Iitransformer zamandla angaphakathi ziyinxalenye ebalulekileyo yeenkqubo zokusasazwa kombane kuba zitshintsha ii-high primary currents zibe yi-low secondary currents ezinokusetyenziswa ziimitha kunye neeswitshi zokhuseleko. Iingcali zinokujonga ukuhamba kombane ngaphandle kokuchukumisa iingcingo ze-high-voltage ngokuthe ngqo kuba ezi zixhobo zokulinganisa zisebenzisa i-electromagnetic induction. Iindawo ezininzi, ukusuka kwimizi-mveliso ukuya kwizibhedlele, zixhomekeke kwezi transformers ukugcina imisebenzi ibonakala kwaye zigcine abasebenzi bekhuselekile. Ukwazi indlela ezisebenza ngayo, oko zifuna ukufakwa, kunye nendlela yokuzikhetha kunceda amaqela athengayo ukuba enze ukhetho olukrelekrele olunefuthe ngqo kuzinzo lwenkqubo kunye nolawulo lwamandla.

Ukuqonda iiTransformers zangoku zangaphakathi

Imigaqo-siseko yokusebenza kunye neenxalenye

I-transformer yangaphakathi inamacandelo amathathu aphambili: i-conductor ephambili ephethe i-full load current, i-magnetic core channeling flux, kunye ne-secondary windings ezisa i-low current kwizixhobo. I-primary current idala i-magnetic field ebangela i-proportional secondary current ngokusekelwe kumlinganiselo wokujika. Uyilo lwe-wound-core lubonelela ngokuchaneka kwengeniso yokulinganisa. Uyilo lwe-Bar-type lwenza kube lula ukufaka ngemingxuma yokudlula. Iinguqulelo ze-split-core zibamba iingcingo ezikhoyo ngaphandle kokuqhawulwa, zilungele ukulungiswa kwakhona.

Ukuhlelwa ngokuchanekileyo kunye neMigangatho yokuSebenza

I-IEC 61869 ichaza iiklasi zokuchaneka ezichaza imida yeempazamo zomlinganiselo phantsi kweemeko ezahlukeneyo zomthwalo. Iitransformer zeKlasi 0.2 zivumela ukuhlawuliswa kwamandla ngokuchanekileyo. Iiyunithi zomgangatho wokhuseleko ezinezilinganiso ze-5P okanye ze-10P ziqinisekisa ukufunyanwa kweempazamo ngokuchanekileyo. Ukuhambelana kwamaza okusebenza—60Hz kwiinkqubo zase-US, 50Hz kwiiprojekthi zamazwe ngamazwe—kufuneka kuqwalaselwe. Iiyunithi zetransformer zangaphakathi ezilinganiswe kabini ziphatha amaza omabini. Umthamo womthwalo kufuneka uhambelane nezixhobo ezixhunyiweyo ukuze kulinganiswe ngokuchanekileyo. Ukukhetha udidi olufanelekileyo kuthintela iimpazamo zokuhlawuliswa okanye ukungasebenzi kakuhle kokhuseleko.

Ukwahluka koYilo oluKhethekileyo lwesicelo

Iiyunithi ze-transformer zangaphakathi zesigaba esinye zikhonza umqhubi ngamnye kwiinkqubo zokusasazwa kweengcingo ezintathu. Iinguqulelo zesigaba ezintathu zijonga imithwalo elinganisiweyo kulwakhiwo oludibeneyo. Izixhobo ezinemithwalo enzima yeemoto ziyazuza ekujongeni imiqathango yesigaba ezintathu ezibona ukungalingani okubonisa iingxaki zoomatshini okanye zombane. Amaziko edatha asebenzisa uyilo lwamandla angafunekiyo afuna ukubekwa iliso kwesigaba ngasinye. I-Epoxy resin casting ihlanganisa ngokupheleleyo izinto zangaphakathi kwiiyunithi ze-35kV, ibonelela ngokhuseleko lokufuma kunye nokususa iintambo eziphilayo ezibonakalayo, inciphisa umngcipheko we-arc flash ngexesha lokugcinwa.

