Khetha iTransformer enokubakho yangaphandle: Isikhokelo esipheleleyo
2026-06-15 15:40:51
Xa ukhetha i- Outdoor Potential transformer , kufuneka ufumane ibhalansi phakathi kokuchaneka kobuchwephesha kunye nokuqina kwiindawo ezinzima. Ezi zixhobo zokulinganisa i-voltage zezona zinto zibalulekileyo kwiziseko zombane kwizikhululo, kwiifektri, nakwiigridi zezixhobo. Zithoba i-voltage ephezulu ukuya kumanqanaba anokusetyenziswa ziimitha kunye neeswitshi zokhuseleko. Ii-Outdoor Potential transformers kufuneka zijongane nemvula, utshintsho lobushushu, ukukhanya kwe-UV, kunye nokungcola, oko kuthetha ukuba umgangatho wezixhobo kunye namandla oyilo kufuneka ube phezulu. Esi sikhokelo sithetha ngezinto ezibalulekileyo ezichaphazela ixesha lokusebenza, ukuchaneka, kunye neendleko zobunini zizonke. Inceda amaqela okuthenga ukuba ahambelane neenkcukacha zezixhobo kunye neenkcukacha zokusebenza ukuze iimpazamo ezibizayo zingenzeki okanye izixhobo zisilele ngokukhawuleza ebaleni.
Ukuqonda iiTransformers zangaphandle: Iziseko kunye nemisebenzi
Zenza ntoni iiTransformers zangaphandle?
Xa ii-voltage transformers zifakelwe ngaphandle, zehlisa imiqondiso yombane ene-high-voltage ukuya kwi-secondary outputs eziqhelekileyo, ezidla ngokuba yi-100V okanye i-120V. Oku kwenza kube lula ukuqhagamshela kwiimitha, ii-relay, kunye neenkqubo zokulandelela. Kwiibhili zombane, ukulinganisa i-voltage ngokuchanekileyo kubaluleke kakhulu, kwaye kwizityalo zoshishino, ukulungelelaniswa kwe-relay yokukhusela nako kubaluleke kakhulu. I-transformer ye-35kV yokungenisa i-voltage yangaphandle, njengee-epoxy resin-cast ezihlangabezana nemigangatho ye-IEC 61869-1 kunye ne-61869-2, yehlisa i-voltage ukuya kwi-10kV output values ezilungileyo kwizixhobo ezisemgangathweni. Olu tshintsho lwenzeka ngokungeniswa kwe-electromagnetic ngaphakathi kwe-magnetic core, kunye nempazamo encinci kakhulu kwi-phase angle kunye ne-ratio.
Iimpawu zokwakha ezakhelwe izinto
Ngenxa yokuba umsebenzi wangaphandle unzima kakhulu, udinga iindlela ezikhethekileyo zokwakha. I-electromagnetic core kunye ne-windings zigqunywe ngokupheleleyo kwi-epoxy resin casting. Oku kuthetha ukuba akukho zikhewu kwizinto apho umswakama unokungena khona uze ubangele ukuqhambuka kwangaphakathi. Olu yilo luvalwe ngokupheleleyo lwahlukile kakhulu kwiindlela ezizaliswe yioyile, ngoko ke akufuneki wenze naluphi na ulondolozo olufana nokujonga inqanaba lolwelo okanye ukulungisa ukuvuza. Iindlu ezimelana nemozulu ezine-IP65 okanye ngaphezulu zikhusela iindawo zangaphakathi eluthulini nakwiijethi zamanzi. Iipolymer zangaphandle ezizinziswe yi-UV zigcina zingaqhekeki xa zichatshazelwa lilanga ngokuthe ngqo ixesha elide. Izixhobo kunye noqhagamshelo olwenziwe ngentsimbi engagqwaliyo emelana nokugqwala zihlala ixesha elide kwiindawo eziselunxwemeni apho ityuwa itshiza ngokukhawuleza ukuqhekeka kwezinto.
