Izithinteli zombane zithintela ukunyuka kwamandla ombane kwimibane kunye nokunyuka kwamandla ombane. Yi-insulator ngokuzenzekelayo, kodwa xa amandla ombane edlula amanqanaba akhuselekileyo, ukumelana kwawo kuyehla ngoko nangoko ukuze kudluliselwe amandla anobungozi emhlabeni. Le ndlela ibalulekileyo ikhusela izixhobo ezibizayo kunye nokuthembeka kwenethiwekhi yamandla.

ukubanjwa kwambane

Yintoni i-Lightning Arrester?

Umsebenzi kunye nendima

Izithinteli zombane zibalulekile kwiziseko zombane zanamhlanje. Ezi zixhobo zintsonkothileyo ziyindlela yokuqala yokuzikhusela kwiziganeko zombane ogqithisileyo obangelwa kukuqhekeka kwamandla. Izithinteli zombane zizitshintshi ezikrelekrele ezisebenza xa amanqanaba ombane ayingozi esongela izixhobo zombane.

Izikhankanyi Technical

Izixhobo ezikhethekileyo, uninzi lwazo zii-varistors ze-zinc oxide, zinika isixhobo iimpawu zombane ezikhethekileyo. Ezi zinto zinokumelana okuphezulu kakhulu phantsi kombane oqhelekileyo osebenzayo, nto leyo eyenza zingabonakali kwinkqubo yombane. Impendulo yombane engangqalanga yanamhlanje yee-arrester intle. Ukusebenza kombane kunye nokutshintsha kubangela ukunyuka kombane okunciphisa ukumelana kombane kwimizuzwana emincinci. Le mpendulo ikhawulezileyo idala indlela yomhlaba enganyangekiyo kakhulu, ijika amandla ayingozi kwizixhobo ezibuthathaka.

Iinzuzo zeZiko leMizi-mveliso

Ngenxa yokuba zifuna umbane othembekileyo, izakhiwo zoshishino ziyazuza kolu khuseleko. Iifektri zokwenza izinto ezifumana izigidi zeerandi azikwazi ukuhlawula ukusilela kwezixhobo ezinxulumene nokuphazamiseka kombane. Amaziko edatha agcina iinkqubo zolwazi ezibalulekileyo afuna ukhuseleko oluqhubekayo kwiingxaki zombane ezinokucima idatha.

Ubunjineli kunye neSayensi yeZixhobo Inkqubela phambili

Ubunjineli bezi zixhobo bukhula ngesayensi yezinto kunye nophuhliso lwemveliso. Ii-polymer housings kwizixhobo zanamhlanje ziyamelana nokonakaliswa kwendalo kwaye zinika amandla angcono oomatshini kune-porcelain.

Ingxaki Eyisombululayo

Umngcipheko Wokugqithisa Amandla

Iziganeko zombane ogqithisileyo zenzeka rhoqo kwaye zinokutshabalalisa izigidi zeerandi zezixhobo ngemizuzwana. Ukubetha kombane kuthumela amandla amakhulu kwiintambo zombane ngesantya esiphezulu, kufuna ukumelana okuphantsi komhlaba. Ngaphandle kokhuseleko, la mandla atshabalalisa ii-transformers, ii-circuit breakers, kunye nee-elektroniki ezinobuthathaka.

Imiphumo kwiZibonelelo zoMveliso

Izakhiwo zokwenza imveliso zichaphazeleka kakhulu kukunyuka kwamandla ombane. Abalawuli be-logic abacwangcisiweyo, ii-variable frequency drives, kunye neenkqubo zokubeka esweni ezisebenzisa ikhompyutha zenza imigca yemveliso ibe sesichengeni se-transient voltages. Ukubetha kombane kube kanye kunokuvala imveliso, nto leyo ebiza imali, ixesha, kunye nobudlelwane nabathengi.