Ukufakwa kunye nokugcinwa kweeTransformers zangoku zangaphakathi

Iimfuneko zoCwangciso lwangaphambi koFakelo kunye noKhuseleko

Amaqela obunjineli kufuneka aqinisekise iimfuno ze-voltage, i-frequency, kunye ne-current ngaphambi kokuba kuthengwe i -transformer yangaphakathi. Iintlobo ze-35kV zisebenza kwiinkqubo ze-50/60Hz ezine-currents eziphambili ukusuka kwi-20A ukuya kwi-2500A. Iziphumo zesibini yi-1A okanye i-5A—5A ekhethwayo kwi-long wire runs enciphisa ukuhla kwe-voltage. Ukuthobela kwe-GB 20840.2-2014 kunye ne-IEC 61869 kuqinisekisa ukwamkelwa kwekhowudi yamazwe ngamazwe. Uyilo oluncinci olulungiselelwe indawo encinci yeswitchgear lunciphisa iinyawo zephaneli ngelixa lugcina isithuba sesigaba, lunciphisa ixesha lokufaka nge-30%.

Iinkqubo zokuFakela iNyathelo ngeNyathelo

Iingcali kufuneka ziqinisekise ukuba ii-conductors eziphambili zidlula kwimingxuma ephambili ngaphandle kokugoba okubukhali okuxinzelela iingcingo. Uqhagamshelo lwesibini lufuna uqhoboshelo olukhuselekileyo lwesiphelo oluqinisekisa iimpawu ze-polarity ukuze kubekho ubudlelwane obuchanekileyo besigaba. I-polarity engasemva ibangela iimpazamo zemitha okanye ukungasebenzi kakuhle kwereyila. I-torque efanelekileyo ithintela uqhagamshelo olukhululekileyo olubangela ukufudumeza. Iinkqubo zokutshixa/ukuthega zithintela umbane ngengozi. Ukubeka umhlaba kwisiphelo sesibini esinye kuthintela ukwakheka kwe-voltage eyingozi ukuba i-insulation yokuqala ayisebenzi. Ungaze usebenzise i -transformer yangaphakathi enesekethe yesibini evulekileyo—ii-voltage spikes zinokwenzakalisa abasebenzi.

IiProtocols zoLondolozo lwesiqhelo kunye nokusombulula iingxaki

Ukuhlolwa okubonakalayo kuchonga umonakalo obonakalayo, ukutsha, okanye ukungena komswakama okubonisa ukusilela kwetywina. Imifanekiso yobushushu ibona ukunyuka kobushushu okubonisa unxibelelwano olukhululekileyo okanye iingxaki zangaphakathi ngaphambi kokusilela okukhulu. Izifundo zemilinganiselo zithelekisa imisinga ephambili neyesibini phantsi kweemeko ezilawulwayo. Uvavanyo lokumelana nobushushu olusebenzisa iimitha ze-megohm luqinisekisa ukuba umswakama awutshintshanga iimpawu. Uvavanyo lokukhupha okuncinci ngaphantsi kwe-10pC lufumanisa ukonakala kobushushu obuqalayo. Ukusilela okuqhelekileyo kubandakanya ukushukuma komlinganiselo ovela kwii-cores ezindala kunye nokubola kobushushu obuvela kwimijikelezo yobushushu. Ukugcinwa kwangaphambili kwenza ukuba kutshintshwe okucwangcisiweyo.

