ProductPic

Isihluzi seSigaba esinye

1. Ixhotyiswe ngee-resistors zokukhupha umoya.
I-2.Izakhiwo ezintsha kunye nobuchwepheshe obutsha, ukuthembeka okuphezulu.
I-3.Ingxolo ephantsi, ukuchasana okuphezulu kwikhono lokulayisha ngaphezulu, ipropati yombane ifikelele kwinqanaba eliphezulu lamazwe ngamazwe.
4. Ngobuchwepheshe obuphambili bamazwe ngamazwe beefusi zangaphakathi, qinisekisa ukuthembeka kokusebenza kwemveliso. Kuphuculwe indlela yoqhagamshelo yokumelana nokukhupha kwaye kusonjululwe ingxaki ye-over-voltage yecandelo lothotho.
5.Akukho ukuvuza, uhlobo olutsha lwe-bushings oluzenzekelayo lwe-argon arc welding tanks.
  • Ukuhanjiswa ngokukhawuleza
  • quality Assurance
  • 24/7 INkonzo yabaThengi

Intshayelelo Product

Isixhobo sokucoca esiSigaba esinye - Izisombululo zoMgangatho waMandla zobuNgcali

Intshayelelo Product

Xa ufuna i-power conditioner ethembekileyo kwiinkqubo zakho zombane, i-Single-Phase Filter Capacitor yethu inika ukusebenza okugqwesileyo kunye nokuqina. Le nxalenye ikhethekileyo yokugcina amandla yenzelwe ukusebenza rhoqo kwiisekethe zombane zesigaba esinye, ilungisa ngokufanelekileyo ukuguquguquka kwe-voltage kunye nokuthintela ukuphazamiseka kwe-electromagnetic. I-Single-Phase Filter Capacitor yethu inetekhnoloji yefilimu ye-polypropylene ephucukileyo, ebonelela ngezakhono zokucoca eziphezulu kwizicelo ze-elektroniki zamandla zanamhlanje.

Ii-capacitor zethu zisombulula imingeni ebalulekileyo yomgangatho wamandla kwiindawo zoshishino nezorhwebo. Zisusa ukuphambuka kwe-harmonic, zinciphisa i-DC bus ripple, kwaye zikhusela izixhobo ezibuthathaka kwi-spikes yengxolo ethwalwa yigridi.

Izikhankanyi Technical

ye parameter ixabiso umgangatho
Rtage Range I-AC engama-250V - 1000V IEC 61071
Capacitance 1μF - 100μF ±5% ukunyamezela
ngamaqondo yokusebenza -40 ° C ukuya kwi-105 ° C Uluhlu olwandisiweyo
Izinto zeDielectric I-Polypropylene enesinyithi Ukuziphilisa
ESR < 0.1Ω Uyilo oluphantsi lokulahleka
ESL < 10nH Ukucoca rhoqo
Ukwambathisa Resistance > 10GΩ Ukwahluka okubalaseleyo
Ukhuseleko Rating UL 810, IEC 61071 Ukuthobela amazwe ngamazwe
Ukuvalwa IP65 iyafumaneka Ukukhuselwa kwendalo
Ayanda Iinketho ze-PCB/Chassis Ukufakwa ngokulula

Iimpawu eziphambili kunye nezinto eziluncedo

Itekhnoloji yokuZiphilisa ePhambili

Ii-capacitors zethu zinefilimu ye-polypropylene eyenziwe ngesinyithi. Xa kuvela ii-voltage spikes, i-metallization iyajika ibe ngumphunga ngokuzenzekelayo kwiindawo ezineziphene, ukuqinisekisa ukusebenza okuqhubekayo.

Ukusebenza okuphezulu kweThermal

Yenzelwe iimeko zobushushu obuphezulu ukusuka kwi -40°C ukuya kwi +105°C. Olu luhlu olubanzi lokusebenza luqinisekisa ukusebenza okuthembekileyo kwiindawo ezifuna amandla amaninzi.

Uyilo lweESR ephantsi

Ukumelana nochungechunge olulinganayo oluphantsi kakhulu kunciphisa ukuzifudumeza phantsi kwemisinga enamandla aphezulu. Olu yilo lwandisa ubomi benkonzo kwaye luphucula ukusebenza kakuhle kokucoca.