Impembelelo yeNkqubo zeZibhedlele ezibalulekileyo

Esinye isicelo esibalulekileyo apho umgangatho wamandla uchaphazela ukhuseleko lwabantu zizibhedlele. Oomatshini be-MRI, ii-ventilators, kunye neenkqubo zokubeka esweni izigulane zifuna amandla azinzileyo. Ukuphazamiseka kwe-voltage kunokubangela ukungasebenzi kakuhle kwezixhobo zenkqubo ebalulekileyo, nto leyo ebeka ubomi bezigulane esichengeni.

Imingeni yeNkampani yeNkonzo

Iinkampani zeenkonzo zikagesi ziyasokola ukuzinza kwegridi kwiinethiwekhi ezinkulu zothumelo. Ukutshintsha imisebenzi, iimpazamo, kunye nemozulu kuyaqhubeka nokubeka emngciphekweni ukuthembeka kwenkqubo. Ukucima ngakunye kubiza iinkonzo ingeniso ebalulekileyo kwaye konakalisa ukuthembeka kwazo.

Impembelelo Enkulu Yezemali

Iindleko zokutshintshwa kwezixhobo azikho zodwa ezichaphazela imali. Ukuphazamiseka kweshishini, ukulahleka kwemveliso, kunye nokulungiswa okungxamisekileyo kwenza ukhuseleko olunganeleyo lokugutyungelwa kwezixhobo lube neendleko eziphantsi. Emva kwesiganeko esinye esikhulu se-voltage, iinkqubo zokukhusela ukugutyungelwa kwezixhobo ezifakwe ngokufanelekileyo zizihlawulela ngokwazo iindleko zokungasebenzi kunye neendleko zokutshintshwa kwezixhobo, ngokutsho kwezifundo.

Ubuthathaka benkqubo yombane yanamhlanje buyaqhubeka

Iinkqubo zombane zanamhlanje zinovelwano ngakumbi kwiinguqu ze-voltage njengoko ukwenziwa kwedijithali kuhambela phambili. Ubuchwepheshe be-smart grid, ukuhlanganiswa kwamandla avuselelekayo, kunye nokuzisebenzela ngokuzenzekelayo kwemizi-mveliso kudala ubuthathaka obutsha obufuna ukhuseleko oluphambili.

Iimpawu eziphambili kunye nokusebenza kwe-Deep Dive

Iimpawu eziPhambili ze-Modern Lightning Arresters

Izixhobo zokuthintela umbane zanamhlanje zineempawu ezininzi eziphambili ezizahlula kwizixhobo zokukhusela umbane. Ezi nkqubo zisebenzisa iidiski ze-zinc oxide ezilandelelanayo ukuze zifezekise iimpawu ezichanekileyo ze-voltage-current zisebenzisa itekhnoloji ye-metal oxide varistor.

Ukumelana okungekho ngqo

Umsebenzi obalulekileyo wezithinteli zombane zanamhlanje kukungaxhathisi ngendlela ethe ngqo. Umsinga ovuzayo uhlala ungaphantsi kwe-milliampere enye phantsi kombane oqhelekileyo. Lo msinga ophantsi ugcina isithinteli sikulungele ukukhuselwa ngaphandle kokuphazamisana nokusebenza kwenkqubo.

Impendulo ekhawulezayo yombane

I-Overvoltage inciphisa ngokukhawuleza ukumelana ne-varistor, ivumela ukuhamba komsinga omkhulu emhlabeni. Le mpendulo ye-nanosecond ikhusela kwiingxaki ezininzi zombane ngaphambi kokuba zifikelele kwizixhobo ezixhunyiweyo. I-arrester iqhuba ide i-voltage iqheleke, ize ibuyele ngokuzenzekelayo kukumelana okuphezulu.

Iindlela zokhuseleko ezikwimeko egqithisileyo

Kwiimeko ezinzima kakhulu, iindlela zokunciphisa uxinzelelo zongeza ukhuseleko. Umoya olawulwayo uthintela ukungaphumeleli kokuqhuma okunokwenzakalisa abasebenzi okanye izixhobo ukuba uxinzelelo lwangaphakathi ludlula imida yoyilo. Olu yilo lukhuselekileyo lwenza ukungaphumeleli kokuthintela ukuqikelelwa nokulawuleka.