Izicelo kuzo zonke iziseko zombane
Iitransformer zeVolthi zisetyenziswa kwiifektri ukujonga umgangatho wamandla aya kwiimashini zeCNC kunye nemigca yokuhlanganisa ezenzekelayo. Ukuba i-voltage iyehla okanye kukho ukuphambuka kwe-harmonic, inefuthe ngqo kubungakanani bomsebenzi owenziwayo. Ezi zixhobo zisetyenziswa ziindawo zedatha ukuqinisekisa ukuba imilinganiselo isoloko ichanekile ekutshintsheni udluliselo lwezixhobo kunye nokulungelelaniswa kwejenereyitha yogcino. Iitransformer zePotential zangaphandle zifakwa ngabasebenzi bothumelo kunye nosasazo kwizikhululo ukuze banike izalathiso zevolthi kwiiswitshi zomgama ezikhusela imigca yothumelo ehamba amakhulu eemayile. Ukulinganiswa kwevolthi ngokuchanekileyo kuyafuneka ukuze kuvumelaniswe iziphumo ze-inverter kunye ne-grid frequency kunye ne-phase angle kwiindawo zamandla avuselelekayo njengeefama zelanga kunye neepaki zomoya. Oku kuthintela ukuqhawuka okubizayo ukuba kungenzeki ngexesha le-cloud transients okanye i-wind gusts.
IiTransformers zangaphandle kunye nezangaphakathi: Umahluko kunye nezinto ekufuneka uziqwalasele xa ukhetha
Umahluko kwiZakhiwo nakwiNdalo
Yonke into eyahlukileyo kuyilo phakathi kwee-transformers ze-voltage zangaphandle nezangaphakathi ibangelwa yimeko-bume. Iiyunithi zangaphakathi zisebenza kumagumbi okutshintsha-tshintsha alawulwa yimozulu agcina ubushushu buzinzile, umswakama uphantsi, kwaye zisebenzisa iinkqubo ze-HVAC ukugcina uthuli kunye neetyhefu zingangeni kumagumbi. Le meko-bume ilawulwayo ivumela iinkqubo zokukhusela ukuba zikhaphukhaphu kwaye iindonga zingabi namandla kangako, nto leyo enciphisa ixabiso lezinto kunye nobukhulu besakhiwo. Kwii -transformers ze-Outdoor Potential , amaqondo obushushu anokusukela kwi -40°C ukuya kwi +55°C. Oku kuthetha ukuba izinto zokukhusela kufuneka zikwazi ukugcina amandla azo ombane kulo lonke olu luhlu ngaphandle kokuqhekeka okanye ukwahlukana. Xa lina, ikhephu, okanye iqhwa, indlu kufuneka ithambeke ukuze amanzi aphume kwiindawo zokudibanisa. Abahluli berabha be-porcelain okanye i-silicone bagcina umphezulu ungashukumi xa umanzi.
Iimfuneko Zokusebenza Nokugcinwa
Nokuba i-transformer enokwenzeka isebenza ngaphakathi okanye ngaphandle, kufuneka ihlangabezane neemfuno ezifanayo zeklasi yokuchaneka: ukulinganiswa kweklasi ye-0.2 okanye ye-0.5 kwimisebenzi yokulinganisa ingeniso, kunye nokulinganiswa kweklasi ye-3P kwimisebenzi yokhuseleko ngokubanzi. Kodwa uxinzelelo lokusingqongileyo lunemiphumo eyahlukileyo ekuhambeni kokuchaneka kwexesha elide. Iiyunithi zangaphandle zidlula kutshintsho oluninzi lobushushu, okwenza ii-core laminations kunye neentambo ezijikelezayo zande kwaye zinciphe. Uxinzelelo lwe-coil olulawulwayo kunye neenkqubo zokubambelela kwe-core kwiindlela ezisemgangathweni ophezulu zenza oku ngokugcina uzinzo loomatshini amashumi eminyaka. Ii-Outdoor Potential transformers ezine-epoxy resin insulation zihlala zifuna ukugcinwa rhoqo kunezoyilo ezizaliswe yioyile kuba ulwakhiwo oluvaliweyo lugcina umswakama ngaphandle, nto leyo enciphisa ukumelana kwe-insulation. Kunokuba yimfuneko ukucoca uthuli olujikeleze imingxunya yomoya kwiiyunithi zangaphakathi rhoqo, kodwa kufuneka uphephe ukuvumela imozulu yonakalise umphezulu wangaphandle kunye nezitywino.