Uxinano lwamandla aMancinci

Uyilo olusebenzisa indawo kakuhle luvumela ukuhlanganiswa kwezakhiwo zekhabhinethi ezilawulwa ngokuqinileyo ngaphandle kokuphazamisa ukusebenza.

Iimpawu zoKhuseleko ezongeziweyo

Izixhumi zoxinzelelo olugqithisileyo kunye netekhnoloji yefilimu ehlukanisiweyo zithintela ukungaphumeleli okukhulu, zikhusela yonke inkqubo yakho yombane.

Izicelo eziSebenzayo

Iinkqubo ze-UPS zeSigaba esinye

Ii-capacitors zethu zigqwesile kwinqanaba le-DC link kwiinkqubo ze-UPS eziguquliweyo kabini kwi-intanethi. Zilungisa i-voltage ukuze zikhusele idatha ebalulekileyo ngexesha lokucima kombane kunye nokuguquguquka kwegridi.

Ii-Inverters ze-PV zelanga

Ifanelekile kakhulu kwiifowuni zelanga ezihlala abantu ukusuka kwi-3kW ukuya kwi-10kW. Ezi yunithi ziqinisa i-DC bus voltage evela kwiiphaneli zelanga, ziqinisekisa ukusebenza kakuhle kokulandelela iindawo zamandla.

Iitshaja zeZithuthi zoMbane

Ilungele izitishi zokutshaja ze-AC zeNqanaba loku-1 kunye neNqanaba lesi-2. I-Single-Phase Filter Capacitor yethu iphatha ukungcangcazela kwaye inika amandla amancinci kwiimoto.

IiMoto zokuqhuba

Kubalulekile kwiidrives eziguquguqukayo kunye neenkqubo ze-servo apho umgangatho wamandla uchaphazela ngokuthe ngqo ukusebenza kunye nobude bexesha lezixhobo.

Ingaba isebenza kanjani

I-Single-Phase Filter Capacitor yakho isebenza ngokudala indlela ye-low-impedance yengxolo ephezulu ngelixa igcina amandla ombane ukuvala izikhewu kwii-AC waveforms ezilungisiweyo.

I-dielectric yefilimu ye-polypropylene eyenziwe ngesinyithi igcina itshaja yombane ngokufanelekileyo. Ngexesha lokusebenza, i-capacitor iyatshaja xa i-voltage yokufaka inyuka kwaye ikhupha xa i-voltage yehla, nto leyo elungisa ukuhanjiswa kombane ngokubanzi.

Ingxolo yokutshintsha isandi esiphakamileyo ifumana indlela elula kuyilo oluphantsi lwe-ESL ye-capacitor. Oku kuthintela ukuphazamiseka ekufikeleleni kwizinto ezinobuthathaka ezisezantsi.

Indlela yokuziphilisa ngokwayo isebenza ngexesha le-voltage transients, ihlukanisa ngokuzenzekelayo iimpazamo kwaye igcina ingqibelelo yesekethe.

UkuGqwesa kwemveliso

I-Xikai Xikai Medium and Low Voltage Electric Co., Ltd. izisa amashumi eminyaka olwazi lwezixhobo zamandla kuzo zonke ii-capacitor esizenzayo. Inkqubo yethu yolawulo lomgangatho eqinisekisiweyo yi-ISO9001 iqinisekisa ukuthembeka kwemveliso rhoqo.

Sisebenzisa imigca yemveliso ezenzekelayo ephucukileyo enezixhobo zokujika ngokuchanekileyo kunye novavanyo loxinzelelo lokusingqongileyo. Iyunithi nganye ivavanywa ngokungqongqo kubandakanya ukumelana nombane, ukulinganiswa kwe-capacitance, kunye nokujikeleza kobushushu.

Iqela lethu lophando nophuhliso lihlala liphucula uyilo ngokusekelwe kwidatha yokusebenza kwentsimi kunye neemfuno zoshishino ezikhulayo. Sigcina ubudlelwane obucwangcisiweyo nababoneleli bezinto eziphambili ukuqinisekisa umgangatho wezinto.