IiTransformers zangaphakathi kunye nezangaphandle: Uthelekiso oluneenkcukacha

Ukhuseleko lweNdalo kunye nomahluko kwiZakhiwo

Uxinzelelo lwendalo olujongene neetransformer zangaphakathi ngexesha lokusebenza luxhomekeke kwindawo ezikuyo. Xa zifakwe ngaphakathi, iimeko ziyalawulwa, ngotshintsho oluncinci kubushushu, ukudibana okuncinci nokufuma, kunye nokhuseleko kwimitha ye-UV. Ezi meko zikhuselekileyo zenza kube nokwenzeka ukwakha izinto ezikhaphukhaphu kwaye zinezikhewu ezilula, nto leyo enciphisa iindleko zezinto. Iiyunithi zangaphandle zifuna izindlu ezimelana namanzi kunye nokukhanya kwe-UV, kunye nokuvalwa okungcono kwimvula kunye nekhephu. Umgangatho wokhuseleko lwendawo ebiyelweyo—ngokuqhelekileyo i-IP54 okanye ngaphezulu yokusetyenziswa ngaphandle—wongeza ubunzima kunye neendleko kodwa kuyimfuneko kwiindawo ezivulelekileyo kwiimeko zemozulu.

Ukukhethwa kwezinto kusekelwe kwinto efunekayo kwindawo engqongileyo. Iifomyula ze-epoxy eziqhelekileyo zisetyenziswa kwiitransformer zangaphakathi ukuze ziqine kwaye zibe zilungile ekuqhubeni umbane. Izongezo ezisetyenziswa kuyilo lwangaphandle zikhusela ekonakaleni kwe-UV kunye nokujikeleza kobushushu kumanqanaba obushushu abanzi. Iitanki zesiphelo kwiiyunithi zangaphandle zinemingxuma yokukhupha amanzi kunye neenkqubo zokuphefumla ezithintela ukufuma ukuba kungaqokeleli. Xa kuthelekiswa nezinye zangaphakathi, olu phuculo loyilo lwenza imveliso ibe nzima ngakumbi kwaye lunyuse iindleko ngeyunithi nganye.

Iimpawu Zokusebenza kunye Neemfuno Zokugcinwa

Iiyunithi ze-transformer zangaphakathi nezangaphandle zibonelela ngeeklasi ezahlukeneyo zokuchaneka. Ukuchaneka kweKlasi 0.2 kuhambelana nokulinganisa ingeniso yangaphakathi. Ukuchaneka kweKlasi 0.5 kuqhelekile kwiiyunithi zangaphandle ngenxa yemingeni yokusingqongileyo. Ii-transformer zangaphakathi zigcina ii-coefficients zobushushu eziqinileyo ezisebenza kumanqanaba amancinci obushushu. Iiyunithi zangaphakathi zihlala zifuna ukuhlolwa konyaka; iiyunithi zangaphandle zifuna ukuhlolwa kwesiqingatha sonyaka ukuze zibone ukuguguleka okunxulumene nemozulu. Izixhobo zangaphakathi ziqokelela uthuli olufuna ukusulwa ngamanye amaxesha; iiyunithi zangaphandle ziqokelela ungcoliseko olufuna ukucocwa kwe-solvent ukuthintela ukulandelwa kwe-insulator.

Uhlalutyo lweendleko kunye neMithetho yokuKhetha

Iiyunithi ze-transformer zangaphakathi zibiza ngaphantsi ngama-20-30% kuneeyunithi zangaphandle ekuqaleni ngenxa yokwakha okulula kunye nezixhobo ezisemgangathweni. Iiyunithi zangaphakathi zifuna umsebenzi omncinci wokufakela kuba zincinci kwaye kulula ukuziphatha. Ixabiso lilonke lobunini kufuneka liqwalasele ukulingana kwesicelo—ukufaka i-transformer yangaphakathi ngaphandle kubangela ukungaphumeleli kwangethuba okubiza ngaphezulu kakhulu kunokonga kokuqala. Iimeko zendawo zimisela ukhetho: amagumbi e-switchgear agqunyiweyo afuna izixhobo ezilinganiswe ngaphakathi; izitishi ze-transmission zifuna iiyunithi ezimelana nemozulu. Izibonelelo ze-hybrid zifuna ukuthelekiswa kwexabiso elifanelekileyo lejenereyitha kwindawo nganye yokufaka.