Amandla Okutshabalalisa Amandla

Ubungakanani bamandla okutsalwa ngamandla angaphezulu anokuthi afunxwe yisithinteli ngaphandle komonakalo kuxhomekeke ekuchithekeni kwamandla. Ukuze zikwazi ukumelana neziganeko zokutsalwa ngamandla eziphindaphindwayo, izithinteli zamandla aphezulu ziye zaphucula ukupholisa kunye nolwakhiwo lwangaphakathi.

Ukusebenza kwiiNdawo ezahlukeneyo

Ii-coefficients zobushushu zichaphazela ukusebenza kwe-arter kwiindawo ezahlukeneyo. Izithinteli zomgangatho zibonelela ngokhuseleko oluqhubekayo kwingqele ye-arctic ukuya kubushushu basentlango, nokuba indawo yokufakelwa ifakiwe iphi.

Ufakelo lwangaphandle Ukumelana nongcoliseko

Izinto ezifakelwe ngaphandle ezichatshazelwe yityuwa, ukukhutshwa kwegesi kwimizi-mveliso, okanye uthuli lwasentlango kufuneka zichasane nongcoliseko. Iindlu zepolymer ezintsha ziyachasana nokulandelwa kunye nokuguqulwa kwegesi kwiimeko ezingcolisayo eziya kubeka emngciphekweni izixhobo zokukhusela ukungcola zemveli.

Ubuchwepheshe obuSebenza kwiinkqubo zoKhuselo loMbane

Uphuhliso lweZithintelo zoMbane

Izixhobo zokuthintela umbane zanamhlanje zisekelwe kwiminyaka emininzi yezixhobo kunye nophando lobunjineli bombane. Ngenxa yeempawu zayo ezingcono zombane-umbane kunezoyilo ze-silicon carbide, itekhnoloji ye-zinc oxide varistor iye yaba yindlela ebalaseleyo.

Iindlela zokuVelisa eziNtu

Ukuphucula iipropati zombane kufuna ubungakanani obuchanekileyo bengqolowa, amanqanaba okusebenzisa idosi, kunye namaqondo obushushu okutshisa kwimveliso ye-varistor. I-element enye yokuthintela ineebhiliyoni zeendlela zokukhusela ezihambelanayo kuba ingqolowa nganye ye-zinc oxide yi-microscopic voltage regulator.

Uyilo lwezinto zezindlu

Itekhnoloji yezindlu zepolymer isuse ubulukhuni kunye nobunzima be-insulators ze-porcelain, yatshintsha uyilo lwe-arrester. Izindlu zerabha ze-silicone azinamanzi, zichitha amanzi ukuthintela ukulandelwa kombane.

Ulwakhiwo Oluvaliweyo Luyandisa Ukuqina

Ulwakhiwo oluvaliweyo lususa ukungena komswakama okubangele ukungasebenzi kakuhle kwe-arrier. Iikhompawundi zokuvala eziphambili zivumela ukwanda kobushushu becandelo langaphakathi kwaye zigcina ukuthembeka kuyo yonke imijikelo yobushushu.

Ulawulo Oluqinileyo Lomgangatho

Ulawulo lomgangatho wokwenziwa kwemveliso luqinisekisa ukusebenza kweqela ngalinye. Ukuze kuhlangatyezwane nemigangatho yamazwe ngamazwe, isixhobo ngasinye sivavanywa nge-impulse, sijikelezwe ngobushushu, kwaye sikhawuleziswe ukuba siguge.

Ukugcinwa kunye nokuBek' esweni okutsha

Izixhobo zokufakela ezifana nezitshintshi zokukhupha umbane zivumela uvavanyo kunye nokugcinwa kwenkqubo ngaphandle kokucima. Iimodeli eziphambili zibonelela ngedatha yokuthintela umbane kunye ne-surge ngexesha langempela ngokusebenzisa ukujonga kude.

Ukugcinwa Kwesibonisi Esikrelekrele

Izinzwa ezikrelekrele zivumela ukugcinwa kwangaphambili okuphucula ixesha lokutshintshwa kwaye zikhusele rhoqo. Ezi zinzwa zixela kwangaphambili iimeko zokuphela kobomi ngokujonga ukuvuza komsinga, ikhawuntara yokunyuka, kunye nobushushu bangaphakathi.