Iingqwalasela zeendleko kunye nohlalutyo lobunini obupheleleyo
Ngenxa yobushushu obungcono, iindawo ezivalekileyo ezimelana nemozulu, kunye nezinto ezingagqwaliyo, ii-transformers ze-Outdoor Potential zibiza ngaphezulu ngama-25–40% ekuqaleni kuneexabiso ezifanayo zangaphakathi. Xa abaphathi bokuthenga bejonga iindleko zizonke zobunini, kufuneka babandakanye iindleko zokufakela. Iiyunithi zangaphandle zihlala zifakwa kwizakhiwo ezahlukeneyo okanye kumaqonga eepali, okongeza iindleko zesiseko kunye nezakhiwo ezingekhoyo ekufakweni kwe-switchgear yangaphakathi. Kodwa ii-transformers ze-Outdoor Potential ziyasusa isidingo sokwakha amagumbi e-transformer ahlukeneyo, oko konga imali kwiindleko zokwakha kunye nezindlu kwiindawo ezinqongopheleyo. Ukufikeleleka kokulungiswa kufuneka kuthathelwe ingqalelo kuhlalutyo lweendleko zomjikelo wobomi. Umzekelo, ukuhlola iiyunithi zangaphandle kunokufuna iilori zebhakethi okanye iileli, kodwa izixhobo zangaphakathi zinokufikelelwa ngokuhamba. Amanqanaba ahlukeneyo okuthembeka achaphazela iindleko zokutshintshwa. Umzekelo, ukuba iyunithi yangaphandle iyasilela, ii-feeders ezininzi zinokufuna ukulungelelaniswa ukuze kucinywe. Kwelinye icala, ukulinganisa okungafunekiyo kwangaphakathi kukunika inkululeko esebenzayo ngexesha lokulungisa izithuba.
Ungayikhetha njani iTransformer enokwenzeka yangaphandle efanelekileyo kwiprojekthi yakho?
Ukufanisa Iinkcukacha Zobuchwephesha Neemfuno Zenkqubo
I-voltage eqhelekileyo yenkqubo kunye nomda wokhuseleko isetyenziselwa ukukhetha udidi lwe-voltage. Umzekelo, ii-transformers ezinokubakho ezilinganiswe nge-35kV zisebenza neenethiwekhi zokusasazwa kwe-34.5kV kuba zibonelela ngolungelelwaniso lokufakelwa kwe-insulation kwii-overvoltages zexesha elifutshane ezenzeka ngexesha lokusebenza kokutshintsha okanye iingxaki zomhlaba. Amazinga okuphindaphindeka kwi-50/60Hz dual compatibility avumela iiprojekthi ukuba zisetyenziswe kwihlabathi liphela ngaphandle kokutshintsha iinkcukacha. Umthamo wamandla ophambili olinganisiweyo, onokuba yi-600A okanye i-800A, ukuxelela ukuba ukusebenza kobushushu kuya kuba njani xa umthwalo ugcwele. Oku kugcina ukuchaneka kungashukumi xa amasimi e-electromagnetic edalwa ziijenereyitha zamandla ezikufutshane okanye ii-reactors. Umthamo womthwalo wemveliso, onikwe kwi-volt-amperes (VA), kufuneka ube phezulu kune-impedance iyonke yazo zonke iimitha ezidityanisiweyo, iiswitshi, kunye nezixhobo zokubonisa nge-20%. Ukukhetha udidi lokuchaneka kuxhomekeke kumsebenzi okhoyo. Umzekelo, i-income metering idinga ukuchaneka kweklasi ye-0.2, ngelixa i-protective relaying inokwenza ngeeyunithi zeklasi ze-0.5.