Ingcaciso yeMarike kunye neSikhokelo sokuThenga iiTransformers zangoku zangaphakathi

Abavelisi Abaphambili kunye noKwahluka kweMveliso

Kwimarike yehlabathi, kukho iinkampani ezaziwayo ezigxile kwizinto ezahlukeneyo kwaye zinamandla kwiindawo ezithile. I-Siemens inoluhlu olubanzi lweemveliso, igxile kwimigangatho yoyilo yaseYurophu kunye nokukwazi ukudibanisa ubuchwepheshe bedijithali. I-ABB ineendlela zokukhetha zombini amanqanaba okusasaza kunye nokuhambisa, kodwa iinkqubo zabo ze-switchgear zemodyuli zilapho zikhanya khona ngokwenene. I-Schneider Electric isebenza kakhulu nee-transformers zangoku ezisebenza nezixhobo zolawulo lwamandla zokwakha oomatshini. Ngeempahla ezihlangabezana nemigangatho ye-IEEE, i-General Electric inendawo eqinileyo kwiimarike zeenkonzo eMntla Melika.

I-Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. ibisenza ii- indoor current transformers kangangeminyaka engamashumi amathathu. Umgca wethu wemveliso uquka uluhlu lwamanqanaba ombane, uyilo oluphambili, kunye namanqanaba okuchaneka ukuhlangabezana neemfuno zamashishini amaninzi. Ii-bus-type transformers kumgca we-LMZB zisebenzisa iteknoloji yokufakelwa kwe-casting ukubonelela ngokusebenza okuthembekileyo kwizikhululo, iifektri, kunye nezakhiwo zoshishino. Iinkqubo zophando zesizwe zincede ekwakheni izakhono zobugcisa ezenza kube nokwenzeka ukutshintsha ii-ratios, iziphumo ezongezelelweyo, kunye noqwalaselo lwe-enclosure ukuze zihambelane neemfuno zeprojekthi ethile.

Iikhrayitheriya zoVavanyo lweeNkcukacha zoBugcisa

Uvavanyo lwangaphakathi lwamandla ombane oluphambili kufuneka lulungele imithwalo eqikelelweyo kunye nokukhula kwexesha elizayo—i-transformer ye-1000A iphatha imithwalo ye-600–800A ene-expansion margin. Ukhetho lwesibini lwemveliso (1A vs 5A) luxhomekeke kubude bokusebenza kwentambo; ukubaleka ixesha elide kuthanda uphononongo lwe-1A kunciphisa ukulahleka kokwehla kwevolthi. Iibhalansi zeklasi yokuchaneka zixabisa ngokuchasene nokuchaneka kokulinganisa: Udidi lwe-0.2 okanye lwe-0.5 luyimfuneko ekulinganiseni ingeniso nangona iindleko ziphezulu; Iiklasi ze-5P okanye ze-10P zisebenza ngokufanelekileyo kwizicelo zokhuseleko. Iiyunithi ezidibeneyo zidibanisa ii-metering kunye nee-cores zokukhusela kwindibano enye, zigcina indawo yepaneli.

UBuchule bokuThengwa kweeMpahla kunye noLawulo lwesiXokelelwano soBonelelo

Iindlela ezahlukeneyo zokufumana izinto zisetyenziswa ngokuxhomekeke kubukhulu nobude bomsebenzi. Unxibelelwano oluthe ngqo nomenzi, oluvumela ukwenziwa ngokwezifiso kunye nokonga okukhulu, lulungile kwiifektri ezinkulu. Iiprojekthi ezincinci zinokukwazi ukusebenzisa iinethiwekhi zokusasaza ukuze zifumane iimpahla eziqhelekileyo ngokukhawuleza. Ukuze ulungelelanise ezi ndawo zokuthengisa, kufuneka wazi malunga namaxesha okulinda. Kwizinto ezikwisitokhwe, zithunyelwa ngaphakathi kweeveki, kodwa ulungiselelo oluqhelekileyo luthatha iiveki ezisi-8 ukuya kwezili-12 ukuze lwenziwe.

