productPic

Internal Fuse HV Shunt Capacitor

1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors.
  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service

Product Introduction

Internal Fuse HV Shunt Capacitor - Advanced Power Quality Solution

Product Introduction

Xian Xikai's Internal Fuse HV Shunt Capacitor represents cutting-edge technology in high-voltage power factor correction and harmonic filtering. Our capacitors feature sophisticated internal fuse protection that automatically isolates faulty elements while keeping your system operational. Unlike traditional externally fused units, our Internal Fuse HV Shunt Capacitor prevents catastrophic failures through individual element protection. This innovative design ensures maximum uptime for your power distribution network. With ratings from 1kV to 24kV and power capabilities up to 1000 kvar, our capacitors deliver reliable reactive power compensation for the most demanding applications.

Technical Specifications

Parameter Specification
Voltage Rating 1kV - 24kV
Power Rating Up to 1000 kvar
Frequency 50/60Hz
Capacitance Tolerance -5% to +10%
Maximum Current 2.5 × In
Loss Factor < 0.15 W/kvar
Discharge Time 75V within 10 minutes
Operating Temperature -40°C to +55°C
Dielectric All-film polypropylene
Standards Compliance IEC 60871-1, IEC 60871-4, IEEE Std 18

Main Features and Advantages

Superior Safety Design

Our capacitors eliminate the risk of explosive tank rupture through advanced internal fusing technology. Each element has its own protective fuse that operates instantly during fault conditions.

Continuous Operation

When an element fails, only that specific element is isolated. Your capacitor bank continues operating with less than 2% capacitance loss, preventing costly downtime.

Environmentally Friendly

We use synthetic aromatic hydrocarbon fluids with excellent gas-absorbing properties. This ensures long-term reliability while meeting environmental standards.

Compact Footprint

Internal fusing eliminates the need for bulky external fuse arrangements. This saves valuable space in your electrical installations.

Self-Healing Technology

Advanced polypropylene film technology provides excellent self-healing characteristics, extending service life significantly.

Practical Applications

HVDC Converter Stations

Essential for harmonic filtering in high-voltage DC transmission systems. Our Internal Fuse HV Shunt Capacitor maintains filter tuning even after element failures, ensuring stable power transmission.

Industrial Manufacturing

Perfect for steel mills, chemical plants, and heavy manufacturing facilities. These environments demand robust capacitors that can handle voltage fluctuations and harmonics without interrupting production.

Urban Substations

Indoor installations require compact, safe capacitor solutions. Internal fusing provides enclosed fault protection without debris ejection, making it ideal for populated areas.

Wind and Solar Farms

Renewable energy systems need reliable reactive power support. Our capacitors handle variable load conditions while maintaining grid stability.

How It Works

The Internal Fuse HV Shunt Capacitor operates on a microscopic isolation principle. Each capacitive element inside the tank has its own series-connected fuse link. When dielectric breakdown occurs in any element, the corresponding internal fuse immediately operates.

This isolates only the faulty element from the parallel group. The remaining healthy elements continue operating normally. Arc-quenching sheaths around each fuse prevent damage to adjacent elements during fault clearing.

Neutral unbalance protection monitors the slight capacitance change when fuses operate. This allows you to detect internal faults without opening the sealed tank.

Manufacturing Excellence

Xian Xikai brings over two decades of experience in medium and low voltage equipment manufacturing. Our production facility maintains strict quality control standards throughout the manufacturing process.

We use advanced vacuum impregnation techniques to ensure complete dielectric saturation. Each unit undergoes rigorous testing including internal fuse operation tests and high-temperature sealing verification.

Our quality management systems include ISO9001, ISO14001, and OHSAS18001 certifications. This ensures consistent product quality and environmental responsibility.

Why Choose Us

Proven Track Record

As a leading manufacturer of power distribution equipment, we understand the critical importance of reliable capacitor performance in your electrical systems.

Technical Expertise

Our engineering team has extensive experience with high-voltage capacitor design and application. We provide comprehensive technical support for your specific requirements.

Comprehensive Product Range

Beyond capacitors, we offer complete power distribution solutions including switchgear, transformers, and protection devices rated from 0.4kV to 40.5kV.

Quality Assurance

Every Internal Fuse HV Shunt Capacitor undergoes extensive factory testing to ensure it meets international standards and your performance expectations.

FAQ

Q: How do I know when an internal fuse has operated?

A: Internal fuse operation causes a slight capacitance change detected by neutral unbalance protection. This triggers an alarm without requiring visual inspection.

Q: Can these capacitors be repaired if a fuse blows?

A: No, units are hermetically sealed. Once enough fuses operate to trigger protection limits, the entire unit requires replacement to maintain system reliability.

Q: What's the advantage over externally fused capacitors?

A: Internal fusing provides continuous operation after faults, eliminates explosion risk, and requires less installation space compared to external fuse arrangements.

Q: How long do these capacitors typically last?

A: With proper application and maintenance, expect 20+ years of service life. The internal fusing technology actually extends operational availability compared to other designs.

Contact Us

Ready to enhance your power system reliability with our Internal Fuse HV Shunt Capacitor technology? Our technical team is ready to discuss your specific application requirements and provide detailed specifications.

Contact us today for technical consultation, pricing information, or to request detailed product documentation. We're committed to providing you with the optimal capacitor solution for your power quality needs.

Email: serina@xaxd-electric.com

Let us help you achieve superior power factor correction with maximum safety and reliability.

Send