ProductPic

I-Harmonic Mitigation Capacitor

1. Ixhotyiswe ngee-resistors zokukhupha umoya.
I-2.Izakhiwo ezintsha kunye nobuchwepheshe obutsha, ukuthembeka okuphezulu.
I-3.Ingxolo ephantsi, ukuchasana okuphezulu kwikhono lokulayisha ngaphezulu, ipropati yombane ifikelele kwinqanaba eliphezulu lamazwe ngamazwe.
4. Ngobuchwepheshe obuphambili bamazwe ngamazwe beefusi zangaphakathi, qinisekisa ukuthembeka kokusebenza kwemveliso. Kuphuculwe indlela yoqhagamshelo yokumelana nokukhupha kwaye kusonjululwe ingxaki ye-over-voltage yecandelo lothotho.
5.Akukho ukuvuza, uhlobo olutsha lwe-bushings oluzenzekelayo lwe-argon arc welding tanks.
  • Ukuhanjiswa ngokukhawuleza
  • quality Assurance
  • 24/7 INkonzo yabaThengi

Intshayelelo Product

I-Harmonic Mitigation Capacitor - Isisombululo soMgangatho wamandla esiPhambili

Intshayelelo Product

Izakhiwo zoshishino zanamhlanje zijongene nemingeni emikhulu yomgangatho wamandla ngenxa yemithwalo engalinganiyo. Inkqubo yakho yombane ifanelwe lukhuseleko ekuguqulweni kwe-harmonic okonakalisa izixhobo kwaye yonyusa iindleko. I-Harmonic Mitigation Capacitor yethu inika isisombululo esikhethekileyo osifunayo sokulungiswa kwamandla okuthembekileyo kwiinethiwekhi zombane ezingcolisiweyo. Ngokungafaniyo nee-capacitors eziqhelekileyo ezingasebenzi phantsi koxinzelelo lwe-harmonic, le nxalenye inzima isebenza ngokukhuselekileyo ecaleni kwee-reactors ezivaliweyo. Ufumana ukhuseleko oluphuculweyo kwi-resonance efanayo, ukugqithisa kwezixhobo, kunye nezohlwayo ezibizayo zeenkonzo. Uyilo lwethu oluphambili lujongana neengxaki ezibalulekileyo zoshishino ngelixa luqinisekisa ukusebenza okuzinzileyo kwiindawo zoshishino ezinzima.

Izikhankanyi Technical

ye parameter ixabiso
Isilinganiselo seVot 400V - 800V
Ubuninzi 50 / 60 HZ
unyamezelo ± 5%
IKlasi yobushushu Iklasi D (-25°C ukuya ku +55°C)
Dielectric Ifilimu yePolypropylene enesinyithi (MKP)
neMigangatho I-IEC 60831-1/2, UL 810
Ukunyamezelana okuphezulu kwe-THD > 20%
Inrush yangoku yaKhona 200x In
Isithinteli soKhuseleko I-Fuse yokukrazula uxinzelelo olugqithisileyo
Ixesha lokukhupha <Imizuzwana engama-60
Iklasi yoBonelelo Iklasi I

Iimpawu eziphambili kunye nezinto eziluncedo

Uyilo olomeleziweyo loKuhlala

Ii-capacitor zethu zineenkqubo ze-dielectric eziqinisiweyo ezimelana noxinzelelo lwe-voltage oluvela kwi-harmonic distortion. Uzuza ngobomi obude bezixhobo kunye neendleko zokulungisa ezincitshisiweyo.

Iimpawu zoKhuseleko oluPhezulu

Zixhotyiswe ngezixhumi zoxinzelelo oluphezulu kunye neefusi zangaphakathi, ezi yunithi zithintela ukungaphumeleli okukhulu. Isixhobo sakho sihlala sikhuselekile kwiingozi zomlilo kunye nomonakalo wezixhobo.