Xa uthenga into kwamanye amazwe, kufuneka ucinge ngezothutho, ezinokutshintsha ixabiso lilonke. Kwintengiso enkulu, ukuthunyelwa kweekhonteyina yeyona ndlela ingabizi kakhulu yokuzifikisa apho ziya khona, ngelixa ukuthunyelwa ngenqwelomoya kubiza ngaphezulu kwiimfuno ezingxamisekileyo. Amazwe ahlukeneyo aneerhafu ezahlukeneyo zokungenisa impahla kunye neenkqubo zokususa impahla, nto leyo eyenza izinto zibe nzima ngakumbi kwaye ifuna abathumeli bempahla abanamava. Xa kuxoxwa ngemigaqo yokuhlawula, ii-odolo zexesha elide kufuneka zikhuselwe kwimingcipheko yokuguquguquka kwemali ngokusebenzisa amaxabiso amiselweyo okanye izivumelwano zorhwebo.

Imithetho yokuqinisekisa umgangatho ikhusela abathengi ekubeni bafumane izixhobo ezaphukileyo. Ukuba neerekhodi zovavanyo lwefektri ezinomlinganiselo wokuchaneka komlinganiselo, ukumelana nobushushu, kunye nokukhutshwa okungaphelelanga kusinika indawo yokuqala yokuqonda indlela esebenza kakuhle ngayo imveliso. Iinkonzo zokuhlola zomntu wesithathu zijonga umgangatho wenkqubo yemveliso ngaphambi kokuba ithunyelwe. Oku kuluncedo ngakumbi kubathengi abangazi nto ingako ngomboneleli. Imigaqo yewaranti kufuneka igubungele zombini iingxaki ngendlela eyenziwe ngayo imveliso kunye nezithembiso zokusebenza kakuhle, kunye neendlela ezicacileyo zokulungisa iimveliso ezingahlangabezani nemigangatho.

Iingenelo kunye neeNdlela zeXesha elizayo zeeTransformers zangoku zangaphakathi

Iingenelo Eziphambili Zokuqhuba Ukwamkelwa Kwabanye

Eyona nzuzo iphambili eziziswa zii-indoor current transformers kwiisekethe zombane kukuba zizenza zikhuseleke ngakumbi. Ngokugcina iisekethe zokulinganisa kude neengcingo ze-voltage ephezulu, ezi zixhobo zigcina abasebenzi bengadibani ngqo nombane ngexesha lemisebenzi eqhelekileyo. Iingcali zinokufikelela kwiisekethe zesibini ezisebenza kumanqanaba e-voltage akhuselekileyo, nto leyo enciphisa kakhulu umngcipheko we-arc flash kunye ne-electrocution. Uyilo lwanamhlanje lusebenzisa i-epoxy resin ukwenza ezi ndawo zikhuseleke ngakumbi ngokuzivalela ngokupheleleyo ukuze zingadibani nezinye iindawo ngempazamo.

Amaxabiso anyukayo ezindlu ezithengiswayo zeswitchgear anokujongwana nawo ngolawulo lwesithuba. Endaweni yokuchitha imali eninzi ekuphuculeni izakhiwo ezibizayo, uyilo oluncinci luvumela izixhobo ezingaphezulu ukuba zingene kwiiphaneli ezisele zinobukhulu obufanelekileyo. Ukudibanisa nezitshintshi zokukhusela zedijithali kunye nabavavanyi bomgangatho wamandla kudibanisa imisebenzi yokulandelela eyayifuna izixhobo ezahlukeneyo zibe yinto enye. Oku kwenza ukuba iingcingo zibe lula, kwenza ukusombulula iingxaki kube lula, kwaye kwenza inkqubo ithembeke ngakumbi ngokunciphisa inani leendawo zokudibanisa.