Iingenelo eziphambili kwizicelo zoshishino

Ukhuseleko kwiXesha lokungasebenzi kunye nokungaphumeleli kwezixhobo

Izithinteli zombane zikhusela ukusilela kwezixhobo okubangela ukuba imida yemveliso ivalwe ixesha elide. Ezi zixhobo zikhusela ingeniso yomveliso ngokunciphisa umngcipheko wokuphela okungalindelekanga.

Ubomi beSixhobo esongeziweyo kunye neeNdleko eziNcitshisiweyo zoLondolozo

Iimoto, iidrive, kunye neenkqubo zolawulo zihlala ixesha elide xa uxinzelelo lwe-voltage lugcinwa ngaphakathi kwemilinganiselo yoyilo. Izithinteli zombane zonyusa amaxesha okugcinwa kwaye zinciphisa iindleko zokulungisa ezingalindelekanga ngokunciphisa ukuwohloka kobushushu obuvela kwii-voltage spikes. Izithinteli ze-metal oxide zanamhlanje zisebenza amashumi eminyaka ngaphandle kokugcinwa, ngokungafaniyo nezithinteli zohlobo lwe-gap ezazifuna ukulungiswa rhoqo kunye nokutshintshwa. Olu phawu lugcina ukugcinwa kwezithinteli kuphantsi kulo lonke ixesha lazo lobomi.

Iingenelo zezeMali kunye ne-Inshurensi

Iingenelo zeinshorensi zihlala zilandela ukufakwa kwenkqubo yokukhusela ukuvuza kwamanzi. Ngenxa yomngcipheko ophantsi wamabango anxulumene nemozulu, uninzi lwabanini bomshuwalense banciphisa iipremiyamu kwizibonelelo ezineenkqubo ezibanzi zokukhusela umbane.

Ukuhambelana kwenkqubo kunye nokuphuculwa kokusebenza kakuhle kwamandla

Izithinteli zombane ziyahambelana neenkqubo zombane ezikhoyo, nto leyo eyenza kube lula ukuphinda zifakelwe. Uqwalaselo oluqhelekileyo lokufakelwa kunye noqhagamshelo lombane luvumela ukuhlanganiswa okulula kwiindlela ezikhoyo ngaphandle kotshintsho olukhulu. Izithinteli zombane ziphucula ukusebenza kakuhle kwamandla ngokuphelisa ukuphazamiseka kwe-voltage okubangela ukuba izixhobo zisebenze ngaphandle kweeparamitha ezifanelekileyo. Iidrives ze-frequency eziguquguqukayo, izibonelelo zombane, kunye neminye imithwalo ebuthathaka zisebenza ngokufanelekileyo ngamandla acocekileyo.

Unyino olunokubakho kunye nokuqwalaselwa

Iingxaki zoXinzelelo lweNkqubo kunye nokuLungelelanisa

Izithinteli zombane zinokuba nombane ogqithisileyo okwethutyana ngenxa yeziphene zenkqubo okanye iziphumo zokuvakala kwesandi. Iimeko zinokucinezela izithinteli ngaphaya kwamandla azo okusebenza ngokuqhubekayo, nto leyo ebangela ukungaphumeleli. Ulandelelwano olufanelekileyo lokusebenza ngexesha leemeko zempazamo lufuna ukulungelelaniswa okusebenzayo nezinye izixhobo zokukhusela. Iinkqubo ezingalungelelaniswanga kakuhle zinokubangela imisebenzi ephazamisayo okanye ukhuseleko olunganelanga, nto leyo eshiya izixhobo ezibalulekileyo zisengozini ngexesha leemeko zempazamo.

