sehlahisoaPic

Motlakase oa Tlase oa Shunt Self-Capacitor

1. Voltage e Lekantsoeng (Ue): 250v ~ 525v, ho fihlela ho 2000v.
2.Maqhubu:50/60Hz.
3. Moralo o moqotetsane, o nang le bolt ea ho thella fatše.
4. Thepa ea ho etsa lipitsa: Resin ea PU (resin e bonolo).
5. Ho kenya le ho kenya dithapo habonolo.
6. Boholo bo bonyenyane, Boima bo bobebe.
7. Ho ipholisa, Ha ho na tlhokomelo.
  • Phano e potlakileng
  • boleng tiisetsa
  • Tšebeletso ea Bareki ea 24/7

Product Introduction

Motlakase oa Tlase oa Shunt Self-Capacitor

Product Introduction

Capacitor ea Low Voltage Shunt Self-Capacitor e emela tsoelo-pele theknolojing ea ho lokisa matla a motlakase e etselitsoeng lits'ebetso tsa indasteri ea sejoale-joale. Sesebelisoa sena se tsoetseng pele sa puseletso e sa fetoheng se sebetsa lits'ebetsong tsa motlakase tsa AC tse nang le li-voltage tse fihlang ho 1000V. U tla rua molemo kahong ea filimi ea polypropylene e ipholisang e netefatsang ts'ebetso e tšepahalang. Moralo o mocha o fana ka puseletso e phahameng ea matla a arabelang ha o ntse o boloka maemo a ikhethang a polokeho. Sesebelisoa sena se sebetsana le liphephetso tsa bohlokoa tsa boleng ba motlakase ho kenyeletsoa likotlo tsa matla a tlase, ho se tsitse ha motlakase, le meeli ea bokhoni ba sistimi. Meralo ea hau ea motheo ea motlakase e tla ba le katleho e ntlafetseng le litšenyehelo tse fokotsehileng tsa ts'ebetso ka tharollo ena ea morao-rao.

Technical tobileng

paramethara ga tlhaloso
Rated Voltage (Ue) 250V~525V (ho fihlela ho 2000V hoa fumaneha)
maqhubu 50 / 60Hz
Lisebelisoa tsa Dielectric Filimi ea Polypropylene e Tšepe (MKP)
Sesosa sa ho Tsamaea <0.5W/kvar
Mamello ea Capacitance -5% ho ea ho +10%
bueloang Mocheso -25 ° C ho + 55 ° C
Bophelo bo lebeletseng Bophelo 100,000 ho isa ho 130,000 lihora tsa ts'ebetso
Mamello ea Hona Joale ea Inrush Hona joale e lekantsoe ka makhetlo a 200
Ho latela Melao IEC 60831-1/2, EN 60831
Tšireletso ea Kakaretso IP20 (e tloaelehileng), IP54 (boikhethelo)

Lintlha Tse ka Sehloohong le Melemo

Theknoloji ea ho Ipholisa : Sistimi ea hau e lula e sebetsa esita le ka mor'a ho phahama ha motlakase. Electrode e entsoeng ka tšepe e fetoha mouoane ka bo eona haufi le libaka tse nang le liphoso, e khutlisetsa insulation hang-hang.

Moralo o Monyenyane : O fumana tshebetso e phahameng ka ho fetisisa sebakeng se senyenyane. Kaho e bobebe e kenyelletsa diboutu tse kopaneng tsa ho thella bakeng sa ho kenya habonolo.

Polokeho Pele : Dihokelo tse hatelletsoeng ka ho feteletseng tse kentsweng kahare di sireletsa disebediswa tsa hao. Sistimi e kgaola ka boyona nakong ya diphoso tsa ka hare, e thibela ho hloleha ho kotsi.

Tahlehelo e Tlase : Lahleheloa ke tshenyo e fokolang ya eneji ka mabaka a ho qhala ka tlase ho 0.5W/kvar. Ditjeo tsa hao tsa tshebetso di a fokotseha ha bokgoni ba sistimi bo ntse bo ntlafala.

Ts'ebetso e se nang Tlhokomelo : Hang ha e kentsoe, o ke ke oa hloka tlhokomelo e tloaelehileng. Thepa ea ho etsa lipitsa tsa resin ea PU e netefatsa ts'epo ea nako e telele.

Liketso tse sebetsang

Diphanele tsa Tokiso ya Matla a Iketsang (APFC) : E loketse dibaka tse kgolo tsa tlhahiso moo ho feto-fetoha ha matla ho ntlafatsang puseletso ya matla a arabelang ho latela ditlhoko tsa mojaro wa nako ya nnete.

Mekhoa ea Puseletso ea Motlakase : Hokela ka kotloloho ho li-induction motors merafong, HVAC le lits'ebetsong tsa indasteri. U tla fokotsa tahlehelo ea lithapo tsa feeder le ho ntlafatsa boleng ba motlakase oa lehae.

Tikoloho e Ruileng Harmonic : Ha e kopanngoa le li-reactor tse koetsoeng, li-capacitor tsena li ipabola litsing tse nang le li-drive tsa maqhubu a feto-fetohang le litsamaiso tsa UPS, li thibela mathata a harmonic resonance.