Ubuchwephesha obusakhulayo kunye neMikhombandlela yokuQala

Ukuhlanganiswa kwedijithali yeyona ndlela ibalulekileyo etshintsha indlela uyilo lwangoku lwe-transformer olutshintsha ngayo. Ngee-transformers ezikrelekrele ezineekhompyutha ezakhelwe ngaphakathi, akufuneki udlule nawaphi na amanyathelo ukusuka kwi-analog ukuya kwidijithali. Iiprotokholi ze-IEC 61850 zivumela ezi zixhobo ukuba zithethe zodwa. Ezi protokholi ziyindlela entsha yokwenza izinto ngokuzenzekelayo kwisitishi esincinci kwaye zivumela unxibelelwano lwe-plug-and-play phakathi kwabenzi. Iziphumo zedijithali zenza imilinganiselo ichaneke ngakumbi kwaye yenze kube lula ukuqhagamshela kwiinethiwekhi zolawulo lwemizi-mveliso kunye neenkqubo zolawulo lwezakhiwo.

Uqhagamshelo lwe-IoT luvumela ukulandelela kudlule imida yezikhululo ezisezantsi. Iitransformer ezibotshelelwe kwilifu zithumela idatha yokusebenza kumaqonga aphakathi, akuvumela ukuba ubone okwenzekayo kuzo zonke iisayithi zakho nangaliphi na ixesha. Ukusebenzisa uhlalutyo lokuqikelela kule datha ukufumana iindlela zokuwohloka ezibonisa xa into iza konakala kuvumela ukulungiswa kwangaphambili. Uvavanyo olukude lunciphisa isidingo sokutyelela indawo, nto leyo enciphisa iindleko zokugcinwa kwaye ikhawulezise ixesha elithathayo ukulungisa iingxaki njengoko zivela. Ukufunyanwa okutsha kwisayensi yezinto ezibonakalayo kubonisa ukusebenza ngcono kunye nobomi obude. Izinto ezisisiseko ze-nanocrystalline zinciphisa ilahleko ngelixa zigcina ubungakanani besakhiwo buncinci. Oku kwenza uyilo olusebenzisa amandla lusebenze ngakumbi. Imicimbi yokusingqongileyo ekupheleni kobomi inokujongwa ngeefomyula ze-epoxy ezinokuphinda zisetyenziswe, kwaye izinto ezizinzileyo zidlala indima ekukhetheni ukuthenga. Izinto zokudibanisa ezingenalo i-lead zihambelana nemithetho ye-RoHS echaphazela iimarike zaseYurophu kwaye zisetyenziswa ngakumbi kwihlabathi liphela.

Ukuguquka kweMigangatho yoShishino kunye nokuThotyelwa kweMithetho

Amaqela emigangatho ahlala etshintsha imithetho ukuze ahambisane netekhnoloji entsha kunye nezifundo zokhuseleko. Uthotho lwe-IEC 61869 ludibanisa imigangatho eyahlukeneyo eyayikho ngaphambili kwiitransformer zangoku kunye neze-voltage. Oku kwenza kube lula ukujonga ukuba ziyalandelwa na. Ukuhambelana phakathi kwemigangatho ye-IEC kunye ne-IEEE kunciphisa umahluko kwiinkcukacha zengingqi, okwenza kube lula ukuthenga izinto kwamanye amazwe. Kwiinguqu ezizayo, imithetho yokhuseleko lwe-cyber elungisa ubuthathaka kwiitransformer zedijithali iya kongezwa kuba uqhagamshelo lwenza iindawo zohlaselo zibe nkulu.

