea polokeho. Mekhoa ena e thata e netefatsa hore u fumana lihlahisoa tse fetang maemo a indasteri.

Teko ea botsitso ba mocheso e tsoela pele ka lihora tse 48 mochesong o phahameng. Re lekanya liphetoho tsa capacitance drift le dissipation factor ho netefatsa ts'ebetso e tšepahalang ea nako e telele.

Lebaka Leo re Lokelang ho le Khetha

Xi'an Xikai Medium And Low Voltage Electric Co., Ltd. e tlisa boiphihlelo ba mashome a lilemo ba lisebelisoa tsa motlakase sehlahisoa se seng le se seng. Setifikeiti sa rona sa taolo ea boleng ba ISO9001 se bontša boitlamo ba rona ba ho etsa bokhabane.

U rua molemo ho tsoa ho mefuta ea rona e felletseng ea lihlahisoa e akaretsang mekhahlelo e 9 le mefuta e fetang 100. Bokhoni ba rona ba motlakase bo lekantsoeng bo atoloha ho tloha ho 0.4kV ho isa ho 40.5kV ka litekanyetso tsa hajoale ho fihlela ho 4000A.

Matšoao a tekheniki a fihlela maemo a naha le a machabeng. Lihlahisoa tsa rona li sebetsa ka mokhoa o tšepahalang esita le libakeng tse phahameng tse fetang limithara tse 4000. Ha u re khetha, u khetha theknoloji e pakiloeng e tšehelitsoeng ke boiphihlelo bo boholo ba indasteri.

LBH

P: See se fapana jwang le di-capacitor tse tletseng oli?

K: Moralo oa rona oa mofuta o omileng o felisa likotsi tsa ho lutla ka botlalo ha ka nako e ts'oanang o fana ka mokhoa o betere oa ho qhala mocheso le mekhoa e kopaneng ea polokeho.

P: Ho etsahala eng nakong ea ho phahama ha motlakase?

K: Thepa e iphekolang e arola diphoso hang-hang ka ho fetola lera le entsweng ka tshepe ho potoloha dintlha tsa ho senyeha, e leng se dumellang tshebetso e tswelang pele.

P: Na tsena li ka sebetsana le tikoloho e lumellanang?

K: E, leha re kgothaletsa ho kopanya le di-reactor tse se nang di-detuned ha Total Harmonic Distortion e feta 5% bakeng sa tshebetso e ntle ka ho fetisisa.

P: Ke tlhokomelo efe e hlokahalang?

K: Tlhokomelo e fokolang e hlokahala. Hlahloba dikgokelo tsa terminal nako le nako mme o hlahlobe katoloso ya sekoti e bontshang maemo a ho fela ha bophelo.

P: Nako e lebelletsoeng ea bophelo ke e kae?

K: Lihora tse fetang 100,000 tsa ts'ebetso tlas'a maemo a tloaelehileng. BKMJ Series Cylindrical Power Capacitor e fana ka nako e telele e ikhethang bakeng sa matsete a hau.

Ikopanye Rona - Factop

Na u se u loketse ho ntlafatsa tokiso ea hau ea matla? Sehlopha sa rona sa botekgeniki se ikemiselitse ho u thusa ho khetha tharollo e phethahetseng ea capacitor bakeng sa litlhoko tsa hau tse ikhethileng.

Re romelle imeile ho serina@xaxd-electric.com bakeng sa litlhaloso tse qaqileng, litlhophiso tse ikhethileng, kapa tšehetso ea tekheniki. Re tla arabela kapele ka tataiso ea litsebi e etselitsoeng litlhoko tsa hau tsa kopo.

Qala kajeno ka tokiso e tšepahalang le e sebetsang hantle ea matla e fetolang ts'ebetso ea sistimi ea hau ea motlakase.

romela