Ulawulo lwe-Thermal olulungiselelwe

Ukwenziwa kwesinyithi esinomphetho onzima kunye nokuphuculwa kokusasazwa kobushushu kuqinisekisa ukusebenza okuzinzileyo phantsi kobushushu obuphezulu. Ufumana ukusebenza okuzinzileyo nakwiindawo zoshishino ezifuna amandla.

Itekhnoloji yokuVuthela ayivuzi

Ii-bushings zohlobo olutsha ezineetanki zokuwelda ze-argon arc ezizenzekelayo zisusa iingozi zokuvuza. Uyakonwabela ukusebenza ngaphandle kokugcinwa kunye nokuthembeka okuphuculweyo.

Ukusebenza kweNgxolo ephantsi

Iindlela zokwakha eziphambili ziyanciphisa ingxolo yokusebenza. Indawo yakho yokusebenza igcina amanqanaba esandi akhululekileyo ngelixa iphucula umgangatho wamandla.

Izicelo eziSebenzayo

Imveliso yoShishino

Iifektri zentsimbi, izakhiwo zesamente, kunye nabavelisi beemoto baxhomekeke kwiHarmonic Mitigation Capacitor yethu ukuze balungise amandla ngendlela ezinzileyo. Ufumana ukhuseleko kwiiharmoniki eziveliswa yiVFD kunye nokuphazamiseka kwesithando somlilo.

Amaziko eNkcukacha kunye neZiseko ze-IT

Izakhiwo ezibalulekileyo ezineenkqubo ze-UPS ezibanzi zifuna ii-capacitor ezikhethekileyo. Isisombululo sethu siqinisekisa ukusetyenziswa kakuhle kwamandla ngelixa sithintela ukuphazamiseka kwe-harmonic kwizixhobo ezinobuthathaka.

Ukuhlanganiswa kwaMandla aVuselelwayo

Ukufakelwa kwelanga nomoya kusebenzisa ii-capacitors zethu ukugcina ukuhambelana kwekhowudi yegridi. Ufumana i-reactive power injection efanelekileyo ngelixa uphatha ii-harmonics eziveliswa yi-inverter.

Ingaba isebenza kanjani

I-Harmonic Mitigation Capacitor yakho isebenza ngaphakathi kwenkqubo ye-reactor ehlukanisiweyo ukuze itshintshe i-resonance frequency isuke kwi-harmonics ezilawulayo. Uqwalaselo lwesekethe ye-LC luthintela i-parallel resonance eyandisa i-harmonic currents eyingozi.

Ii-polypropylene dielectric ezisebenzisa isinyithi zilawula ukunyuka kwamandla ombane okubangelwa luqhagamshelo lwe-reactor olulandelelanayo. Iindlela zokhuseleko lwangaphakathi zijonga uxinzelelo kunye nobushushu, ziqhawula ngokuzenzekelayo ngexesha leemeko zempazamo.

Ufumana uphuculo oluthembekileyo lwezinto zamandla ngaphandle kweengozi ezinxulumene nee-capacitors eziqhelekileyo kwiinethiwekhi ezingcolileyo.

UkuGqwesa kwemveliso

I-Xikai Xikai Medium And Low Voltage Electric Co., Ltd. izisa amava eminyaka emininzi kwimveliso yezixhobo zombane. Inkqubo yethu yolawulo lomgangatho we-ISO9001 iqinisekisa umgangatho wemveliso ohambelanayo.

Sisebenzisa izixhobo eziphambili kunye neendlela zokwenza ngokuchanekileyo. I-capacitor nganye ivavanywa ngokuqatha phantsi kweemeko zokungavisisani kakuhle ngaphambi kokuba ithunyelwe.

Iqela lethu lophando nophuhliso lihlala liphucula uyilo ngokusekelwe kumava entsimi kunye nempendulo yabathengi. Ufumana iimveliso ezihlangabezana neemfuno zesicelo sokwenyani.