Ukuphonononga iiMqinisekiso zoMboneleli kunye neziQinisekiso
Yenza uhlolo lweemfaneleko uphonononge iinkqubo zomgangatho kunye nobuchule bokuvelisa. Isatifikethi se-ISO 9001 siqinisekisa ulawulo lomgangatho olumiselweyo. Isatifikethi semveliso se-IEC 61869 sibonisa ukuthotyelwa kokhuseleko lwamazwe ngamazwe. Iimvume zengingqi (ANSI C57.13, GB 20840.2-2014) zibonisa ukuguquguquka kwemithetho. Iziqinisekiso ze-PT zangaphandle zihlala iminyaka emi-5-10. Ababoneleli abanamaziko eenkonzo zengingqi babonelela ngenkxaso yokugunyazisa ngokukhawuleza kunabavelisi abakude.
Ukufakela, Ukugcinwa, kunye neMikhwa eBalaseleyo yeeTransformers zangaphandle
Izikhokelo zokuFakelo zeNyathelo ngeNyathelo
Ukujonga amandla kunye nomgangatho wesiseko linyathelo lokuqala lokulungiselela indawo. Oku kungenxa yokuba iindawo zokufakelwa ezingalinganiyo zibeka uxinzelelo loomatshini kwi-insulators ze-ceramic nakwiindawo zokudibanisa. Ii-transformers zangaphandle ezinokubakho zifakwa kwizakhiwo ezikhethekileyo zentsimbi, ii-concrete pads, okanye ii-pole clamps ezenzelwe ukuphatha imithwalo yomoya kunye namandla e-seismic afunekayo ngokweekhowudi zesakhiwo zasekuhlaleni. Ukuze izixhobo zikhuseleke kwaye imilinganiselo ichaneke, ii-grounding conductors kufuneka ziqhagamshelane ne-substation ground grid enokumelana ngaphantsi kwe-1 ohm. Oku kufuneka kuqinisekiswe ngovavanyo olunokwenzeka ngaphambi kokuba izixhobo zivulwe. Ukugcina amalungu ekhululekile kwaye abangele ukwehla kobushushu kunye ne-voltage, uqhagamshelo oluphambili kufuneka luqiniswe kwizikrufu zesiphelo kusetyenziswa i-torque elawulwa ngumenzi. Imigca yamandla enamandla aphezulu yahlulwe ngokwasemzimbeni kwi-wire yesibini ehamba kwi-conduit okanye kwiitreyi zekhebula. Oku kugcina ukuphazamiseka kwe-electromagnetic okunokuchaphazela ukuchaneka kokulinganisa kube kuncinci.
Iishedyuli zoLondolozo lwesiqhelo kunye nokusombulula iingxaki
Ukucoca rhoqo ngonyaka: jonga ukuthembeka kwendlu, jonga iintanda zeporcelain, izitywini zemozulu. Umfanekiso we-thermal ufumana uqhagamshelo olushushu (10°C ngaphezulu kwe-ambient ibonisa izixhobo ezikhululekileyo). Uvavanyo lokumelana nobushushu olune-5kV megohmmeters—ukufundwa okungaphantsi kwe-1000 megohms kufuna uphando. Jonga i-voltage yemveliso yesibini ngokuchasene neereferensi ezilinganisiweyo. Iifusi zesibini ezivuthuziweyo zihlala zibonisa ii-short circuits ezisezantsi, hayi iimpazamo ze-transformer.
Ukunciphisa imingeni yokuSingqongileyo
Iindawo ezikunxweme: hlamba iindawo zangaphandle ngamanzi amatsha rhoqo ngekota ukuze ususe iingqimba zetyuwa eqhubayo. Amaqondo obushushu aphezulu: yongeza izinto zokufudumeza ukuthintela ukufuma; sebenzisa izithunzi zelanga okanye izinto ezibonisa ukukhanya entlango. Faka ucingo olukhuselayo olujikeleze ii-PT ezifakwe ezantsi ukuze uthintele izilwanyana kunye nabantu abenzakalisayo. Kwiindawo ezithandwa ngumkhenkce, yenza uhlolo rhoqo lwe-insulator yasebusika. Izivalo zokungena zekhebula ezifudumeleyo zithintela ukungena kwamanzi.