Imithetho yokusingqongileyo ichaphazela indlela eyenziwa ngayo imveliso kunye nezinto ezisetyenziswayo. Imithetho yokonga amandla ikhuthaza uyilo olunelahleko ephantsi, nto leyo enciphisa amandla alahlekayo. Imida kwizinto eziyingozi isusa izinto eziyingozi kwiindlela zemveliso kunye neempahla ezivelisiweyo. Imithetho yokulahla izinto ezingafunekiyo inyanzelisa iindlela zoyilo-lokuqhaqha ezenza kube lula ukuqokelela iindawo. Abavelisi abasabela ngokukhawuleza kwezi ndlela baya kuba kwimeko entle njengoko imithetho iba ngqongqo.

isiphelo

Iitransformer zamandla angaphakathi ziyindlela yokulinganisa eqinisekisa ukuba umbane usasazwa ngokukhuselekileyo nangokufanelekileyo kumashishini nakwiifektri. Ngokwazi indlela ezisebenza ngayo, indlela yokuzifaka, kunye nendlela yokuzikhetha, amaqela athengayo anokukhetha izixhobo ezihlangabezana neemfuno zenkqubo ngelixa egcina iindleko ziphantsi kangangoko. Kukho umahluko phakathi koyilo lwangaphakathi nolwangaphandle, iiklasi zokuchaneka, kunye neentlobo zezakhiwo ekufuneka zilinganiswe ngononophelo ngokweemeko zesicelo. Ubuchwepheshe obutsha bedijithali kunye nemizamo yokuba nobuhlobo nokusingqongileyo itshintsha indlela esebenza ngayo imveliso, iyenza ibe luncedo ngakumbi kwaye ibe ngcono ebomini bayo bonke. Ubudlelwane obucwangcisiweyo nababoneleli ababonelela ngenkxaso yobuchwephesha, ukukwazi ukwenza utshintsho, kunye nokuhanjiswa okuthembekileyo kunceda ukuqinisekisa ukuba iiprojekthi ziyaphumelela kwaye iinjongo zoshishino zexesha elide ziyafezekiswa.

FAQ

1. Ngowuphi umgangatho ophambili wangoku ekufuneka ndiwuchaze kwisicelo sam?

Khetha inani elingaphakathi kwe-25% yomda womthwalo wakho ophezulu oqikelelweyo. Isakhiwo esisebenzisa i-800A peak singazuza kwi-transformer enokusingatha i-1000A. Xa umthwalo uphantsi, ukwenza ubungakanani obugqithisileyo kwenza inkqubo ingachaneki, kwaye xa umthwalo uphezulu, ukwenza ubungakanani obungaphantsi kunokubangela ukuba igcwale. Olu khetho kufuneka lusekelwe kuqikelelo lokukhula komthwalo, kuba ukutshintsha ii-transformer akulunganga kwaye kubiza imali eninzi.

2. Ukukhethwa kweklasi yokuchaneka kuzichaphazela njani iindleko zokusebenza?

Iiklasi ezikumgangatho ophezulu zibiza kakhulu ekuqaleni, kodwa zibonelela ngemilinganiselo echanekileyo ngakumbi. Kwimilinganiselo yengeniso, ii-transformers zeKlasi 0.2 ziyimfuneko kuba zibonelela ngeendleko ezichanekileyo ngakumbi kunye nezikhalazo eziphantsi zeenkonzo. Ngeenjongo zokukhusela, iiyunithi zeKlasi 5P okanye ze-10P zilungile ekufumaneni iimpazamo. Ukhetho lulinganisa iindleko zokuthenga izixhobo kwangaphambili xa kuthelekiswa neenzuzo zemilinganiselo engcono kwixesha elide.

3. Ngaba ii-transformers zingafakwa ngaphandle kokunciphisa amandla eesekethe?

Ngeedizayini ze-split-core, umsebenzi ungenziwa ujikeleze iintambo ezibukhoma ngelixa ulandela imithetho engqongqo yokhuseleko. Kodwa ukususwa kwamandla kwisekethe kusafuneka kwiikhonkco zesiphelo ukuze kumiswe iingozi ze-arc flash. Xa ufaka ii-transformers eziqhelekileyo ze-wound-core kunye ne-bar-type, yonke isekethe kufuneka icinywe. Ukususwa kwamandla kudla ngokufunwa yimithetho yokhuseleko kunye nemigaqo-nkqubo ye-inshorensi, nokuba loluphi uhlobo lwejenereyitha.