Ulawulo lomgangatho lufikelela kulo lonke uthotho lwethu lokubonelela. Izinto ezingenayo ziyahlolwa kwaye zivavanywe ngaphambi kokuba zisetyenziswe kwimveliso. Iimveliso zokugqibela zivavanyelwa umbane ngokupheleleyo kwaye zivavanyelwe ngokungacwangciswanga ukuze kuqinisekiswe ubomi obude.

Kutheni Sikhetha

Amava oShishino olungqiniweyo

Ngamava amaninzi kwizixhobo zokusasaza amandla ombane aphakathi naphantsi, siyaqonda imingeni yokwenyani ejongene nayo izicelo zakho.

Uxhaso lobuchwepheshe

Iqela lethu lobunjineli libonelela ngoncedo lwesicelo, likunceda ukhethe iinkcukacha ezifanelekileyo ze-capacitor ezihambelana neemfuno zakho ezithile.

Ikhonkco loNikezo elithembekileyo

Sigcina amanqanaba afanelekileyo empahla kunye namandla emveliso aguquguqukayo ukuze sihlangabezane neeshedyuli zakho zokuhambisa rhoqo.

Ixabiso lokuKhuphisana

Amaxabiso ngqo kumenzi asusa iimpawu zomthengisi ngelixa egcina imigangatho yomgangatho ophezulu.

Iwaranti eBanzi

I-capacitor nganye iqulethe iwaranti epheleleyo kunye nenkxaso yobugcisa ephendulayo kuyo yonke i-lifecycle yemveliso.

FAQ

Q: Oku kwahluke njani kwii-capacitors zokuqala iimoto?

A: Ii-capacitor zethu zesihluzo zenzelwe umsebenzi oqhubekayo kunye noyilo oluphantsi lwe-ESR. Ii-capacitor zokuqala iimoto zezokusetyenziswa okwethutyana kwaye ziya kusilela ukuba zisetyenziselwa ukucoca.

Q: Yintoni echaphazela ubomi be-capacitor?

A: Ubushushu bokusebenza yeyona nto iphambili. Ukunyuka kobushushu nge-10°C kunciphisa ubomi benkonzo obulindelekileyo. Ulawulo olufanelekileyo lobushushu lubalulekile.

Q: Ndingazitshintsha nini ezi capacitors?

A: Buyisela endaweni xa i-capacitance yehla nge-5-10% ngaphantsi kwexabiso eliqhelekileyo okanye xa i-dissipation factor inyuka ukuya kwiinkcazo zokuqala eziphindwe kabini ukuya kathathu.

Q: Kutheni i-ESL ephantsi ibalulekile?

A: Ukungena kochungechunge olulinganayo oluphantsi kuqinisekisa ukuhluzwa kwengxolo okusebenzayo okune-frequency ephezulu, okubalulekileyo kwizixhobo zamandla zokutshintsha zanamhlanje kunye nee-inverters.

Q: Ngaba ezi zinto zingamelana nokunyuka kwamandla ombane?

A: Ewe, itekhnoloji yefilimu eziziphilisayo ngokwayo iyazihlukanisa ngokuzenzekelayo iimpazamo ezibangelwa kukuqhekeka, ithintela imijikelo emfutshane kwaye yandise ubomi benkonzo.

Qhagamshelana nathi

Ngaba ukulungele ukuphucula umgangatho wakho wamandla ngezisombululo ze-capacitor ezikumgangatho ophezulu? Iqela lethu lobuchwephesha likulungele ukukunceda ukhethe i-Single-Phase Filter Capacitor efanelekileyo kwisicelo sakho.

Qhagamshelana nathi namhlanje ukuze ufumane iinkcukacha ezineenkcukacha, uqwalaselo olwenziwe ngokwezifiso, okanye ingcebiso yobugcisa:

I-imeyile: serina@xaxd-electric.com

Masikuncede ufezekise ukusebenza kakuhle kokulungisa amandla ngezisombululo zethu ze-capacitor ezithembekileyo nezisemgangathweni ophezulu.

thumela