How It Works

Capacitor ea Low Voltage Shunt Self-Capacitor e sebetsa ka ho hlahisa matla a etellang pele a arabelang ho loantša matla a liehang a bakoang ke meroalo ea inductive. Ha e hokahantsoe ka ho lekana le sistimi ea hau ea motlakase, e boloka le ho ntša matla a motlakase ka mokhoa o fapaneng hantle le lisebelisoa tsa inductive.

Nakong ea ho phahama ha motlakase, mokhoa oa ho iphekola o sebetsa hang-hang. Matla a arc a etsa hore electrode ea tšepe e be mouoane ho potoloha ntlha efe kapa efe ea ho senyeha, a hlakola lipotoloho tse khutšoane ka har'a li-microsecond. Ts'ebetso ena e lumella ts'ebetso e tsoelang pele ntle le tšitiso ea fuse.

Sistimi ea polokeho e feteletseng e hlokomela maemo a ka hare. Haeba khase e bokellana ka lebaka la ho senyeha ha likarolo, mokhoa oa sekoahelo o atolohang o khaola yuniti ka bo eona ho gridi ea hau, ho netefatsa polokeho ea basebetsi.

Bokhabane ba Tlhahiso

Ho Xian Xikai Medium And Low Voltage Electric Co., Ltd., re boloka taolo e tiileng ea boleng nakong eohle ea tlhahiso. Ts'ebetso ea rona ea tlhahiso e latela maemo a ISO9001, e netefatsang boleng bo tsitsitseng yuniti e 'ngoe le e 'ngoe.

Re sebelisa filimi ea polypropylene e entsoeng ka tšepe ea boleng bo holimo e nang le matlafatso ea bohale ba zinki-aluminium. Kaho ena e fokotsa khatello ea khatello ea hona joale 'me e eketsa nako ea ts'ebetso. Yuniti ka 'ngoe e feta litekong tse matla ho kenyeletsoa liteko tsa ho thibela motlakase le netefatso ea botsitso ba mocheso.

Setsi sa rona sa tlhahiso se na le lisebelisoa tse tsoetseng pele tsa ho thiba tse iketsang le litsamaiso tsa ho kenya ka nepo. Libaka tsa tlhahlobo tsa boleng li netefatsa mamello ea bokhoni, lintlha tsa ho qhalana, le ts'ebetso ea ts'ebetso ea polokeho pele li romelloa.

Lebaka Leo re Lokelang ho le Khetha

Bokgoni bo Pakiloeng : Ka boiphihlelo bo felletseng ba lisebelisoa tsa motlakase o mahareng le o tlase, re utloisisa liphephetso tsa hau tsa boleng ba motlakase. Potefolio ea rona ea lihlahisoa e akaretsa lihlopha tse 9 tse nang le mefuta e fetang 100.

Ntlafatso ea Tekheniki : Jwalo ka bankakarolo mererong ea lipatlisiso tsa naha, re ntse re ntšetsa pele theknoloji ea capacitor khafetsa. Sehlopha sa rona sa boenjiniere se hlahisa litharollo tse etselitsoeng litlhoko tsa hau tse ikhethileng.

Tšebeletso e Felletseng : Ho tloha puisanong ea pele ho ea tšehetsong ea ho kenya, re fana ka thuso e felletseng ea botekgeniki. Marang-rang a rona a litšebeletso naheng ka bophara a netefatsa karabelo e potlakileng litlhokong tsa hau.

Netefatso ea Boleng : Setifikeiti se tharo (ISO9001, ISO14001, OHSAS18001) se bontša boitlamo ba rona ba boleng, boikarabello ba tikoloho le polokeho ea sebaka sa mosebetsi.

LBH

P: Li-capacitor tsena li hloka tlhokomelo efe?

K: Diyuniti ha di hloke tlhokomelo tlasa maemo a tlwaelehileng a tshebetso. Etsa bonnete ba hore moya o kenang hantle le ho hlahloba matshwao a polokeho nako le nako.

P: Nka lekanya capacitor joang bakeng sa ts'ebeliso ea ka?

K: Bala tlhoko ea hau ea matla a arabelang (kvar) ho latela ntlha ea hona joale ea matla le ntlafatso ea sepheo. Sehlopha sa rona sa tekheniki se ka thusa ka lipalo tsa boholo.

P: Na diyuniti tsena di ka sebetsana le di-switching transients?

K: E, kaho e matla e mamella ts'ebetso ea ho fetola khafetsa e tloaelehileng lits'ebetsong tsa tokiso ea matla a othomathiki.

P: Ho etsahala'ng ha capacitor e fihla pheletsong ea bophelo?

K: Sehokelo sa kgatello e feteletseng se arola yuniti ka bohona, se thibela kotsi efe kapa efe ya polokeho. Ditshupo tse bonahalang di bontsha ha ho hlokahala hore ho nkelwa sebaka.

Ikopanye Rona - Factop

Na u se u loketse ho ntlafatsa matla a hau le ho fokotsa litšenyehelo tsa matla? Litsebi tsa rona tsa tekheniki li eme ho buisana ka litlhoko tsa hau tse ikhethileng.

Imeile : serina@xaxd-electric.com

Ikopanye le rona kajeno bakeng sa litlhaloso tse qaqileng tsa tekheniki, lipalo tsa boholo bo ikhethileng, le litheko tse qothisanang lehlokoa. E re re u thuse ho ntlafatsa sistimi ea hau ea motlakase ka litharollo tsa rona tse tsoetseng pele tsa Low Voltage Shunt Self-Capacitor Capacitor.

romela