Sebenzisana neXi'an Xikai kwizisombululo zeTransformer zangoku ezithembekileyo

Ngamava eminyaka engama-30 kweli candelo kunye nobuchwepheshe obahlukeneyo, uXi'an Xikai ungumntu obalaseleyo ekwenzeni ii-transformers zamandla ombane eziphakathi. Uthotho lwethu lwe-transformer zamandla ombane zangaphakathi ezingama-35kV zenziwe nge-epoxy resin kwaye ziyahlangabezana nemigangatho ebekwe yi-GB 20840.2-2014 kunye ne-IEC 61869. Ikwachanekile ngaphakathi kweklasi ye-0.2. Ukukwazi ukwenza izinto kuthetha ukuba ii-ratios, iziphumo ezongezelelweyo, kunye noqwalaselo lwesikhongozeli zinokutshintshwa ukuze zihambelane neemfuno zeprojekthi nganye. Iiprotokholi zokuqinisekisa umgangatho, ezinje ngovavanyo oluqhelekileyo lwe-100%, ziqinisekisa ukuba ukusebenza kuhlala kufana kwaye kuyahlangabezana neemfuno zokusetyenziswa okunzima kushishino. Njengenkampani eyenza ii-transformers zamandla ombane zangaphakathi kwiimarike kwihlabathi liphela, sinikezela ngenkxaso yobuchwephesha ngexesha locwangciso, ukufakelwa, kunye nokusetyenziswa kwamanqanaba. Nxibelelana neqela lethu lobunjineli ku-serina@xaxd-electric.com , amber@xaxd-electric.com , okanye luna@xaxd-electric.com ukuze uthethe ngeemfuno zakho zangoku zedatha kwaye ufumane izisombululo ezenzelwe indawo yakho.

Ucaphulo

1. IKhomishini yeHlabathi ye-Electrotechnical. "IiTransformers zeZixhobo - Icandelo lesi-2: Iimfuno ezongezelelweyo zeeTransformers zangoku." IEC 61869-2:2012 Uxwebhu oluQhelekileyo, eGeneva, eSwitzerland.

2. UZhang, uWei kunye noLiu, uXiaong. "Uhlalutyo Lokusebenza lwee-Epoxy-Resin Cast Current Transformers kwi-Medium-Voltage Applications." I-IEEE Transactions on Power Delivery, uMqulu 34, Inombolo 3, iphe. 1245-1253, 2019.

3. UMbutho weSizwe waBavelisi boMbane. "Imigangatho yeeTransformers zeZixhobo: Iimpawu zokusebenza kunye neenkqubo zoVavanyo." I-NEMA Publication C93.1-2018, eRosslyn, eVirginia.

4. Anderson, Paul M. "Ukhuseleko lweNkqubo yaMandla." Uthotho lweeNkcukacha ze-IEEE kwiNjineli yaMandla, iWiley-Interscience, Uhlelo lwesine, iphe. 287-342, 2022.

5. Chen, David kunye noKumar, Rajesh. "Ukuhlanganiswa kweSmart Grid yeeDijithali zangoku eziGuquliweyo: Imingeni kunye namathuba." Ijenali yoBunjineli boMbane kunye neTekhnoloji, uMqulu 16, No. 4, iphe. 1789-1801, 2021.

6. Blackburn, J. Lewis kunye noDomin, Thomas J. "Ukukhusela Ukudluliselwa: Imigaqo kunye noSetyenziso." CRC Press, Taylor & Francis Group, Uhlelo Lwesine, Isahluko 6: IiTransformers zeZixhobo, iphe. 173-218, 2020.

thumela