Ulwazi malunga nokuThenga: Amaxabiso, ukuhanjiswa, kunye nokuThembeka kwabaThengisi
Ukuqonda iinguqu zexabiso kunye noCwangciso lweBhajethi
Udidi lweVolthi, iimfuno zokuchaneka, kunye nezixhobo zokwakha zonke zichaphazela ixabiso le-transformer yangaphandle . Ixabiso elisisiseko leeyunithi eziqhelekileyo ze-35kV ezine-0.5 accuracy class kunye ne-epoxy resin insulation limiselwe. Ukuphucula ukuya kwi-0.2 class precision yokulinganisa ingeniso kongeza iindleko ezongezelelweyo ngenxa yemida yemveliso eqinileyo kunye nokukhetha izinto eziphambili ezahlukeneyo. Izicelo zokwenza ngokwezifiso, ezifana ne-voltages ezingezizo ezisemgangathweni, ukuseta okukhethekileyo, okanye ukulinganiswa okuphezulu kwe-seismic, kwenza iindleko zobunjineli zinyuke kwaye amaxesha okulinda akhule. Amaxabiso eyunithi achatshazelwa yivolumu kakhulu; amaqela okuthenga a-odola iiyunithi ezingama-50 nangaphezulu kwiiprojekthi zomgca wokuhambisa anokufumana ukonga ukuya kuthi ga kwi-25-25 yepesenti xa kuthelekiswa nokuthenga iyunithi enye. Ukuthengwa kwamanye amazwe kuchatshazelwa yimigaqo yokuhlawula kunye notshintsho kwiimali. Kwiiprojekthi ezithatha iminyaka emininzi yemali, kulungile ukuseta uhlahlo-lwabiwo mali kwangethuba kwaye usebenzise amaqhinga orhwebo.
Amaxesha okukhokela kunye nokulungelelaniswa kokuhanjiswa kweenkonzo
Ii-PT eziqhelekileyo zesitokhwe sangaphandle zithunyelwa kwiiveki ezisi-8-12 emva kokuqinisekiswa kwe-odolo. Iiyunithi ezenziwe ngokwezifiso zifuna iiveki ezili-16-20 ukuze zivunywe uyilo, uvavanyo lweprototype, kunye nokuseta imveliso. Izixhobo zombane ezithwala impahla zifuna abathuthi abakhethekileyo abanezixhobo zokulungisa kunye ne-inshurensi. Lungelelanisa imihla yokuhanjiswa neenjongo zokwakha ukuze uphephe ukugcinwa okubizayo kwindawo. Bandakanya amanyathelo okuhlola: ukuqinisekiswa kwegama, ukujonga umonakalo wokuthunyelwa, uvavanyo lokwamkelwa.
Ukuchonga Ababoneleli Abanokuthenjwa kunye neZiseko zoNcedo
Jonga iireferensi ezivela kubathengi bangaphambili abanezicelo ezifanayo. Abavelisi abaziwayo babonisa ukubakho kweminyaka emininzi kwimarike, izifundo ezipapashiweyo, kunye nokuzimisela ukutyelela izityalo. Ukufikelela kwinkxaso yobugcisa: ubunjineli bezicelo zoncedo lweenkcukacha; inkonzo yabathengi iiyure ezingama-24 ngosuku, iintsuku ezisi-7 ngosuku, iintsuku ezisi-7 ngosuku ukuze kusonjululwe ingxaki yasentsimini. Imigaqo yewaranti ecacileyo egubungela iziphene kunye neenkqubo zokutshintsha. Iziqinisekiso ze-ISO 14001 okanye ze-OHSAS 18001 zibonisa uxanduva lokuvelisa.