Imiba yokusiNgqongileyo kunye noFakelo

Izinto ezingqongileyo zichaphazela ukukhethwa kunye nokusebenza kwe-arter. Ukufakelwa kwendawo ephakamileyo kufuneka kuthathele ingqalelo uxinano lomoya oluphantsi kwi-insulation yangaphandle. Amaqondo obushushu aphezulu anokufuna iinkcukacha eziphezulu ze-arter. Umgangatho wokufakwa uchaphazela kakhulu ukusebenza kakuhle kwe-arter. Ukhuseleko oluphezulu lufuna isiseko esifanelekileyo, iindawo ezivulekileyo, kunye nokufakelwa. Ukufakelwa okungekho semgangathweni kunokunciphisa ukusebenza kakuhle kwe-arter kunye nokhuseleko.

Iindleko, Ukugcinwa, kunye noTshintsho

Izithinteli zombane zinokubiza kakhulu ukuzifaka, ingakumbi kwiindawo ezinkulu ezineeyunithi ezininzi. Nangona kunjalo, uhlalutyo lweendleko zomjikelo wobomi ludla ngokuzisa imbuyekezo entle ngokuthintela umonakalo kunye nexesha lokungasebenzi. Izithinteli zombane kufuneka zitshintshwe ngokukhawuleza ngokwemeko-bumenzi kunye nemeko-bume yendawo. Nangona izithinteli zinokuhlala amashumi eminyaka, iimeko ezinzima okanye umsebenzi oqhubekayo wokutsalwa ngamandla unokufuna ukutshintshwa kwangoko ukuqinisekisa ukhuseleko.

Uhlaziyo lweNkqubo kunye noLawulo lokuSebenza

Izithinteli zombane ezikhoyo kufuneka zihlolwe ngexesha lotshintsho lwevolthi yenkqubo. Ukuze kugcinwe imida yokhuseleko kunye nokusebenza kakuhle, izithinteli zinokufuna ukutshintshwa emva kotshintsho lwevolthi okanye ulungiselelo lwenkqubo.

Ukusebenza kweLightning Arrester xa kuthelekiswa nezinye iindlela

Uguquko oluvela kwiZibambiso zeMveli ukuya kwiZibambiso zanamhlanje

Izithinteli zemveli zohlobo lwesithuba ziqalise ukhuseleko lokuhamba ngamandla. Nangona zazibiza kancinci ekuqaleni, ezi zixhobo zazingasebenzi kakuhle, zigcinwa zisemgangathweni, kwaye ziphathwa ngendlela elinganiselweyo. Oku kuvelise izisombululo eziphucukileyo. Izithinteli ze-metal oxide zanamhlanje zibonelela ngokhuseleko olungcono ngolondolozo oluncinci. Ezi zithinteli zokuhamba ngamandla zezona zilungileyo namhlanje kuba zinokusingatha amanqanaba aphezulu amandla kwaye zisebenze ngokuthembekileyo.

Imida yeZixhobo zoKhuselo oluQokelelweyo

Izikhuseli zokushushuluza ezisebenzisa umbane ophantsi zikhusela ii-elektroniki ezinobuthathaka ngeendlela ezahlukeneyo. Ezi zixhobo azikwazi ukulawula amanqanaba amandla enkqubo yamandla anombane ophezulu, ngoko ke kufuneka izithinteli zokuthintela umbane ukuze kukhuselwe iziseko zophuhliso zombane eziphambili. Nangona izithinteli zetyhubhu yegesi zine-voltage ephezulu yokuvumela umbane ukuba ungene, ziphatha kakuhle ukushushuluza. Oku kuthetha ukuba azinakukukhusela izixhobo zanamhlanje, ezinobuthathaka ezifuna umbane ophantsi ukuze kukhuseleke. Nangona ii-transformers zokwahlukanisa kunye nezihluzi zisebenza kakuhle ekulungiseni umbane, azinakukwazi ukuphendula ngokukhawuleza kwii-transients ezibangelwa ngumbane. Zixhasa ukhuseleko lokuxhuzula kodwa azinakuthabatha indawo yesenzo sokukhusela umbane kwangoko.

Indima yeeNkqubo ze-UPS kuKhuseleko lwaMandla

I-UPS ikhusela kakuhle imithwalo eqhagamshelweyo kodwa ibiza kakhulu kwiinkqubo zombane ziphela. Izithinteli zombane zibonelela ngokhuseleko olupheleleyo kwinkqubo ngexabiso eliphantsi kakhulu, zivumela iinkqubo ze-UPS ukuba zigxile kumgangatho wamandla kunye nogcino.