Kutheni Sikhetha

Ingxelo egciniweyo yokuKhangela

Inkampani yethu ikhonza iimarike zokusasazwa kombane ngezakhono ezipheleleyo zokudibanisa iinkqubo. Usebenza neengcali ezinamava eziqonda imingeni yakho.

Gqibezela uluhlu lweMveliso

Sinikezela ngeendidi ezili-9 kunye neentlobo ezingaphezu kwe-100 zezixhobo zombane. Iiprojekthi zakho ziyazuza ngokulula kobonelelo lomthombo omnye kunye nokuhambelana kobuchwepheshe.

Uxhaso lobuchwepheshe

Iqela lethu lobunjineli libonelela ngesikhokelo sesicelo kunye nezisombululo ezenzelwe wena. Ufumana uncedo lobuchwephesha kulo lonke ixesha lokuphunyezwa kweprojekthi.

quality Assurance

Zonke iimveliso zihambelana nemigangatho yesizwe neyehlabathi. Ufumana izixhobo ezinokuthenjwa ezixhaswa ziinkqubo zolawulo lomgangatho ezipheleleyo.

FAQ

Q: La ma-capacitor ahluke njani kwii-capacitor ezisemgangathweni zokulungisa amandla?

A: Ii-capacitor eziqhelekileyo azikwazi ukusingatha imisinga ye-harmonic kwaye zihlala zisilela kwiinethiwekhi ezingcolileyo. I-Harmonic Mitigation Capacitor yethu ine-voltage ratings ephuculweyo kunye nezixhobo ze-dielectric eziqinileyo ezenzelwe ngokukodwa iindawo ze-harmonic.

Q: Yeyiphi ipesenti yokunciphisa ekufuneka ndiyikhethe?

A: Iinketho eziqhelekileyo ziquka ukususwa kwe-7% kunye ne-14%. Ukhetho luxhomekeke kwiprofayili ye-harmonic yenkqubo yakho kunye neenxalenye ze-frequency ezilawulayo. Iinjineli zethu zinokunceda ekumiseleni uqwalaselo olufanelekileyo.

Q: Ngaba ezi capacitors zingasebenza ngaphandle kwee-reactors?

A: Hayi, kufuneka basebenzisane nee-reactors ezichongiweyo ukuthintela iingxaki ze-resonance. Indibaniselwano ye-reactor kunye ne-capacitor inika ukunciphisa i-harmonic ekhuselekileyo nesebenzayo.

Umbuzo: Luluphi ugcino olufunekayo?

A: Kufuneka ulondolozo oluncinci ngenxa yolwakhiwo lwethu oluvaliweyo. Kucetyiswa ukuba uhlolwe rhoqo uqhagamshelo kunye nomsebenzi we-discharge resistor.

Q: Ndingayifaka njani ubungakanani bebhanki ye-capacitor?

A: Ubungakanani buxhomekeke kwiimfuno zakho zamandla okusabela kunye namanqanaba e-harmonic. Sinikezela ngenkxaso yobugcisa ukuqinisekisa uyilo olufanelekileyo lwenkqubo.

Qhagamshelana nathi

Ngaba ukulungele ukusombulula iingxaki zakho zomgangatho wamandla? Iqela lethu lobuchwephesha likulungele ukukunceda ukhethe isisombululo seHarmonic Mitigation Capacitor esifanelekileyo kwisicelo sakho.

Nxibelelana neengcali zethu namhlanje ukuze ufumane inkxaso yobugcisa eyenzelwe wena kunye neekowuteshini. Sinikezela ngohlalutyo olupheleleyo lwenkqubo kunye neengcebiso ezenziwe ngokwezifiso.

I-imeyile: serina@xaxd-electric.com

Guqula umgangatho wamandla wesakhiwo sakho ngezisombululo zethu zokunciphisa i-harmonic eziphambili. Izixhobo zakho zifanelwe kukukhuselwa kwi-harmonic distortion - makhe sikuncede ukufezekisa oko.

thumela