isiphelo
Iimfuno zobugcisa kufuneka zilungelelaniswe nexesha elide lokusingqongileyo kunye neendleko zomjikelo wobomi xa ukhetha i- Outdoor Potential transformer . Amanqanaba e-voltage, udidi lokuchaneka, uhlobo lokufakelwa, kunye nokuthobela imithetho zenza isiseko sobugcisa. Impumelelo yokusebenza kwexesha elide ixhomekeke ekubeni imelana kakuhle kangakanani nemozulu, ukuba kulula kangakanani ukuyigcina, kunye nokuba umboneleli uxhasa njani iziseko zayo. Nokuba uza kusebenzisa i-voltage transformer yangaphandle okanye yangaphakathi kuxhomekeke ekubeni ufuna ukuyibeka phi, ixabisa malini, kunye nendlela othanda ukuyiphatha ngayo. I-transformer ye-voltage yangaphandle ye-35kV evela kwi-Xi'an Xikai ibonisa indlela ubuchwepheshe be-epoxy resin bangoku obunokusetyenziswa ngayo ukulinganisa i-voltage ngokuchanekileyo kwiimeko ezinzima zasentsimini, ngelixa ikwahlangabezana nemigangatho yamazwe ngamazwe kwaye ivelisa iimveliso ezisemgangathweni ophezulu. Kungcono ukuba amaqela okuthenga ajonge iindleko zobunini zizonke endaweni yexabiso lokuthenga lokuqala kuphela. Oku kuthetha ukuthathela ingqalelo izinto ezifana neendleko zokufakela, iimfuno zokulungisa, kunye nokuba inkqubo ithembeke kangakanani na ngokwexesha lokungasebenzi.
FAQ
1. Zeziphi iingenelo ezinikezelwa zii-transformers zangaphandle xa kuthelekiswa neentlobo ngeentlobo zangaphakathi?
Iitransformer zangaphandle ezinokubakho ziyayisusa imfuneko yamagumbi ahlukeneyo etransformer, nto leyo enciphisa iindleko zokwakha kunye neemfuno zezindlu kwiindawo ezinendawo encinci. Izigqubuthelo ezingangeni mozulu ezinereyithingi ye-IP65 okanye ngaphezulu zinokushiywa zivulelekile emvuleni, ekhephini, nakubushushu obugqithisileyo. Ukufakelwa kwe-epoxy resin kungcono ekuthinteleni ukufuma kunoyilo lwangaphakathi oluzaliswe yioyile. Ukufakelwa kungenziwa kwizakhiwo ezikhoyo, ezifana neepali okanye ii-concrete pads, ngaphandle kokwenza umsebenzi omninzi wokwakha. Nangona kunjalo, iiyunithi zangaphandle zifuna ukufakelwa okungcono kunye nokhuseleko ekungcoleni, nto leyo eyenza zibize kakhulu ukuzithenga ekuqaleni xa kuthelekiswa neeyunithi zangaphakathi ezenza umsebenzi ofanayo wombane.
2. Ukuhlolwa kolondolozo kufuneka kwenzeke kangaphi ukuze kujongwe ukusebenza kakuhle kwetransformer?
Iitransformer zangaphandle kufuneka zihlolwe amehlo kube kanye ngonyaka ukuqinisekisa ukuba ikhava iqinile, uqhagamshelo luqinile, kwaye ubushushu bukwimeko entle. Rhoqo emva kweminyaka emibini ukuya kwemithathu, iiskeni zemifanekiso yobushushu zifumana iingxaki zonxibelelwano ngaphambi kokuba zenzeke. Rhoqo emva kweminyaka emi-5, uvavanyo lokumelana nobushushu luqinisekisa ukuba amandla e-dielectric ahlala ngaphakathi kwemida eyamkelekileyo. Ngexesha lokuhlolwa kwemitha yonyaka okanye nanini na xa kukho amaxhala malunga nokuchaneka, i-voltage yesibini yokukhupha kufuneka ihlolwe ngokuchasene nemigangatho elinganisiweyo. Ukulandelela umphezulu kunokuthintelwa ngokucoca ngaphandle kweendawo ezinzima rhoqo emva kweenyanga ezintandathu, njengeendawo zaselunxwemeni ezivezwe emanzini anetyuwa okanye kwiindawo zoshishino ezingcoliswe kakhulu.