Icebo Lokukhusela Elineziqendu Ukuze Uthembeke Kangcono

Izithinteli zombane kunye neetekhnoloji zokukhusela ezongezelelweyo zenza iinkqubo zokhuselo ezidibeneyo ezijongana nemiba emininzi yomgangatho wamandla. Le ndlela iphucula ukuthembeka kwenkqubo kunye nokumelana nokuphazamiseka kombane.

Izicelo Ezijoliswe Kuyo kunye Neemeko Zokusetyenziswa Ezifanelekileyo

Iindawo zoShishino

Izithinteli zombane ezisebenzayo zisetyenziswa kakhulu kwiindawo ezinkulu zoshishino. Abavelisi beemoto, amachiza, kunye nokutya bafuna ukusebenza rhoqo ukuze bafezekise iinjongo zemveliso. Ezi ndawo zixhamla kukhuseleko olupheleleyo lokushushuluza oluthintela ukuvalwa okubizayo okunxulumene nombane kwaye lugcina imveliso.

Amaziko Ononophelo Lwempilo

Izibhedlele zifuna umbane othembekileyo kwizixhobo zonyango ezibalulekileyo ebomini. Izixhobo zokuthintela umbane zikhusela izixhobo zokuxilonga ezibizayo, zotyando, nezokujonga izigulane kwiingxaki zombane, nto leyo ephucula ukhathalelo lwezigulane kunye nokuthembeka kweenkonzo zonyango.

Iziko leDatha

Amaziko edatha elifu, elezemali, kunye nonxibelelwano kufuneka agcine ixesha lokusebenza ukuze ahlangabezane nezivumelwano zenqanaba lenkonzo. Ukucima okunxulumene nombane kunokusasazeka kwiinethiwekhi ezidibeneyo, kuchaphazela amawaka abasebenzisi kwaye kubangele ilahleko ezinkulu zemali. Ukhuseleko lokugqobhoza luthintela oku.

Izitishi eziluncedo

Izitishi zeenkonzo ezisetyenziswa kwiindawo zokuhlala nezorhwebo zifuna ukhuseleko oluqinileyo ngexesha leenkqwithela ukuze kugcinwe uzinzo lwegridi. Izixhobo zokuthintela ukuvalwa kwezixhobo zithintela ukucima kwabathengi kwaye zikhusela izixhobo zeenkonzo ezisetyenziswa kwiindawo zokuhlala.

Ukufakelwa kwamandla avuselelekayo

Iifama zelanga kunye neefama zomoya zihlala zikwiindawo ezithandwa ngumbane. Ukhuseleko lwe-arrester luyimfuneko ukugcina olu tyalo-mali lunenzuzo nangona iimeko zokusingqongileyo zinzima kwaye zixhase ukutshintshela kumandla azinzileyo.

Umbane kaloliwe

Iinkqubo zombane kaloliwe kufuneka zikwazi ukumelana nombane kwiinethiwekhi ezinkulu zomqhubi weenqwelo-moya. Izixhobo zokuthintela umbane ziqinisekisa ukuqhubeka kwenkonzo yabakhweli kunye nokukhuselwa kombane otsalwayo ngexesha leemeko zemozulu embi, nto leyo ephucula ukhuseleko kunye nokuthembeka kwezothutho lukawonke-wonke.

isiphelo

Iinkqubo zombane zanamhlanje ziya zisiba sesichengeni sokuphazamiseka kwamandla ombane, ngoko ke izixhobo zokuthintela umbane zibalulekile. Isayensi yezinto eziphucukileyo kunye nemigaqo yobunjineli eqinisekisiweyo kwezi zixhobo zibonelela ngokhuseleko oluthembekileyo lokunyuka kwamandla kwiindlela ezahlukeneyo zokusebenza. Ukwazi ukusebenza kwazo, iingenelo, kunye neengxaki kunceda ukuphumeza amaqhinga okukhusela umbane apheleleyo. Izixhobo zokuthintela umbane ziya kulungelelanisa imingeni emitsha yokukhusela ngelixa zikhusela utyalo-mali olubalulekileyo lweziseko zophuhliso njengoko iinkqubo zombane ziba nzima kwaye zinobuthathaka.

Imibuzo ebuzwa qho

Q1: Zihlala ixesha elingakanani izithinteli zombane zisebenza?

A: Izithinteli zombane ze-metal oxide zanamhlanje zihlala iminyaka engama-20-30 phantsi kweemeko eziqhelekileyo. Iimeko zokusingqongileyo, amaxesha okusebenza kwe-surge, kunye nomgangatho wokufakwa zichaphazela ubomi benkonzo. Ukubeka esweni rhoqo kuphucula ixesha lokutshintshwa.

Umbuzo 2: Ngaba izinto zokuthintela umbane zingakhusela kuzo zonke iintlobo zombane oqhumayo?

A: Izinto zokuthintela umbane zisebenza kakuhle ekuthinteleni ukunyuka okubangelwa ngumbane kunye nokutshintsha ii-transients kodwa zisenokungawuphuculi umgangatho wamandla. Zisebenza kakuhle xa zidibene nezixhobo zokukhusela ukunyuka kwezixhobo ezibuthathaka kunye nezixhobo zokulungisa umbane ukuphucula umgangatho wamandla.

Umbuzo 3: Luluphi ulondolozo olufunekayo kwizinto ezithintela umbane?

A: Xa kuthelekiswa netekhnoloji endala, izithinteli ze-metal oxide azifuni kulungiswa kangako. Ukuhlolwa kokubona rhoqo ngonyaka kujonga umonakalo, ungcoliseko, kunye noqhagamshelo olukhululekileyo. Uvavanyo lombane rhoqo emva kweminyaka embalwa lujonga ukuvuza komsinga kunye nokhuseleko. Izithinteli zanamhlanje ezixhotyiswe ngemonitha zihlala zivavanya imeko.

Guqula uKhuseleko lwakho loMbane ngeZisombululo zeXi'an Xidian Lightning Arrester

Ungathembela kwiXi'an Xidian, umthengisi othembekileyo wezixhobo zokuthintela umbane , ukuba enze izixhobo zokuthintela umbane ezikumgangatho ophezulu kunye nezinye iimveliso zokukhusela umbane eziphucukileyo ezigcina izixhobo zombane ezibalulekileyo zikhuselekile. Izixhobo zethu ezilinganiswe kwiindawo eziphakamileyo zisebenza ngokufanelekileyo kwiindawo eziphakamileyo ukuya kuthi ga kwi-4,000 yeemitha kwaye zihlangabezana nemigangatho engqongqo yamazwe ngamazwe. Sinikezela ngeenkqubo zokhuseleko ezenziwe ngokwezifiso kwiifektri, izibhedlele, kunye namaziko edatha kulo lonke ilizwe. Iinguqulelo zethu zemveliso ezingaphezu kwe-100 kunye nobuchwepheshe be-polymer obunelungelo lobunikazi benza oku kube nokwenzeka. Ngaba ukulungele ukwenza isakhiwo sakho sikhuseleke kwiingxaki zokunyuka? Thumela ii-imeyile ku-serina@xaxd-electric.com , amber@xaxd-electric.com , kunye no-luna@xaxd-electric.com ukuze ufumane iingcebiso zeengcali.

Ucaphulo

1. Umgangatho we-IEEE C62.11-2012: Umgangatho we-IEEE wee-Metal-Oxide Surge Arresters ze-AC Power Circuits

2. IKhomishini ye-International Electrotechnical Commission IEC 60099-4: Izithinteli zokuxinana koxinzelelo - Icandelo 4: Izithinteli zokuxinana koxinzelelo lwe-metal-oxide ezingenazikhewu kwiinkqubo ze-ac

3. Hinrichsen, Volker. Izithinteli zokunyuka kweMetal-Oxide: Izinto ezisisiseko kunye nosetyenziso. Berlin: Springer-Verlag, 2019