3. Ngaba ii-transformers zangaphandle zinokwenziwa ngokwezifiso ukuze zisetyenziswe kwimizi-mveliso enzima?
Iitransformer zangaphandle ezinokubakho zihlala zihlengahlengiswa ngabavelisi ukuze zihlangabezane neemfuno ezithile. Utshintsho luquka ii-voltage zesibini ezingezizo ezisemgangathweni ukuze zisebenze neenkqubo zokulinganisa ezindala, imigama emide yokujikeleza kwiindawo ezinongcoliseko oluninzi, ukuqinisa inyikima kwiindawo ezithandwa ziinyikima, kunye nokuseta okwahlukileyo okunokufaka izitishi ezingaphantsi ezinegumbi elincinci. Kumsebenzi welebhu ochanekileyo, kusetyenziswa iiklasi zokuchaneka ngokwezifiso eziqinileyo kuneeklasi eziqhelekileyo ze-0.2. Iiwindings ezininzi zesibini zivumela ukudityaniswa kweesekethe zokulinganisa kunye nezokhuseleko ngaxeshanye ngelixa zigcina umbane wahlukile. Ukuze uyilo olwenziwe ngokwezifiso luhlangabezane neemfuno zokusebenza, ixesha lokulinda lokuthengwa lide kangangeeveki ezisi-8 ukuya kwezili-12 kuneempahla ezisemgangathweni. Oku kukuvumela ukuqinisekiswa kobunjineli kunye neenkqubo zovavanyo.
Sebenzisana neXi'an Xikai kwizisombululo zoGuquguquko olunokuthenjwa lwangaphandle
Njengomenzi we -transformer yangaphandle onamava obuchwephesha angamashumi amathathu eminyaka, iXi'an Xikai Medium & Low Voltage Electric Co., Ltd. ikulungele ukuxhasa iimfuno zakho zokulinganisa iziseko zombane. I-transformer yethu ye-voltage yangaphandle ye-35kV isebenzisa iteknoloji yokukhusela i-epoxy resin kunye nolawulo oluqinileyo lomgangatho ukunika izitishi ezincinci, izityalo zoshishino, kunye neenethiwekhi zeenkonzo ukuchaneka kokulinganisa kunye nobude bemozulu ababudingayo. Ungathumela i-imeyile kwiqela lethu leengcali ku-serina@xaxd-electric.com , amber@xaxd-electric.com , okanye luna@xaxd-electric.com ukuze uthethe ngeemfuno zesicelo kwaye ufumane iinkcukacha ezihambelana neprojekthi yakho.
Ucaphulo
1. IKhomishini yeHlabathi ye-Electrotechnical. IiTransformers zeZixhobo - Icandelo lesi-2: Iimfuno ezongezelelweyo zeeTransformers zeVoltage. IEC 61869-2: Umgangatho we-2012.
2. I-IEEE Power and Energy Society. Isikhokelo se-IEEE sezicelo zokudluliselwa kwezithuthi ezikhuselekileyo kwiintambo zothumelo. Umgangatho we-IEEE C37.113-2015.
3. UMbutho weSizwe waBavelisi boMbane. Iimfuneko zeZiguquli zeZixhobo. Umgangatho we-ANSI C57.13-2016.
4. Kulkarni, SV, kunye noKhaparde, SA Ubunjineli boTshintsho: Uyilo, iTekhnoloji, kunye noDiagnostics. CRC Press, Uhlelo lwesi-2, 2017.
5. Iqela le-ABB. Ii-Voltage Transformers: Isikhokelo seSicelo soKhuselo kunye nokuMitha. Ushicilelo loBugcisa, 2019.
6. IZiko loPhando lwaMandla oMbane. Uvavanyo lweeNdawo zeeTransformers zeZixhobo: Iindlela eziBalaseleyo kunye neendlela zokuxilonga. Ingxelo ye-EPRI 3002015591, 2020.
